• Title/Summary/Keyword: Derived Air Concentration

Search Result 121, Processing Time 0.022 seconds

A Dynamic-Stochastic Model for Air Pollutant Concentration (大氣汚染濃度에 관한 動的確率모델)

  • 김해경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.156-168
    • /
    • 1991
  • The purpose of this paper is to develop a stochastic model for daily sulphur dioxide $(SO_2)$ concentrations prediction in urban area (Seoul). For this, the influence of the meteorological parameters on the $SO_2$ concentrations is investigated by a statistical analysis of the 24-hr averaged $SO_2$ levels of Seoul area during 1989 $\sim$ 1990. The annual fluctuations of the regression trend, periodicity and dependence of the daily concentration are also analyzed. Based on these, a nonlinear regression transfer function model for the prediction of daily $SO_2$ concentrations is derived. A statistical procedure for using the model to predict the concentration level is also proposed.

  • PDF

A Stochastic Model for Air Pollutant Concentration (大氣汚染濃度에 관한 確率모델)

  • 김해경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.127-136
    • /
    • 1991
  • This paper is concerned with the development and application of a stochastic model for daily sulphur dioxide $(SO_2)$ concentrations in urban area (Seoul). For this, the characteristics of the regression trend, periodicity and dependence of the daily $SO_2$ concentration are investigated by a statistisical analysis of the daily average $SO_2$ values measured in Seoul area during 1989 $\sim$ 1990. Based on these, nonlinear regression time series model for the prediction of daily $SO_2$ concentrations is derived. A statistical procedure for using the model to predict the concentration level is also proposed.

  • PDF

Concentration Response Functions for Particulate Matter related Health Risk Assessment in South Korea (입자상 대기오염물질의 건강 위해성 평가를 위한 국내 농도반응함수 도출)

  • Ha, Jongsik
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.202-213
    • /
    • 2017
  • Objectives: HRA (Health Risk Assessment) is an important tool for measuring the health impacts of air pollution. HRA is already being used widely as an important reference for crafting air pollution policies. However, the absence of a domestic CRF (Concentration Response Function) standard, which is a main component for HRA, could cause confusion amongst policy-makers. The purpose of this study is to tabulate a domestic CRF standard for a PM (Particulate Matter)-related HRA. Methods: This study suggested a domestic CRF standard for HRA thorough a literature review. The literature review for meta-analysis was limited to the English language for epidemiological studies published from January 1980 to March 2016. This meta-analysis was conducted by assuming both fixed- and random-effects of CRF. In addition, studies that reported HRA of air pollution for WHO (World Health Organization), the EC (European Commission), and the EPA (Environmental Protection Agency) were reviewed to compare the CRFs of South Korea to the recommended CRFs of WHO, the EC, or the EPA. Additionally, a domestic CRF standard was supplemented by these. Results: Nineteen studies were selected for the CRF for South Korea. Fifty-three CRFs were derived for meta-analysis. CRFs with a standard for PM-related HRA were divided according to the following four criteria: air pollution, exposure characteristics, type of health impact, and age group. Finally, a domestic CRF standard was created comprised of 21 CRFs. Among these, six CRFs were derived from the results of foreign HRA studies. Conclusions: This study is important in that a domestic CRF standard is first suggested. In addition, this study suggests a further area of study for using HRA as a policy tool and a direction of epidemiological study.

Determination of Derived Release Limits by the Concentration Factor Method (농축인자법에 의한 유도방출 기준 설정)

  • Byung Woo Kim;Byeung Kyu Kim;Jeong Ho Lee
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.267-278
    • /
    • 1985
  • Some kinds of methods have been applied to regulate the exposure doses by the radioactive effluents from nuclear power plants. The essential one is primary dose equivalent limit recommended by the ICRP. When the primary limit cannot be applied directly for regulation, there have been dose equivalent index in case of external exposure, or maximum permissible concentration, annual limit on intake, derived air concentration and maximum permissible body burden in case of internal exposure. But the derived limit is required from the viewpoint of discharge, for those values are inadequate to control discharge rate directly. This study was carried out to derive the release limit for the Wolsung nuclear power plant by the concentration factor method. This method is based on the assumption of steady state transfer between environment compartments.

  • PDF

Nitrification Performance of a Moving Bed Bioreactor (MBBR) at Different Ammonia and Hydraulic Air-Loading Rates under Seawater Conditions (해수 조건에서 총암모니아성 질소 부하량과 수리학적 공기 부하량에 따른 유동상 여과조의 질산화 성능 평가)

  • Jaegeon Lee;Younghun Lee;Jeonghwan Park
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.6
    • /
    • pp.870-877
    • /
    • 2023
  • The purpose of this study was to assess the efficiency of nitrification based on ammonia loading rates and hydraulic air-loading rates in a moving bed bioreactor (MBBR) under seawater conditions. The goal was to provide foundational data for the design of these bio reactors. At an ammonia loading rate of 0.2 g TAN·m-2 surface area·day-1, the influent TAN concentration was determined to be 1.76±0.33 mg·L-1, which is below the safe concentration for fish survival (2 mg·L-1). Considering operational aspects, the optimal ammonia-loading rate was derived. Subsequently, experimental results for nitrification efficiency at the optimal ammonia-loading rate revealed that the optimum hydraulic air-loading rate was 1.8 L·air·m-2 surface area·min-1. This condition resulted in the lowest concentrations of TAN and NO2-N in the influent water, thus establishing the optimal hydraulic air-loading rate. A regression equation was derived for the ammonia-removal rate (Y) based on the ammonia-loading rate (x) and expressed as a 0.5-order equation (Y=ax0.5+b). Specifically, for TAN concentrations of 0-6 mg·L-1, the regression equation Y=0.1683x0.5-0.13628, was established.

Study on Accuracy and Validity Tests for Various Prediction Models for Gas and Vapor Respirator Cartridge Service Lives (가스 및 유기용제용 호흡보호구의 정화통에 대한 수명예측방법의 정확도 및 타당성 검증연구)

  • Park, Doo Yong;Park, Ji Young;Yoon, Chung Sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.19-31
    • /
    • 1999
  • Most breakthrough tests are conducted at higher concentration levels compared to those in the field of air-purifying respirator applications. For example, typical challenge concentrations for breakthrough tests agains tcarbon tetrachloride are ranged between 250-1000 ppm although applicable concentrations range for air-purifying cartridge is 5-50 ppm for carbon tetrachloride. However, no guarantee has been made that isotherms derived from the experiment at high challenge concentrations could estimate adsorption capacity at the lower concentration range where workers wear usually air-purifying respirators. Three models of adsorption isotherms (Freundlich, Langmuir and Dubinin/Radushkevich(D/R) isotherms) that have been commonly applied for respirator cartridge testing were evaluated. Adsorption capacity at each challenge concentration was calculated from the Reaction Kinetic equation fitted for the breakthrough data. These data were used for derivation of three isotherms. In general, the D/R isotherm has given the best agreement between estimated adsorption capacities and experimentally measured. If the challenge concentration of 100 ppm is included for derivation of models, Freundlich and D/R models could succes sfully produced good estimations for adsorption capacities at 50 ppm level. Estimated adsorption capacities by both models ranged in 94 - 109 % of the experimentally measured. However, Langmuir model gives underes timation in all cases.

  • PDF

Effect of Airborne Organic Vapor Concentration Levels on the Adsorption Capacity of Charcoal in the Cartridges of Air Purifying Respirators (공기 중 유기용제 농도수준이 방독마스크 정화통의 활성탄 흡착용량에 미치는 영향)

  • Park, Doo-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.1
    • /
    • pp.50-56
    • /
    • 2011
  • The adsorption capacity of charcoal is a function of the airborne concentration of the target chemical. To evaluate the adsorption capacity of charcoal packed in the cartridges of air purifying respirators, breakthrough tests were conducted with carbon tetrachloride for three commercial cartridges (3M models #7251, #6000 and AX) at 25, 50, 100, 250 and 500 ppm. Adsorption capacities were calculated using a mass transfer balance equation derived from the curve fitting to the breakthrough curves obtained experimentally. Carbon micropore volumes were estimated by iteration to fit the Dubinin/Radushkevich (D/R) adsorption isotherm. They were 0.6566, 0.5727 and 0.3087 g/cc for #7251, #6000 and the AX cartridge, respectively. Above 100 ppm (at high challenge concentrations), #7251 and #6000 showed higher adsorption capacities. However, as the challenge concentration decreased, the adsorption capacities of #7251 and #6000 sharply dropped. On the other hand, the adsorption capacity of the AX cartridge showed little change with the decrease of the challenge concentration. Thus, the AX showed a higher adsorption capacity than #7251 and #6000 at the 5-50 ppm level. It is concluded that service-life tests of cartridges and adsorption capacity tests of charcoal should be conducted at challenge concentration levels reflecting actual working environmental conditions. Alternatively, it is recommended to use the D/R adsorption isotherm to extrapolate adsorption capacity at low concentration levels from the high concentration levels at which breakthrough tests are conducted, at a minimum of two different concentration levels.

Reduced Chemical Kinetic Mechanism for Premixed CO/H2/Air Flames ([ CO/H2/Air ] 예혼합 화염에 대한 준총괄 화학반응 메커니즘)

  • Jang, Kyoung;Cha, Dong-Jin;Joo, Yong-Jin;Lee, Ki-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.2
    • /
    • pp.133-140
    • /
    • 2008
  • A reduced chemical kinetic mechanism is developed in order to predict the flame phenomena in premixed $CO/H_2/Air$ flames at atmospheric pressure, aimed at studying the coal gas combustion for the IGCC applications. The reduced mechanism is systematically derived from a full chemical kinetic mechanism involving 11 reacting species and 66 elementary reactions. This mechanism consists of four global steps, and is capable of explicitly calculating the concentration of 7 non-steady species and implicitly predicting the concentration of 3 steady state species. The fuel blend contains two fuels with distinct thermochemical properties, whose contribution to the radical pool in the flame is different. The flame speeds predicted by the reduced mechanism are in good agreement with those by the full mechanism and experimental results. In addition, the concentration profiles of species and temperature are also in good agreement with those by the full mechanism.

GIS-based PM10 Concentration Real-time Service (GIS기반 PM10 미세먼지농도 실시간 서비스)

  • Yoon, Hoon Joo;Han, Gwang In;Cho, Sung Ho;Jung, Byung hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.6
    • /
    • pp.585-592
    • /
    • 2015
  • In this study, by applying mobile based GIS and image analysis of particulate matter ($PM_{10}$) concentration in Seoul and Ulsan in Korea, to identify the user's location and also implemented the application to information exchange. It strengthened citizens' access to air quality information through the application and derived the expanded environment information sharing through real-time user participation. Through atmospheric concentrations image analysis, it showed a new environmental information construction possibility. It had the effect of expanding the information collecting through the local user participation on the limited information collected area which place is not yet constructed atmospheric monitoring network. Location-based particulate matter information service application provides a user location's $PM_{10}$ information from the 25 urban air monitoring network real-time database of the Ministry of Environment. Furthermore, if the user sent a picture of the atmosphere to the server, should match the image density values of the database and express on Seoul's maps through the IDW interpolation. And then a $PM_{10}$ concentration result is transmitted to user in real time.

Combustion of RDF and RPF in a Lab-Scale Circulating Fluidized Bed (실험실규모 순환유동층에서 RDF와 RPF의 연소 특성에 관한 연구)

  • Lee, J.S.;Lee, E.L.;An, M.H.;Park, S.U.;Shin, D.H.;Hwang, J.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.173-179
    • /
    • 2004
  • Combustion of refuse derived fuel(RDF) and refuse plastic fuel (RPF) was carried out in a lab-scale circulating fluidized bed. Experiment was investigated cold flow visualization. RDF was made by C & tech and RPF was made by KRS. The results include distribution of temperature in the combustion chamber, and concentrations of flue gas such as $O_2$, $CO_2$, CO, $NO_x$ and HCs Micro G.C(gas chromatograph) was employed to find out concentration of He Temperature distribution was different when RDF and RPF were burnt respectably. As air ratio became increased, $CO_2$, CO, and total of HCs emissions were decreased. According to the number of carbon atom of HCs, HC were classified as five kinds of HC.

  • PDF