• 제목/요약/키워드: Dental scanner

검색결과 272건 처리시간 0.03초

Utility of intraoral scanner imaging for dental plaque detection

  • Chihiro Yoshiga;Kazuya Doi;Hiroshi Oue;Reiko Kobatake;Maiko Kawagoe;Hanako Umehara;Kazuhiro Tsuga
    • Imaging Science in Dentistry
    • /
    • 제54권1호
    • /
    • pp.43-48
    • /
    • 2024
  • Purpose: Oral hygiene, maintained through plaque control, helps prevent periodontal disease and dental caries. This study was conducted to examine the accuracy of plaque detection with an intraoral scanner(IOS) compared to images captured with an optical camera. Materials and Methods: To examine the effect of color tone, artificial tooth resin samples were stained red, blue, and green, after which images were acquired with a digital single-lens reflex (DSLR) camera and an IOS device. Stained surface ratios were then determined and compared. Additionally, the deviation rate of the IOS relative to the DSLR camera was computed for each color. In the clinical study, following plaque staining with red disclosing solution, the staining was captured by the DSLR and IOS devices, and the stained area on each image was measured. Results: The stained surface ratios did not differ significantly between DSLR and IOS images for any color group. Additionally, the deviation rate did not vary significantly across colors. In the clinical test, the stained plaque appeared slightly lighter in color, and the delineation of the stained areas less distinct, on the IOS compared to the DSLR images. However, the stained surface ratio was significantly higher in the IOS than in the DSLR group. Conclusion: When employing IOS with dental plaque staining, the impact of color was minimal, suggesting that the traditional red stain remains suitable for plaque detection. IOS images appeared relatively blurred and enlarged relative to the true state of the teeth, due to inferior sharpness compared to camera images.

치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석 (Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system)

  • 김원수;한만소;정재관;김기백
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

디지털 치열 모형에서 악궁 관계 지표 측정의 타당성 (Validity of Arch Relationship Measurements in Digital Dental Models)

  • 류지인;양병은;이혜림
    • 대한소아치과학회지
    • /
    • 제49권1호
    • /
    • pp.14-24
    • /
    • 2022
  • 이 연구의 목적은 디지털 치열 모형에서 치아 폭경, 볼튼 비율, 수평 피개, 수직 피개를 포함한 교정적 측정의 타당성을 확인하는 것이다. 만 12 - 18세의 환자를 대상으로 세가지 형태의 치열 모형을 획득하였다. 기존의 석고 모형을 형성하였고, DOF freedom HD 모형 스캐너를 통해 디지털 모형으로 변환하였다. 그리고 CS3600 구강 스캐너로 디지털 모형을 형성하였다. 각 모형에서 측정 시행 후, 급내 상관 계수를 통해 계측의 신뢰성과 재현성을 확인하였으며, 대응 표본 t 검정을 사용하여 타당성을 평가하였다. 결과적으로 모든 군에서 급내 상관계수는 0.750을 초과하여 연구자 내 신뢰성과 연구자 간 재현성이 있음을 확인하였다. 모형 스캔한 군은 전체 및 전치 볼튼 비율, 수평 및 수직 피개에서 타당성을 보였다. 구강 스캔한 군은 전치 볼튼 비율, 수평 피개에서 타당성을 보였다. 구강 스캔한 디지털 모형을 이용한 계측은 인상 채득에 어려움이 있는 소아 청소년에게 고려할 수 있는 대안이다. 하지만 임상에서 이를 교정적 분석에 이용할 경우 오차를 고려한 적용이 필요하다.

치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향 (Effect of abutment superimposition process of dental model scanner on final virtual model)

  • 유범영;손큰바다;이규복
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.203-210
    • /
    • 2019
  • 목적: 본 연구는 치과용 모형 스캐너를 이용하여 단일 전장관과 3본 고정성의치 모형을 스캔하는 과정에서 지대치의 중첩 과정이 최종 가상 모형에 미치는 영향을 알아보려 하였다. 재료 및 방법: 평가를 위해 단일 전장관과 3본 고정성의치를 위한 석고 모형을 제작하였다. 그리고 Pindex system을 이용하여 핀 작업된 모형을 제작하였다. 기준 스캔 데이터(CAD Reference Model)와 실험 스캔 데이터(CAD Test Model)를 획득하기 위해서 치과용 모형 스캐너(E1, 3Shape A/S, Copenhagen, Denmark)를 이용했다. 기준 스캔 데이터는 지대치를 분할한 후 탈착하지 않고 스캔하였다. 그리고 실험 스캔 데이터는 분할된 지대치를 분리하여 스캔 후, 기준 스캔 데이터에 중첩되었다(n = 20). 마지막으로 3차원 검사 소프트웨어(release 2018.0.0; Geomagic control X; 3D Systems)를 이용하여 root mean square (RMS)를 분석하였고, 통계 분석은 Mann-Whitney U test를 사용하였다 (${\alpha}=.05$). 결과: 단일 전장관 지대치의 RMS 평균은 $10.93{\mu}m$, 3본 고정성의치 지대치의 RMS 평균은 $6.9{\mu}m$가 나왔다. 두 그룹의 RMS 평균값은 통계적으로 유의한 차이를 보여줬다 (P < .001). 또한 두 그룹의 양(positive)과 음(negative)의 오류는 단일 전장관 지대치는 $9.83{\mu}m$, $-6.79{\mu}m$, 3본 고정성의치 지대치는 $6.22{\mu}m$, $-3.3{\mu}m$의 평균값이 나왔다. 두 그룹의 양과 음의 오류 평균값은 통계적으로 모두 3본 고정성의치 지대치가 단일 전장관 지대치보다 통계적으로 유의하게 낮은 값을 보여주었다 (P < .001). 결론: 핀 작업된 모형의 스캔 과정에서 지대치의 개수가 증가하여도 지대치의 중첩에 의한 오류는 증가하지 않았다. 또한 단일 전장관 지대치에서 유의하게 높은 오류를 보였지만 임상적으로 허용 가능한 스캔 정확도의 범위에 있다.

치과 디지털 활용에 관한 치과위생사의 인식 (Perceptions of dental hygienists toward digital dentistry)

  • 김영선;박현숙;구인영
    • 한국치위생학회지
    • /
    • 제13권6호
    • /
    • pp.909-916
    • /
    • 2013
  • Objectives : The purpose of this study was to investigate the perceptions of dental hygienists toward digital dentistry. Methods : The subjects were 393 dental hygienists in Daegu Gyeongbuk. A total of 380 data were analyzed except the incomplete questionnaires. Data were analyzed by descriptive statistics, chi-square test, t-test, one-way ANOVA using SPSS version 18.0. Results : 1. Difference of perception by general characteristics was affected by age, academic background, working career, and married. 2. Difference of perception by utilization of digital facilities was affected by digital camera, CAD/CAM system, oral scanner, and computer system. 3. Difference of perception by digital education experience and intention of participation was affected by stronger intention to participate in digital education and practical exercise. Digital X-ray system and CAD/CAM system were the must-be equipment in education. Conclusions : Utilization of digital dentistry is the motive for education experience in dental hygienists.

구강인기법과 왁스블록의 종류에 따른 금속 코핑의 변연적합도 비교 (Comparison of marginal fit of metal copings according to wax blocks and oral scanning methods)

  • 정인성;김원영;전병욱
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.234-239
    • /
    • 2020
  • Purpose: We investigated the marginal fit between abutment and metal copings according to impression technique, wax block types, and metal types. Methods: We selected the traditional impression method of using rubber impression materials and the digital impression method of using oral scanners, three types of wax blocks, and two types of metal, both of which were domestically and commercially available, were selected to produce metal copings, and the marginal fit was determined through the use of silicon replication. Results: The measurements of axial wall fit revealed that the IYV specimens had the best fit, with a mean gap of 24.11±5.95 ㎛, followed by CEV, CHV, CSS, CSV, CES, CHS, and IYS specimens (mean: 33.44±8.41 ㎛). The differences were not statistically significant. The marginal gap measurements showed that the CEV specimen had the smallest gap, 17.25±4.13 ㎛, followed by the CSV, CHV, CSS, CES, CHS, IYV, and IYS specimen (mean: 43.47±15.63 ㎛). The differences were statistically significant. Conclusion: The axial wall fit of the metal coping (VeraBond2V; Aalba Dent, Inc., Fairfield, CA, USA) produced by the lost wax technique with the traditional impression method was excellent. The marginal fit of the metal coping (VeraBond 2V) produced by wax milling with the use of an oral scanner was also excellent. The marginal fit of the metal coping was within the clinically acceptable limits in all groups.

DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석 (Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제43권2호
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

Evaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concept

  • Hilin, Tas;Fatih, Demirci;Mesut, Tuzlali;Erkan, Bahce;Guler Yildirim, Avcu
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.379-387
    • /
    • 2022
  • PURPOSE. The aim of this study is to compare the casts obtained by using conventional techniques and liquid crystal display (LCD) three-dimensional (3D) print techniques in the All-on-4 treatment concept of the edentulous mandibular jaw. MATERIALS AND METHODS. In this study, a completely edentulous mandibular acrylic cast (typodont) with bone-level implants placed with the Allon-4 technique served as a reference cast. In this typodont, impressions were taken with the conventional technique and dental stone casts were obtained. In addition, after scanning the acrylic cast in a dental laboratory scanner and obtaining the Standard Tessellation Language (STL) data, 3D printed casts were manufactured with a 3D printing device based on the design. The stone and 3D printed casts were scanned in the laboratory scanner and STL data were obtained, and then the interimplant distances were measured using Geomagic Control X v2020 (3D Systems, Rock Hill, SC, USA) analysis software (n = 60). The obtained data were statistically evaluated with one-way analysis of variance (ANOVA) and Tukey's pairwise comparison tests. RESULTS. As a result of the one-way ANOVA test, it was determined that the stone casts, 3D printed casts, and reference cast values in all distance intervals conformed to the normal distribution and these values had a significant difference among them in all distance intervals. In Tukey pairwise comparison test, significant differences were found between casts at all distance intervals. In all analyses, the level of significance was determined as .05. CONCLUSION. 3D printed casts obtained with a 3D LCD printing device can be an alternative to stone casts when implants are placed in edentulous jaws. [J Adv Prosthodont 2022;14:379-87]

Validation of a low-cost portable 3-dimensional face scanner

  • Liu, Catherine;Artopoulos, Andreas
    • Imaging Science in Dentistry
    • /
    • 제49권1호
    • /
    • pp.35-43
    • /
    • 2019
  • Purpose: The goal of this study was to assess the accuracy and reliability of a low-cost portable scanner (Scanify) for imaging facial casts compared to a previously validated portable digital stereophotogrammetry device (Vectra H1). This in vitro study was performed using 2 facial casts obtained by recording impressions of the authors, at King's College London Academic Centre of Reconstructive Science. Materials and Methods: The casts were marked with anthropometric landmarks, then digitised using Scanify and Vectra H1. Computed tomography (CT) scans of the same casts were performed to verify the validation of Vectra H1. The 3-dimensional (3D) images acquired with each device were compared using linear measurements and 3D surface analysis software. Results: Overall, 91% of the linear Scanify measurements were within 1 mm of the corresponding reference values. The mean overall surface difference between the Scanify and Vectra images was <0.3mm. Significant differences were detected in depth measurements. Merging multiple Scanify images produced significantly greater registration error. Conclusion: Scanify is a very low-cost device that could have clinical applications for facial imaging if imaging errors could be corrected by a future software update or hardware revision.

동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로 (Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.