• Title/Summary/Keyword: Department of Radiological Science

Search Result 2,481, Processing Time 0.028 seconds

Comparative Evaluation of Reproducibility of Knee Joint Collateral Ligament Stress-radiogram Using Telometer (Telometer를 이용한 슬관절 측부인대 Stress-radiogram의 재현성 비교평가)

  • Jeong, Jin-Man;Jeong, Seong-Bin;Kim, Sang-Hyun;Lee, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.539-543
    • /
    • 2018
  • Telometer is a supplementary filming device that improves the image quality and minimizes the motion unsharpness by enhancing the reproducibility of diagnostic images because it applies constant pressure (force) to the affected area. The stress-radiogram which is widely used to provide the o-bjective quantitative stability of knee ligament is reported in literature as the most suitable method to evaluate the stability of ligament and it is advised to use the Telometer. In order to evaluate the image reproducibility of the Telometer, the collateral ligament which is the most vulnerable among the ligaments consisting of the knee joint, the stress-radiogram was executed in the order of the Telometer, the push pull gauge and the conventional stress radiogram. Then, SPSS (Statistical Package for the Social Science) for Windows 22.0 was used for comparison and evaluation. According to the results of comparison and evaluation, the standard errors and standard deviations became smaller in the order of the Telometer, the push pull gauge, the conventional stress radiogram while the image reproducibility was higher in the order of the Telometer, the push pull gauge, the conventional stress radiogram. Therefore, it is considered that the use of the TELOS for stress-radiogram would enhance the quality of patient diagnostic images and the work performance of radiologists.

An Analysis of Reliability by Factors for Development of Job Stress Measurement Tools of Radiological Technologists (방사선사의 직무 스트레스 측정도구 개발을 위한 요인별 신뢰도 분석)

  • Jung, Hong-Ryang;Son, Bu-Soon;Lim, Cheong-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.103-110
    • /
    • 2006
  • The present study is designed to analyze reliability and validity of the instruments used to measure job stress of radiological technologists mainly by means of the questionnaires from 'Korean edition of NIOSH check list'. The subjects of this study are 890 radiological technologists active at 44 general hospitals in 16 provinces and cities across the country. The item-total reliability revealed that 10 factors in 6 are the major causes of stress in job life of radiological technologists. The measuring instrument proved to be valid with reliability coefficient of internal consistency by factors being more than 0.7. The factors found to be applicable herewith include limit and authority of job (0.73), cohesion within departments (0.86), resources control (0.81), mental requirements (0.85), job load (0.82), and job stability (0.72). When job autonomy item of causes are modified for proper use to radiological technologists, the measuring instruments are expected to show high reliability. It seems, however, necessary to develop a measuring instrument to analyze and use the validity of related measuring instruments since the reliability here was rated low, with statistical coefficients lower than 0.7 in such factors as job management (0.57), conflicts within departments (-1.13), sense of responsibility for patients (0.66) and usage of education (0.26). As this study was intended to examine reliability and validity of the concepts related to measurement of job stress on the part of radiological technologists, it nay not be proper to apply the results of this study to general use, but is advised to utilize them as basis for developing instruments to verify reliability and validity by comparing with and analyzing other measuring instruments.

Differential Diagnosis of Thick Myocardium according to Histologic Features Revealed by Multiparametric Cardiac Magnetic Resonance Imaging

  • Min Jae Cha;Cherry Kim;Chan Ho Park;Yoo Jin Hong;Jae Min Shin;Tae Hoon Kim;Yoon Jin Cha;Chul Hwan Park
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.581-597
    • /
    • 2022
  • Left ventricular (LV) wall thickening, or LV hypertrophy (LVH), is common and occurs in diverse conditions including hypertrophic cardiomyopathy (HCM), hypertensive heart disease, aortic valve stenosis, lysosomal storage disorders, cardiac amyloidosis, mitochondrial cardiomyopathy, sarcoidosis and athlete's heart. Cardiac magnetic resonance (CMR) imaging provides various tissue contrasts and characteristics that reflect histological changes in the myocardium, such as cellular hypertrophy, cardiomyocyte disarray, interstitial fibrosis, extracellular accumulation of insoluble proteins, intracellular accumulation of fat, and intracellular vacuolar changes. Therefore, CMR imaging may be beneficial in establishing a differential diagnosis of LVH. Although various diseases share LV wall thickening as a common feature, the histologic changes that underscore each disease are distinct. This review focuses on CMR multiparametric myocardial analysis, which may provide clues for the differentiation of thickened myocardium based on the histologic features of HCM and its phenocopies.

The Role of Surgery in the Treatment of Spinal Myeloma

  • Kwon, Austin-Hyuk;Chang, Ung-Kyu;Gwak, Ho-Shin;Youn, Sang-Min;Rhee, Chang-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.187-192
    • /
    • 2005
  • Objective: Spinal myeloma has been treated with radiation therapy and chemotherapy. However, the role of surgery was not fully evaluated. This study is performed to evaluate the efficacy of surgery in the treatment of spinal myeloma. Methods: 22 patients who were treated with surgery for spinal myeloma from August 1999 to April 2003 were analyzed. Radiological finding, surgical methods and result were reviewed in retrospective study. For compression fracture due to myeloma infiltration, percutaneous vertebroplasy(PVP) was done. Decompression surgery with or without fixation was performed for patients with neurologic deficit. The modalities of surgery consist of PVP (14 cases), corpectomy and fixation (7 cases), and laminectomy and epidural mass removal (3 cases). To evaluate clinical outcome, visual analogue pain score and Frankel neurological scale were used. Results: In 14 cases of PVP, total 57 vertebral segments were treated including 21 thoracic vertebral bodies and 36 lumbar vertebral bodies. Pain relief was achieved in all cases. The pain score changed from 7.7 (preoperatively) to 2.5 (postoperatively). And pain relief effect was maintained over than one year. Frankel grade improved in decompression cases. Conclusion: Surgical treatment can alleviate pain and improve neurologic deficit immediately in spinal myeloma patients.

Evaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters: A Pilot Study (ADMIRE 반복적 재구성 파라메터에 따른 CT 영상의 특성 및 무참조 기반 화질 평가: 선행연구)

  • Bo-Min Park;Yoo-Jin Seo;Seong-Hyeon Kang;Jina Shim;Hajin Kim;Sewon Lim;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.175-182
    • /
    • 2024
  • Advanced modeled iterative reconstruction (ADMIRE) represents a repetitive reconstruction method that can adjust strength and kernel, each of which are known to affect computed tomography (CT) image quality. The aim of this study was to quantitatively analyze the noise and spatial resolution of CT images according to ADMIRE control factors. Patient images were obtained by applying ADMIRE strength 2 and 3, and kernel B40 and B59. For quantitative evaluations, the noise level, spatial resolution, and overall image quality were measured using coefficient of variation (COV), edge rise distance (ERD), and natural image quality evaluation (NIQE). The superior values for the average COV, ERD, and NIQE results were obtained for the ADMIRE reconstruction conditions of ADMIRE 2 + B40, ADMIRE 3 + B59, and ADMIRE3 + B59. NIQE, which represents the overall image quality based on no-reference, was about 6.04 when using ADMIRE 3 + B59, showing the best result among the reconstructed image acquisition conditions. The results of this study indicate that the ADMIRE strength and kernel chosen for use in ADMIRE reconstruction have a significant impact on CT image quality. This highlights the importance of adjusting to the control factors in consideration of the clinical environment.

Noise Level Evaluation According to Slice Thickness Change in Magnetic Resonance T2 Weighted Image of Multiple Sclerosis Disease (다발성 경화증 질환의 자기공명 T2 강조영상에서 단면 두께 변화에 따른 잡음 평가)

  • Hong, Inki;Park, Minji;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.327-333
    • /
    • 2021
  • Magnetic resonance imaging(MRI) uses strong magnetic field to image the cross-section of human body and has excellent image quality with no risk of radiation exposure. Because of above-mentioned advantages, MRI has been widely used in clinical fields. However, the noise generated in MRI degrades the quality of medical images and has a negative effect on quick and accurate diagnosis. In particular, examining a object with a detailed structure such as brain, image quality degradation becomes a problem for diagnosis. Therefore, in this study, we acquired T2 weighted 3D data of multiple sclerosis disease using BrainWeb simulation program, and used quantitative evaluation factors to find appropriate slice thickness among 1, 3, 5, and 7 mm. Coefficient of variation and contrast to noise ratio were calculated to evaluate the noise level, and root mean square error and peak signal to noise ratio were used to evaluate the similarity with the reference image. As a result, the noise level decreased as the slice thickness increased, while the similarity decreased after 5 mm. In conclusion, as the slice thickness increases, the noise is reduced and the image quality is improved. However, since the edge signal is lost due to overlapped signal, it is considered that selecting appropriate slice thickness is necessary.

A Comparative Quantitative Analysis of IDEAL (Iterative Decomposition of Water and Fat with Echo Asymmetry and Least Squares Estimation) and CHESS (Chemical Shift Selection Suppression) Technique in 3.0T Musculoskeletal MRI

  • Kim, Myoung-Hoon;Cho, Jae-Hwan;Shin, Seong-Gyu;Dong, Kyung-Rae;Chung, Woon-Kwan;Park, Tae-Hyun;Ahn, Jae-Ouk;Park, Cheol-Soo;Jang, Hyon-Chol;Kim, Yoon-Shin
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.145-152
    • /
    • 2012
  • Patients who underwent hip arthroplasty using the conventional fat suppression technique (CHESS) and a new technique (IDEAL) were compared quantitatively to assess the effectiveness and usefulness of the IDEAL technique. In 20 patients who underwent hip arthroplasty from March 2009 to December 2010, fat suppression T2 and T1 weighted images were obtained on a 3.0T MR scanner using the CHESS and IDEAL techniques. The level of distortion in the area of interest, the level of the development of susceptibility artifacts, and homogeneous fat suppression were analyzed from the acquired images. Quantitative analysis revealed the IDEAL technique to produce a lower level of image distortion caused by the development of susceptibility artifacts due to metal on the acquired images compared to the CHESS technique. Qualitative analysis of the anterior area revealed the IDEAL technique to generate fewer susceptibility artifacts than the CHESS technique but with homogeneous fat suppression. In the middle area, the IDEAL technique generated fewer susceptibility artifacts than the CHESS technique but with homogeneous fat suppression. In the posterior area, the IDEAL technique generated fewer susceptibility artifacts than the CHESS technique. Fat suppression was not statistically different, and the two techniques achieved homogeneous fat suppression. In conclusion, the IDEAL technique generated fewer susceptibility artifacts caused by metals and less image distortion than the CHESS technique. In addition, homogeneous fat suppression was feasible. In conclusion, the IDEAL technique generates high quality images, and can provide good information for diagnosis.

Evaluation of Image Quality by Using Various Detector Materials according to Density : Monte Carlo Simulation Study (몬테카를로 시뮬레이션 기반 밀도에 따른 다양한 검출기 물질을 적용한 획득 영상 평가)

  • LEE, Na-Num;Choi, Da-Som;Lee, Ji-Su;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.459-464
    • /
    • 2021
  • The detector performance is important role in acquiring the gamma rays from patients. Among parameters of detector performances, there is density, which relates to respond to gamma rays. Therefore, we confirm the detection efficiency according to various detector materials based on the density parameter using GATE (geant4 application for emission tomography) simulation tool. The NaI (density: 3.67 g/cm3), CZT (Cadimium Zinc Telluride) (density: 5.80 g/cm3), CdTe (Cadmium Telluride) (5.85 g/cm3), and GAGG (Gadoinium Aluminum Gallium Garnet) (density g/cm3) were used as detector materials. In addition, the point source and quadrant bar phantom, which is modeled for 0.5, 1.0, 1.5, and 2.0 mm thicknesses, were modeled to confirm the quatitative analysis using sensitivity (cps/MBq) and the full width at half maximum (FWHM, mm) at the 2.0 mm bar thickness containing visual evaluation. Based on the results, the sensitivity for NaI, CZT, CdTe, and GAGG detector materials were 0.12, 0.15, 0.16, and 0.18 cps/MBq. In addition, the FWHM for quadrant bar phantom in the 2.0 mm bar thickness is 3.72, 3.69, 3.70, and 3.73 mm for NaI, CZT, CdTe, and GAGG materials, respectively. Compared with performance of detector materials according to density, the high density can improve detection efficiency in terms of sensitivity and mean count. Among these detector materials, the GAGG material is efficient for detection of gamma rays.

The Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography

  • Park, Cheol-Soo;Cho, Jae-Hwan;Lee, Hae-Kag;Dong, Kyung-Rae;Chung, Woon-Kwan;Seok, Jong-Min;Han, Man-Seok;Lee, Sun-Yeob;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.138-144
    • /
    • 2012
  • 3-dimensional magnetic resonance cholangiopancreatography (MRCP) images reconstructed using the maximum intensity projection technique were analyzed qualitatively in patients diagnosed with pancreatobiliary diseases to determine their diagnostic utility. Single shot fast spin echo (SSFSE), fast spin echo (FSE) and 3-dimensional reconstructive images were acquired from 20 patients diagnosed histologically with pancreatobiliary diseases using a 3.0T MR scanner. According to qualitative analysis, the fast spin echo images and 3-dimensional reconstructed images of the hepatic duct, gall bladder and common bile duct had a higher signal to noise ratio (SNR) than the single shot fast spin echo images. Fast spin echo images and 3-dimensional reconstructed images did not show any differences. The contrast to noise ratio of the hepatic duct, gallbladder and common bile duct on the fast spin echo images and 3-dimensional reconstructed images was higher than that of the single shot fast spin echo images. The fast spin echo images and 3-dimensional reconstructed images showed similar quality.

Accuracy Evaluation of Regional Wall Motion Abnormality in Echocardiography and Cardiac Enzymes in the Diagnosis of Ischemic Heart Disease (허혈성심장질환 진단에서 심장초음파의 국소벽운동이상과 심장효소의 정확성 평가)

  • Kim, Hee-Young;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.321-330
    • /
    • 2022
  • Echocardiography and cardiac enzymes test are the tests to assess ischemic heart disease. The purpose of this study was to verify the accuracy by comparing and analyzing two tests for the diagnosis of ischemic heart disease. A retrospective study was conducted on 393 study subjects who underwent echocardiography and cardiac enzymes test. As a result of the study, regional wall motion abnormality (RWMA) increased as the age of the study subjects increased. As a result of ROC analysis, RWMA showed a larger area under the curve (AUC) than cardiac enzymes. RWMA showed the highest accuracy with 81.1% of all cardiac enzymes. Among cardiac enzymes, cTnI showed the highest accuracy. Thus, It was confirmed that RWMA of echocardiography is more accurate than cardiac enzyme is in diagnosing ischemic heart disease.