• Title/Summary/Keyword: Dentin-bonding agents

Search Result 83, Processing Time 0.026 seconds

THE EFFECT OF VARIOUS DESENSITIZING AGENTS ON RETENTION AND FITNESS OF CEMENTED CROWNS WITH ZINC PHOSPHATE CEMENT (수 종의 지각 과민 완화제가 인산 아연 시멘트 사용시 주조관의 유지력 및 적합도에 미치는 영향)

  • Oh Se-Wook;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.181-194
    • /
    • 1994
  • The purpose of this study was to compare the retention and fitness of crown treated with various desensitizing agents on natural teeth. Varnish, dentin primer, bonding agent and potassium oxalate treated groups and control group with no treatment were used. The retention test was executed with the Instron test machine(Instron Co.,U.S.A.) on 24 hours after cementation with zinc phosphate cement. After retention test, the teeth and crowns were washed and recemented. The cemented crowns were embedded in clear resin and sectioned with a diamond saw. The occlusal and marginal fitnesses, were measured indirectly with a stereomicroscopic photographs. The result of this study were obtained as follows : 1. The retention of control group was higher than any other desensitizing agent treated group. 2. The differences of retention among varnish, dentin primer, bonding agent and potassium oxalate treated groups were not statistically significant. 3. There were no statistically significant difference in fitness at occlusal surface and margin among control, varnish, dentin primer, bonding agent and potassium oxalate treated groups. According to these results, desensitizing agents used to protect the pulp from irritation of luting agents may adversely affect the retention of castings. Therefore, desensitizing agents should be used in limited areas carefully.

  • PDF

The Study of the Effect of Thermocycling on Microleakage within Various Dentin Bonding Agents (열순환이 상아질접착제 처리 후 미세누출에 미치는 영향에 관한 연구)

  • Yoo, Seung-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.147-155
    • /
    • 2008
  • Three groups of dentin bonding agents (5th generation Single Bond 2.0 and two 6the generation Prompt L-Pop, AdheSE) applied to class V cavities (upper portion with enamel margin and lower portion with dentin margin) prepared at buccal and lingual portion of premolars and molars. Each groups consist of 30 teeth. Devide into two groups, one without thermocycling and the other thermocycled. After then, infiltrate methylene blue into the gap between restoration and tooth. Within non-thermocycled groups, Single Bond 2.0 group shows lesser leakage at enamel margin than other two bonding agents (p <.05) but shows more leakage at dentin margin than other two bonding agents. (p <.05) Within thermocycled groups, Single Bond 2.0 group shows lesser leakage at both enamel and dentin margins. (p <.05)

AN EXPERIMENTAL STUDY FOR SHEAR BOND STRENGTH OF COMPOISTE RESIN USING SEVERAL DENTIN BONDING AGENTS AND LIGHT CURED GLASS IONOMER CEMENT (상아질 접착제를 사용한 광중합 복합레진과 Glass Ionomer Cement의 전단 결합력에 관한 연구)

  • Kwon, Byung-Ryul;Lee, Jae-Ho;Choi, Hyung-Jun;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.450-460
    • /
    • 1996
  • The purpose of this study was to compare shear bond strength of composite resin using several dentin bonding agents and light cured glass ionomer cement(Fuji II LC). 40 Bovine primary anterior teeth were used for this experiment. Labial surface of teeth were flattened. It were divided into four groups. Each group was composed of 10 teeth. The material used for this experiment were Scotchbond Multipurpose-Z-100, Allbond 2-Aelitefil, Gluma-Pekalux, light cured glass ionomer cement(Fuji II LC). Each of the materials was applied to the exposed surfaces of 10 teeth by insertion into a cylindrical shaped matrix which is 3mm diameter and 3mm in height. The completed specimens were stored at $37^{\circ}C$ under 100% humidity for 24 hours : the shear bond strength of each material to dentin surface were measured with INSTRON universal testing machine. The results were as follows : 1. Shear bond strength to dentin surface increased in order of light cured glass ionomer cement(Fuji II LC), Gluma, Allbond 2, Scotchbond Multipurpose. 2. Between shear bond strength of light cured glass ionomer cement(Fuji II LC) and Allbond 2, there was statistical significace(p<0.05) 3. Between shear bond strength of light cured glass ionomer cement(Fuji II LC) and Scotchbond Multipurpose, between shear bond strength of Gluma and Scotchbond Multipurpose, there was statistical significance.(p<0.01) The shear bond strength of dentin bonding agents were higher than light cured glass ionomer cement. The reason is that materials and quality of dentin bonding agent were enhanced. Further investigation is necessary to improve shear bond strength of light cured glass ionomer cement.

  • PDF

Dentin shear bond strength and degree of conversion of the dentin bonding agents irradiated with light emitting diode

  • Kim, Sun-Young;Um, Chung-Moon
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.576-577
    • /
    • 2003
  • I. Objectives This study investigated the dentin shear bond strength and the degree of conversion (DC) of currently used dentin bonding agents (DBAs) that were irradiated with a light emitting diode (LED) light curing unit (LCU) and a halogen LCU. II. Materials and methods The halogen LCU and the LED LCU used in this study were a VIP(Bisco, Schaumburg, IL, USA) and an Elipar Freelight(3M ESPE, St Paul, MN, USA) respectively. For the VIP, $400mW{\cdot}cm-2$ intensity mode was used to adjust to the intensity of the LED LCU. The DBAs used in this study were Scotchbond Multipurpose (3M ESPE), Single Bond (3M ESPE), One-step(Bisco), Clearfil SE Bond(Kuraray), and Adper Prompt(3M ESPE).(omitted)

  • PDF

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

MICROLEAKAGE EVALUATION IN AMALGAM RESTORATIONS USED WITH BONDING AGENTS (수종의 접착제를 사용한 아말감 수복시의 미세 변연 누출에 관한 연구)

  • Choi, Sang-Cheol;Park, Joon-Il;Kwom, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.447-463
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of copal varnish and five bonding agents(Scotchbond Multi-Purpose Plus Dental Adhesive System, Panavia 21, All Bond 2, Superbond D-Liner II plus, Fuji Duet) in reducing microleakage under amalgam restorations. Class V cavity were prepared on both buccal and lingual surface of sixty extracted human molars with cementum margin and were filled with different kinds of liners and amalgam. All teeth were stored at $37^{\circ}C$ in physiologic saline solution. After 1 week they were thermally stressed for 500 cycles between 5 and $55^{\circ}C$ in baths containing 0.5 % basic fuchsin dye. The dye penetrations were observed with a stereomicroscope. Scanning electron micrographs were taken of representative tooth sections from each group to assess the nature of the tooth/liner/amalgam interface. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The results were as follows ; 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. At the dentin and enamel margins, the leakage value of Copalite-lined group showed significantly higher than that of no liner group (p<0.05), but showed significantly lower than that of bonding agent lined-groups (p<0.05). 3. There was no significant difference between the bonding agent lined-groups (p>0.05). 4. On the backscattered scanning electron microscopy observation, discontinuous gaps were observed between amalgam and dentin in the bonding agent-lined amalgam restorations and the bonding agents appeared to fill the gap space and were mixed with amalgam particles. At the amalgam/tooth interface, unsealed dentin and continuous gaps were found in both unlined and Copalite-lined restorations.

  • PDF

The effects of desensitizing agents, bonding resin and tooth brushing on dentin permeability, in vitro (지각과민 처치제 후 접착레진 처리가 상아질 투과도에 미치는 영향)

  • Hong, Seung-Woo;Park, No-Je;Park, Young-Bum;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.165-176
    • /
    • 2014
  • Purpose: The effects of desensitizing agent are often for a short duration. One of the reasons is believed to be wear of desensitizing agent by tooth brushing. To reduce the wear and make the duration longer, dental bonding resin was applied and the changes of dentin permeability after toothbrushing were measured. Materials and methods: Extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1 mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance and scanning electron microscope images (SEM) were compared and contrasted before and immediately after the application of desensitizing agent and bonding resin and then after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study; they were All-Bond 2, Seal & Protect, Gluma, and MS Coat. And Dentin/Enamel Bonding resin (Bisco Inc.) was used. The results of this study are as follows. Results: On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent and bonding resin. Compared with the specimens treated only with desensitizer, the specimens treated with All-Bond 2, Gluma, MS Coat and plus D/E bonding resin had a little increase in hydraulic conductance after 1, 2 and 6-week tooth brushing. In case of Seal & Protect, the specimens showed the same result only after 6-week tooth brushing. On examination of SEM, the dentinal tubule diameter had decreased after treatment of desensitizing agents and bonding resin. And the specimens treated with All-Bond2, Seal&Protect, Gluma, MS Coat and plus D/E bonding resin had an significant decrease in diameter of dentinal tubule after 6-week tooth brushing. Conclusion: According to the results of this study, it is effective to use bonding resin after application of desensitizer in reducing the wear by tooth brushing and making the duration longer. In this study, just 6-week tooth brushing was performed, and it is not enough to regard it as a long-term data. So further study is needed and more perfect method for treating dentin hypersensitivity should be developed.

THE CYTOTOXIC EFFECTS OF BONDING AGENTS ON THE HUMAN PULP FIBROBLASTS (Bonding agent의 치수 섬유아세포에 대한 독성 연구)

  • Park, Sun-Hee;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.99-117
    • /
    • 1991
  • The purpose of this study is to evaluate the effects of dentin bonding agents on the fibroblasts cultivated from human pulp tissue. The fibroblasts were cultured in DMEM/10%FBS medium. Whatman filter paper discs (6mm diameter) soaked with $2{\mu}l$ of dentin bonding agents were placed on a millipore filter (pore size $0.22{\mu}m$) contained in a 50mm Petri dish, and then, exposed for 10 minutes, 30 minutes, 1 hour, 6 hours, 12 hours, 24 hours, 4 days and 7 days in $37.^{\circ}C$, 5% $CO_2$ incubator. The results of the experiments were analyzed by counting the cells and measuring the protein contents at 1 day, 4 days and 7 days. The results of this study were as follows: l. CLEARFIL NEW BOND, LITE-FIL BOND, GLUMA 3 Primer and GLUMA 4 Sealer showed cytotoxicity compared to the control group in the cell counts and the protein contents. 2. GLUMA 4 Sealer showed the least cytotoxicity among the three dentin bonding agents. 3. The results of the cell count were simialr to the results of protein content measurement. 4. LITE-FIL BOND exhibited marked cytotoxicity during 1 day, but, the cytotoxicity was slightly reduced after 4 and 7 days. 5. In GLUMA 3 Primer group, it was not possible to count the cell numbers and measure the protein contents, but the degeneration of cells was observed under the inverted phase-contrast microscope.

  • PDF

An Evaluation of Shear Bond Strength of New Dentin Bonding Agents (최근 소개된 상아질 접착제의 전단 접착 강도 비교)

  • Shin, Jisun;Hwang, Eunji;Kim, Jongbin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.358-364
    • /
    • 2017
  • For the purpose of convenience and reducing time, newer bonding agents have been developed for composite resin restoration. Recently developed one bottle bonding system including etching, primer and adhesive can make procedures simpler and less technique-sensitive than old generation adhesives. The aim of this study was comparing the shear bond strength of new dentin bonding agents to the 5th generation bonding agent which had an etching step. 78 premolar teeth were randomly divided into three groups which were treated with $Tetric^{(R)}$ N-Bond Universal (Ivoclar Vivadent, Liechtenstein), $GC^{(R)}$ G-Premio BOND (GC Co., Japan) without additional etching step and $3M^{TM}$ Single Bond2 (3M ESPE, USA) with an etching step following manufacturer's instructions. $Filtek^{TM}$ Z-350 (3M ESPE, USA) composite resin was applied and light cured over bonding agents. For shear bond strength evaluation, universal testing machine was used with a wedge technique. As a result, shear bond strength of one step bonding agents was lower than two step bonding agent and there were statistically significant differences between them (p < 0.05). In addition, within the result of two new bonding agents, $Tetric^{(R)}$ N-Bond Universal showed significantly higher shear bond strength than $GC^{(R)}$ G-Premio BOND (p < 0.05).