• 제목/요약/키워드: Deposit distribution

검색결과 234건 처리시간 0.023초

PTA법에 의한 스텔라이트 12 합금 육성층의 특성에 미치는 전류의 영향 (The Effect of Current on Characteristics of Stellite 12 Alloy Overlayer by PTA Process)

  • 정병호;김무길;안용식;김민영;이성열
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.88-94
    • /
    • 2001
  • Stellite 12 alloy-powders were overlaid on 410 stainless steel valve seat using plasma transferred arc(PTA) process. Variation of the microstructure, hardness, wear and corrosion of overlaid deposit with current change was investigated. The deposit showed hypoeutectic microstructure, which was consisted of primary cobalt dendrite and networked $M_7C_3$ type eutectic carbides. As current increased, the amount of eutectic carbide decreased and its dendritic secondary arm spacing increased. Hardness of the deposit was decreased with increase of current. Stress relief heat treatment at $600^{\circ}C$ for two hours resulted in slight increase of hardness in the deposit and showed uniform hardness distribution in base metal without any hardened layer in HAZ. Specific wear decreased with increase of sliding distance. The deposit of high hardness with a lot of eutectic carbide showed relatively low specific wear. Initial corrosion current density of the deposit in 0.1N sulfuric acid was lower than those of 410 stainless steel, and showed a little variation with PTA current.

  • PDF

Costs and Operational Revenue, Loan to Deposit Ratio Against Return on Assets: A Case Study in Indonesia

  • RAJINDRA, Rajindra;GUASMIN, Guasmin;BURHANUDDIN, Burhanuddin;ANGGRAENI, Rasmi Nur
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권5호
    • /
    • pp.109-115
    • /
    • 2021
  • This study aims to examine the effect of Operating Costs and Income, Loan to Deposit Ratio on the Return on Asset (ROA) of Public-Private Foreign Exchange Banks listed on the Indonesia Stock Exchange (IDX) during the 2015-2018 period. This study is a quantitative study using financial reports of Public-Private Foreign Exchange Banks listed on the IDX as a data source. This study's population is 25 Public-Private Foreign Exchange Banks listed on the IDX. This study uses purposive sampling to determine the sample to produce 21 banking companies. Data was analyzed using multiple linear regression methods and descriptive statistics. The F Test calculation results state that all the variables of free operating expenses, operating income, and the loan to deposit ratio simultaneously and significantly affect the return on assets (ROA) variable in Public-Private Foreign Exchange Banks listed on the IDX. This study's results indicate that simultaneously Operational Costs, Operational Income, and Loan to Deposit Ratio have a significant effect on ROA. Operational Costs and Operational Income have a significant negative impact on Return on Assets. The third hypothesis shows that the Loan to Deposit Ratio has a positive and insignificant effect on Return on Assets.

제주도 고산에서의 에어로솔 입경분포별 조성: 1998년 4월 측정 연구 (Aerosol Size Distribution and Composition at Kosan, Cheju Island : Measurements in April 1998)

  • 김용표;배귀남;지준호;진현철;문길주
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.677-685
    • /
    • 1999
  • Aerosol mass size distributions were measured at Kosan, Cheju Island in April 1998 and their compositions were analyzed. Microorifice Uniform Deposit Impactor(MOUDI) was used to collect aerosols. Sulfate and ammonium ions were predominatly present at fine mode of the aerosols while nitrate, chloride, and metal ions were mostly at coarse mode. Based on the size distribution of nitrate, it is suggested that most nitrate were from gas to particle conversion on coarse particles. Non-sea salt(nss) fraction of sulfate accounted for more than 90% of total sulfate mass concentration. In general, ion concentrations in this study are lower than those measured at the same site from the previous studies. Ion balance and chloride ion levels indicates that there had been anthropogenic chloride emission sources near to the site during the measurements.

  • PDF

지역 및 해안거리에 따른 염분오손 분석에 관한 연구 (Analysis of Salt Contamination on the Location and the Distance from the coastline)

  • 김찬영;김동명;권태호;천성남;고동혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.511-512
    • /
    • 2006
  • The salt contamination on the distribution facilities is one of the major concern areas because more than 90% of salt contaminated failure occurs in distribution facilities. The periodic measurement of the Equivalent Salt Deposit Density(ESDD) is essential to manage and operate the power line. The ESDD has taken from the 112 position which is located on the coastline of the Korean Peninsula. The ESDD will be presented with the location and the distance from the coastline.

  • PDF

풍향 및 풍속이 배전설비의 염분오손에 미치는 영향 (The Effect of the Wind Direction and Velocity on the Salt Contamination of the Distribution Facilities)

  • 김찬영;김동명;권태호;천성남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.499-500
    • /
    • 2006
  • The salt contamination on the distribution facilities was investigated with the wind direction and velocity. Most previous researches were concentrated on the measurement of The Equivalent Salt Deposit Density(ESDD) without environmental consideration. The wind direction and velocity of the many environmental conditions are the most important factors to analyze salt contamination. Pohang area which is located on the south and east of the Korean Peninsula was chosen to do this research. This research will present the result of ESDD depending on the wind direction and velocity.

  • PDF

Factors Affecting Satisfaction of Customers' Savings Deposit in the Context of COVID-19: Evidence from Vietnamese Commercial Banks

  • TRAN, Quoc Thinh;TRAN, Mai Uoc;LE, Xuan Thuy
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권10호
    • /
    • pp.369-376
    • /
    • 2020
  • Credit capital from customers' savings deposit (CSD) of banks has an important meaning in the business activities of the banking industry. There are many factors that influence the CSD satisfaction with banks. Certain changes have been made when there are fluctuations due to COVID-19. The article is based on an analysis assessing the factors that influence the CSD satisfaction of Vietnamese commercial banks in the context of COVID-19. The authors use a sample of 1,639 CSD. The results show that there are three variables that positively affect CSD satisfaction, including legal provisions of the Central bank (Legal), policies and mechanisms of commercial banks (Policy), and products of commercial banks (Product). Accordingly, in order to contribute to strengthening this capital mobilization of savings deposit, the Central bank of Vietnam needs to play a pivotal role in the regulations of the banking system to ensure its stability; control well monetary policy, interest rates, and inflation to keep a stable position in the economy; and provide timely financial support packages to enhance the confidence of CSD. Moreover, Vietnamese commercial banks need flexible policies and mechanisms to stimulate CSD; strengthen support on deposit rates for CSD; and diversify products to easily adapt to each CSD's situation.

Factor Affecting Customers Satisfaction About Banking Services: Evidence from Agribank, Vietnam

  • NGUYEN, Dung Thi;NGUYEN, Ha Quang;PHUNG, Hanh My Tran;THAN, Hoang Viet
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제9권6호
    • /
    • pp.373-380
    • /
    • 2022
  • Today, customer satisfaction is the most important issue for Vietnamese banks. There are numerous factors that influence bank customers' satisfaction. The study investigates the factors that influence customer satisfaction with deposit services at the Vietnam Bank for Agriculture and Rural Development (Agribank) in Bac Giang province, Vietnam, and analyses the impact of each component. The authors used 5-point Likert scales to assess whether elements were related to the factors determining consumer satisfaction with Agribank's deposit service. To perform this study, exploratory factor analysis (EFA) and multiple regression were used to find factors determining customer satisfaction with Agribank services. Customers that use deposit services at Agribank in Bac Giang province, Vietnam, provided samples of 300 survey questionnaires for this study. SPSS software is used to examine the data. Customers' satisfaction with Agribank's deposit service is influenced by six factors, including reliability, responsiveness, service capabilities, empathy, tangible means, and service price, according to the study. This finding also offers some recommendations for improving service quality in local Vietnamese banks to gain a competitive advantage.

온라인 자료 식별체계 실태조사를 기반으로 한 납본연계방안 제안 연구 (Study on the Proposal for Deposit Linkage Plan Based on the Survey of Online Material Identification System)

  • 노영희;손애경;이경선;장인호;정영미;차현주
    • 정보관리학회지
    • /
    • 제41권1호
    • /
    • pp.133-162
    • /
    • 2024
  • 디지털화가 급속히 진행됨에 따라, 온라인 자료의 식별 및 관리의 중요성이 대두되고 있다. 특히, 디지털 콘텐츠의 효율적인 유통 및 보존을 위한 체계적인 식별체계의 필요성이 증가하고 있다. 본 연구는 이러한 시대적 요구에 부응하여, 온라인 자료의 식별 및 관리를 위한 현행 식별체계의 실태를 조사하고, 이를 납본과 연계하여 보다 체계적인 관리 및 활용 방안을 모색하는 것을 목적으로 한다. 이를 위해 온라인 자료 식별체계와 발급실태를 조사하고 온라인 자료에 관련된 선행연구를 분석하였다. 분석결과를 기반으로 한 납본 연계방안은 다음과 같이 세 가지로 요약할 수 있다. 첫째, 납본의 우선순위 및 활용성을 위해 납본과 이용의 상호보완 강화, 납본의 우선순위 부여, 납본자료의 활용성 증대 전략이 요구된다. 둘째, 국제표준번호를 기반으로 한 납본 연계 방안으로서, ISBN과 UCI의 연계 납본, 국제표준자료번호와 납본 연계, 국제표준번호와 UCI의 메타데이터연계, UCI와 ICN의 연계 통합, 납본시스템 고도화를 위한 자동화 기술 도입 전략이 요구된다. 셋째, 위에서 제안한 전략들이 그 효과적으로 작용하기 위해서는 정책적인 지원도 같이 이루어져야 할 것이다. 한국서지표준센터의 납본 역할 강화를 포함하여 출판사와의 협력강화, 납본자료에 대한 보상, 납본제도에 대한 인식 제고 및 제도적 보상 등의 측면에서 고려되어야 할 부분이 있다.

분무기용(噴霧機用) Nozzle의 구조(構造)에 관한 연구(硏究) (Study on the Structures of the Nozzle for the Spray)

  • 이상우
    • Journal of Biosystems Engineering
    • /
    • 제18권2호
    • /
    • pp.100-109
    • /
    • 1993
  • The aim of this study was to provide the reasonable data for design of the nozzle which produces finer droplets on the same level of the effective travel distance or which transports droplets to the farther target on the reasonable atomization in comparison with the commercial nozzles being used much in Korean rural areas. Newly designed twin-fluid atomizers with some commercial nozzles were tested in this study, and their results were as follows : 1. The characteristics of the spray deposit distribution of No.1 nozzles for farther target were nearly same in the near or nearer travel distance less than 8m. Therefore it was reasonable to combine the characteristics of the spray deposit distributions of No.2 and No.3 nozzles to those of No.1 nozzle. 2. The effective travel distance was increased with increase of the sectional area of the jet ligament, and the maximum effective travel distance was reached to about 17m. 3. The droplet size was increased with increase of the sectional area of the jet ligament, and the maximum droplet size was produced in the front of the point of the maximum spray deposit distribution. 4. The atomization was excellent in the twin-fluid atomizer in comparison with the hydraulic atomizer and also the effective travel distances were nearly same level in both atomizers.

  • PDF

포천광산(抱川鑛山)의 지질광상(地質鑛床) (Geology and Ore Deposit of Pocheon Iron Mine)

  • 칸다 요무
    • 자원환경지질
    • /
    • 제2권2호
    • /
    • pp.53-67
    • /
    • 1969
  • Magnetite deposit of Pocheon Iron Mine is a contact replacement skarn deposit embedded in the carbonate rocks (limestone and dolomite) which are intruded by granite porphyry. The shape of ore bodies is sweet potato-like and/or irregular massive form; D-ore body, the biggest one is of $180m{\times}40m{\times}200m$ in size. The ore is in general of high grade. The location of the ore bodies is controlled by the fault which strikes north south and dips $60^{\circ}$ to $70^{\circ}$ to the west. A regular distribution of mineralized zones is recognized in order of outward (hanging wall side) from granite porphyry as follows: compact fine-grained skarn, limesilicates, magnetite ore body, marble, limesilicates, pyritized meta-sediments.

  • PDF