• Title/Summary/Keyword: Dental model

Search Result 1,377, Processing Time 0.028 seconds

The effect of low temperature aging on the mechanical property & phase stability of Y-TZP ceramics

  • Kim, Hyung-Tae;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.113-117
    • /
    • 2009
  • STATEMENT OF PROBLEM. Recently Yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) has been introduced due to superior flexural strength and fracture toughness compared to other dental ceramic systems. Although zirconia has outstanding mechanical properties, the phenomenon of decrease in the life-time of zirconia resulted from degradation in flexural strength after low temperature aging has been reported. PURPOSE. The objective of this study was to investigate degradation of flexural strength of Y-TZP ceramics after various low temperature aging treatments and to evaluate the phase stability and micro-structural change after aging by using X-ray diffraction analysis and a scanning electron microscope (SEM). MATERIAL AND METHODS. Y-TZP blocks of Vita In-Ceram YZ (Vita Zahnfabrik, Bad $S\ddot{a}ckingen$, Germany) were prepared in 40 mm (length) $\times$ 4 mm (width) $\times$ 3 mm (height) samples. Specimens were artificially aged in distilled water by heat-treatment at a temperature of 75, 100, 125, 150, 175, 200, and $225^{\circ}C$ for 10 hours, in order to induce the phase transformation at the surface. To measure the mechanical property, the specimens were subjected to a four-point bending test using a universal testing machine (Instron model 3365; Instron, Canton, Mass, USA). In addition, X-ray diffraction analysis (DMAX 2500; Rigaku, Tokyo, Japan) and SEM (Hitachi s4700; Jeol Ltd, Tokyo, Japan) were performed to estimate the phase transformation. The statistical analysis was done using SAS 9.1.3 (SAS institute, USA). The flexural strength data of the experimental groups were analyzed by one-way analysis of variance and to detect statistically significant differences ($\alpha$= .05). RESULTS. The mean flexural strength of sintered Vita In-Ceram YZ without autoclaving was 798 MPa. When applied aging temperature at below $125^{\circ}C$ for 10 hours, the flexural strength of Vita In-Ceram YZ increased up to 1,161 MPa. However, at above $150^{\circ}C$, the flexural strength started to decrease. Although low temperature aging caused the tetragonal-to-monoclinic phase transformation related to temperature, the minimum flexural strength was above 700 MPa. CONCLUSION. The monoclinic phase started to appear after aging treatment above $100^{\circ}C$. With the higher aging temperature, the fraction of monoclinic phase increased. The ratio of monoclinic/tetragonal + monoclinic phase reached a plateau value, circa 75% above $175^{\circ}C$. The point of monoclinic concentration at which the flexural strength begins to decrease was between 12% and 54%.

The Comparative Study of Effect on Speech before and after Orthognathic Surgery of Patients (악교정 환자의 악교정 수술전후 발음양상에 대한 비교연구)

  • Kwon, Kyung-Hwan;Kim, Soo-Nam;Lee, Dong-Keun;Cho, Yong-Min;Lee, Suk-Hyang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.2
    • /
    • pp.191-205
    • /
    • 2000
  • The purpose of this study was undertaken to determine the effects of orthognathic surgery on speech. The hyposis stated herein is that functional behaviors of the dentofacial complex, such as speech production, may be adversely affected by deviations of a structural nature(especially, Class III malocclusion). Twenty adults with Class III malocclusion(13 female and 7 male) were studied preoperative, immediate postoperative and either 6 or 12 months postoperative lateral cephalograms. They had mandibular prognathism and had undergone mandible setback operation. The position of tongue, soft palate(Uvula), hyoid bone, respiratory track width, and pharyngeal depth were assessed on lateral cephalograms with 23 cephalometric variables, ANOVA, Paired t-tests and Pearson's product-moment correlation coefficient tests were used to evalute the operative changes in all cephalometric parameters. A experienced speech and language pathologists performed narrow phonetic transcriptions of tape-recorded words and sentences produced by each of the ninth patients and the recording tapes were analyzed by phonetic computer program(Computerized Speech Lab(CSL) Model 4300BI(U.S.A.)) These judges also recorded their ratings of each patient's overall consonants, hypernasality, hyponasality, and articulation proficiency. The results obtained are as follows; 1. There were significant changes in distance of posterior pharyngeal wall to tongue (TI-TW2, TS-TW3) after the surgery at 6 months postoperatively(each p<0.01 p<0.05). 2. The posterior tongue point(TI, TS, PPT) moved posteriorly after surgery and remained to its changed position at 6 months postoperatively(p<0.05). The displacement of tongue was correlated with the movement of mandibular setback amount(p<0.05). The hyoid bone moved posteriorly superiorly after immediate postoperative period. There was significant changes in hyoid bone movement after immediated postoperative period(p<0.05), but returned to its original position during the follow-up period(p>0.05) 3. The soft palate was displaced posteriorly superiorly after immediated operative period and remained to its changed position at 6 months postoperatively(p<0.05). ANS-PNS-SPT angle increasing, PPU-PPPo distance narrowing was showed after surgery, and remained its appearance 6 months postoperatively(p<0.05). 4. There were significant changes in formant value and squre diagram of vowel sound after the orthognathic surgery and the follow-up period. There were significant changes in /ㅅ/sound and posterior tongue sound. 5. The posterior movement of tongue and the posteriosuperior movement of soft palate was correlated with mandibular setback amount after orthognathic surgery. On the vowel squre diagram, the author found that the place of articulation after operation moved downward, backward, upward. 6. In assessing speech abnormalities, dental occlusion should be considered as a contributing factor. The vast majority of subjects with preoperative misarticulations eliminated or reduced their errors following orthognathic surgery. There was significant difference in speech impovement between pre- and postoperation.

  • PDF

A Study on Reliability and Training of Face-Bow Transfer Procedure (안궁의 신뢰성과 학습효과에 관한 연구)

  • So, Woong-Seup;Choi, Dae-Kyun;Kwon, Kung-Rock;Lee, Seok-Hyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.297-308
    • /
    • 2003
  • Face-bow is used to transfer models to the articulator in diagnosing the patient or treating problems associated with occlusion. However, there have been few reports on the reliability of the face-bow procedure and the relationship between the experience of the operator and the reliability of the face-bow procedure. The purposes of this study are to examine the reliability of the face-bow procedure and to evaluate whether the face-bow transferring has any training effect. Nine dentists working at M hospital conducted a face-bow transfer in one patient having a normal dentition and interdental relationship. The procedure was done two times a week for four weeks. The maxillary model was mounted to the articulator every time, then the landmarks on the maxillary right first molar, the maxillary left central incisor, and the maxillary left first molar were measured with a special three-dimensional instrument. These data were input into a computer, and evaluated statistically. The results were as follows ; 1. When examined with ANOVA test, the results were p=0.2040 in maxillary right first molar, p=0.0578 in maxillary left incisor, and p=0.1433 in maxillary left first molar. There was no significant(0< $p{\leq}0.05$). 2. Training 1) The correlation coefficient between trial and rejection was -0.578 when analyzed with T-distribution. The more we tried, the less errors we found. 2) When the S.D. of the first three trials was compared to the S.D. of the last three trials in face-bow transfer, the results showed that the former was larger than the latter in thirty-nine times, and the latter was larger than the former in fifteen times. The more we tried face-bow transfer, the less errors we found. 3. When the S.D. of x, y, z coordinates were examined, the S.D. of x coordinates had the largest measurement in five times, the S.D. of y coordinates had the largest measurement in four times, and the S.D. of z coordinates had the largest measurement in nine times. The possibility which the error can occur in z coordinate was the highest.

A photoelastic Stress Analysis of Implant Prosthesis According to Fitness of Super structure (불량 적합 임플란트 보철물의 광탄성 응력 분석)

  • Lim, Hyun-Pil;Heo, Shin-Ok;Kim, Hong-Joo;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • To assess the stress distribution of implant prosthesis induced by intentional misfit using photoelastic model. Stress was measured at the surrounding bone after applying vertical load to the implant. Three implants were placed in each of three photoelastic resin blocks. No misfits were used for the control group, while for the experimental group $100{\mu}m$ misfit after cutting the crown was used. The photoelastic stress analysis was performed. In control group, stress concentration was not shown when the load was not applied, whereas stress concentration was shown only in the loaded part even when load was applied and the stress was distributed in anterior-posterior direction when applying a load in the middle. When intentional misfits were given, stress around the fixture was incurred when tightening the screw even if load was not applied. If the load was applied, stress was concentrated around the implants including areas where the load was applied. In particular, the prosthesis made of UCLA showed more stress concentration as compared with a conical abutment. In the UCLA case, concentration was shown from the apex following through the axis to the cervical area. Prosthesis with misfit makes the stress concentrated though the load was not applied and it induces even more severe stress concentration when the load was applied. This founding demonstrates the importance of the correct prosthesis production.

COMPARISON OF TRAMADOL/ACETAMINOPHEN AND CODEINE/ACETAMINOPHEN/IBUPROFEN IN ONSET OF ANALGESIA AND ANALGESIC EFFICACY FOR POSTOPERATIVE ACUTE PAIN (수술후 급성 동통에 대한 Tramadol/Acetaminophen과 Codeine/Acetaminophen/Ibuprofen의 효과 발현시점과 진통효과의 비교)

  • Jung, Young-Soo;Kim, Dong-Kee;Kim, Moon-Key;Kim, Hyung-Jun;Cha, In-Ho;Han, Moo-Young;Lee, Eui-Wung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.2
    • /
    • pp.143-149
    • /
    • 2004
  • Background: Some clinical trials have reported that a new analgesic combination of tramadol and acetaminophen provides good efficacy in various pain models. For the more clinical uses of this agent, comparisons about the onset of analgesia and analgesic efficacy in the acute state of pain with the other drugs known as strong analgesics were needed. Purpose: The goal of this study was to compare the times to onset of analgesia and the other analgesic efficacy of 75 mg tramadol/650 mg acetaminophen and 20 mg codeine/500 mg acetaminophen/400 mg ibuprofen in the treatment of acute pain after oral surgery. Patients and Methods: Using a randomized, single-dose, parallel-group, single-center, and active-controlled test design, this clinical study compared the times to onset of analgesia using a two-stopwatch technique and the other analgesic efficacy of the single-dose tramadol/acetaminophen and codeine/acetaminophen/ibuprofen. These were assessed in 128 healthy subjects with pain from oral surgical procedures involving extraction of one or more impacted third molars requiring bone removal. From the time of pain development, the times to onset of perceptible and meaningful pain relief, pain intensity, pain relief, an overall assessment, and adverse events of the study medications were recorded for 6 hours. Results: The demographic distribution and baseline pain data in the two groups were statistically similar. The median times to onset of perceptible pain relief were 21.0 and 24.4 minutes in the tramadol/acetaminophen and codeine/acetaminophen/ibuprofen groups respectively and those to onset of meaningful pain relief were 56.4 and 57.3 minutes, which were statistically similar. The other efficacy variables such as mean total pain relief (TOTPAR) and the sum of pain intensity differences (SPID) were also similar in the early period after pain development and drug dosing. The safety of tramadol/acetaminophen was well tolerated and very comparable to that of codeine/acetaminophen/ibuprofen. Conclusions: In this acute dental pain model, the onset of analgesia and analgesic efficacy of tramadol/acetaminophen was comparable to that of codeine/acetaminophen/ibuprofen. These results showed that tramadol/acetaminophen was recommendable for fast and effective treatment in the management of postoperative acute pain.

AN EXPERIMENT STUDY ON THE BOND STRENGTH OF ADHESIVE RESINS TO SUEEXSSIVELY RECAST ALLOYS FOR REISN-BONDED RESTORATIONS (반복주조된 치과용 합금의 피착면 처리방법에 따른 접착성 수지와의 접착강도에 관한 실험적 연구)

  • Jung, Kum Tai;Yang, Jae Ho;Lee, Sun Hyung;Jung, Hun Yung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.53-76
    • /
    • 1990
  • The purpose of this study was to evaluate the tensile bond strength of adhesive resins to successively recast Rexillium III and Degudent-U. Recasting was done 4times successively. Specimen $A_1$, were cast by new metal, and $A_2$ by surpus of $A_1$, $A_3$ by surplus of, $A_2$ $A_4$ by surplus of $A_3$, $A_5$ by surplus of $A_4$ plus 50% new metal. The types of surface treatment for resinbonded restoration in this experiment were electrolytic etching by OXY-ETCH(Oxy dental products, Inc., Hillside, New Jersey, U.S,A.), aluminum oxide blasting, anodic oxidation by EZ-OXISOR( Towagiken Co., Kyoto, Japan), electrotinplating by Kura Ace(Kuralay Co., Kyoto, Japan). Three kinds of cementing resin used in this study were Comspan(K.P. Cauil Co, Milford Delaware, U.S.A.), Super Bond C&B(Sun-Medical Co. Ltd., Kyoto,Japan), Panavia EX(Kuralay Co., Ltd., Osaka, Japan). Tensile bond strength was measured by Instron Universal testing machineModel 1125) and all the specimen were observed with SEM(JEOL, JSM-T2000) and mode of bond failure were recorded. The obtained results were as follows : 1. In electrolytic etched group, tensile bond strength was decreassed when recast alloy was used, and tensile bond strength of Compan and panavia EX were not significantly different(P>0.05). 2. In remaining group treated by aluminum oxide blasting, EZ-OXIOR, Kura Ace, tensile bond strength were not changed when recast alloy were used, and tensile bond strength of SuperBond(C&B and Panavia EX were not significantly different(P>0.05). 3. IN SEM evaluation, electrolytic etched group and electrotinplated group exhibited different image when recast alloy was used, and remaining groups treated by aluminum oxide blasting, EZ-OXISOR exhibited the same. 4. IN observation of bond failure, electrolytic etched group exhibited adhesive failure and remaing groups treated by aluminium oxid blasting, EZ-OXISOR, Kura Ace exhibited adhesive and cohesive failure.

  • PDF

The Harmful Effects of Prolonged Strenuous Treadmill Exercise on Bronchoalveolar System in Rats (장시간의 고강도 트레드밀 운동이 기관지 폐포계에 미치는 유해한 효과)

  • Oh, Kyoung-Mo;Hyun, Kyung-Yae;Kim, Chi-Young;Choi, Seok-Cheol;Shin, Koon-Soo
    • Journal of Life Science
    • /
    • v.19 no.10
    • /
    • pp.1352-1359
    • /
    • 2009
  • We designed this study to investigate the effects of continuous strenuous aerobic exercise on the respiratory system in a rat model. After exercise for 8 weeks, rats' weights were higher in the exercise groups than in the Control group (non-exercise). Rats in Exercise-120 min group (Ex-120 group) had the lowest weights. Total leukocyte counts in bronchoalveolar lavage fluid (BALF) were higher in exercise groups than in Control group. The Ex-30 and Ex-120 groups had higher neutrophil counts, whereas that in the Ex-60 group was lower than in the Control group, and that in the Ex-30 group was the highest. Lymphocyte and monocyte counts were higher in all exercise groups than in the Control group, and those in the Exercise-120 min group were the highest. Interleukin-6 (IL-6) level was the highest, while IL-10, interferon-$\gamma$ and nitric oxide (NO) levels were the lowest in the Ex-120 group when compared to the Control and other exercise groups. These findings suggest that strenuous aerobic exercise for short periods (30 min) may have a beneficial effect on decrease in body weight, whereas prolonged-strenuous aerobic exercise (>1 hr) may be adverse to leukocyte and immune levels in the bronchoalveolar system, as well as result in an increased production of oxygen free radicals.

Positional symmetry of porion and external auditory meatus in facial asymmetry

  • Choi, Ji Wook;Jung, Seo Yeon;Kim, Hak-Jin;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.33.1-33.9
    • /
    • 2015
  • Background: The porion (Po) is used to construct the Frankfort horizontal (FH) plane for cephalometrics, and the external auditory meatus (EAM) is to transfer and mount the dental model with facebow. The classical assumption is that EAM represents Po by the parallel positioning. However, we are sometimes questioning about the possible positional disparity between Po and EAM, when the occlusal cant or facial midline is different from our clinical understandings. The purpose of this study was to evaluate the positional parallelism of Po and EAM in facial asymmetries, and also to investigate their relationship with the maxillary occlusal cant. Methods: The 67 subjects were classified into three groups. Group I had normal subjects with facial symmetry ($1.05{\pm}0.52mm$ of average chin deviation) with minimal occlusal cant (<1.5 mm). Asymmetry group II-A had no maxillary occlusal cant (average $0.60{\pm}0.36$), while asymmetry group II-B had occlusal cant (average $3.72{\pm}1.47$). The distances of bilateral Po, EAM, and mesiobuccal cusp tips of the maxillary first molars (Mx) from the horizontal orbital plane (Orb) and the coronal plane were measured on the three-dimensional computed tomographic images. Their right and left side distance discrepancies were calculated and statistically compared. Results: EAM was located 10.3 mm below and 2.3 mm anterior to Po in group I. The vertical distances from Po to EAM of both sides were significantly different in group II-B (p=0.001), while other groups were not. Interside discrepancy of the vertical distances from EAM to Mx in group II-B also showed the significant differences, as compared with those from Po to Mx and from Orb to Mx. Conclusions: The subjects with facial asymmetry and prominent maxillary occlusal cant tend to have the symmetric position of Po but asymmetric EAM. Some caution or other measures will be helpful for them to be used during the clinical procedures.

Comparative study of removal torque of 3 different hydroxyapatite coated implants in the femur of rabbits (가토의 대퇴골에 식립한 3종류의 수산화인회석 코팅 임플란트에 대한 제거회전력 비교 연구)

  • Kim, Sang-Soo;Lee, Ju-Hyung;Yu, Seok-Hyun;Lee, Hyung-Ju;Moon, Jee-Won;Park, In-Sook;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.49-53
    • /
    • 2011
  • Introduction: This study compared the strength of osseointegration as determined by the resistance to reverse torque rotation of three different hydroxyapatite coated implants in the rabbit femur model. Materials and Methods: Three hydroxyapatite coated implants (HAPTITE), Tapered Screw-Vent (TSV) and BioTite-H - were used. A total of 40 implants were placed in the femur of 20 adult male rabbits. The animals were divided into two groups. In group A (n=10); one HAPTITE was placed into each right femur and one TSV was placed into each left femur. In group B (n=10); one HAPTITE was placed into each right femur and one BioTite-H was placed into each left femur. Five rabbits of each group were sacrificed at 4 and 8 weeks. The implants were removed by reverse torque rotation using a digital torque-measuring device. A total of 40 implants in 20 rabbits were used for the removal torque measurements. Results: In the Group A, 4 weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $70.7{\pm}31.6$ N cm and $28.9{\pm}15.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $87.9{\pm}26.2$ N cm and $54.9{\pm}22.4$ N cm, respectively. In the Group B, 4 weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $58.0{\pm}29.6$ N cm and $37.7{\pm}14.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $91.4{\pm}47.1$ N cm and $30.8{\pm}9.8$ N cm. HAPTITE showed a higher removal torque than the other implants. Conclusion: These results suggest that HAPTITE increases the strength of osseointegration significantly as determined by the resistance to reverse torque rotation.

SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF ZIRCONIA CORE ON THE COLOR OF CERAMIC (지르코니아 코아가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석)

  • Pae Ah-Ran;Baik Jin;Woo Yi-Hyung;Kim Hyung-Sup;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.466-477
    • /
    • 2005
  • Statement of problem : Problem of matching the appearance of porcelain restorations with the patient's natural dentition has always been a concern to dental clinicians. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. Among the various factors, shade and translucency or the core can significantly affect the overall esthetics of the restoration and should be considered when selecting an all-ceramic system. Purpose : The purpose of this study was to spectrophotometrically evaluate the influence of different zirconia systems and core thickness on the final shade of all-ceramic restorations using the CIEL$^*a^*b^*$ system. Material and Methods: Core specimens (n : 20 per group) of In-Ceram Alumina, In-Ceram Zirconia, Digident CAD/CAM Zirconia, Cercon Zirconia were fabricated 20mm in diameter. 10 specimens of each group were fabricated at core thickness of 0.5mm and 0.7mm. These core specimens were veneered with shade Al & A3 porcelain of the recommended manufacturer. CIEL$^*a^*b^*$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan). Color differences were calculated using the equation ${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{\frac{1}{2}}$. Results : 1. Specimens of core thickness 0.5mm and 0.7mm did not exhibit clinically perceived color difference. 2. Regarding shade reproducibility, In-Ceram Alumina and In-Ceram Zirconia showed significant difference within each group. 3. Cercon Zirconia group showed the highest $L^*$ value and Digident Zirconia group showed lowest $a^*$ & $b^*$ value. 4. Generally the shade difference between materials was higher in the A3 shade group than in the Al shade group. Conclusion: Within the limitations of this study, there was no color difference after increase in core thickness and every all-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.