• 제목/요약/키워드: Dental scanner

검색결과 272건 처리시간 0.025초

구강 스캐너 임상적용 경험에 따른 치과위생사의 인식 연구: 전통적 인상채득과의 비교를 중심으로 (A study on the perception of dental hygienists according to the clinical application experience of digital intraoral scanners: focusing on the comparison with conventional impression)

  • 김명희;황영선;박항식
    • 대한치과의료관리학회지
    • /
    • 제10권1호
    • /
    • pp.84-92
    • /
    • 2022
  • Impression taking is one of the most frequently performed tasks within the legal scope of dental hygienists. This study aims to compare traditional impression and digital impression taking in various aspects with dental hygienists who have experience using digital intraoral scanners. A total of 61 subjects were included in this analysis. Traditional and digital impression taking were compared, and the perception of intraoral scanners was classified into four factors through exploratory factor analysis. After a normality test of the main variables was performed, a non-parametric test was performed. In terms of the adequacy of the size of the tool inserted into the oral cavity, traditional impression taking was more positive, and there was no significant difference in the precision of impression taking, fit of the prosthesis, and time efficiency. In contrast, the digital intraoral scanner was positive in terms of reducing nausea. In the comparison between the items of the digital intraoral scanner, relatively low satisfaction was shown in terms of convenience of use. This study compared traditional impression taking based on the experience of dental hygienists using oral scanners. It is hoped that this will be one step closer to universalization. In addition, appropriate training on how to use them should be provided.

딥러닝을 이용한 구강 스캐너 이미지 내 치아 영역 실시간 검출 (Real-time Tooth Region Detection in Intraoral Scanner Images with Deep Learning)

  • 박나윤;김지훈;김태민;송경진;변유진;강민주;전경구;김재곤
    • 산업경영시스템학회지
    • /
    • 제46권3호
    • /
    • pp.1-6
    • /
    • 2023
  • In the realm of dental prosthesis fabrication, obtaining accurate impressions has historically been a challenging and inefficient process, often hindered by hygiene concerns and patient discomfort. Addressing these limitations, Company D recently introduced a cutting-edge solution by harnessing the potential of intraoral scan images to create 3D dental models. However, the complexity of these scan images, encompassing not only teeth and gums but also the palate, tongue, and other structures, posed a new set of challenges. In response, we propose a sophisticated real-time image segmentation algorithm that selectively extracts pertinent data, specifically focusing on teeth and gums, from oral scan images obtained through Company D's oral scanner for 3D model generation. A key challenge we tackled was the detection of the intricate molar regions, common in dental imaging, which we effectively addressed through intelligent data augmentation for enhanced training. By placing significant emphasis on both accuracy and speed, critical factors for real-time intraoral scanning, our proposed algorithm demonstrated exceptional performance, boasting an impressive accuracy rate of 0.91 and an unrivaled FPS of 92.4. Compared to existing algorithms, our solution exhibited superior outcomes when integrated into Company D's oral scanner. This algorithm is scheduled for deployment and commercialization within Company D's intraoral scanner.

백색광 스캐너로 채득된 치과용 디지털모형의 정확도와 신뢰도 평가 (Evaluations of the Accuracy and Reliability of Measurements Made on White Light Scanner-based Dental Digital Models)

  • 김기백;김재홍
    • 한국콘텐츠학회논문지
    • /
    • 제12권10호
    • /
    • pp.357-364
    • /
    • 2012
  • 치과용 스캐너를 기반으로 하는 디지털 모형은 기존의 전통적인 석고모형을 대체할 만큼 발전되고 있다. 본 연구의 목적은 디지털모형의 정확도와 신뢰도를 평가하고자 하였다. 상악의 전악모형을 주 모형으로 설정하여 주 모형으로부터 석고모형을 제작하였고(N=10), 치과용 백색광 스캐너를 이용하여 10개의 디지털모형 데이터를 채득하였다. 제작된 두 실험군(석고모형, 디지털모형)을 1명의 검사자가 2회에 걸쳐서 6곳의 계측지점을 측정하였다. 짝 표본 t-검정과 급내 상관계수을 이용하여 통계적인 분석을 하였다. 실험결과 측정값의 검사자 내 신뢰도는 급내 상관계수 결과 두 실험군 0.75에서 0.87의 범위를 보였다. 석고모형과 디지털 모형의 평균 오차값은 0.11mm에서 0.23mm의 범위를 나타내었고, 모든 계측지점에서 통계적으로 유의한 차이를 보였다(P<0.05). 본 실험결과 모든 계측지점에서 적정수준의 정확성은 확보되지 않았으나, 선행연구에 비추어 볼 때 임상적인 효용성은 검증되었다. 추가적으로 임상적인 사례를 통해 평가되어야 할 것으로 사료된다.

Optical Coherence Tomography Applications for Dental Diagnostic Imaging: Prototype System Performance and Preclinical Trial

  • Eun Seo Choi;Won-Jin Yi;Chang-Seok Kim;Woosub Song;Byeong-il Lee
    • Current Optics and Photonics
    • /
    • 제7권3호
    • /
    • pp.283-296
    • /
    • 2023
  • An intraoral spectral domain optical coherence tomography (SD-OCT) system has been developed, using a custom-built hand-held scanner and spectrometer. The hand-held OCT probe, based on a microelectromechanical systems scanner and a self-built miniaturized drive circuit, had a field of view sufficient for dental diagnosis. The spectrometer using a fabricated f-theta lens provided the image depth required for dental diagnosis. The axial and transverse resolutions of the OCT system in air were 7.5 ㎛ and 12 ㎛ respectively. The hand-held probe could scan an area of 10 × 10 mm2, and the spectrometer could image along a depth of 2.5 mm. To verify the utility of the developed OCT system, OCT images of tooth hard and soft tissues were acquired, and a user-interface program for diagnosis was developed. Early caries and microcracks that were difficult to diagnose with existing methods could be found, and the state of restoration could be observed. Measuring the depth of the gingival sulcus, distinguishing subgingival calculus, and detecting an implant under the gingiva suggested the possibility of the SD-OCT system as a diagnostic for dental soft tissues. Through the presented OCT images, the capability of the developed SD-OCT system for dental diagnosis was demonstrated.

Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form

  • Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.354-362
    • /
    • 2016
  • PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (${\alpha}=.05$). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.

Creating a digitized database of maxillofacial prostheses (obturators): A pilot study

  • Elbashti, Mahmoud;Hattori, Mariko;Sumita, Yuka;Aswehlee, Amel;Yoshi, Shigen;Taniguchi, Hisashi
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.219-223
    • /
    • 2016
  • PURPOSE. This study aimed to create a digitized database of fabricated obturators to be kept for patients' potential emergency needs. MATERIALS AND METHODS. A chairside intraoral scanner was used to scan the surfaces of an acrylic resin obturator. The scanned data was recorded and saved as a single standard tessellation language file using a three-dimensional modeling software. A simulated obturator model was manufactured using fused deposition modeling technique in a three-dimensional printer. RESULTS. The entire obturator was successfully scanned regardless of its structural complexity, modeled as three-dimensional data, and stored in the digital system of our clinic at a relatively small size (19.6 MB). A simulated obturator model was then accurately manufactured from these data. CONCLUSION. This study provides a proof-of-concept for the use of digital technology to create a digitized database of obturators for edentulous maxillectomy patients.

Intraoral Scanner로 촬영된 치아 이미지의 정렬 (Registration of Dental Range Images from a Intraoral Scanner)

  • 고민수;박상철
    • 한국CDE학회논문집
    • /
    • 제21권3호
    • /
    • pp.296-305
    • /
    • 2016
  • This paper proposes a framework to automatically align Dental range image captured by depth sensors like the Microsoft Kinect. Aligning dental images by intraoral scanning technology is a difficult problem for applications requiring accurate model of dental-scan datasets with efficiency in computation time. The most important thing in dental scanning system is accuracy of the dental prosthesis. Previous approaches in intraoral scanning uses a Z-buffer ICP algorithm for fast registration, but it is relatively not accurate and it may cause cumulative errors. This paper proposes additional Alignment using the rough result comes after intraoral scanning alignment. It requires that Each Depth Image of the total set shares some overlap with at least one other Depth image. This research implements the automatically additional alignment system that aligns all depth images into Completed model by computing a network of pairwise registrations. The order of the each individual transformation is derived from a global network and AABB box overlap detection methods.

Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision

  • Jeon, Jin-Hun;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.468-473
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. MATERIALS AND METHODS. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by $10^{\circ}-20^{\circ}$ and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal-Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann-Whitney U test with Bonferroni correction (${\alpha}=.05$). RESULTS. Precision discrepancies for the canine, premolar, and molar were $3.7{\mu}m$, $3.2{\mu}m$, and $7.3{\mu}m$, respectively, indicating the poorest precision for the molar (P<.001). Trueness discrepancies for teeth types were $6.2{\mu}m$, $11.2{\mu}m$, and $21.8{\mu}m$, respectively, indicating the poorest trueness for the molar (P=.007). CONCLUSION. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.