• Title/Summary/Keyword: Depth dose

Search Result 509, Processing Time 0.027 seconds

Fast Neutron Beam Dosimetry (속중성자선의 선량분포에 관한 연구)

  • Lee Hyo Nam;Ji Young Hoon;Ji Kwang Soo;Lee Dong Han
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.71-81
    • /
    • 1997
  • I. Objective and Importance of the Project We have been using MC-50 cyclotron and NT-50 neutron therapy machine for treating cancer patients since 1986 at Korea Cancer Center Hospital. It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine (Task Group 18), European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induce the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. II. Scope and Contents of the Project For establishing a unique technique of measurement and inventing a standard method of measurement of fast neutron beam, 1. to grasp the physical characteristics of neutron therapy machine 2. to study the principles for measrement of fast neutron beam 3. to get the dose distribution (dose rate, percent-depth dose, flatness etc) throught the actual measurement 4. to compare our data with those being cited world-widely.

  • PDF

Space Radiation Shielding Calculation by Approximate Model for LEO Satellites

  • Shin Myung-Won;Kim Myung-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Two approximate methods for a cosmic radiation shielding calculation in low earth orbits were developed and assessed. Those are a sectoring method and a chord-length distribution method. In order to simulate a change in cosmic radiation environments along the satellite mission trajectory, IGRF model and AP(E)-8 model were used. When the approximate methods were applied, the geometrical model of satellite structure was approximated as one-dimensional slabs, and a pre-calculated dose-depth conversion function was introduced to simplify the dose calculation process. Verification was performed with mission data of KITSAT-1 and the calculated results were also compared with detailed 3-dimensional calculation results using Monte Carlo calculation. Dose results from the approximate methods were conservatively higher than Monte Carlo results, but were lower than experimental data in total dose rate. Differences between calculation and experimental data seem to come from the AP-8 model, for which it is reported that fluxes of proton are underestimated. We confirmed that the developed approximate method can be applied to commercial satellite shielding calculations. It is also found that commercial products of semi-conductors can be damaged due to total ionizing dose under LEO radiation environment. An intensive shielding analysis should be taken into account when commercial devices are used.

Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons

  • Hyun Kim;Dong Hyeok Jeong;Sang Koo Kang;Manwoo Lee;Heuijin Lim;Sang Jin Lee;Kyoung Won Jang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3417-3422
    • /
    • 2023
  • Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus® chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation.

An Experimental Study on the Shear Behavior of High Strength Concrete Deep Beam (고강도 철근 콘크리트 깊은 보의 전단거동에 관한 실험적 연구)

  • 함영삼;양근혁;이영호;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.897-902
    • /
    • 2001
  • The purpose of this experimental study is to investigate the shear behavior of high-strength concrete deep beam and to grasp the conservatism of ACI Building Code. Experimental results on 12 deep beams under two equal symmetrically placed point loads are reported. Main variables are vertical and horizontal web reinforcement and shear span-to-overall depth ratio. Test results indicated that web reinforcement dose not affect on formation of inclined cracks but shear span-to-overall depth ratio affect on inclined shear cracks and ultimate shear strength. Addition of vertical web reinforcement improves ultimate shear strength of H.S.C. deep beams that shear span-to-overall depth ratio is 1.0. Considerable increase in ultimate shear strength of H.S.C. deep beams with increasing horizontal web reinforcement that shear span-to-overall depth ratio is 0.5. Especially with increasing concrete strength($f_{ck}$) the ACI code is conservative in estamating the ultimate shear strength of deep beams.

  • PDF

Study on Structural properties of As Ion -Implanted Si (As이온이 주입된 Si의 구조적 특성 연구)

  • 믄영희;배인호;김말문;한병국;김창수;홍승수;신용현;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.3
    • /
    • pp.218-222
    • /
    • 1996
  • STrained layers and strain depth profile of high dose As ion implanted (100) si wafer annealed at various temperatures have been investigated by means of X-ray double crystal diffractometry (X-ray DCD). The results obtained by x-ray rocking curve analysis showed a defect layer at the original amorphous /crystalline interface of 1400$\AA$ depth. In addition arsenic ion concentrtion profiles and defect distributions in depth were obtained by the SIMS and TRIM -code simulation . the positive strain depth profile determined from the rocking curve analysis were only presented under 0.14 $\mu$m from the surface for samples ananelaed at $600^{\circ}C$. The results was shown that the thickness of amprphous layer is 0.14 $\mu$m indirectry, and it was good agreement with the TRIM -Code simulation. Additionally, it could be thought that the positive strain have been affected residual intersitial atoms under the amorphous/crystalline interface formed by ion implantation.

  • PDF

Perturbation of Dose Distributions for Air Cavities in Tissue by High Energy Electron (고(高) 에너지 전자선(電子線) 치료시(治療時) 체내(體內) 공동(空洞)으로 인(因)한 선량분포(線量分布)의 변동(變動))

  • Chu, S.S.;Lee, D.H.;Choi, B.S.
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.22-30
    • /
    • 1976
  • The perturbation of dose distribution adjacent to cavities in high energy electron has shown that the percentage of dose increase varies markedly as a function of the build-up layer, the length and thickness of the cavities, and the electron energy. The dose distribution showed that cavities similar in size to those encountered in the head and neck measured by industrial film dosimetry and corrected by ionization chambers. The most increased doses by measuring are resulted in a localized dose of up to 130% of that measured at the depth of maximum dose within a homogeneous tissue equivalent phantom. The measured values and correction factors of dose perturbation due to air cavities showed in diagrams and would be summarized as follows. 1. In $8{\sim}12MeV$ electron beams, the most marked dose is observed when the build-up layer thickness is 0.5cm and cavity volume is $2{\times}2{\times}2cm^3$. 2. The highest dose point is located under cavity when the energy is increased and cavity length is longer. 3. The cavity length at which the maximum percentage dose occurs decreases with increasing energy. 4. The highest percentage cavity doses are obtained when the energy is high, the build-up layer is thin, the thickness of the cavity is large, and the length of the cavity is approximately 1 to 3cm. 5. The doses of upper portion of cavity are less than the standard dose distribution as 5 to 10%. 6. The maximum range of electron beam are extended as much as thickness of cavity. 7. A cavity having a length of 5cm closely approximates a cavity of infinite length.

  • PDF

Automated Determination of Prostate Depth for Planning in Proton Beam Treatment (양성자치료에서의 종양의 위치 및 깊이 검출 자동화 시스템에 관한 연구)

  • Cheong, Min-Ho;Yoon, Myong-Geun;Kim, Jin-Sung;Shin, Dong-Ho;Park, Sung-Yong;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.180-190
    • /
    • 2009
  • Depth of prostate volume from the skin can vary due to intra-fractional and inter-fractional movements, which may result in dose reduction to the target volume. Therefore we evaluated the feasibility of automated depth determination-based adaptive proton therapy to minimize the effect of inter-fractional movements of the prostate. Based on the center of mass method, using three fiducial gold markers in the prostate target volume, we determined the differences between the planning and treatment stages in prostate target location. Thirty-eight images from 10 patients were used to assess the automated depth determination method, which was also compared with manually determined depth values. The mean differences in prostate target location for the left to right (LR) and superior to inferior (SI) directions were 0.9 mm and 2.3 mm, respectively, while the maximum discrepancies in location in individual patients were 3.3 mm and 7.2 mm, respectively. In the bilateral beam configuration, the difference in the LR direction represents the target depth changes from 0.7 mm to 3.3 mm in this study. We found that 42.1%, 26.3% and 2.6% of thirty-eight inspections showed greater than 1 mm, 2 mm and 3 mm depth differences, respectively, between the planning and treatment stages. Adaptive planning based on automated depth determination may be a solution for inter-fractional movements of the prostate in proton therapy since small depth changes of the target can significantly reduce target dose during proton treatment of prostate cancer patients.

  • PDF

Measurement of Dose Distribution in Small Fields of NEC LINAC 6 MVX Using Films and Tissue Equivalent Phantoms (필름 및 tissue equivalent 팬톰을 이용한 NEC LINAC 6 MVX 소조사면에 대한 선량분포 측정)

  • Suh, Tae-Suk;Park, Dong-Rak;Choe, Bo-Young;Yoon, Sei-Chul;Jang, Hong-Seok;Park, Il-Bong;Kim, Moon-Chan;Bahk, Yong-Whee;Shin, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.9-17
    • /
    • 1993
  • The purpose of this paper is to develop a simple system to measure dose distribution in small fields of NEC LINAC 6 MVX using film and solid water instead of ion chamber and water phantom. Specific quantities measured include percent depth dose (PDD), off-axis ratio (OAR). We produced square fields of 1 to 3cm in perimeter in 1cm steps measured at SAD of 80cm. The PDD and OAR measured by film was compared with measurement made with ion chamber. We calculated the TMR from the basic PDD data using the conversion formula. The trends of our measured beam data and philips LINAC are similar each other. The measurement for the small field using film and solid water was simple. Hand-made film phantom was especially useful to measure OARs for the stereotactic radiosurgery.

  • PDF

Beta Dosimetry in Intraperitoneal Administration of 166Ho-chitosan Complex (166Ho-chitosan 복합체의 복강 내 투여를 위한 베타선 흡수선량 평가)

  • Kim, Eun-Hee;Lim, Sang-Moo;Park, Kyung-Bae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.99-108
    • /
    • 1998
  • Intraperitoneal administration of radioisotopes is suggested to treat the metastatic ovarian cancer in the peritoneal cavity. Administering beta-emitting radioisotopes into the peritoneal cavity allows the maximum energy delivery to the cancerous cells of the peritoneal wall surface while sparing the normal cells located in deep site of the peritoneal wall. In this study, dose estimates of the peritoneal wall are provided to be used for prescribing the amount of $^{166}Ho$-chitosan complex administered. The $^{166}Ho$-chitosan complex diffused in the peritoneal fluid may attach to the peritoneal wall surface. The attachment fraction of $^{166}Ho$-chitosan complex to the peritoneal wall surface is obtained by simulating the ascites with Fischer rats. Both volume source in the peritoneal fluid and the surface source over the peritoneal wall surface are counted for the contribution to the peritoneal wall dose. The Monte Carlo code EGS4 is used to simulate the energy transfer of the beta particles emitted from $^{166}Ho$. A plane geometrical model of semi-infinite volume describes the peritoneal cavity and the peritoneal wall. A semi-infinite plane of $10{\mu}m$ in thickness at every 1 mm of depth in the peritoneal wall is taken as the target in dose estimation. Greater than 98 percents of attachment fraction has been observed from the experiments with Fischer rats. Given $1.3{\mu}Ci/cm^2$ and $2.4{\mu}Ci/ml$ of uniform activity density, absorbed dose is 123 Gy, 8.59 Gy, 3.00 Gy, 1.03 Gy, and .327 Gy at 0 mm, 1 mm, 2 mm, 3 mm, and 4 mm in depth to the peritoneal wall, respectively.

  • PDF

The effects of low dose doxycycline regimen on gingival crevicular fluid enzyme actmty of diabetic patients with periodontitis and adult periodontitis patients (저용량 독시싸이클린 투여가 당뇨환자 마치 성인성 치주염 환자의 치은열구액내 효소 활성도에 미치는 영향에 관한 비교연구)

  • Jeong, Seong-Nyum;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.4
    • /
    • pp.701-722
    • /
    • 1997
  • It was reported that low dose doxycycline(LDD) regimen could inhibit pathologically elevated collagenase activity in the gingival crevicular fluid of petients with adult periodontitis without producing typical antibiotic side effects. The purpose of this study was to evaluate the effects of LDD regimen(20mg) administered during non-surgical therapy on clinical index and gingival crevicular fluid enzyme activity in diabetics who are at high risk for periodontal disease. Forty-nine subjects having at least two sites with probing pocket depths greater than 4mm were selected. In this double-blind, placebo-controlled study, the patients were administered 20 mg doxycycline capsule or placebo capsule b.i.d. for 2 weeks. Clinical parameters of dental plaque, gingival inflammation, probing pocket depth and probing attachment level were assessed at week 0, 2, 4, and 8. Gingival crevicular fluid samples were collected at the same time to evaluate the activities of collagenase and elastase. Clinical parameters and elastase activity were significantly reduced in all groups compared to the baseline value after treatment. Significantly greater reduction in pocket depth and gain in attachment level was shown in the LDD-administered group compared to placebo group in both adult periodontitis and diabetic patients. Total collagenase activity was also reduced significantly in all groups after treatment, but the greater reduction was seen in the LDD-administered diabetics group compared to relevant placebo group(at 4, 8week). Significantly greater reduction in active collagenase activity was also seen in the LDD-administered group compared to placebo group in diabetic patients(at 2, 4, 8week). These results indicated that use of low dose doxycycline could be aueseful adjunct to instrumentation therapy in the management of diabetic patient with periodontitis as well as adult periodontitis patient.

  • PDF