• Title/Summary/Keyword: Depth Calculation

Search Result 573, Processing Time 0.03 seconds

Analysis on the optimized depth of 3D displays without an accommodation error

  • Choi, Hee-Jin;Kim, Joo-Hwan;Park, Jae-Byung;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1811-1814
    • /
    • 2007
  • Accommodation error is one of the main factors that degrade the comfort while watching stereoscopic 3D images. We analyze the limit of the expressible 3D depth without an accommodation error using the human factor information and wave optical calculation under Fresnel approximation.

  • PDF

Improvement of Calculation Accuracy in the Electron Monte Carlo Algorithm with Optional Air Profile Measurements

  • Sung, Jiwon;Jin, Hyeongmin;Kim, Jeongho;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.163-171
    • /
    • 2020
  • Purpose: In this study, the accuracies of electron Monte Carlo (eMC) calculation algorithms were evaluated to determine whether electron beams were modeled by optional air profiles (APs) designed for each applicator size. Methods: Electron beams with the energies of 6, 9, 12, and 16 MeV for VitalBeam (Varian Medical System, Palo Alto, CA, USA) and 6, 9, 12, 16, and 20 MeV for Clinac iX (Varian Medical System) were used. Optional APs were measured at the source-to-detector distance of 95 cm with jaw openings appropriate for each machine, electron beam energy, and applicator size. The measured optional APs were postprocessed and converted into the w2CAD format. Then, the electron beams were modeled and calculated with and without optional APs. Measured profiles, percentage depth doses, penumbras with respect to each machine, and energy were compared to calculated dose distributions. Results: For VitalBeam, the profile differences between the measurement and calculation were reduced by 0.35%, 0.15%, 0.14%, and 0.38% at 6, 9, 12, and 16 MeV, respectively, when the beams were modeled with APs. For Clinac iX, the differences were decreased by 0.16%, -0.31%, 0.94%, 0.42%, and 0.74%, at 6, 9, 12, 16, and 20 MeV, respectively, with the insertion of APs. Of note, no significant improvements in penumbra and percentage depth dose were observed, although the beam models were configured with APs. Conclusions: The accuracy of the eMC calculation can be improved in profiles when electron beams are modeled with optional APs.

Effects of Critical Minimum Depth in the Coastal Region on Storm Surges using a Three-Dimensional Numerical Experiment (폭풍해일 예측 수치실험에 미치는 연안역 임계최소수심의 영향)

  • Hong, Chul-Hoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.2
    • /
    • pp.168-173
    • /
    • 2014
  • The effect of critical minimum depth in the coastal region on storm surges was examined using a three-dimensional primitive equation model (POM). Case studies using numerical experiments in a small coastal bay in the southern sea of Korea (Hanam Bay) have examined the 'critical depth' (CD) that stabilizes the numerical calculations. Dependence of the CD of typhoon tracks and tidal components such as M2, S2, O1, and K1 were examined. The model results clearly demonstrated that the numerically unstable state of the calculation was caused by the coarse resolution of sea surface elevation.

Prediction of Wear Depth of SG Tube based on Types of Wear Scar (전열관의 마모 체적형상에 따른 마모깊이 예측)

  • Ryu, Ki-Wahn;Kim, Hyung-Jin;Park, Chi-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.475-478
    • /
    • 2005
  • Calculation of wear depth with regard to the wear topology is peformed numerically Four typical wear topology, that is round, crescent, flat, and diamond types are adopted to represent the configuration of wear volume. Diamond and flat types are the most severe topology for wear depth history, whereas round and crescent types have small increasing rate of wear depth to the wear volume. Based on this study we can guess that the most severe wear phenomena happens to be upper side of U-tubes in the KSNP SG, because flat or diamond wear will be generated by the wearing motion between tubes and diagonal, vertical, horizontal strips. The misalignment of tube at the stage of manufacturing or distortion of upper structure due to the thermal expansion or vibration of upper structure such as diagonal, vertical, and horizontal strips will be one of the main causes of flat or diamond wear.

  • PDF

Improvement and Verification of the Wear Volume Calculation

  • Kim, Hyung-Kyu;Lee, Young-Ho
    • KSTLE International Journal
    • /
    • v.6 no.1
    • /
    • pp.21-27
    • /
    • 2005
  • A technique for a wear volume calculation is improved and verified in this research. The wear profile data measured by a surface roughness tester is used. The present technique uses a data flattening, the FFT and the windowing procedure, which is used for a general signal processing. The measured value of an average roughness of an unworn surfnce is used for the baseline of the integration for the volume calculation. The improvements from the previous technique are the procedures of the data flattening and the determination of a baseline. It is found that the flattening procedure efnciently manipulates the raw data when the levels of it are not horizontal, which enables us to calculate the volume reasonably well and readily. By comparing it with the weight loss method by using artificial dents, the present method reveals more volume by aroung 3~10%. It is attributed to the protruded region of the specimen and the inaccuracy and data averaging during the weght loss measurement. From a thorough investigation, it is concluded that the present technique can provide an accurate wear volume.

STUDY ON ALGORITHM FOR CALCULATION REMAINING CAPACITY OF INDUSTRIAL LEAD-ACID BATTERY (산업용 연축전지의 잔존용량 산출 알고리즘(Algorithm)에 관한 연구)

  • Lim, Gyu-Ryeong;Chun, Soon-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2187-2189
    • /
    • 2001
  • The proposed algorithm has produced the rules of relationship between the load voltage, current, discharging electric power and ampere-hours, electric power capacity of battery on the basis of the data. Which were acquired through the battery discharging experiment that is defined by the battery's ambient temperature and various load conditions. Especially, by calculating the parameter of second order polynomial equation relation between the remaining capacity and the electric power, the algorithm is proposed adapting for the discharging pattern. And as the depth of discharging is increasing, the calculation-method of electric power is applied to decrease the accumulated error in the calculation method of capacity accumulation. Also, the proposed algorithm has compensated the temperature considering the capacity change of battery to the temperature.

  • PDF

The Calculation of Energy Distributions for Clinical Electron Beams from Mono Energetic Depth dose Data (단일에너지 깊이선량률 자료에 의한 치료용 전자선의 에너지분포 계산)

  • 이정옥;정동혁
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.39-44
    • /
    • 2004
  • The energy distributions for clinically used electron beams from measured and calculated mono energetic depth dose values were calculated. The energy distributions having the minimum difference between the measured and reduced values of depth dose are determined by iterations based on least square method. The nominal energies of 6, 9, 12, 15 MeV clinical electron beams were examined. The Monte Carlo depth dose calculations with determined energy distributions were peformed to evaluate those distributions. In a comparison of the calculated and measured depth dose data, the standard errors are estimated within $\pm$ 3% from surface to R$_{80}$ depth and within $\pm$4% from the surface to near the range for all electron beams. This can be practically applied to determine the energy distributions for clinically used electron beams.

  • PDF

Normal Depth of Best Section (최량수리단면의 등류수심)

  • Yoo, Dong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.6
    • /
    • pp.729-736
    • /
    • 2002
  • The computation of normal depth is one of the most important parts in the design of open channel flow, and the best section is in general the most economic section in the case of constructing artificial open channels. Thus the determination of the normal depth of the best section is the essential item in the design of most open channel flows. To estimate the frictional forces a power law is introduced, which is applicable to most situations in open channel flows. Explicit and consistent forms of equations are deduced for the calculation of normal depth of triangular, rectangular and trapezoidal best sections. Furthermore the equations of normal depth are found to have the same form as those of pipe diameter for the design of pipe flow.

High Energy Photon Beam Modeling Using Transport Theory for Calculation of Absorbed Dose Distribution (흡수 선량 분포의 수송방정식을 이용한 10 MV X-선의 모델)

  • Choi, Dong-Rak;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • A mathematical model is presented for the calculation of the depth absorbed dose in water Phantom irradiated by high energy Photon beam (10MV X-ray), based on transport theory. The parameters of this model are obtained from the experimental values which were simulated by non-linear regression process method. The calculated absorbed dose distribution is extended to 3-D by using trial function from beam profile field sizes, SSD and depth in water phantom irradiated by high energy Photon beam. The calculated values using this model are in good agreement with the measured values.

  • PDF