• Title/Summary/Keyword: Dependent Sample

Search Result 835, Processing Time 0.029 seconds

A study on selection of tensor spline models (텐서 스플라인 모형 선택에 관한 연구)

  • 구자용
    • The Korean Journal of Applied Statistics
    • /
    • v.5 no.2
    • /
    • pp.181-192
    • /
    • 1992
  • We consider the estimation of the regression surface in generalized linear models based on tensor-product B-splines in a data-dependent way. Our approach is to use maximum likelihood method to estimate the regression function by a function from a space of tensor-product B-splines that have a finite number of knots and are linear in the tails. The knots are placed at selected order statistics of each coordinate of the sample data. The number of knots is determined by minimizing a variant of AIC. A numerical example is used to illustrate the performance of the tensor spline estimates.

  • PDF

Neutron and gamma-ray energy reconstruction for characterization of special nuclear material

  • Clarke, Shaun D.;Hamel, Michael C.;Di fulvio, Angela;Pozzi, Sara A.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1354-1357
    • /
    • 2017
  • Characterization of special nuclear material may be performed using energy spectroscopy of either the neutron or gamma-ray emissions from the sample. Gamma-ray spectroscopy can be performed relatively easily using high-resolution semiconductors such as high-purity germanium. Neutron spectroscopy, by contrast, is a complex inverse problem. Here, results are presented for $^{252}Cf$ and PuBe energy spectra unfolded using a single EJ309 organic scintillator; excellent agreement is observed with the reference spectra. Neutron energy spectroscopy is also possible using a two-plane detector array, whereby time-of-flight kinematics can be used. With this system, energy spectra can also be obtained as a function of position. Spatial-dependent energy spectra are presented for neutron and gamma-ray sources that are in excellent agreement with expectations.

Laser Generation of Focused Lamb Waves

  • Jhang, Kyung-Young;Kim, Hong-Joon;Kim, Hyun-Mook;Ha, Job
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.637-642
    • /
    • 2002
  • An arc-shaped line array slit has been used for the laser generation of focused Lamb waves. The spatially expanded Nd:YAG pulse laser was illuminated through the arc-shaped line array slit on the surface of a sample plate to generate the Lamb waves of the same pattern as the slit. Then the generated Lamb waves were focused at the focal point of which distance from the slit position is dependent on the curvature of slit arc. The proposed method showed better spatial resolution than the conventional linear array slit in the detection of laser machined linear defect and drill machined circular defect on aluminum plates of 2mm thickness. Using the focused waves, we could detect the linear defect and the circular defect with the improvement of spatial resolution. The method can also be combined with the scanning mechanism to get an image just like by the scanning acoustic microscope(SAM).

The comparison of relative reliability on biaxial and three point flexure strength methods of light curing composite resin

  • Seo, Deog-Gyu;Rho, Byoung-Duck
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.575-575
    • /
    • 2003
  • The majority of studies comparing the mechanical properties of brittle dental restorative materials now include use of the Weibull Modulus (m). This modulus is determined from analysis of the statistical distribution of strength measurements, which can be determined using a variety of methods, including biaxial flexure, 3pt bend and 4pt bend. In comparing materials it is usually implicitly assumed that the modulus (m) is independent of test method although it is recognised to be highly dependent on flaw distributions. However, in some cases flaw distributions can be modified by sample preparation and test method may modify stressing patterns. This study investigated the pattern of strength and m in two light setting materials.

  • PDF

Surface Structure of Blend Films of Styrene/Acrylonitrile Copolymer and Poly(methyl methacrylate)(PMMA) or Hydrolyzed PMMA

  • 이원기;K. Tanaka;A. Takahara;T. Kajiyama;하창식
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.9
    • /
    • pp.958-961
    • /
    • 1997
  • The compatibility and the surface structure of blends of poly(styrene-co-acrylonitrile) (SAN) with either poly(methyl methacrylate) (PMMA) or hydrolyzed PMMA (H-PMMA) were studied in terms of film thickness, interaction, and surface free energy difference on the basis of X-ray photoelectron spectroscopy (XPS), attenuated total reflection Fourier transform IR spectroscopy and atomic force microscopy. The XPS measurement showed that the surface enrichment of (PMMA/SAN) blends with different AN contents of SAN and with different carboxyl acid contents of PMMA was dependent on the molecular interaction, the surface free energy difference between components and the sample preparation history. It was found that the compatibility of H-PMMA and SAN was reduced with increasing carboxyl acid content of PMMA.

Application of a Membrane Desolvator to the Analysis of Organic Solvents in Inductively Coupled Plasma Atomic Emission Spectrometry

  • Lee, J. S.;Lim, H. B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.9
    • /
    • pp.1040-1044
    • /
    • 1999
  • A micro porous PTFE membrane desolvator (MMD) was built and evaluated for the on-line removal of organic solvents to facilitate the determination of trace metal contaminants in the solvents by ICP-AES. Three organic solvents, isopropyl alcohol (IPA), methanol, and dimethy sulfoxide (DMSO) were studied. The MMD reduced organic solvent concentration in the sample aerosol stream by 82% to 89%, as indicated by monitoring C(I) emission. Net signal intensity of Fe, Al, and Cu was increasing with higher organic solvent concentration, with the rate of increase being solvent dependent. The signal intensities for Mg and Pb followed the trend with the C(I) signal. Changing the sweep gas flow rate affected the optimum signal intensity. Wine samples were analyzed by the method of standard addition. The concentrations of B, Al, and Mg were determined with a relative precision of less than 2.3%.

Angular Modulation of the Giant Magnetoresistance at the Second Antiferromagnetic Maximum in Co/Cu Multilayered System

  • Kang, S.J.;Kim, K.Y.;Ye, W.T.;Lee, J.
    • Journal of Magnetics
    • /
    • v.5 no.4
    • /
    • pp.135-138
    • /
    • 2000
  • In order to study the effect of the magnetic anisotropy on the giant magnetoresistance in a Co/Cu multilayered system, the angle dependent magnetoresistance (MR) was measured. The experimental results showed that the maximum MR ratio depends on the angle between the direction of the applied field and the easy axis. The angular modulation of the MR ratio can be explained by the alignments of the two 'effective' magnetization vectors that are bound to their own easy axes. Two maxima observed in MR loops at the second antiferromagnetic maximum are discussed in relation to the magnetic anisotropy, The simulated results under the assumption of the existence of two in-plane easy axes in the sample are compared with the experiments.

  • PDF

Analysis of the Temperature Dependence of Phosphor Conversion Efficiency in White Light-Emitting Diodes

  • Ryu, Guen-Hwan;Ryu, Han-Youl
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.311-316
    • /
    • 2015
  • We investigate the temperature dependence of the phosphor conversion efficiency (PCE) of the phosphor material used in a white light-emitting diode (LED) consisting of a blue LED chip and yellow phosphor. The temperature dependence of the wall-plug efficiency (WPE) of the blue LED chip and the PCE of phosphor are separately determined by analyzing the measured spectrum of the white LED sample. As the ambient temperature increases from 20 to $80^{\circ}C$, WPE and PCE decrease by about 4.5% and 6%, respectively, which means that the contribution of the phosphor to the thermal characteristics of white LEDs can be more important than that of the blue LED chip. When PCE is decomposed into the Stokes-shift efficiency and the phosphor quantum efficiency (QE), it is found that the Stokes-shift efficiency is only weakly dependent on temperature, while the QE decreases rapidly with temperature. From 20 to $80^{\circ}C$ the phosphor QE decreases by about 7% while the Stokes-shift efficiency changes by less than 1%.

Temperature Dependence of Efficiency Droop in GaN-based Blue Light-emitting Diodes from 20 to 80℃

  • Ryu, Guen-Hwan;Seo, Dong-Joo;Ryu, Han-Youl
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.468-473
    • /
    • 2018
  • We investigate the temperature dependence of efficiency droop in InGaN/GaN multiple-quantum-well (MQW) blue light-emitting diodes (LEDs) in the temperature range from 20 to $80^{\circ}C$. When the external quantum efficiency (EQE) and the wall-plug efficiency (WPE) of the LED sample were measured as injection current and temperature varied, the droop of EQE and WPE was found to be reduced with increasing temperature. As the temperature increased from 20 to $80^{\circ}C$, the droop ratio of EQE was decreased from 16% to 14%. This reduction in efficiency droop with temperature can be interpreted by a temperature-dependent carrier distribution in the MQWs. When the carrier distribution and radiative recombination rate in MQWs were simulated and compared for different temperatures, the carrier distribution was found to become increasingly homogeneous as the temperature increased, which is believed to partly contribute to the reduction in efficiency droop with increasing temperature.

Intra Prediction Mode Dependent Reference Sample Selection Method for Cross- Component Linear Model (CCLM 에서 화면 내 예측 모드에 따른 참조 샘플 선택 방법)

  • Lee, Jongseok;Park, Seanae;Choi, Hansol;Sim, Donggyu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2018.06a
    • /
    • pp.188-189
    • /
    • 2018
  • 본 논문에서는 색차 성분의 화면내 예측 모드인 CCLM( Cross Component Linear Model) 의 계산 복잡도 감소를 위하여 휘도 성분의 화면내 예측 모드에 따라 주변 참조 샘플 쌍을 선택적으로 사용하는 방법을 제안한다. 제안하는 방법은 총 67 가지 화면내 예측 모드를 3 개의 구간으로 나누고 각 구간별로 사용하는 참조 샘플 쌍의 위치를 정하여 사용하였다. 제안하는 방법의 성능 평가를 위하여 AI( All Intra) 환경에서 JEM7.0 대비 부호화 성능을 측정하였다. 실험결과로서 제안하는 방법이 JEM7.0 대비 Y, U, V 각각 평균 0.04%, 0.61%, 0.62% 의 BD-rate 손실 및 평균 2%, 최대 8% 부호화 시간 감소를 보인다.

  • PDF