• Title/Summary/Keyword: Design Load Cases

Search Result 466, Processing Time 0.029 seconds

Structural Design and Experimental Investigation of A Medium Scale Composite Wind Turbine Blade Considering Fatigue life

  • Kong, C.D.;Bang, J.H.;Jeong, J.C.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.88-89
    • /
    • 2002
  • The aims of this study is to realize the structural design for development of a medium scale E-glass/epoxy composite wind turbine blade for a 750KW class horizontal axis wind turbine system. In this study, the various load cases specified by the IEC61400-1 international specification and GL Regulations for the wind energy conversion system were considered, and a specific composite structure configuration which can effectively endure various loads such as aerodynamic and centrifugal loads, loads due to accumulation of ice, hygro-thermal and mechanical loads was proposed. In order to evaluate the structure, the structural analysis for the composite wind turbine blade were peformed using tile finite element method(FEM). In the structural design, the acceptable blade structural configuration was determined through the parametric studies, and the most dominant design parameters were confirmed. In the stress analysis using the FEM, it was confirmed that the blade structure was safe and stable in any various load cases Moreover the safety of the blade root joint with insert bolts, newly devised in this study, was checked against the design fond and the fatigue.

  • PDF

Heating and Cooling Load according to the Climatic Conditions of Foreign Cities (해외 주요 도시의 기후특성에 따른 최대공조부하 요소별 분석)

  • An, Seung-Hyun;Kim, Jong-Ho;Lee, Jung-Hun;Lee, Sang-Yup;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.81-87
    • /
    • 2014
  • According to the domestic construction business will continue stagnant, many domestic construction companies are expanding their business into foreign countries. As results, building design guidelines including HVAC design for foreign countries considering the regional climate conditions are needed. Also, green building design strategies to minimize the heating and cooling load are key issue to win a contract in construction business in the world. In this study, peak heating and cooling loads were calculated for the representative cities in the world : Seoul, St. Petersburg, Singapore and Mecca. The analyzed building was a typical high-rise office building and the building envelope properties, indoor heat gain, residence and operating schedules were same in all cases. Only the weather conditions were different by cases.

Case Study on Design Efficiency and Bearing Capacity Characteristics of Bored PHC Piles (PHC 매입말뚝의 설계효율과 지지력 특성 사례분석)

  • Yun, Jung-Mann;Yea, Geu-Guwen;Kim, Hong-Yeon;Choi, Yong-Kyu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.3
    • /
    • pp.45-53
    • /
    • 2019
  • In this study, it was analyzed the cases of bored PHC piles designed for the building foundations. The overall length of the piles varies within a maximum of 35 m. However, the average length was 17.0 to 18.9 m depending on the kind of the bedrock, with no significant difference. The socket length entered into the bedrock was designed with approximately 58% of the whole piles being 1m, the minimum length of the specification, and up to 5m. Although the range in design efficiency was very large, on average it was about 70%, consistent with the usual known extent. Applications with low design efficiency were mainly shown on the foundation of low-rise buildings or rides with low design load. On the weathered rock, the design load, which governs the design result was widely distributed at 65 to 97% of allowable bearing capacity of ground. The ratio of allowable axial load of piles to allowable bearing capacity of ground is also widely distributed between 36 and 115%, so optimization efforts are required along with design efficiency. On the other hand, the allowable bearing capacity on the soft or hard rock was highly equal, mostly within 90% of the allowable axial load of piles. In the design, the end bearing resistance averaged over 75% of the allowable bearing capacity. However, the results of the dynamic pile load test show that the end bearing resistance was predominant under the E.O.I.D conditions, and in some cases, the end bearing resistance was at least 25% under the restrike conditions.

A Study on the Loading Capacity Standard of Bi-directional Pile Load Test (BD PLT) (양방향말뚝재하시험의 재하용량 기준에 관한 연구)

  • Choi, Yongkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6C
    • /
    • pp.379-388
    • /
    • 2008
  • In the bi-directional pile load test (BD PLT) for pile load tests of Mega pile foundations, loading capacity standard is not specified exactly. Therefore there are so many confusions in performing the BD PLT and variations up to maximum 2 times in loading capacity are come out. In this study, standards of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio, loading capacity increasing ratio and sufficiency ratio of design load were analyzed. It could be known that the loading capacity standard of bi-directional pile load test must be defined as 1-directional loading capacity and also must be established as more than 2 times of design load.

Design of Electric Power Load Forecasting Model based on IT2TSK FLS (IT2TSK 퍼지논리 기반 전력부하 예측 모델 설계에 관한 연구)

  • Bang, Young-Keun;Shim, Jae-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1088-1095
    • /
    • 2015
  • In most cases, the use of electric power is associated with the economic scale of a nation closely. Thus, the electric power load forecasting plays an important role for the national economic plan. This paper deals with the design method for the electric power load forecasting system. In this paper, RCR-MA data processing, which can make the complex properties of the original data form simple, is proposed. Next, IT2TSK FLS, which can reflect the uncertainty of data more than T1TSK FLS, is applied. Consequently, the structural advantage of the proposed system can improve the forecasting accuracy, and is verified by using two types of electric power data.

Design of RC Plates and Shells subjected to Membrance Force and Flexural Moment (철근콘크리트 판형과 쉘의 휨과 막력을 고려한 설계)

  • 조홍진;민창식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.217-222
    • /
    • 2000
  • An iterative numerical computational algorithm is presented to design a plate or shell element subjected to membrance and flexural forces. Based on equilibrium consideration, equation for capacity of top and bottom reinforcements in two orthogonal directions have been derived. The amount of reinforcement is determined locally, I. e., for each integration point, from the equilibrium between applied and internal forces. Three cases of design are performed for slab element (used by Marti(1987)) and shell element (used by Kirscher and Collins(1986), by Polak and Vecchio(1993)) to verify the adequacy of the present design method for reinforced concrete shells. Based on nonlinear analyses performed, the analytically calculated ultimate load exceeded the design ultimate load. This shows the adequacy of the design method present in this study at least for slab and shell element case studied. To generalize the conclusion more design-analyses should be performed with different shell configurations.

  • PDF

On the Monlinear Analysis of Ship's Structures -Ultimate Strength Analysis of Plates and Stiffened Plates under Compressive Load- (선체구조물(선체구조물)에 관한 비선형(비선형) 해석연구(해석연구) -압축하중하(壓縮荷重下)의 평판(平板)과 보강판(補剛板)의 극한강도해석(極限强度解析)-)

  • J.D.,Koo;J.S.,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.20 no.1
    • /
    • pp.11-20
    • /
    • 1983
  • In this paper elastic-plastic large deflection analysis of ship structural members, plates, stiffened plates and cylindrical shallow shell, are performed by the finite element method. And for the consideration of the yielded propagation through the depth of the member, the layered element approach is employed. The present method is justified by comparing its results with those of experiment and others. As results, the nonlinear behavior and the ultimate strength curves are shown, which can be used in the design of the plates and the stiffened plates under compression, and the applicability to the shell structures is suggested. The analysis results are as followings. (1) The results of the approximate equations as well as those of buckling analysis may not guarantee precisely the safety of the structures in some cases and the optimum in other cases. Therefore they may not show the design criteria for the optimal design. (2) As the initial deflection increases, its effects on the ultimate strength of the structure generally increases, and the ultimate load, therefore, decreases. (3) This approach can be applied to the shell type structures. (4) The present method can be applied to the various structures composed of plate and beam members, for example, plates with hole and the stiffened plates with hole stiffened by spigot, doubler and/or stiffener, for the optimal design.

  • PDF

A Conversion of Load Carrying Capacity for Existing Steel Box Girder Bridge Based on Limit State Design Method (한계상태설계법에 의한 기존 강박스거더교의 내하력 환산)

  • Noh, Dong-Oh;Kyung, Kab-Soo;Park, Jin-Eun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.89-96
    • /
    • 2018
  • Bridge structures are a socially important infrastructure and safety management of bridges during the public service period is important. Steel box girder bridges, which account for a large percentage of road bridges, have been designed by allowable stress design method(ASD) and load carrying capacity have been evaluated using ASD. Although design specification has recently been changed to limit state design method(LSD), in most cases, ASD is still used for load carrying capacity evaluation. In this study, the two design methods were used to compare the results of a load rating factor evaluation on a number of bridges, and we are going to find out how to convert the existing rating factor by ASD into rating factor by LSD. The results of this study are expected to can be used as a basis for determining the need for reinforcement and evaluating load carrying capacity by LSD in bridge maintenance.

Conceptual design of prestressed slab bridges through one-way flexural load balancing

  • Arici, Marcello;Granata, Michele Fabio
    • Structural Engineering and Mechanics
    • /
    • v.48 no.5
    • /
    • pp.615-642
    • /
    • 2013
  • In this paper a study on prestressed concrete slab bridges is presented. A design philosophy based on the concept of load balancing through prestressing is proposed in order to minimize the effects of delayed deformations due to creep. Aspects related to the stress redistribution inside these bridges for time-dependent phenomena are analyzed and discussed, by applying the principles of aging linear visco-elasticity. Prestressing is seen as an equivalent external load which counterbalances the permanent loads applied to the bridge, nullifying the elastic deflections due to sustained loads, and thus avoiding the related delayed deformations. An optimization of the structural behavior through the use of one-way prestressing is achieved. The determination of a convenient variable depth of slab bridges and the correspondent layout of tendons is considered as a useful means for applying the load balancing concept in actual cases of structures like long cantilevers or bridge decks. A case-study related to the slab bridges built 30 years ago at Jeddah in Saudi Arabia is presented and discussed, in order to show the effectiveness of the proposed approach to the conceptual design of prestressed concrete bridges.

Sensitivity Analysis and Optimal design for the Elasto-plastic buckling of Vehicle Structures (차체구조물의 탄소성좌굴에 관한 민감도해석과 최적설계)

  • Won, Chong-Jin;Lee, Jong-Sun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.5
    • /
    • pp.106-112
    • /
    • 1998
  • Experience and experiments show that in many cases the buckling limit is reached at a much smaller load level than is predicted by linear buckling analysis. In this paper, it is considered linear and nonlinear of plane vehicle structure and estimates design sensitivity of the cross sectional area that is composed plane vehicle structure and performs optimal design. It compares linear vehicle structure with nonlinear vehicle structure for optima design result that is selected constraint condition of buckling load.

  • PDF