• Title/Summary/Keyword: Dental resins

Search Result 257, Processing Time 0.026 seconds

Evaluation of the accuracy of provisional restorative resins fabricated using dental 3D printers (치과용 3D 프린터로 제작된 임시 수복용 레진의 정확도 평가)

  • Kim, Min-su;Kim, Won-Gi;Kang, Wol
    • Journal of Korean society of Dental Hygiene
    • /
    • v.19 no.6
    • /
    • pp.1089-1097
    • /
    • 2019
  • Objectives: The purpose of this study is to assess the accuracy of provisional restorative resins fabricated using dental three-dimensional (3D) printers. Methods: Provisional restorative resins were fabricated using the first molar of the right mandibular. Three groups comprising a total of 24 samples of such resins were fabricated. The prepared abutment was scanned initially and then designed using a computer-aided design (CAD) software. The conventional subtractive manufacturing system was employed to fabricate the first group of resins, while the second and third groups were fabricated using a digital light processing (DLP) 3D printer and a stereolithography (SLA) 3D printer, respectively. The internal surfaces of the resins were scanned and 3D measurements of the resins were taken to confirm their accuracy. Results: The root-mean-square deviation (RMS±SD) of the accuracy of the resins fabricated using the conventional subtractive manufacturing system, DLP 3D printer, and SLA 3D printer were 68.83±2.22 ㎛, 74.63±6.23 ㎛, and 61.74±4.09 ㎛, respectively. A one-way analysis of variance (ANOVA) test showed significant differences between the three groups (p < 0.05). Conclusions: Provisional restorative resins fabricated using DLP and SLA 3D printers demonstrated clinically-acceptable results.

Mechanical properties and antibacterial effects on Streptococcus mutans of composite resins containing phytoncide (피톤치드를 함유한 복합레진의 기계적 특성 및 Streptococcus mutans에 대한 항균 효과)

  • Lee, Myung-Jin;Kim, Dan-Bi;Kim, Ji-Eun;Moon, Seung-Ha;Son, Ji-Young;Lee, Eun-Young;Kwon, Jae-Sung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.19 no.4
    • /
    • pp.467-477
    • /
    • 2019
  • Objectives: The aim of this study is to investigate the mechanical properties and antibacterial effects on Streptococcus mutans of composite resins containing phytoncide. Methods: Phytoncide was mixed with commercial composite resins at 0 (control), 1.25, 2.5, 3.75, and 5.0 weight percentage (wt%). Mechanical properties related to composite resins such as surface hardness, depth of cure, and flexural strength were measured. Antibacterial effects of composite resins were analyzed by using Streptococcus mutans (ATCC 25175). The results were analyzed by one-way analysis of variance followed by Tukey's test (p<0.05). Results: Composite resins that contain low wt% of phytoncide demonstrated no significant difference in surface hardness, depth of cure, and flexural strength (p>0.05). However, composite resins that contain high wt% of phytoncide had significantly decreased mechanical properties (p<0.05). In terms of antibacterial effects, composite resins containing phytoncide inhibited the growth of S. mutans. Conclusions: Our findings suggest that novel composite resins containing phytoncide have effective antibacterial properties while maintaining the originally important mechanical features of composite resins.

A study on the microhardness and the marginal fitness of the various composite resins (수종의 복합레진에 대한 미세경도와 변연적합도 비교)

  • Kim, So-Min;Cho, Ja-Won;Hwang, Kyung-Sook;Kim, Wook-Tae;Kang, You-Hwa;Kim, Nam-Joong
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.147-156
    • /
    • 2011
  • Purpose: The author performed experiments on the microhardness and the marginal fitness of composite resins after polymerizing 4 kinds of composite resins on MOD standard specimens. Methods: For this study, in order to compare the microhardness and the marginal fitness of 4 kinds of composite resins. Results: The results are as follows. 1. In case of the microhardness, Tescera scored the highest among the four kinds of composite resins. 2. In case of the marginal fitness, Premise Indirect scored the highest. However, there was no statistically significant difference, all staying in clinically practical range. 3. Considering the above results, among the four kinds of composite resins, the author advises to use Tescera during teeth restoration which scored the highest in the micro- hardness. Conclusion: Conclusion: All of the composite marginal fitness were within the clinically useful range.

Physical Properties of Light Cured Dental Composite Resin with Novel Photosensitizers (새로운 광증감제를 사용한 치과용 광중합형 복합레진의 기계적 특성)

  • Sun, Gum-Ju;Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: The purpose of this study was to know the physical properties of UDMA dental composite resins containing two photosensitizers, PD, DA, as a photosensitizer instead of CQ. We want to know Remaining Double Bond(RDB) of UDMA unfilled resin and diametral tensile strength and flexural strength of composite resin containing PD and DA were compared with those of CQ, most widely used photosensitizer for dental composite resins. Methods: The RDB of UDMA studied by FT-IR spectroscopy increased with irradiation time. The composite resins were tested for their physical properties. The dental composite resins were made with UDMA as a monomer, silanized silica as filler, N,N-dimethylaminoethyl methacrylate (DAEM) as amine initiator, and one of the two kinds of new photosensitizers. Results: The relative RDB of UDMA was in the order: DA > CQ > PD but the physical properties of the composite resins show PD and DA with higher results compared with that containing CQ. The reason for the results is that PD and DA serve not only as a photosensitizer but also as a photo-crosslinking agent. Conclusion: PD and DA show as effective photosensizers, suitable for UDMA dental composite resin compare with a higher efficiency than CQ.

THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS (치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 -)

  • Lee Yong-Keun;Lee Keon-Il;Jung Sung-Woo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

A Study on the Color Stability of Temporary Resins according to Polymerizing Methods and Staining (온성 방법에 따른 수종의 임시 수복용 레진의 착색시의 색 안정성에 관한 연구)

  • Park, Sung-Ho;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • Dental temporary resin should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental temporary resin has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 resins($Snap^{(R)}$, Temporary bridge $resin^{(R)}$, Trim $II^{(R)}$) according to polymerizing methods and stainning. The resins were divided into groups by 2 types of polymerizing methods ( air or pressure and heat curing) The resins were dyed with coffee, chlorhexidine and artificial saliva and then the color stability was evaluated with a spectrophotometer(CM-503i, Minolta, Japan). The results were as follows ; 1. In the color stability according to polymerizing method, pressure and heat polymerizing method was higher than air polymerizing method. 2. The color stability according to staining fluid decreased in the order of I, II, III group, there was significant difference among the groups of staining fluid. 3. The color stability according to resins decreased in the order of $Snap^{(R)}$, Trim $II^{(R)}$, Temporary Bridge $resin^{(R)}$, The $Snap^{(R)}$ resin was highest color stability, there was significant difference among the 3 resins.

  • PDF

Tribological Evaluation of Dental Composite Resins Containing Prepolymerized Particle Fillers

  • Ren, Jing-Ri;Kim, Kyo-Han;Kim, Seock-Sam
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.727-734
    • /
    • 2001
  • The Tribological evaluation of commercial dental composite resins containing prepolymerized particle fillers was investigated. Composite resins such as Metafil, Silux Plus, Heliomolar, and Palfique Estelite were selected as specimens. In the wear tests, a ball-on-flat wear test method was used. The friction coefficient of Metafil was quite high. The wear resistance of Silux Plus and Palfique Estelite was better than that of Metafil and Heliomolar under the same experimental conditions. The main wear mechanism of the composite resins containing prepolymerized particle fillers was abrasive wear caused by the brittle fracture of the prepolymerized particles and the debonding of the filler and the matrix.

  • PDF

A STUDY OF MICROHARDNESS AND POLYMERIZATION SHRINKAGE OF PACKABLE RESINS (Packable resin의 미세경도와 경화수축)

  • Son, Deok-Il;Nam, Soon-Hyeun;Kim, Hyun-Jung;Seol, Hyo-Joung;Kwon, Yong-Hoon;Kim, Hyung-Il;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.534-540
    • /
    • 2004
  • Packable resins have been introduced in the market with high expectations as an alternative to amalgam. They are characterized by a high-filler load and a filler distribution that gives them a different consistency compared with the hybrid resins. The effect of high filler load on the microhardness and polymerization shrinkage of packable resins was tested. Hybrid resins were also tested to compared with the packable resins. As a result, packable resins showed a much greater microhardness value than hybrid resins. All the tested resins have a correlationship with the microhardness and filler content (vol%). The packable resins showed much less polymerization shrinkage than hybrid resins. The filler content and polymerization shrinkage were inversely correlated in the tested resins.

  • PDF

Evaluation of surface gloss of composite resins (복합레진의 표면 광택에 대한 평가)

  • Ji-Eun Byun
    • Journal of Korean Academy of Dental Administration
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2023
  • Composite resins, commonly used in clinical practice, have been developed to improve aesthetics to obtain smooth surfaces. Although the restored composite resin has a smooth surface, it gradually becomes rough over time. Therefore, this study measured glossiness to evaluate the surface of various composite resins and attempted to evaluate the maintenance of glossiness of composite resins by observing surfaces that change to roughness. Specimens were produced using resin used in clinical practice: Gradia direct anterior (GA), Tetric N-Ceram (TN), Ceram.X Sphere TEC one (CX), Filtek Z350XT (FT), Estelite sigma quick (ES). After creating a smooth surface with slide glass, five locations were randomly selected to measure surface gloss, and the average was the representative value of the specimen. Roughness was applied to the specimen under water pouring at the same speed and pressure using SiC paper #2400, 1200, and 400. The gloss unit of different SiC papers was measured. To evaluate the gloss unit and gloss retention between composite resins, one-way analysis of variance and Tukey multiple comparisons test were used. As a result of the study, there was a difference in gloss unit of specimens produced under the same conditions. Although the degree differed depending on the composite resin, there was also a difference in gloss retention. Based on the findings, composite resins show differences in gloss due to their different characteristics. Ceram.X Sphere TEC one (CX) showing the lowest gloss retention and Estelite sigma quick (ES) showing the highest.

The Measurement of Exothermic Temperature During Polymerization of Various Direct Resins. (각종 치과용 다이렉트 레진의 중합 반응시 열 측정)

  • Yun, Joung-Hyun
    • The Journal of the Korean dental association
    • /
    • v.11 no.1
    • /
    • pp.37-40
    • /
    • 1973
  • The auther measured exothermic tempreature of the 5 kinds of direct resins during polymerization. Direct resins were mixed into the rubber cup(550-600㎣ in volume) with grass rod at room temperature (23.6℃) for 30 seconds and thermometer was placed approximately at the geometric center of the resin mass in the rubber cup. Polymer-monomer ratio was determined by instruction of the packages. The results were as follows. 1) The heat generated during polymerization was under 47.3℃. 2) The time at which the highest temperature is reached during polymerization was within 20.5 minutes. 3) Slow curing resins produced lower heat than quick curing resins and quick curing resins presented higher temperature than slow curing resins. 4) The highest temperature was sustained momentarily.

  • PDF