• Title/Summary/Keyword: Depth Extraction

Search Result 397, Processing Time 0.029 seconds

Water Quality Elements Extraction of Lake by the Landsat TM Images (Landsat TM 영상에 의한 호수의 수질인자 추출)

  • 최승필;양인태
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.2
    • /
    • pp.225-233
    • /
    • 1998
  • It is necessary to check the water quality of the lake on a continuous basis to determine the appearance of water pollution; however, it not only takes much time and expenses but it is considerably difficult to investigate the wide range of the area. If we use the remote sensing technique through the use of satellites, the status of water quality can be checked covering many wide areas simultaneously; and because the same area can be measured on a periodic basis, it is extremely effective in investigating the water quality. Furthermore, as some of the Landsat sensors carry characteristics which sense objects according to wave length, the distribution of water quality can be checked relatively accurately within a short period of time, while its image can be displayed in color. Hence, this research has attempted to extract water quality elements, such as transparency, water depth, and surface water temperature by utilizing the satellite data, and has prepared the water quality distribution image map of the Lake Hwajinpo by presenting the related empirical formula of the water quality elements. If the water quality distribution image map is prepared after extracting the water quality elements from the DN of the Landsat TM image and then carrying out TIN analysis through the use of GIS, relatively more accurate pattern can be learned covering a wide rage of area than the pattern presented based on the value obtained from actual observation.

  • PDF

Displacement pattern of the anterior segment using antero-posterior lingual retractor combined with a palatal plate

  • Seo, Kyung-Won;Kwon, Soon-Yong;Kim, Kyung A;Park, Ki-Ho;Kim, Seong-Hun;Ahn, Hyo-Won;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.289-298
    • /
    • 2015
  • Objective: To evaluate and compare the effects of two appliances on the en masse retraction of the anterior teeth anchored by temporary skeletal anchorage devices (TSADs). Methods: The sample comprised 46 nongrowing hyperdivergent adult patients who planned to undergo upper first premolar extraction using lingual retractors. They were divided into three groups, based on the lingual appliance used: the C-lingual retractor (CLR) group (group 1, n = 16) and two antero-posterior lingual retractor (APLR) groups (n = 30, groups 2 and 3). The APLR group was divided by the posterior tube angulation; posterior tube parallel to the occlusal plane (group 2, n = 15) and distally tipped tube (group 3, n = 15). A retrospective clinical investigation of the skeletal, dental, and soft tissue relationships was performed using lateral cephalometric radiographs obtained pretreatment and post en masse retraction of the anterior teeth. Results: All groups achieved significant incisor and canine retraction. The upper posterior teeth did not drift significantly during the retraction period. The APLR group had less angulation change in the anterior dentition, compared to the CLR group. By changing the tube angulation in the APLR, the intrusive force significantly increased in the distally tipped tube of group 3 patients and remarkably reduced the occlusal plane angle. Conclusions: Compared to the CLR, the APLR provides better anterior torque control and canine tipping while achieving bodily translation. Furthermore, changing the tube angulation will affect the amount of incisor intrusion, even in patients with similar palatal vault depth, without the need for additional TSADs.

Phosphorus Speciation and Bioavailability in Intertidal Sediments of Keunso Bay, Yellow Sea During Summer and Winter (서해 근소만 조간대 퇴적물에서 여름과 겨울에 인의 존재형태)

  • Kim, Dong-Seon;Kim, Kyung-Hee
    • Ocean and Polar Research
    • /
    • v.32 no.3
    • /
    • pp.177-186
    • /
    • 2010
  • A sequential extraction technique was used to study sediment phosphorus speciation and its relative importance in the intertidal flat of Keunso Bay during summer and winter for a better understanding of the phosphorus cycle and bioavailability in intertidal sediments. Loosely sorbed P contents were the lowest among the five P-pools and showed little seasonal or spatial variation. Although Fe-bound P contents were almost constant in winter, they decreased rapidly with sediment depth in summer. The dissolution of Fe oxides, used as an oxidant for the anaerobic respiration, ascribed the rapid decrease of Fe-bound P in summer. Al-bound P contents displayed little seasonal variation, but showed a large spatial variation, with higher values in the upper intertidal flat. Comprising about 50% of total P, Ca-bound P contents were the highest among the five P-pools. Ca-bound P contents were higher in winter than summer, but did not exhibit a clear spatial variation. Organic P contents were higher in summer than winter, which was associated with higher primary production and clam biomass in summer. Organic P contents were higher in the lower intertidal flat than the upper intertidal flat. In Keunso Bay, bioavailable P contents of the intertidal flat comprising about one third of total P ranged from 2.41 to 5.09 ${\mu}molg^{-1}$ in summer and 3.82 to 5.29 ${\mu}molg^{-1}$ in winter. The bioavailability of P contents was higher in the lower intertidal flat than the upper intertidal flat, which was attributed to the large clam production in the lower intertidal flat.

Interactive VFX System for TV Virtual Studio (TV 가상 스튜디오용 인터랙티브 VFX 시스템)

  • Byun, Hae Won
    • Journal of the Korea Computer Graphics Society
    • /
    • v.21 no.5
    • /
    • pp.21-27
    • /
    • 2015
  • In this paper, we presents visual effect(water, fire, smoke) simulation and interaction system for TV virtual studio. TV virtual studio seamlessly synthesizes CG background and a live performer standing on a TV green studio. Previous virtual studios focus on the registration of CG background and a performer in real world. In contrast to the previous systems, we can afford to make new types of TV scenes more easily by simulating interactive visual effects according to a performer. This requires the extraction of the performer motion to be transformed 3D vector field and simulate fluids by applying the vector field to Navier Stokes equation. To add realism to water VFX simulation and interaction, we also simulate the dynamic behavior of splashing fluids on the water surface. To provide real-time recording of TV programs, real-time VFX simulation and interaction is presented through a GPU programming. Experimental results show this system can be used practically for realizing water, fire, smoke VFX simulation and the dynamic behavior simulation of fish flocks inside ocean.

Effect of water jetting parameters on the penetration behavior of jack-up spudcan in surficial sand condition

  • Han, Dong-Seop;Kim, Seung-Jun;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-19
    • /
    • 2015
  • The water jetting system for a jack-up spudcan requires the suitable design considering the platform/spudcan particulars, environments, and soil conditions, either the surficial clay or surficial sand. The usage of water jetting depends critically on soil conditions. The water jetting is usually used for the smooth and fast extraction of the spudcan in the surficial clay condition. It is also required for inserting spudcan up to the required depth in the surficial sand condition, which is investigated in this paper. Especially, it should be very careful to use the water jetting during an installation of spudcan in the surficial sand condition, because there is a risk of overturning accident related to the punch-through. Therefore, in this study, the effect of water jetting flow rate and time on the change of soil properties and penetration resistance is analyzed to better understand their interactions and correlations when inserting the spudcan with water jetting in surficial sand condition. For the investigation, a wind turbine installation jack-up rig (WTIJ) is selected as the target platform and the multi layered soil (surficial sand overlaying clays) is considered as the soil condition. The environmental loading and soil-structure interaction (SSI) analysis are performed by using CHARM3D and ANSYS. This kind of investigation and simulation is needed to decide the proper water jetting flow rate and time of spudcan for the given design condition.

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

Newly Modified Watershed Algorithm Determining Dynamic Region Merging or Watershed Line in the Flooding Process (담수과정에서 동적 영역 병합과 분수령선을 결정하는 개선된 분수령 알고리즘)

  • Kim, Sang-Gon;Jeoune, Dae-Seong;Lee, Jae-Do;Kim, Hwi-Won;Yoon, Young-Woo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.6
    • /
    • pp.113-119
    • /
    • 2001
  • In this paper, we propose an improved watershed algorithm that resolves the oversegmentation problem shown in the previous watershed algorithm and its modifications when the spatial video segmentation is performed. The principal idea of the proposed algorithm is merging the shallow catchment basin whose depth is less than a given threshold into the deeper one during flooding step. In the flooding process, the growth of the existing catchment basins and the extraction of newly flooded ones are accomplished. We present the experimental results using several MPEG test sequences in the last part of the paper. As a consequence, the proposed algorithm shows good segmentation results according to the thresholds applied by adding very small amount of calculations.

  • PDF

Processing Underwater Images for Information Extraction of Deep Seabed Manganese Nodules as New Energy Resource (미래 에너지 자원탐사를 위한 수중카메라 영상처리에 의한 심해저 망간단괴 정보추출)

  • Lee, Dong-Cheon;Yun, Seong-Goo;Lee, Young-Wook;Ko, Young-Tak;Park, Cheong-Kee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.6
    • /
    • pp.679-688
    • /
    • 2009
  • Worldwide exploring and research for manganese nodules, as new energy resource, distributed on the deep seabed have progressed recently. Korea Ocean Research & Development Institute(KORDI) is a central organization to exploit the manganese nodules in the Pacific Ocean with 5,000m depth. Precise exploration is required for estimating amount of recoverable deposit, and this task could be accomplished by processing digital image processing techniques to the images taken by underwater camera system. Image processing and analysis provide information about characteristics of distribution of the manganese nodules. This study proposed effective methods to remove vignetting effect to improve image quality and to extract information. The results show more reliable information could be obtained by removing the vignetting and feasibility of utilizing image processing techniques for exploring the manganese nodules.

A STUDY OF EFFECTS OF BONE MORPHOGENETIC PROTEIN BONE REGENERATION OF IMPLANTS IN DOGS (성견에서 임프란트 매식시 골형성단백 사용에 따른 골재생에 관한 연구)

  • Jo Jin-Hee;Vang Mong-Sook;Lee Jong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.4
    • /
    • pp.593-607
    • /
    • 1994
  • The purpose of this study is to evaluate the effect of the bone morphogenetic protein, bone matrix gelatin and collagen matrix on the amount and shape of generating new bone adjacent to the implant. Implants were inserted in the mandible of adult dogs at 2 months after teeth extraction. Artificial bony defects, 3mm in width and 4mm in depth were made at the mesial and distal side of implant. Experimental groups were divided into three groups ; Group 1 : Defects filled with collagen matrix and bone morphogenetic protein, Group 2 : Defects filled with bone matrix gelatin. Control group : Defects filled with only collagen matrix. After implantation, the animals were sacrificed at 1,3,5 and 10 weeks for light microscopic examination. For the fluorescent microscopic examination. each tertracycline Hcl and calcein were injected at 1, 3, 5, 8 and 10 weeks after implantation. The results obtained were as follows : 1. The molecular weight of bovine BMP was about 18,100 by hydroxyapatite chromatography. 2. Osseointegration was observed in experimental groups 1 & 2, and BMG and BMP had an excellent bone forming capability as a filling materials to the repair of the bone defects. 3. The degree of healing of bone defect area, the experimental group 1 showed more prominent bone formation than control group, and the control group showed fibrous connective tissue between the implant and the bone. 4. In the fluorescent microscopic findings, bone remodelling was observed regenerative lamellar bone at defect area in experimental group 1, and partial remodelling in experimental group 2, In the control group, fibrous connective tissue was observed between the implant and bone surface and sign of remodelling was not apperaed. Above results suggest that BMP has rapid osteoinductive property and can be used clinically as a bone substitute on bone defects around implants.

  • PDF

A STUDY OF CHIDED TISSUE REGENERATION FOR IMMEDIATE IMPLANTATION WITH/WITHOUT HA AUGMENTATION : A STUDY IN DOGS (성견에서 발치 직후 Titanium plasma sprayed IMZ 임프란트 이식시 조직유도 재생술에 따른 골 재생력에 관한 연구)

  • Hwang Hie-Seong;Chung Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.361-378
    • /
    • 1992
  • The purpose of this investigation was to evaluate the effect of the porous hydroxyapatite particles (Interpore $200^{(R)}$) and guided tissue regeneration membrane ($Gore-Tex^{TM}$ augmentation material) on amount and shape of generating new bone adjacent to implant. Implants were placed immediately after extraction in the bilateral 3rd, 4th premolars of the mandible of the adult dogs. In all experimental groups, artificial bony defects were formed at the buccal cortex area, 3.3mm in width and 3.0mm in depth. In the control group : sutured without HA particles & membranes after placing implants, the experimental group 1 : membrane was place over the artificial bony defect, the experimental group 2 : bony defect was filled with HA particles and covered with membrane. The examination of bone-implant interfaces using light microscope and fluorescent microscope concluded as follows. 1. In all three experimental groups, osseointegration was observed without epithelial migration. 2. In the healing degree of bony defect area, the experimental group 1, 2 showed more prominent healing than control group, and the experimental group 1 showed the most excellent bone formation. 3. In fluorescent microscopic finding, bone remodeling was observed in regenerated bone tissue at defect area of experimental group 1, but in experimental group 2, irregular, discontinuous linear fluorescence was observed at the lower portion of defect area and sign of bone remodeling was weak.

  • PDF