• 제목/요약/키워드: Dentin bonding system

검색결과 94건 처리시간 0.02초

상아질과 접착제 간의 계면양상 (INTERFACIAL MORPHOLOGY BETWEEN DENTIN AND ADHESIVES)

  • 강지영;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.183-192
    • /
    • 1995
  • The purpose of this study was to evaluate the effect of smear layer management on the interfacial morphology between dentin bonding system and dentin. Clearfil New Bond, Scotchbond Multipurpose, Prisma Universal Bond 3 and X-R Bond were used on the cervical dentinal surfaces of bovine incisor teeth. All of the dentin bonding systems were labeled with fluorescene in primer and rhodamine B in adhesive. Specimens of 2~3mm thichness were prepared by longitudinal and labiolingual sectioning. The interface between dentin bonding system and dentin was observed by flouresence imaging with a confocal laser scanning microscope. Following results were obtained. 1. In the specimen of Clearfil New Bond, dentinal tubules were widened by destruction of peritubular dentin in the course of treatment with phosphoric acid of high concentration. 2. Hybrid layer was observed in the specimen of Scotchbond Multipurpose and X-R Bond. 3. In the specimen of Prisma Universal Bond 3, the penetraton of adhesive was not observed clearly.

  • PDF

ONE-STEP 접착제의 상아질 접착에 관한 연구 (A STUDY ON THE DENTIN BONDING OF ONE-STEP BONDING AGENT)

  • 조영곤;박성택;박광수
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.468-476
    • /
    • 1998
  • The purpose of this study was to observe the morphologic change of dentinal surface, adhesion in interface between dentin and bonding agents, and penetration pattern of resin tags into dentinal tubles according to bonding procedure of ONE-STEP universal adhesive system. Ten extracted human molars were mounted in dental stone and sectioned to expose mid-coronal occlusal dentin and again sectioned tooth crown apically. Specimens were randomly assigned to three groups for dentin conditioning with 32% phoshoric acid, two coats of bonding agents after dentin conditioning, and bond of composite resin. The surfaces of dentin were treated with etch ant and applied bonding agent, and bonded composite resin according to the directions of manufacturer. Specimens which were boned composite were sectioned longitudinally for observing interfaces between resin and dentin. Two of specimens which were sectioned longitudinally were immersed in 6 N HCL for 30 seconds and 1% NaOCL for 12 hours to partially demineralize and deproteinize the dentin substrate. Each specimen was mounted on a brass stub, sputter-coated with gold and observed under SEM. The result were as follows : 1. On the dentinal surface which was conditioned with 32% phosphoric acid. the smear layer was completely removed. orifices of dentinal tubules were opened 3-$5{\mu}m$ wide. and dentinal surface was irregular. 2. On the dentinal surface which was applied ONE-STEP. bonding agent. resin particles were observed on the orifices of dentinal tubules and intertubular dentin. 3. There were close adaptation between dentin and resin and were the pattern which composite invaded into dentin. 4. 1-$3{\mu}m$-wide hybrid layer was visible in the interface between dentin and resin. 5. Long and funnel shaped resin tags were observed in demineralized specimens. and the surfaces of tags were rough.

  • PDF

상아질 접착제의 상아세관 밀봉지속효과에 관한 연구 (A STUDY OF THE DURABILITY OF DENTINAL TUBULE SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 김의성;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.180-193
    • /
    • 1994
  • The purpose of this study was to observe the sealing ability and durability of All-Bond 2, Gluma Bonding System, Scotch bond 2 and Superbond D-liner which are dentin bonding agents used as desensitizing agents. The durability of the sealing ability of the materials were compared after 0, 140, 420, 840 tooth brushing strokes. 120 extracted teeth were divided into 5 groups and the agents were applied to the exposed dentin. No agents was applied on group I, the control group. Each specimen went through thermocycling from $5^{\circ}$ to $55^{\circ}C$, 200 times. Each group was devide into 4 subgroups and artificial tooth brushing strokes were done for 0, 140, 420, 840 times. Finally the specimens were stored in 0.5 % methylene blue solution for 24 hours in a incubator set at $37^{\circ}C$. The tooth were sectioned perpendicular to the long axis and the dye penetration ratio to the pulp was measured. The following results were obtained. 1. All four dentin bonding agents initially showed excellent sealing ability. 2. All-bond 2, Gluma Bonding System and Superbond D-liner showed durability of dentinal tubule sealing effect after 840 strokes(6-week) artificial tooth brushing. 3. Scotchbond 2 showed a significant decrease in sealing ability after 420 strokes(3-week) artificial tooth brushing. (P<0.05).

  • PDF

산부식후 상아질 표면의 습윤 또는 건조가 상아질 결합에 미치는 영향 (EFFECTS OF DENTIN SURFACE WETNESS OR DESICCATION AFTER ACID ETCHING ON DENTIN BONDING)

  • 양원경;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.243-253
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate dentin bonding by two different dentin bonding systems(DBS) using acetone based primer or adhesive [All Bond 2(AB2), One Step(OS)] when they were applied by wet or dry bonding technique. Morphology of resin-dentin interface and hybrid layer thickness(HLT) were investigated using Confocal Laser Scanning Microscope(CLSM) and compared to shear bond strength(SBS). 72 extracted sound human molars were randomly divided into 4 groups of 18 teeth each - Group 1.(AW); AB2 by wet bonding. Group 2(AD); AB2 by dry bonding. Group 3.(OW); OS by wet bonding, Group 4.(OD); OS by dry bonding. In 6 teeth of each group, notch-shaped class V cavities(depth 2mm) were prepared on buccal and lingual surface at the cementoenamel juction(12 cavities per group). To obtain color contrast in CLSM observation, bonding resins of each DBS were mixed with rhodamine B and primer of AB2 was mixed with sodium fluorescein. Prepared teeth of each group were treated with AB2, OS, respectively according to the manufacturer's instructions except for dentin surface moisture treatment after acid etching. In group 1 and 3, after acid etching, excess water was removed with wet tissue(Kimwipes), leaving consistently shiny, visibly hydrated dentin surface. In group 2 and 4, dentin surface was dried for 10 seconds at 1 inch distance. The treated teeth were then packed with composite resin(${\AE}$litefil) and light-cured. 12 microscopic samples($60{\sim}80{\mu}m$ thickness) of each group were obtained after longitudinal section and grinding(Exakt cutting and grinding system). Morphological investigation of resin-dentin interface and HLT measurement using CLSM were done. For measurement of SBS, remaining 12 teeth of each group were flattened occlusally to remove all enamel and grinded to 500 grit SiC(Pedemet Specimen Preparation Equipment). After applying DBS on the exposed dentin surface, composite resin was applied in the shape of cylinder, which has 5mm diameter, 1.5mm thickness, and light cured. SBS was measured using Instron with a crosshead speed of 0.5mm/min. It was concluded as follows, 1. HLT of AW(mean: $2.59{\mu}m$) was thicker than any other group, and followed by AD, OW, OD in descending order(mean; 2.37, 2.28, $1.92{\mu}m$). Only OD had statistically significant differences(p<0.05) to AW and AD. 2. There were intimate contact of resin and dentin at the interface in wet bonding groups, but gaps or irregular interfaces were observed in dry bonding groups. 3. The length, diameter, density of resin tags were various even in the same group without significant differences between groups and lots of adhesive lateral branches were observed. 4. There were no statistically significant difference of SBS between AB2 and OS, but SBS of wet bonding groups were significantly higher(p<0.05) than dry bonding groups. 5. There were no consistent relationships between HLT and SBS.

  • PDF

7세대 결합제의 미세누출에 관한 연구 (MICROLEAKAGE OF 7TH GENERATION BONDING SYSTEM)

  • 이상엽;김대업;라지영;이광희
    • 대한소아치과학회지
    • /
    • 제33권3호
    • /
    • pp.422-428
    • /
    • 2006
  • 상아질 접착제는 많은 발전을 거듭하여 적용 단계가 단순화되고 짧아져서 어린이에게 사용하기에 더욱 편리해졌다. 본 연구에서는 최근 개발된 7세대 결합제인 $i-bond^{TM}$(Kulzer, Germany)의 미세누출을 기존에 사용되는 다른 결합제와 비교하여 그 효용성을 평가하기 위함이다. 40개의 교정적 목적으로 발거된 건전한 소구치의 협면과 설면에 5급 와동을 형성하고 무작위로 4개의 군으로 나누었다. 1군은 4세대인 Scotchbond $Multi-Purpose^{(R)}$(3M, USA), 2군은 5세대 Clearfil SE Bond(Kuraray, Japan), 3군은 6세대 AQ Bond(Sun medical, Japan), 4군은 7세대 $i-bond^{TM}$(Kulzer, Germany)를 적용하고 복합레진 Z100(3M, USA)으로 충전하였다. 시편을 $5^{\circ}C$$55^{\circ}C$에 각 30초간 계류시켜 1,000회 열순환하고 2% methylene blue 용액에 24시간 넣어 염료를 침투시킨 뒤, 저속 diamond cutter($Isomet^{TM}$, Buehler, USA)를 이용하여 주수하에 치아를 협설로 절단하였다. 색소의 침투 정도를 입체현미경을 이용하여 침투깊이를 0에서 3점으로 채점하여 측정한 뒤 미세누출 정도를 비교하였다. 결과적으로 7세대 결합제의 미세누출 평균값이 다른 결합제보다 높게 나왔으며, 특히 4세대 결합제와는 통계적으로 유의한 차이가 있었다.

  • PDF

Self-etching priming/bonding agent를 이용한 수복에서 microleakage에 관한 연구 (THE STUDY ON THE MICROLEAKAGE OF THE RESTORATION WITH SELF-ETCHING PRIMING/BONDING AGENT)

  • 유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제31권1호
    • /
    • pp.26-33
    • /
    • 2004
  • Bonding Agent는 1세대에서 5세대에 거치기까지 많은 발전을 하였고, 최근에는 임상술식과정의 단축에 있어 비약적인 발전을 보였다. 최근에 개발되어 소개된 self-etching priming/bonding agent는 6세대 bonding agent로 분류되며, 이를 이용하여 법랑질 및 상아질에 대한복합 레진의 충전시 발생하는 미세누출을 methylene blue를 이용하여 관찰한 결과, 상아질에서는 기존의 4세대 5세대 접착제와 유의 한 차이가 없었으나, 법랑질에서는 6세대 bonding agent가 통계학적으로 높은 미세누출 양상을 보였다.

  • PDF

상아질 결합제의 L929 세포 독성에 관한 연구 (CYTOTOXICITY OF DENTIN BONDING SYSTEM ON L929 CELLS)

  • 임미경;지정호;김상섭
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.209-219
    • /
    • 1997
  • The research of the dentin bonding system was mainly on the chemistry and bonding strength. And in vitro assessement of biocompatibility of dentin bonding system was not completely developed. The purpose of this study was to evaluate the cytotoxic effect of several dentin primers. Scotchbond Multi-Purpose (3M Dental Products. USA). Gluma (BayerDental. Germany). All-Bond (Bisco. USA). ProBond (CaulkDensply, USA) and VeridonFil (Dongyang Nylon. Korea) were included. Cytotoxicity was tested using MTT cell viability test. 0.5 ul. 1 ul. 2 ul and 10 ul of each primer were added to the 96 well plate of incubated L929 cell lines. After 30-minute. 1. 4. 24 and 72-hour exposures. absorbance of L929 cells was observed with ELISA reader. All data were analyzed using t-test. All primers showed cytotoxicity on L929 cells under every conditions used in this study. Absorbance of L929 cells was decreased by time. Scotch bond group exhibited the lowest absorbance value in all exposure time and value.

  • PDF

치수압이 상아질 접착제의 미세전단 결합강도에 미치는 영향에 관한 In vitro 연구 (MICRO-SHEAR BOND STRENGTH TO DENTIN UNDER SIMULATED PULPAL PRESSURE)

  • 송윤정;박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.339-345
    • /
    • 2004
  • The aim of this study was to measure and compare the micro shear bond strengths of the following dentin bonding systems to the dentin surfaces under simulated pulpal pressure: All Bond $2^{\circledR},{\;}Second^{\circledR},{\;}AdheSE^{\circledR}$, Adper Prompt $L-Pop^{\circledR}$. The occlusal surfaces of 180 extracted human molars were prepared so the dentin bonding surfaces could be exposed. The teeth were randomly assigned to 3 equal groups of 60 each and subdivided. The dentin surfaces were treated with the above mentioned bonding system and resin composite cylinders were built up under a simulated pulpal pressure when saline (Group II) or diluted bovine serum (Group III) was used as the pulpal fluid. As a control. the same procedures were performed in the dried dentin surfaces (Group I). After one day of storage in water. the micro shear bond strengths were measured using an EZ tester. Group II and III showed significantly lower shear bond strength than Group I statistically (p < 0.05). $SEbond^{\circledR}{\;}and{\;}AdheSE^{\circledR}$ showed no difference among the different dentin condition. In the Adper Prompt $L-Pop^{\circledR}$. a simulated pulpal pressure were applied to the specimens using diluted bovine serum. which showed a higher strength than the specimens in which saline was used (p < 0.05).

상아질접착제와 열순환에 따른 유동성 레진의 전단결합강도 비교 연구 (A COMPARATIVE STUDY OF SHEAR BOND STRENGTH OF FLOWABLE RESIN ASSOCIATED WITH DENTIN ADHESIVE SYSTEMS WITH THERMOCYCLING EFFECT)

  • 남기영
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.383-393
    • /
    • 2006
  • Statement of problem : Limited research on flowable resin has been undertaken on its application directly on dentin associated with the adhesive systems. Purpose : This study was to evaluate the shear bond strengh and fracture aspect of flowable resin on human dentin with various types of dentin bonding adhesives with thermo cycling effect. Materials and methods: Filtek-Flow(3M ESPE, USA) was used as flowable resin and Eighty human molars were randomly divided into 4 groups : three dentin bonding adhesives (Scotchbond-Multipurpose : 3-step contentional system, One-Step : One-bottle system. Prompt L-Pop : All-in-one, self-etching primer) and 32% etching treatment without bonding adhesive as a control group. For evaluating their durability of bonding, each group was subdivided : storaging in the water at 37$^{\circ}C$(24 hours) and thermocycling (0$^{\circ}C$-55$^{\circ}C$, 30 seconds intervals, 1000 cycle). Shear bond strength tests were performed and resin-dentin interface and fracture mode were observed. Results were analysed by one-way ANOVA and Scheffe's multiple range test. Results and Conclusion : 1. At 0 cycle, the mean shear bond strength of One-Step exhibited the highest value of all groups(p<0.05), and there were no significant differences between Prompt L-Pop and Scotchbond-Multipurpose, Scotchbond-Multipurpose and control(p>0.05). After 1000 thermocycling, One-Step exhibited higher value than other groups(p<0.05), and there were no significant differences among other groups (p>0.05). 2. The shear bond strength of each group was significantly decreased after thermocycling except Scotchbond-Multipurpose (p>0.05). 3. The most common failure mode was adhesive type and mixed type, next in order.

AII-Bond - Fourth Generation Dentin Bonding System

  • Suh, Byoung I.
    • 대한심미치과학회지
    • /
    • 제3권1호
    • /
    • pp.23-31
    • /
    • 1995
  • The All-Bond system is a unique development in the field of adhesive dentistry. It is a universal bonding system that will bond composite to all dental-related surfaces: dentin, enamel, metal alloy (precious and nonprecious), amalgam, porcelain, and composite. It is also the only system that allows use of both the conservative and all-etch techniques. The main purpose of this paper is to explain the features of the All-Bond system. Its chemistry and a working hypothesis are shown as well.

  • PDF