• 제목/요약/키워드: Dental post material

검색결과 100건 처리시간 0.027초

Fabrication of a custom polyetherketoneketone post-and-core with digital technology

  • Ju-Hyoung Lee;Gyu-Heon Lee
    • 대한치과기공학회지
    • /
    • 제46권1호
    • /
    • pp.15-19
    • /
    • 2024
  • An ideal post material should have physical properties similar to those of dentin. Post materials with high elastic moduli may cause root fractures. This clinical report describes the treatment of a severely damaged tooth using a recently introduced material. Polyetherketoneketone (PEKK) is a semicrystalline high-performance thermoplastic polymer. PEKK is a promising material for custom post-and-core fabrication because of its elasticity close to that of dentin, good shock absorbance, machinability, and low cost. A laboratory scanner was used to digitize the conventional impression of a severely damaged maxillary right first molar. A custom PEKK post-and-core was designed and milled using computer-aided design and computer-aided manufacturing technology. Using the proposed technique, a custom PEKK post-and-core was fabricated accurately and human error was reduced. Restoration was luted with resin cement. Custom PEKK post-and-core restorations are a viable alternative for treating severely damaged teeth.

근관치료 영역에서 치과용 미세현미경의 활용 (Application of dental microscope in endodontic treatment procedure.)

  • 최성백
    • 대한치과의사협회지
    • /
    • 제55권8호
    • /
    • pp.542-555
    • /
    • 2017
  • 1. Diagnosis Diagnosis of Crack, Direct pulp capping 2. Access opening Find the calcified canal orifice Removal of dentin shelf Obtaining the MB2 canal (MB2, MB3, DB2) 3. Perforation repair during endodontic treatment 4. Removal of the separated files 5. Open apex treatment 6. Void removal on CWT procedure 7. Re-endodontic treatment Removal of restorative material filled in pulp chamber Post removal Identification and removal of residual gutta-perch 8. Surgical endodontic treatment In each case will overview how to use a dental microscope.

  • PDF

Dental fiber-post resin base material: a review

  • Lamichhane, Aashwini;Xu, Chun;Zhang, Fu-Qiang
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.60-65
    • /
    • 2014
  • Teeth that have short clinical crown, which are not alone enough to support the definitive restoration can be best treated using the post and core system. The advantages of fiber post over conventional metallic post materials have led to its wide acceptance. In addition to that the combination of aesthetic and mechanical benefits of fiber post has provided it with a rise in the field of dentistry. Also the results obtained from some clinical trials have encouraged the clinicians to use the fiber posts confidently. Fiber posts are manufactured from pre-stretched fibers impregnated within a resin matrix. The fibers could that be of carbon, glass/silica, and quartz, whereas Epoxy and bis-GMA are the most widely used resin bases. But recently studies are also found to be going on for polyimide as possible material for the fiber post resin base as a substitute for the conventional materials.

Post space preparation timing of root canals sealed with AH Plus sealer

  • Kim, Hae-Ri;Kim, Young Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.27-33
    • /
    • 2017
  • Objectives: To determine the optimal timing for post space preparation of root canals sealed with epoxy resin-based AH Plus sealer in terms of its polymerization and influence on apical leakage. Materials and Methods: The epoxy polymerization of AH Plus (Dentsply DeTrey) as a function of time after mixing (8, 24, and 72 hours, and 1 week) was evaluated using Fourier transform infrared (FTIR) spectroscopy and microhardness measurements. The change in the glass transition temperature ($T_g$) of the material with time was also investigated using differential scanning calorimetry (DSC). Fifty extracted human single-rooted premolars were filled with gutta-percha and AH Plus, and randomly separated into five groups (n = 10) based on post space preparation timing (immediately after root canal obturation and 8, 24, and 72 hours, and 1 week after root canal obturation). The extent of apical leakage (mm) of the five groups was compared using a dye leakage test. Each dataset was statistically analyzed by one-way analysis of variance and Tukey's post hoc test (${\alpha}=0.05$). Results: Continuous epoxy polymerization of the material with time was observed. Although the $T_g$ values of the material gradually increased with time, the specimens presented no clear $T_g$ value at 1 week after mixing. When the post space was prepared 1 week after root canal obturation, the leakage was significantly higher than in the other groups (p < 0.05), among which there was no significant difference in leakage. Conclusions: Poor apical seal was detected when post space preparation was delayed until 1 week after root canal obturation.

Physical and mechanical changes on titanium base of three different types of hybrid abutment after cyclic loading

  • Rimantas Oziunas;Jurgina Sakalauskiene;Laurynas Staisiunas;Gediminas Zekonis;Juozas Zilinskas;Gintaras Januzis
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권1호
    • /
    • pp.33-43
    • /
    • 2023
  • PURPOSE. This study investigated the physical and mechanical changes in the titanium base of three different hybrid abutment materials after cyclic loading by estimating the post-load reverse torque value (RTV), compressive side fulcrum wear pattern of titanium base, and surface roughness. MATERIALS AND METHODS. A total of 24 dental implants were divided into three groups (n = 8 each): Group Z, LD, and P used zirconia, lithium disilicate, and polyetheretherketone, respectively, for hybrid abutment fabrication. RTV was evaluated after cyclic loading with 50 N for 1.2 × 106 chewing cycles. The compressive sides of the titanium bases were analyzed using a scanning electron microscope, and the roughness of the affected areas was measured using an optical profilometer after loading. Datasets were analyzed using Kruskal-Wallis test followed by Mann-Whitney tests with the Bonferroni correction (α = .05). RESULTS. Twenty-three samples passed the test; one LD sample fractured after 770,474 cycles. Post-load RTV varied significantly depending on the hybridabutment material (P = .020). Group P had a significantly higher median of post-load RTVs than group Z (16.5 and 14.3 Ncm, respectively). Groups LD and P showed minor signs of wear, and group Z showed a more pronounced wear pattern. While evaluating compressive side affected area roughness of titanium bases, lower medians were shown in group LD (Ra 0.16 and Rq 0.22 ㎛) and group P (Ra 0.16 and Rq 0.23 ㎛) than in group Z (Ra 0.26 and Rq 0.34 ㎛); significant differences were found only among the unaffected surface and group Z. CONCLUSION. The hybrid abutment material influences the post-load RTV. Group Z had a more pronounced wear pattern on the compressive side of titanium base; however, the surface roughness was not statistically different among the hybridabutment groups.

Fracture resistance of upper central incisors restored with different posts and cores

  • Rezaei Dastjerdi, Maryam;Amirian Chaijan, Kamran;Tavanafar, Saeid
    • Restorative Dentistry and Endodontics
    • /
    • 제40권3호
    • /
    • pp.229-235
    • /
    • 2015
  • Objectives: To determine and compare the fracture resistance of endodontically treated maxillary central incisors restored with different posts and cores. Materials and Methods: Forty-eight upper central incisors were randomly divided into four groups: cast post and core (group 1), fiber-reinforced composite (FRC) post and composite core (group 2), composite post and core (group 3), and controls (group 4). Mesio-distal and bucco-lingual dimensions at 7 and 14 mm from the apex were compared to ensure standardization among the groups. Twelve teeth were prepared for crown restoration (group 4). Teeth in other groups were endodontically treated, decoronated at 14 mm from the apex, and prepared for posts and cores. Resin-based materials were used for cementation in groups 1 and 2. In group 3, composite was used directly to fill the post space and for core build-up. All samples were restored by standard metal crowns using glass ionomer cement, mounted at $135^{\circ}$ vertical angle, subjected to thermo-mechanical aging, and then fractured using a universal testing machine. Kruskal-Wallis and Mann-Whitney U tests were used to analyze the data. Results: Fracture resistance of the groups was as follows: Control (group 4) > cast post and core (group 1) > fiber post and composite core (group 2) > composite post and core (group 3). All samples in groups 2 and 3 fractured in restorable patterns, whereas most (58%) in group 1 were non-restorable. Conclusions: Within the limitations of this study, FRC posts showed acceptable fracture resistance with favorable fracture patterns for reconstruction of upper central incisors.

여러가지 post-and-core로 수복된 상악 중절치의 유한요소법적 연구 (FINITE ELEMENT ANALYSIS OF MAXILLARY CENTRAL INCISORS RESTORED WITH VARIOUS POST-AND-CORE APPLICATIONS)

  • 서민석;손원준;이우철;유현미;조병훈;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.324-332
    • /
    • 2009
  • 근관 치료된 치아의 수복에 있어서 파절은 가장 중요하게 고려되는 점이다. 포스트를 사용해서 수복한다는 것은 치수와 다른 단단한 물질을 근관 내에 삽입한다는 것으로 자연스럽지 못한 구조를 만들어서 고유의 응력분산을 변화시킨다. 오랫동안 수많이 in vitro 연구들이 post-and-core로 수복된 치아의 파절 저항에 대해서 이루어졌지만 어떤 것이 최상의 선택인지에 대해서는 많은 상충되는 관점들이 존재한다. 본 연구의 목적은 유한요소분석법을 사용하여 post-and-core system의 물리적인 성질이 치질의 응력분산에 미치는 영향을 분석하고 어떤 조합이 파절 저항에 도움이 되는지를 알아보는 것이다. 근관 치료된 상악 중절치를 삼차원 유한 요소법으로 Modeling하였다. 1.5 mm의 ferrule 높이를 부여하고 외관은 zirconia ceramic crown으로 지정하였다. 세가지 평행한 형태의 포스트 (zirconia ceramic, glass fiber, and stainless steel)와 두 가지 코어 (Paracore and Tetric ceram) 물질을 6개의 모델로 조합하였다. 각각의 모델은 해면골, 피질골, 치주인대, 그리고 4 mm 근관 충전을 가지도록 설계하였다. 50 N의 정적인 교합력이 치아 장축에서 60도 각도로 치관의 설면에 적용시켰다. 모델들의 응력전달 특징의 차이를 분석하였고, 결과를 나타내는 데는 Maximum von Mises stress 값을 사용하였고 최대 변위량과 정수압도 계산하였다. Glass fiber post로 수복된 경우 높은 탄성계수를 가진 레진 코어 모델 (29.14 MPa)에서 낮은 탄성계수의 코어 모델 (29.21 MPa)보다 더 낮은 응력이 발생하였다. Glass fiber post로 수복된 모델 (0.03497-0.03499 mm)은 다른 포스트로 수복된 모델들 (0.03245-0.03452 mm)보다 더 많은 최대 변위량을 보였다. 이는 glass fiber post로 수복된 치아의 경우가 상대적으로 치아에 가해지는 힘에 의해 더 많이 움직였다는 것을 보여준다. Zirconia ceramic 이나 stainless steel 과 같이 탄성계수가 큰 포스트는 응력을 증가시키지만 포스트가 스트레스를 대부분 흡수하여 치질에는 스트레스가 낮게 나타났다. Glass fiber post로 수복된 모델에서는 코어와 크라운이 만나는 순면 치경부에서 가장 높은 응력이 발생하였다.

Influence of wound closure on volume stability with the application of different GBR materials: an in vitro cone-beam computed tomographic study

  • Naenni, Nadja;Berner, Tanja;Waller, Tobias;Huesler, Juerg;Hammerle, Christoph Hans Franz;Thoma, Daniel Stefan
    • Journal of Periodontal and Implant Science
    • /
    • 제49권1호
    • /
    • pp.14-24
    • /
    • 2019
  • Purpose: To assess the influence of using different combinations of guided bone regeneration (GBR) materials on volume changes after wound closure at peri-implant dehiscence defects. Methods: In 5 pig mandibles, standardized bone defects were created and implants were centrally placed. The defects were augmented using different combinations of GBR materials: xenogeneic granulate and collagen membrane (group 1, n=10), xenogeneic granulate and alloplastic membrane (group 2, n=10), alloplastic granulates and alloplastic membrane (group 3, n=10). The horizontal thickness was assessed using cone-beam computed tomography before and after suturing. Measurements were performed at the implant shoulder (HT0) and at 1 mm (HT1) and 2mm (HT2) below. The data were statistically analysed using the Wilcoxon signed-rank test to evaluate within-group differences. Bonferroni correction was applied when calculating statistical significance between the groups. Results: The mean horizontal thickness before suturing was $2.55{\pm}0.53mm$ (group 1), $1.94{\pm}0.56mm$ (group 2), and $2.49{\pm}0.73mm$ (group 3). Post-suturing, the values were $1.47{\pm}0.31mm$ (group 1), $1.77{\pm}0.27mm$ (group 2), and $2.00{\pm}0.48mm$ (group 3). All groups demonstrated a loss of horizontal dimension. Intragroup changes exhibited significant differences in group 1 (P<0.001) and group 3 (P<0.01). Intergroup comparisons revealed statistically significant differences of the relative changes between groups 1 and 2 (P=0.033) and groups 1 and 3 (P=0.015). Conclusions: Volume change after wound closure was minimized by using an alloplastic membrane. The stability of the augmented horizontal thickness was most ensured by using this type of membrane irrespective of the bone substitute material used for membrane support.

Evaluation of the radiopacity of restorative materials with different structures and thicknesses using a digital radiography system

  • Yaylaci, Ayla;Karaarslan, Emine Sirin;Hatırli, Huseyin
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.261-269
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the radiopacities of various types of restorative materials with different thicknesses compared with enamel, dentin, and aluminum. Materials and Methods: Four bulk-fill resins, 2 hybrid ceramics, 2 micro-hybrid resin composites, 6 glass ionomer-based materials, 2 zinc phosphate cements, and an amalgam were used in the study. Twelve disk-shaped specimens were prepared from each of 17 restorative materials with thicknesses of 1 mm, 2 mm, and 4 mm (n=4). All the restorative material specimens with the same thickness, an aluminum (Al) step wedge, and enamel and dentin specimens were positioned on a phosphor storage plate and exposed using a dental X-ray unit. The mean gray values were measured on digital images and converted to equivalent Al thicknesses. Statistical analyses were performed using 2-way analysis of variance and the Bonferroni post hoc test(P<0.05). Results: Radiopacity was significantly affected by both the thickness and the material type (P<0.05). GCP Glass Fill had the lowest radiopacity value for samples of 1 mm thickness, while Vita Enamic had the lowest radiopacity value for 2-mm-thick and 4-mm-thick samples. The materials with the highest radiopacity values after the amalgam were zinc phosphate cements. Conclusion: Significant differences were observed in the radiopacities of restorative materials with different thicknesses. Radiopacity was affected by both the material type and thickness.