• 제목/요약/키워드: Denture relining materials

검색결과 22건 처리시간 0.022초

Wettability of denture relining materials under water storage over time

  • Jin, Na-Young;Lee, Ho-Rim;Lee, Hee-Su;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.1-5
    • /
    • 2009
  • STATEMENT OF PROBLEM. Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE. Purpose of this study is to compare and evaluate wettability of nine denture relining materials using contact angle measurements under air and water storage over time. MATERIAL AND METHODS. Nine denture relining materials were investigated in this study. Two heat-curing polymethyl-methacrylate(PMMA) denture base materials: Vertex RS, Lang, one self-curing polyethyl-methacrylate(PEMA) chairside reline resin: Rebase II, six silicone relining materials: Mucopren soft, Mucosoft, $Mollosil^{{R}}$ plus, Sofreliner Touch, GC $Reline^{TM}$ Ultrasoft, Silagum automix comfort were used in this experiment. Contact angles were measured using high-resolution drop shape analysis system(DSA 10-MK2, KRUESS, Germany) under three conditions(in air after setting, 1 hour water storage, and 24 hours water storage). Nine materials were classified into three groups according to material composition(Group 1: PMMA, Group 2: PEMA, Group 3: Silicone). Mean values of contact angles were compared using independent samples t-test and one-way ANOVA, followed by a Scheffe's post hoc analysis($\alpha$=0.01). RESULTS. Contact angles of materials tested after air and water storage increased in the following order: Group 1(PMMA), Group 2(PEMA), Group 3(Silicone). Heat-cured acrylic denture base resins had more wettability than silicone relining materials. Lang had the highest wettability after 24 hours of water storage. Silicone relining materials had lower wettability due to their hydrophobicity. Wettability of all denture relining materials, except Rebase II and $Mollosil^{{R}}$ plus, increased after 24 hours of water storage. CONCLUSIONS. Conventional heat-cured resin showed the highest wettability, therefore, it can be suggested that heat-cured acrylic resin is material of choice for denture relining materials.

키토산을 첨가한 개상용 레진의 세균부착에 관한 연구 (ADHERENCE OF ORAL BACTERIA ON VARIOUS DENTURE RELINING MATERIALS WITH CHITOSAN)

  • 방몽숙;김영이
    • 대한치과보철학회지
    • /
    • 제39권4호
    • /
    • pp.444-451
    • /
    • 2001
  • The purpose of this study was to evaluate the rate of adherence of bacteria on various denture relining materials and to find out the effects of chitosan, when it was added to denture relining materials. Denture relining materials such as Tokuso rebase normal $set^{(R)}$, Mild $rebaron^{(R)}$, $Kooliner^{TM}$, and New $truliner^{TM}$ were used in this study. The adherence of Streptococcus mutans was studied on the surfaces in the denture relining materials with chitosan and in those without chitosan. When chitosan was added to M17 broth and MRS broth, the viable cell count of Streptococcus mutans was reduced. The viable cell count of Streptococcus mutans on the specimens decreased in the following order : Mild rebaron, Tokuso rebase normal set, and Newtruliner and Kooliner. The deture relining materials with chitosan showed a lower rate of adherence of Streptococcus mutans than those without chitosan.

  • PDF

의치상 첨상재의 종류와 임상적 고려사항 (Clinical considerations for complete denture relining)

  • 조영은
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.39-45
    • /
    • 2024
  • 의치상 하방의 잔존 치조제는 시간이 지남에 따라 생리적인 흡수가 일어난다. 이로 인하여 기존의 의치는 잔존 치조제와의 적합성이 떨어지게 되며, 임상적으로 교합평면의 변화, 수직고경의 감소, 의치의 유지력과 안정성의 소실로 인한 구강기능의 상실 및 심미적인 손상이 나타난다. 따라서 의치상과 잔존 치조제 사이의 첨상은 의치의 유지관리면에서 필수적이며 잔존 치조제와 의치상의 정확한 적합은 의치 치료의 성공을 결정하는 중요한 요인이 된다. 통상적인 첨상의 방법으로는 진료실에서 시행하는 직접법과 기공실에서 시행하는 간접법이 있다. 직접법은 진료실에서 시행하기 때문에 간편하고 쉽게 시행할 수 있는 장점이 있으나, 의치상 레진과 첨상재의 결합강도에 따라 영향을 받을 수 있는 단점이 존재한다. 반면, 간접법은 기공실에서 시행하며 첨상재와 의치상 레진간의 결합력을 제공한다는 장점이 있으나, 기공실 작업 기간 동안에 환자가 의치를 사용할 수 없다는 단점이 있다. 본 연구에서는 CAD-CAM의치를 포함하여 첨상에 사용하는 재료들과 각각의 특징들을 살펴보고, 첨상시 임상적으로 고려해야 하는 사항에 대해 알아보고자 한다.

3D-프린팅 의치상 레진과 열중합 의치상 레진에서의 의치 첨상 재료 간의 전단결합강도 비교 연구 (A comparison study on shear bond strength of 3D printed resin and conventional heat-cured denture base resin to denture relining materials)

  • 조성윤;송영균
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.232-243
    • /
    • 2021
  • 목적: 다양한 3D 프린팅 의치상 레진과 여러 가지 의치 첨상 재료 간의 전단결합강도를 평가하여 기존의 열중합 의치상 레진과의 전단결합강도를 비교 평가하고자 하였다. 연구 재료 및 방법: 열중합레진(Vertex RS)과 3D프린팅 의치상 레진 두종(DENTCA Denture base II, NextDentTM Base)을 사용하였다. 의치 첨상 재료로는 성분이 다른 총 4종(Tokuyama Rebase II fast, Kooliner, Denture Liner, Denture Liner, Lang Jet Denture Repair Kit)을 사용하여 12개의 군으로 분류하였다. ISO/TS 11405규격에 따라 접착을 시행하였다. 전단결합강도를 측정하였고, 이후 입체현미경과 주사전자현미경을 이용하여 접착 계면을 관찰하고 파절편의 분석을 통하여 파절 양상을 조사하였다. 결과: 3D 프린팅 의치상 레진 군에서 의치 첨상 재료와의 전단결합강도가 열중합레진 군에 비해 유의하게 낮은 전단결합강도 결과를 나타내었다(P < 0.05). Polymethyl methacrylate계열의 첨상재료의 경우, 의치상종류와 관계없이 높은 전단결합강도를 보였다. 파절 양상은 대부분의 군에서 접착성 파절이 나타났고 일부 군에서 응집성 파절과 혼합성 파절 양상이 나타났다. 결론: Polymethyl methacrylate를 주성분으로 하는 의치 첨상 재료가 실험에 사용된 모든 의치상 레진에서 다른 의치 첨상 재료와 비교하여 높은 전단 결합강도 값을 나타내었지만, 직접법으로 의치 첨상을 시행할 경우 단량체로 Isobutyl methacrylate 성분의 의치 첨상재료를 사용하는 것이 전단결합강도면에서 유리할 것으로 사료된다.

의치상 이장재 표면의 캔디다 균주에 대한 항균제의 억제 효과 (INHIBITORY EFFECT OF ANTIFUNGAL AGENTS INCORPORATED IN DENTURE LINING MATERIALS AGAINST CANDIDA ALBICANS)

  • 장경수
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.293-300
    • /
    • 1999
  • The purpose of this study was to evaluate the in vitro antifungal effect of several kinds of denture lining materials containing nystatin and silver-zeolite on Candida albicans. Three commercially available tissue conditioners (Soft-Liner, Coe-Comfort, Coe-Soft) and two direct denture relining materials (Tokuso Rebase, Durabase) were selected. In terms of the zone of inhibition and some basic physical properties, I could find the following results ; 1. Nystatin or silver-zeolite included in those relining materials had definite antifungal activities against the Candida albicans. 2. As times went on, both of the antifungal agents's activities decreased gradually. 3. Antifungal agents did not affect the relining materials' basic physical properties. 4 Direct chairside relining materials showed unfavorable dark discoloration with response to silver-zeolite.

  • PDF

Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

  • Nirale, Rutuja Madhukarrao;Thombre, Ram;Kubasad, Girish
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.24-29
    • /
    • 2012
  • PURPOSE. To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. MATERIALS AND METHODS. A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n =20). Data were analyzed using student paired 't'and unpaired 't'test. RESULTS. Microwave disinfection produces significant shrinkage in both denture bases without relining (t =17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). CONCLUSION. Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability.

Effects of relining materials on the flexural strength of relined thermoplastic denture base resins

  • Sun, Yunhan;Song, So-Yeon;Lee, Ki-Sun;Park, Jin-Hong;Ryu, Jae-Jun;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.361-366
    • /
    • 2018
  • PURPOSE. The aim of this study was to evaluate the effects of relining materials on the flexural strength of relined thermoplastic denture base resins (TDBRs). MATERIALS AND METHODS. For shear bond strength testing, 120 specimens were fabricated using four TDBRs (EstheShot-Bright, Acrytone, Valplast, Weldenz) that were bonded with three autopolymerizing denture relining resins (ADRRs: Vertex Self-Curing, Tokuyama Rebase, Ufi Gel Hard) with a bond area of 6.0 mm in diameter and were assigned to each group (n=10). For flexural strength testing, 120 specimens measuring $64.0{\times}10.0{\times}3.3mm$ (ISO-1567:1999) were fabricated using four TDBRs and three ADRRs and were assigned to each group (n=10). The thickness of the specimens measured 2.0 mm of TDBR and 1.3 mm of ADRR. Forty specimens using four TDBRs and 30 specimens using ADRRs served as the control. All specimens were tested on a universal testing machine. For statistical analysis, Analysis of variance (ANOVA) with Tukey's test as post hoc and Spearman's correlation coefficient analysis (P=.05) were performed. RESULTS. Acry-Tone showed the highest shear bond strength, while Weldenz demonstrated the lowest bond strength between TDBR and ADRRs compared to other groups. EstheShot-Bright exhibited the highest flexural strength, while Weldenz showed the lowest flexural strength. Relined EstheShot-Bright demonstrated the highest flexural strength and relined Weldenz exhibited the lowest flexural strength (P<.05). Flexural strength of TDBRs (P=.001) and shear bond strength (P=.013) exhibited a positive correlation with the flexural strength of relined TDBRs. CONCLUSION. The flexural strength of relined TDBRs was affected by the flexural strength of the original denture base resins and bond strength between denture base resins and relining materials.

결합면 형태가 이장용 레진의 결합강도에 미치는 영향 (EFFECT OF SURFACE DESIGN ON BOND STRENGTH OF RELINING DENTURE RESIN)

  • 박은주;진태호
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.167-174
    • /
    • 2004
  • Statement of problem: Removable partial denture and complete denture often require denture base relines to improve the fit against the tissue-bearing mucosa because of gradual changes in edentulous ridge contours and resorption of underlying bone structure. Purpose: This study was performed to investigate the effect of surface design on bond strength of relining denture base resins to denture base acrylic resin. Materials and method: Heat curing resin(Lucitone 199, Dentsply U.S.A. and Vertex, Dentimex, Holland), self curing resin(Tokuso rebase, Tokuyama, Japan), and visible light curing resin(Triad, Dentsply, U.S.A.) were used in this study. The surface designs were classified as butt, bevel and rabbet joint and the bond strengths were measured by Universial Testing Machine (Zwick 2020, Zwick Co., Germany). Results and Conclusion: The obtained results from this study were as follows ; 1. The bond strength of Vertex resin was higher than those of Tokuso rebase and Triad. 2. The bond strength of rabbet and bevel joint was higher than that of butt joint. 3. The failure mode of Triad and Tokuso rebase was mainly adhesive, but cohesive failure was shown mainly in vertex.

Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base

  • Park, Se-Jick;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.262-272
    • /
    • 2022
  • PURPOSE. This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment. MATERIALS AND METHODS. Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey's honest significant difference test was used for post-hoc analysis (P < .05). RESULTS. Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS. CONCLUSION. The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.

타이타니움 의치상에 대한 다양한 금속표면처리제의 적용이 첨상레진과의 결합강도에 미치는 영향 (The Effects of Various Metal Surface Treatments on the Shear Bond Strength between Titanium Denture Base and Relined Resins)

  • 은준영;조인호;이종혁
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to evaluate the effect of various metal surface treatments on the shear bond strength between titanium denture base and relined resins. The surfaces of commercially pure(cp) titanium were sandblasted with $50{\mu}m$ $Al_2O_3$ for 20 seconds and each group was treated with MR $Bond^{(R)}$, Alloy $Primer^{(R)}$, and Super-Bond $C&B^{(R)}$ accordingly. The specimens were completed by application of relining resins. The specimens were stored in room temperature. And the shear bond strength of the specimens were measured with the MTS universal testing $machine^{(R)}$. The results were as follows: 1. In comparison with the relining materials, $Kooliner^{(R)}$ groups showed statistically higher shear bond strength than Tokuyama Rebase $II^{(R)}$ groups(p<0.05). 2. Comparing shear bond strength, according to surface treatment, Super-bond $C&B^{(R)}$ groups showed the highest bond strength and were significantly higher than the other three groups(p<0.05). Alloy $Primer^{(R)}$ groups showed no significant difference with the MR $Bond^{(R)}$ groups, but was significantly higher than the sandblasting-only groups(p<0.05). 3. Comparing surface treatment in each groups, for two types of relining resin, the group which applies $Kooliner^{(R)}$ and Super-bond $C&B^{(R)}$ showed the highest bond strength and showed significant difference compared to the other groups(p<0.05). When using Tokuyama Rebase $II^{(R)}$, Super-bond C&B group showed the highest bond strength, but there were no significant difference compared to the Alloy $Primer^{(R)}$ group. In this limited study, applying $Kooliner^{(R)}$ and Super-Bond $C&B^{(R)}$ after sandblasting is considered to be advantageous for relining of titanium base dentures.