Photon Beam Commissioning for Monte Carlo Dose Calculation

  • Cho, Byung-Chul;Park, Hee-Chul;Hoonsik Bae
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.106-108
    • /
    • 2002
  • Recent advances in radiation transport algorithms, computer hardware performance, and parallel computing make the clinical use of Monte Carlo based dose calculations possible. Monte Carlo treatment planning requires accurate beam information as input to generate accurate dose distributions. The procedures to obtain this accurate beam information are called "commissioning", which includes accelerator head modeling. In this study, we would like to investigate how much accurately Monte Carlo based dose calculations can predict the measured beam data in various conditions. The Siemens 6MV photon beam and the BEAM Monte Carlo code were used. The comparisons including the percentage depth doses and off-axis profiles of open fields and wedges, output factors will be presented.

  • PDF

Characteristics of Specific Absorption Rate (SAR) in Electromagnetic (EM) Dosimetry

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • 제25권2호
    • /
    • pp.109-114
    • /
    • 2000
  • The SI unit of specific absorption rate (SAR) in W/kg in the electromagnetic (EM) field as non-ionizing radiation is exactly same as the SI unit of absorbed dose rate in Gy/s in the ionizing radiation field. The SI unit of both physical quantities can be expressed in $[m^{\cdot}s^{-3}]$. Where, the unit of absorbed dose, Gy stands for Gray. In EM biological interactions, the SAR equations are derived and the characteristics of EM field energy absorption in terms of the SAR are discussed and described on the mathematical basis.

  • PDF

6MV X-선 선축중심선상에서의 BEAM 특성 - Siemens MEVATRON KD 선형가속기에서 P. D. D와 TMR을 중심으로 - (The Central Beam Characteristics of 6 MV X-Ray - The PDD and TMR for Siemens Linear Accelerator K.D. -)

  • 정칠;김병욱
    • 대한방사선치료학회지
    • /
    • 제3권1호
    • /
    • pp.63-67
    • /
    • 1989
  • The central beam characteristics of 6 MV X-ray from a Mevatron KD linear Accelerator are examin-depths The PDD (Percent Depth Dose) values and the TMR (Tissue Maximum Ratio) values are evaluated from measurement as a function of the depths and the field sizes. The calculated TMR values from the PDD are compared to those from measurement. The average differences between calculated TMR and measured one are within $1\%$ and we have concluded that calculated TMR values are acceptable for practical use.

  • PDF

선형가속기의 6MV X선에 대한 소형조사면의 선량측정 (Dose Characteristics of Small Radiation Fields for 6MV X-ray of Linear Accelerator)

  • 최태진;김옥배;김영훈;손은익;김인홍
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.287-291
    • /
    • 1989
  • Radiation dosimetry has been extended to small fields less than $4\times4cm^2$ which may be suitable for irradiation of small intracranial tumors. Special consideration was given to the percentage depth dose and scatter correction factors with 0.14ml ion chamber, film dosimetry and TLD measurement. Calculated dose distributions were compared with measured data.

  • PDF

뎁스카메라와 YOLOAddSeg 알고리즘을 이용한 방사선치료환자 미세동작인식 및 실시간 위치보정기술 개발 (Development of Motion Recognition and Real-time Positioning Technology for Radiotherapy Patients Using Depth Camera and YOLOAddSeg Algorithm)

  • 박기용;류규하
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권2호
    • /
    • pp.125-138
    • /
    • 2023
  • The development of AI systems for radiation therapy is important to improve the accuracy, effectiveness, and safety of cancer treatment. The current system has the disadvantage of monitoring patients using CCTV, which can cause errors and mistakes in the treatment process, which can lead to misalignment of radiation. Developed the PMRP system, an AI automation system that uses depth cameras to measure patient's fine movements, segment patient's body into parts, align Z values of depth cameras with Z values, and transmit measured feedback to positioning devices in real time, monitoring errors and treatments. The need for such a system began because the CCTV visual monitoring system could not detect fine movements, Z-direction movements, and body part movements, hindering improvement of radiation therapy performance and increasing the risk of side effects in normal tissues. This study could provide the development of a field of radiotherapy that lags in many parts of the world, along with the economic and social importance of developing an independent platform for radiotherapy devices. This study verified its effectiveness and efficiency with data through phantom experiments, and future studies aim to help improve treatment performance by improving the posture correction mechanism and correcting left and right up and down movements in real time.

DYNAMIC WEDGE의 임상 적용 가능성에 관한 고찰

  • 김영범;정세영;황웅구
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.103-110
    • /
    • 1995
  • Dynamic wedge system has been introduced to modify the beam profile and to make homogeneous isodose curves in the mass of irregular shape. Before the clinical use of dynamic wedge, several factors such as wedge transmission factor, dose profile, percent depth dose, and wedge angle have to be measured quantitatively. Film dosimetry is used to evaluate these factors in this study. A comparison of the result of the dynamic wedge to physical wedge system is made. A positive result for the application of the dynamic wedge to clinic is derived even though there is a limitation in accuracy of the dosimetry system used. To measure all factors quantitatively, more accurate dosimetry systems are required.

  • PDF

전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구 (The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy)

  • 박시온;곽근탁;박주경;이승훈;김양수;김정수;권형철;이선영
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.57-65
    • /
    • 2019
  • 목 적: 전자선 치료에서 저 용융점 납합금과 순수 납을 이용한 차폐 시 두께증가에 따른 블록 가장자리의 산란선 영향을 알아보고자 한다. 대상 및 방법: $10{\times}10cm^2$ 어플리케이터의 Insert Frame 절반을 차폐하도록 블록을 제작하였고, 두께는 각 재질당 3, 5, 10, 15, 20 (mm)로 하였다. 공통 조건을 에너지 6 MeV, 선량률 300 MU/Min, 갠트리 각도 0, 부여선량 100 MU으로 설정하였고, 블록의 위치와 측정점의 위치, 블록재질을 각각 달리하여 블록 두께증가에 따른 상대적인 산란비율을 평행평판형 전리함과 고체팬텀으로 측정하였다. 결 과: (측정 깊이 / 블록 위치 / 블록 재질)이 (표면 / 어플리케이터 / 순수 납)일 때 블록 두께가 3, 5, 10, 15, 20 (mm) 순으로 증가함에 따라 상대선량은 15.33 nC, 15.28 nC, 15.08 nC, 15.05 nC, 15.07 nC로 측정되었다. (표면 / 어플리케이터 / 합금 납)일 때 15.19 nC, 15.25 nC, 15.15 nC, 14.96 nC, 15.15 nC로 측정되었다. (표면 / 팬텀 위 / 순수 납)일 때 15.62 nC, 15.59 nC, 15.53 nC, 15.48 nC, 15.34 nC로 측정되었다. (표면 / 팬텀 위 / 합금 납)일 때 15.56 nC, 15.55 nC, 15.51 nC, 15.42 nC, 15.39 nC로 측정되었다. (심부 / 어플리케이터 / 순수 납)일 때 16.70 nC, 16.84 nC, 16.72 nC, 16.88 nC, 16.90 nC로 측정되었다. (심부 / 어플리케이터 / 합금 납)일 때 16.83 nC, 17.12 nC, 16.89 nC, 16.77 nC, 16.52 nC로 측정되었다. (심부 / 팬텀 위 / 순수 납)일 때 17.41 nC, 17.45 nC, 17.34 nC, 17.42 nC, 17.25 nC로 측정되었다. (심부 / 팬텀 위 / 합금 납)일 때 17.45 nC, 17.44 nC, 17.47 nC, 17.43 nC, 17.35 nC로 측정되었다. 결 론: 차폐블록을 이용하여 전자선 치료를 진행할 때 블록위치는 환자 체표면보다는 어플리케이터에 삽입하고 두께는 각 사용 에너지에 해당되는 최소 적정차폐두께로 제작해야 한다. 또한 블록 가장자리 경계선으로부터 떨어진 거리에 따라 변화하는 산란선의 영향을 충분히 고려하여 치료를 시행하는 것이 바람직하다고 사료된다.

동적 세기조절방사선치료에서 깊이에 따른 DLG변화 분석 (Evaluation of Dosimetric Leaf Gap (DLG) at Different Depths for Dynamic IMRT)

  • 장경환;곽정원;조병철;정치영;배재범;윤상민;이상욱
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.153-159
    • /
    • 2015
  • 본 연구에서는 동적 세기조절방사선치료에서 깊이에 따른 DLG (Dosimetric Leaf Gap)의 변화가 치료계획시스템에서의 선량계산의 정확성에 미치는 영향을 평가하고자 하였다. 6 MV와 15 MV광자선에 대하여 동일한 SAD 조건하에 4개의 다른 깊이(2 cm, 5 cm, 10 cm, 15 cm)에서 측정된 다엽콜리메이터의 투과계수와 DLG 값을 치료계획시스템에 적용하여 DLG 측정 과정을 모사하였을 때 계산된 투과계수와 DLG 값들을 각각의 측정값들과 비교하여 분석하였다. 이를 위하여 Millenium 120 MLC시스템이 장착 된 단일 선형가속기가 사용되었다. 각각 다른 깊이에서 측정된 DLG와 투과계수 값을 적용하였을 때 치료계획시스템을 이용한 모사에서는 투과계수의 경우 1% 이내로 계산과 측정이 일치함을 보이는 반면에 DLG 값은 15 MV 경우 5% 이내의 차이를 보이고 6 MV에서는 최대 깊이인 15 cm에서 15% 이상 차이가 보였다. 실제의 경우 15 MV 경우 15 cm 깊이까지 DLG의 변화에 의한 실험과 계산의 차이가 작은 반면 6 MV 경우, 10 cm 이상의 깊이에서는 치료계획 시스템에서 계산된 값이 측정과 크게 차이를 나타냈다. 다엽콜리메이터 투과계수를 기준 조건하에서 측정한 고정된 값을 치료계획시스템에 적용하였을 때 측정 깊이에 따른 고정된 투과계수 값과 변화된 투과계수 값의 차이는 크지는 않지만 종양이 위치하는 깊이에 따라서 선량학적 영향이 나타날 수 있으므로 깊이에 따른 다엽콜리메이터 투과계수 및 DLG 값을 각각의 치료계획에 반영하여 환자 맞춤형 치료계획이 될 수 있도록 해야 할 것이다.

선형가속기 10 MV 광자선에서 산란판(Beam Spoiler) 사용 시 표면선량 변화 (The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator)

  • 배성철;김준호;이철수
    • 대한방사선치료학회지
    • /
    • 제18권1호
    • /
    • pp.21-28
    • /
    • 2006
  • 목 적: 10 MV X-선의 선형가속기를 이용하여 두경부종양 및 임파선 전이 환자를 치료할 시 피부표면 종양에 균일한 선량을 부여하기 위하여 조직 등가물질로 산란판을 제작하였으며 팬톰을 이용한 피부선량을 측정하여 그 효과를 평가하였다. 대상 및 방법: 조직 등가 물질인 lucite로 산란판을 제작하여 가속기의 콜리메이터와 피부사이에 부착하였으며 조사면적의 크기($5{\times}5{\sim}30{\times}30cm^2$)와 산란판 두께 및 피부와 산란판 간의 거리에 따른 피부 및 체표 0.4 cm에서의 선량 변화를 측정하였다. 또한 자체 제작한 산란 판의 체표 선량 증강 효과를 평가하기위해 볼루스를 이용한 체표 선량을 측정하여 그 효과를 비교하였다. 결 과: 10 MV X-선 선형가속기와 피부 사이에 산란판을 설치하여 피부선량이 증가 되었으며 산란판의 위치에 따라 피부선량이 변화되었고, 0.4 cm 깊이의 선량과 최대선량지점이 피부표면쪽으로 이동하였다. 산란판이 일정할 경우 조사면적이 커질수록 표면선량이 증가하고 최대 선량점은 피부표면 방향으로 이동하였다. 또한 산란판의 두께가 두꺼울수록 표면선량이 증가하고 최대 선량점은 피부표면 방향으로 이동하였다. 결 론: 10 MV X-선을 이용하여 두경부 종양 및 임파선 전이 암을 치료할 경우 산란판을 이용하여 이차산란 전자를 피부표면 앞에서 발생시킴으로써 표면근접부의 선량을 증가시켜 종양부위에 균일한 선량을 조사할 수 있었다. 본 연구에서는 조사면적에 따라 적정 산란판 조건을 찾아 임상에서 유용하게 사용하고자 하였으며, 1.2 cm, 1.8 cm 두께의 산란판을 피부로부터 7 cm에 위치 시켰을때 $10{\times}10cm^2$ 조사면적의 표면선량이 각각 60%, 64%로 측정되었고, 0.4 cm 깊이의 선량이 94%, 94%로 가장 이상적으로 관찰되었다.

  • PDF

다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교 (Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block)

  • 이상욱;오영택;김우철;금기창;윤성익;김현수;박원;추성실;김귀언
    • Radiation Oncology Journal
    • /
    • 제13권4호
    • /
    • pp.391-396
    • /
    • 1995
  • 목적 : 컴퓨터의 발달에 힘입어 3-D Conformal Radiotherapy(3-D CRT)가 가능하게 되었고 3-D CRT를 위해서는 다엽콜리메이터(MLC)가 필수적인 장치이다. 이에 본 저자들은 MLC 사용시 반그림자(Penumbra)의 크기와 그 특성을 알아보고 기존의 합금납(lead alloy block)을 사용할 때의 반그림자와 차이를 비교 분석하여 임상에서 다엽콜리메이터(MLC)의 이용에 도움이 되고자 본 연구를 계획하였다. 방법 : MLC와 합금납의 반그림자를 측정하기 위해 6MV 와 10MV 에너지의 방사선을 이용하여 필름선량분석을 시행하였다. 필름에 각에너지의 dmax와 10cm 두께의 폴리스탈린 판톰을 올려 놓고 측정하였고, MLC의 종단면과 조사면의 y축과 이루는 각도를 변화시키면서 Effective penumbra($20{\%}-80{\%}$)와 $10{\%}-90{\%}$ 반그림자를 측정하였다. 결과 : MLC의 각도가 0o에서 75o로 증가함에 따라 반그림자의 크기가 증가 하였고, 반그림자 영역에서 등선량곡선의 부채살모양이 심화 되었다. dmax에서 보다 10cm 깊이에서 반그림자의 크기가 약간 증가하였고, 에너지가 증가 하면서 약간 반그림자가 커지는 경향성만 보였다. 합금납을 사용할 경우의 반그림자보다 MLC를 사용할경우 최대 4.8mm가 더 크게 측정되었다. 결론 : 3-D CRT를 시행함에 있어서 반그림자 영역에서는 기존의 합금납 차폐물을 대신하여 MLC를 사용하여도 무방하리라는 결론을 얻을 수 있었다.

  • PDF