• Title/Summary/Keyword: Design and Fabrication

Search Result 2,714, Processing Time 0.029 seconds

Design and Fabrication of butt-coupled(BT) sampled grating(SG) distributed bragg reflector(DBR) laser diode(LD) using planar buried heterosture(PBH) (저 전류 및 고 효율로 동작하는 양자 우물 매립형 butt-coupled sampled grating distributed bragg reflector laser diode 설계 및 제작)

  • Oh Su Hwan;Lee Chul-Wook;Kim Ki Soo;Ko Hyunsung;Park Sahnggi;Park Moon-Ho;Lee Ji-Myon
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.469-474
    • /
    • 2004
  • We have fabricated and designed wavelength-tunable sampled grating distributed Bragg reflector laser diodes(SGDBR-LD) by using, for the first time, planar buried heterostructures(PBH). The diodes have low threshold current values and high-performance of laser operation. Growth condition using metal organic chemical vapor deposition(MOCVD) was optimized for the formation of a good butt-coupling at the interface. A maximum output power of the fabricated device was 20 mW under 200 mA continuous wave(CW) operation at $25^{\circ}C$. Average threshold current and voltage were 12 mA and 0.8 V, approximately. This output power is higher than those of ridge waveguide(RWG) and buried ridge stripe(BRS) structures by amounts of 9 mW and 13 mW, respectively. We obtained a tuning range of 44.4nm which is well matched with the target value of our design. The side mode suppression ratio of more than 35 dB was obtained for the whole tuning range. Optical output power variation was less than 5 dB, which is 4 dB smaller than that of RWG structures.

Fabrication and characterization of the 0.25 ${\mu}m$ T-shaped gate P-HEMT and its application for MMIC low noise amplifier (0.25 ${\mu}m$ T형 게이트 P-HEMT 제작 및 특성 평가와 MMIC 저잡음 증폭기에 응용)

  • Kim, Byung-Gyu;Kim, Young-Jin;Jeong, Yoon-Ha
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.38-46
    • /
    • 1999
  • o.25${\mu}m$ T-shaped gate P-HEMT is fabricated and used for design of X0band three stage monolithic microwave integrated circuit(MMIC) low noise amplifier(LNA). The fabricated P-HEMT exhibits an extrinsis transconductance of 400mS/mm and a drain current of 400mA/mm. The RF and noise characteristics show that the current gain cut off frequency is 65GHz and minimum noise figure(NFmin) of 0.7dB with an associated gain of 14.8dB at 9GHz. In the design of the three stage LNA, we have used the inductive series feedback circuit topology with the short stub. The effects of series feedback to the noise figure, the gain, and the stability have been investigated to find the optimal short stub length. The designed three staage LNA showed a gain of above 33dB, a noise figure of under 1.2dB, and ainput/output return loss of under 15dB and 14dB, respectively. The results show that the fabricated P-HEMT is very suitable for a X-band LNA with high gain.

  • PDF

Creation of the dental virtual patients with dynamic occlusion and its application in esthetic dentistry (심미치의학 영역에서 동적 교합을 나타내는 가상 환자의 형성을 통한 전치부 보철 수복 증례)

  • An, Se-Jun;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.222-230
    • /
    • 2022
  • Digital technology is gradually expanding its field and has a great influence on various fields of dentistry. Recently in digital dentistry, the importance of superimposing various 3-dimensional (3D) image data is emerging, in order to utilize gathered data effectively for diagnosis and prosthesis fabrication. Integrating data from facial scans, intraoral scans, and mandibular movement recordings can create a virtual patient. A virtual patient is formed by integrating digital 3D diagnostic data such as intraoral and extraoral soft tissues, residual dentition, and dynamic occlusion, and the results of prosthetic treatment can be evaluated virtually. The patients in this case report were a 37-year-old female whose chief complaint is that the appearance of the existing prosthesis was distorted and a 55-year-old female patient whose anterior prosthesis needed to be refabricated after the endodontic treatment. 3D facial scans were obtained from each patient, and the patient's mandibular movements were recorded using ARCUS Digma 2 (KaVo Dental GmbH, Biberach an der Riss, Germany). The collected data were integrated on computer-aided design (CAD) software (Exocad dental CAD; exocad GmbH, Darmstadt, Germany) and transferred to a virtual articulator to create a digital virtual patient. The temporary fixed prostheses were designed, restored, and evaluated, and it was reflected into the final restorations. With the aid of the virtual dental patient, accuracy and predictability could be increased throughout treatment, simplifying the occlusal adjustment and clinical evaluation with improved esthetic outcomes.

Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods (다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교)

  • Hyuk-Joon Lee;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

Comparison of the fit of the coping pattern constructed by manual and CAD/CAM, depending on the margin of the abutment tooth (지대치 변연 형태에 따른 수작업과 CAD/CAM으로 제작한 coping 패턴의 적합도 비교)

  • Han, Min-soo;Kwon, Eun-Ja;Chio, Esther;Kim, Si-chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6611-6617
    • /
    • 2015
  • The purpose of this study is to compare the marginal and internal fit of metal and zirconia coping which is fabricated by manual and CAD/CAM(Computer Aided Design/Computer Aided Manufacturing). The model is prepared with Urethane material and two abutment teeth are fabricated with a knife and chamfer margin. Silicon replica technique is used to measure the marginal fit of manually fabricated and the CAD/CAM coping. Internal fitting level is measured with a microscope and the image is captured with a CCD camera. The distance between abutment teeth and coping is measured with a callibrated image analyzer software; marginal opening (MO), marginal gap (MG), internal gap (IG) at maximum curvature area, axial gap (AG), and occlusal gap (OG). Two-way ANOVA test is applied to compare fabrication technique and to analysis of abutment pattern. In addition, one-way ANOVA and Scheffe's test is used to analyze each parameter of the test. The result shows that the fit is < $120{\mu}m$ except OG of CAD/CAM and MO of knife margin. The CAD/CAM fabricated coping showed higher fit level at chamfer margin. However, knife margin showed better fitness compared to chamfer margin at MG. AG showed the minimum dimension with a constant result (< $38{\mu}m$).

Design of X-band 40 W Pulse-Driven GaN HEMT Power Amplifier Using Load-Pull Measurement with Pre-matched Fixture (사전-정합 로드-풀 측정을 통한 X-대역 40 W급 펄스 구동 GaN HEMT 전력증폭기 설계)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Yeom, Kyung-Whan;Jin, Hyeong-Seok;Park, Jong-Sul;Jang, Ho-Ki;Kim, Bo-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1034-1046
    • /
    • 2011
  • In this paper, a design and fabrication of 40 W power amplifier for the X-band using load-pull measurement of GaN HEMT chip are presented. The adopted active device for power amplifier is GaN HEMT chip of TriQuint company, which is recently released. Pre-matched fixtures are designed in test jig, because the impedance range of load-pull tuner is limited at measuring frequency. Essentially required 2-port S-parameters of the fixtures for extraction optimal input and output impedances is obtained by the presented newly method. The method is verified in comparison of the extracted optimal impedances with data sheet. The impedance matching circuit for power amplifier is designed based on EM co-simulation using the optimal impedances. The fabricated power amplifier with 15${\times}$17.8 $mm^2$ shows the efficiency above 35 %, the power gain of 8.7~8.3 dB and the output power of 46.7~46.3 dBm at 9~9.5 GHz with pulsed-driving width of 10 usec and duty of 10 %.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

A Miniaturized 2.5 GHz 8 W GaN HEMT Power Amplifier Module Using Selectively Anodized Aluminum Oxide Substrate (선택적 산화 알루미늄 기판을 이용한 소형 2.5 GHz 8 W GaN HEMT 전력 증폭기 모듈)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1069-1077
    • /
    • 2011
  • In this paper, a design and fabrication of a miniaturized 2.5 GHz 8 W power amplifier using selectively anodized aluminum oxide(SAAO) substrate are presented. The process of SAAO substrate is recently proposed and patented by Wavenics Inc. which uses aluminum as wafer. The selected active device is a commercially available GaN HEMT chip of TriQuint company, which is recently released. The optimum impedances for power amplifier design were extracted using the custom tuning jig composed of tunable passive components. The class-F power amplifier are designed based on EM co-simulation of impedance matching circuit. The matching circuit is realized in SAAO substrate. For integration and matching in the small package module, spiral inductors and single layer capacitors are used. The fabricated power amplifier with $4.4{\times}4.4\;mm^2$ shows the efficiency above 40 % and harmonic suppression above 30 dBc for the second(2nd) and the third(3rd) harmonic at the output power of 8 W.

Design of C-Band Frequency Up-Converter in Communication System for Unmanned Aerial Vehicle (무인 항공기의 통신 시스템에 사용되는 C-대역 주파수 상향 변환기 설계)

  • Lee, Duck-Hyung;Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.843-852
    • /
    • 2009
  • In this paper, we present design, fabrication, and measured results for a frequency upconverter for a wireless communication system of UAV(Unmanned Aerial Vehicle). The specifications of such wireless communication system requires the special features of maximum range of communication as well as deployment in UAV and repairing. The frequency upconverter operating at $5.25{\sim}5.45\;GHz$ in C-band was designed and fabricated considering such special features. The AGC function was included because the required output power should be constant for optimal system operation. The fabricated upconverter showed a constant output power of $+2{\pm}0.5\;dBm$ for the $-15{\sim}-10\;dBm$ input. Spuriouses were below -60 dBc and the adjacent leakage power was below -40 dBc. In addition, LO sources in the upconverter was implemented using the frequency synthesizer with step 1 MHz. This is for the application to the situation where multiple UAVs employed and the possible change of the permitted frequency band. The synthesizer showed a phase noise of -100 dBc/Hz at the 100 kHz frequency offset.

Design of a Miniaturized 5.3 GHz 360° Analog Phase Shifter (소형화된 5.3 GHz 대역 360° 아날로그 위상천이기 설계)

  • Jeong, Hae-Chang;Son, Bon-Ik;Lee, Dong-Hyun;Ahmed, Abdul-Rahman;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.6
    • /
    • pp.602-612
    • /
    • 2013
  • In this paper, a design and fabrication of miniaturized 5.3 GHz reflection type $360^{\circ}$ analog phase shifter with branch line coupler and $360^{\circ}$ variable reactance load. In order to miniaturize phase shifter, novel branch line coupler is proposed. The novel branch line coupler is miniaturized using transformation of transmission line to T and ${\pi}$ type equivalent circuit. The miniaturized branch line coupler has small size of above 50 % compared with conventional branch line coupler. For wide phase shift range, $360^{\circ}$ variable reactance load structure is adopted. Especially, the structure was improved for linear phase shift by adding transmission line which acts as an impedance transformer. The improved structure was miniaturized using the equivalent lumped-element of transmission line. The fabricated phase shifter with $15{\times}15mm^2$ shows wide phase shift of above $480^{\circ}$, the insertion loss of -4~-6 dB and the reflection loss of below -20 dB at 5.3 GHz under 0~10 V control voltage range.