• 제목/요약/키워드: Depth-Test

검색결과 3,452건 처리시간 0.034초

성인 약물남용 재활 프로그램의 효과성 연구 (A Study on effectiveness of the relapse prevention program for adult substances abusers)

  • 장진경
    • 가정과삶의질연구
    • /
    • 제19권1호
    • /
    • pp.33-52
    • /
    • 2001
  • The purpose of this study was to examine the effectiveness of using the relapse prevention program for adult substance addicts. Based on the results from the study of educational needs for the relapse prevention program among substance addicts the 10-session-relapse prevention program was developed. Then the researcher conducted the relapse prevention program for 15 adult methamphetamine addicts from Aug. 3 1999 to Sep. 4 1999 at the probation office in Suwon, South Korea. For examining the effectiveness of using that relapse prevention program the Social Adjustment Scale-Self Report(SAS-SR), McMullin Addiction Thought Scale(MAT), and Self Esteem Rating Scale(SERS) were used whether or not their social adjustment level, self-esteem level, and addiction thought level were improved. This study employed one group pre-post test research design as a quantitative purpose and in-depth interview as a qualitative purpose. For a qualitative purpose in-depth interview was conducted in not only between sessions but also after sessions dealing with their current life problems. For a quantitative purpose the analysis strategy employed here was frequency and t-test. Results shows that addicts who took the relapse prevention program consistently reported the improvement of their social adjustment level, self-esteem level, and addiction thought level although there were no statistically significant between pre and post tests. The implication of study findings will be discussed.

  • PDF

해진시 개단무리말뚝의 거동에 관한 모형실험 연구 (An Experimental Study on the Behavior of Open-ended Pipe Piles Ggroup to the Simulated Seaquake)

  • 남문석;최용규;김재현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.447-454
    • /
    • 1999
  • The compressive capacity and the soil plugging resistance of single open-ended pipe pile were completely decreased in the previous study on the behavior of shorter single pile during simulated seaquake induced by the vertical component of earthquake. But the capacity of single open-ended pipe pile with greater penetration and the capacity of piles group with shorter penetration were expected to be stable after seaquake motion. In this study, first, 2-piles or 4-piles are driven into the calibration chamber included in saturated fine medium sand with several simulated penetrations, and the compressive load test for each piles group was performed. Then, about 95 % compressive load of the ultimate capacity was applied on the pile head during the simulated seaquake motion. Finally, In confirm the reduction of pile capacity during the simulated seaquake motion, the compressive load test for each single pile or piles group after seaquake motion was performed. During the simulated seaquake, the compressive capacity of open-ended pipe piles with greater penetration ( 〉about 27 m) was not degraded even in deep sea deeper than 220 m and soil plug within open-ended pipe pile installed in deep sea was stable after seaquake motion. Also, in the case of 2-piles or 4-pile groups, the compressive capacity after seaquake motion was not degraded at all regardless of pile penetration depth beneath seabed, sea water depth and seaquake frequency.

  • PDF

Shear strength of reinforced concrete dapped-end beams

  • Lin, Ing-Jaung;Hwang, Shyh-Jiann;Lu, Wen-Yao;Tsai, Jiunn-Tyng
    • Structural Engineering and Mechanics
    • /
    • 제16권3호
    • /
    • pp.275-294
    • /
    • 2003
  • In this study, 24 high-strength concrete dapped-end beams were tested to study the effects of the amount of main dapped-end reinforcement, the nominal shear span-to-depth ratio, and the concrete strength on the shear strength of dapped-end beams. Test results indicate that the shear strength of dapped ends increases with the increase in the amount of main dapped-end reinforcement and the concrete strength. The shear strength of dapped-end beam increases with the decrease of nominal shear span-to-depth ratio. A simplified method for determining the shear strength of reinforced concrete dapped ends is also proposed in this paper. The shear strengths predicted by the proposed method and the approach of PCI Design Handbook are compared with test results. The comparison shows that the proposed method can more accurately predict the shear strength of reinforced concrete dapped-end beams than the approach of PCI Design Handbook.

조현병 환자의 입원 스트레스 측정도구 개발 (Development of a Measurement of Stress for Hospitalized Schizophrenic Patient)

  • 박순아;성경미
    • 대한간호학회지
    • /
    • 제44권3호
    • /
    • pp.339-349
    • /
    • 2014
  • Purpose: This study was done to develop a measurement for stress experienced by patients with schizophrenia during hospitalization. Methods: The preliminary tool was developed through in-depth interviews and a validity verification test of content. For data collection, 15 inpatients with schizophrenia were selected as participants for in-depth interviews and 195 patients admitted to one of eight psychiatric hospitals in four provinces were recruited as participants to test reliability and validity of the preliminary tool. Results: The questionnaire was developed as a four-point Likert-type scale in a self-report form with 28 items. Factor analysis showed 28 items in six factors. Factors were named 'Unjust human rights infringement', 'Futureless life', 'Alienation from other family members', 'Infringement of basic needs', 'Infringement of personal preference' and 'Inconvenience of shared living'. The six factors explained 63.5% of the total variance. Cronbach's alpha for the total items was .93 and for the factors ranged from .65 to .87. Conclusion: A tool to measure stress in patients hospitalized with schizophrenic was developed based on identified hospitalization stress experiences. Study results indicate that this tool can be used to evaluate hospitalization stress in these patients and will contribute to establishing nursing interventions for relief of hospitalization stress.

Burst Behavior for Mechanically Machined Axial Flaws of Steam Generator Tubings

  • Hwang, Seong Sik;Kim, Hong Pyo;Kim, Joung Soo
    • Corrosion Science and Technology
    • /
    • 제3권1호
    • /
    • pp.30-33
    • /
    • 2004
  • It has been reported that some events of a rupture of seam generator tube have occurred in nuclear power plants around the world. Main causes of the leakage are from various types of corrosion in the steam generator(SG) tubings. Primary water stress corrosion cracking(PWSCC) of steam generator tubings have occurred in many tubes in Korean plant, and they were repaired using sleeves or plugs, In order to develop proper repair criteria, it is necessary to ascertain the leak behavior of the tubings. A high pressure leak and burst testing system was manufactured. Various types of Electro Discharged Machined (EDM) notches were developed on the SG tubes. Leak rate and burst pressure were measured on the tubes at room temperature. Burst pressure of the part through wall defected tubes depends on the defect depth, Water flow rates after the burst were independent of the t1aw types; tubes having 20 to 60 mm long EDM notches showed similar flow rates regardless of the defect depth. A fast pressurization rate gave the tube a lower burst pressure than the case of a slow pressurization.

경량벽체 표면의 패임에 대한 시각적 판단방법에 관한 기초적 연구 (A basic study on Visual judgment method for the Dent of Lightweight wall surface)

  • 김진식;신윤호;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.36-37
    • /
    • 2015
  • Recently, there has been a rapid increase in demand for lightweight walls for their use as interior partitions, as types of structure have gradually changed from shear wall structures to column structures or flat plate column wall systems. The lack of resisting force in lightweight walls is found by measuring the depth of dents in impact resistance tests, but it is not a direct factor of impact resistance. However, in the user's position, dents of over a certain size are clearly a factor that visually reminds the need for repair. In this study, we reviewed relative methods of assessment of the need for repair based on the visual means of determination (sensory test) on the dents on lightweight walls. Dents were found to stand out starting from depths of about 4mm, and the depth of roughly 5mm was found to be the criterion for determining the necessity of repair for men, while it was 4mm for women.

  • PDF

Behavior of reinforced lightweight aggregate concrete hollow-core slabs

  • Al-Azzawi, Adel A.;Al-Aziz, Basma M. Abdul
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.117-126
    • /
    • 2018
  • This research investigate the behavior of reinforced normal and lightweight aggregate concrete hollow core slabs with different core shapes, shear span to effective depth (a/d). The experimental work includes testing seven reinforced concrete slabs under two vertical line loads. The dimensions of slab specimens were (1.1 m) length, (0.6 m) width and (0.12 m) thickness. The maximum reduction in weight due to aggregate type was (19.28%) and due to cross section (square and circular) cores was (17.37 and 13.64%) respectively. The test results showed that the decrease of shear span to effective depth ratio from 2.9 to 1.9 for lightweight aggregate solid slab cause an increase in ultimate load by (29.06%) and increase in the deflection value at ultimate load or the ultimate deflection by (17.79%). The use of lightweight aggregate concrete in casting solid slabs give a reduction in weight by (19.28%) and in the first cracking and ultimate loads by (16.37%) and (5%) respectively for constant (a/d=2.9).The use of lightweight aggregate concrete in casting hollow circular core slabs with constant (a/d=2.9) (reduction in weight 32.92%) decrease the cracking and ultimate loads by (12%) and (5.18%) respectively with respect to the solid slab. These slab specimens were analyzed numerically by using the finite element computer program ANSYS. Good agreements in terms of behavior, cracking load (load at first visible crack) and ultimate load (maximum value of testing load) was obtained between finite element analysis and experimental test results.

고온층계통의 이온교환기에 의한 연구로 수조 상부 방사선의 저감효과에 대한 연구 (Study for Reduction Effect of Pool Top Radiation in Research Reactor by Using Ion Exchanger of Hot Water Layer)

  • 박용철;박종호
    • 한국유체기계학회 논문집
    • /
    • 제2권4호
    • /
    • pp.40-47
    • /
    • 1999
  • A hot water layer (HWL hereinafter) was installed at the depth of 1.2 m from the pool surface to reduce the radiation level at the pool top. After the HWL system was improved by the replacement of the filter with the Ion Exchanger to capture the Na-24, to purify the pool water of HWL and finally to reduce the radiation at the pool top. It was confirmed by the performance test of the pump and the measurement of the pressure difference through the Ion Exchanger and the strainer, that the flow characteristics of HWL system was not adversely affected after the system modification. Also the flow analysis using the pressure loss coefficients of the Ion Exchanger and strainer, calculated by the Darcy formula, could predict the flow variations by pressure changes within $10\%$ error in comparison with the field test results. It was also confirmed that HWL was maintained with the depth of 1.2 m from the pool surface because each electric water heater was electrically and thermodynamically maintained at 30 kW and the temperature of HWL was maintained with $5^{\circ}C$ higher temperature than that of pool water. Finally, it was confirmed that the pool top radiation was saturated and stabilized below 10000 nG/hr within 24 hours as the ion exchanger captured the main nucleus, Na-24 and purified the pool water of HWL.

  • PDF

히트펌프용 수직형 지중열교환기의 성능에 관한 연구 (A Study on Performance of Vertical Ground Heat Exchanger for Heat Pump)

  • 장기창;정민호;윤형기;나호상;유성연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.466-469
    • /
    • 2007
  • Heat pumps are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. And a vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double n-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

Improvement of tip analysis model for drilled shafts in cohesionless soils

  • Chen, Yit-Jin;Wu, Hao-Wei;Marcos, Maria Cecilia M.;Lin, Shiu-Shin
    • Geomechanics and Engineering
    • /
    • 제5권5호
    • /
    • pp.447-462
    • /
    • 2013
  • An analysis model for predicting the tip bearing capacity of drilled shafts in cohesionless soils is improved in this study. The evaluation is based on large amounts of drilled shaft load test data. Assessment on the analysis model reveals a greater variation in two coefficients, namely, the overburden bearing capacity factor ($N_q$) and the bearing capacity modifier for soil rigidity (${\zeta}_{qr}$). These factors are modified from the back analysis of drilled shaft load test results. Different effective shaft depths and interpreted capacities at various loading stages (i.e., low, middle, and high) are adopted for the back calculation. Results show that the modified bearing capacity coefficients maintain their basic relationship with soil effective friction angle ($\bar{\phi}$), in which the $N_q$ increases and ${\zeta}_{qr}$ decreases as $\bar{\phi}$ increases. The suggested effective shaft depth is limited to 15B (B = shaft diameter) for the evaluation of effective overburden pressure. Specific design recommendations for the tip bearing capacity analysis of drilled shafts in cohesionless soils are given for engineering practice.