• 제목/요약/키워드: Dental internal adaptation

검색결과 32건 처리시간 0.026초

Micro-computed tomography in preventive and restorative dental research: A review

  • Ghavami-Lahiji, Mehrsima;Davalloo, Reza Tayefeh;Tajziehchi, Gelareh;Shams, Paria
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.341-350
    • /
    • 2021
  • Purpose: The use of micro-computed tomography (micro-CT) scans in biomedical and dental research is growing rapidly. This study aimed to explore the scientific literature on approaches and applications of micro-CT in restorative dentistry. Materials and Methods: An electronic search of publications from January 2009 to March 2021 was conducted using ScienceDirect, PubMed, and Google Scholar. The search included only English-language articles. Therefore, only studies that addressed recent advances and the potential uses of micro-CT in restorative and preventive dentistry were selected. Results: Micro-CT is a tool that enables 3-dimensional imaging on a small scale with very high resolution. In this method, there is no need for sample preparation or slicing. Therefore, it is possible to examine the internal structure of tissue and the internal adaptation of materials to surfaces without destroying them. Due to these advantages, micro-CT has been recommended as a standard imaging tool in dental research for many applications such as tissue engineering, endodontics, restorative dentistry, and research on the mineral density of hard tissues and bone growth. However, the high costs of micro-CT, the time necessary for scanning and reconstruction, computer expertise requirements, and the enormous volume of information are drawbacks. Conclusion: The potential of micro-CT as an emerging, accurate, non-destructive approach is clear, and the valuable research findings reported in the literature provide an impetus for researchers to perform future studies focusing on employing this method in dental research.

고정성 보철물의 적합도 측정 시 사용하는 실리콘 복제본 기술의 정확도 평가 (An Evaluation Validity of the Silicone Replica Technique at Measurement on Fit of Fixed Dental Prostheses)

  • 김재홍;김기백
    • 치위생과학회지
    • /
    • 제12권6호
    • /
    • pp.566-571
    • /
    • 2012
  • 제한된 조건 하에서 수행된 본 연구에서는 다음과 같은 결론을 얻었다. 1. 치형과 고정성 보철물을 근 원심 방향의 단면에 8지점을 선정한 후 서로 다른 두 가지 방식으로 적합도를 측정하여 비교한 결과 8지점 모두에서 유의한 차이를 보이지 않았다(p<0.05). 2. 8지점을 변연부, 경사부, 축벽부, 교합면으로 분류하여 비교한 결과에서도 역시 두 측정 방법 간에 유의한 차이를 보이지 않았다(p<0.05). 이와 같은 결과를 바탕으로 실리콘 복제본 기술을 이용하여 적합도를 측정하는 것이 치형과 고정성 보철물을 직접 절단하여 단면을 측정하는 것만큼 정확하다는 결론을 얻었다. 따라서 고정성 보철물의 적합도 측정 시 비 파괴적인 방법인 실리콘 복제본 기술을 이용한다면 치형과 고정성 보철물 모두 파괴하지 않고 측정이 가능할 것으로 사료된다.

고정성 보철물의 적합도에 대한 실험적 평가방법 (In vitro evaluation methods on adaptation of fixed dental prosthesis)

  • 이현호;이두형;이규복
    • 구강회복응용과학지
    • /
    • 제33권2호
    • /
    • pp.63-70
    • /
    • 2017
  • 임상적으로 고정성보철물의 적합도는 성공적인 수복을 위해 필수적인 요소이다. 보철물의 적합도는 크게 변연적합도와 내면적합도로 분류되며, 이를 평가하기 위한 방법으로는 현미경 변연 측정법, 절단면 측정법, 실리콘 복제법, 3차원 스캔데이터 중첩법, 무게 측정법, 마이크로 CT 측정법 등 다양한 방법들이 소개되고 있다. 이에 본 연구에서는 기존의 문헌들을 바탕으로 각 방법들의 장, 단점을 비교분석함으로써 디지털환경에서 보다 편리하고 정확한 측정법을 제시하고자 한다.

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

대학생들의 귀인성향과 학과 선택 시 우선고려사항에 따른 학과적응에 미치는 요인 (Relationship between University Student's attributional-style and learning Adaptation Considered in Department Selection)

  • 김기욱
    • 한국산학기술학회논문지
    • /
    • 제13권2호
    • /
    • pp.694-700
    • /
    • 2012
  • 본 논문은 대학생들을 대상으로 진학 시 학과결정에 영향을 미친 요인들과 입학 후 학업적응정도 및 귀인성향을 분석하여 고등학교 졸업 예정자 및 대학생들의 학과 선택, 진로선택 시 도움을 주고자 2011년 6월 1일부터 30일까지 287명의 설문 조사 자료를 이용하여 분석하였다. 연구결과 학과를 선택할 때 '인기도, 취업전망'이 64.5%로 가장 먼저 고려하는 것으로 조사되었고, 일반적 특성에 따른 학과 선택 시 우선순위는 성별에서 여자가 68.8%, 전공별에서는 보건계열이 78.7%가 '인기도, 취업전망'을 고려했다고 조사되어 유의하게 나타났다(P<0.05, P<0.01). 전공별 학업적응 및 귀인성향과의 관계에서는 보건계열에서는 동기화가 클수록 적용점수가 높을수록 학업적응력이 높게 나타났고, 귀인성향과의 관계에서는 보건계열이 내적귀인성향이 높게 나타나 유의한 차이를 나타냈다(P<0.05). 이상의 결과를 종합하면 학생이 가지고 있는 귀인성향을 바탕으로 내적귀인성향을 더 많이 발달시킬 수 있는 프로그램개발과 활용이 필요할 것이며, 계획적이고 신중한 학과선택을 위해 중학교나 고등학교 입학시기부터 대학생활의 전반적 사항이나 진로지도까지 진로탐색프로그램을 통한 복합적 상담이 이루어져야 차후 학과적응, 진로 적응도가 높을 것으로 사료된다.

Translation and validation of the Turkish version of the Psychosocial Impact of Dental Aesthetics Questionnaire

  • Aglarci, Cahide;Baysal, Asli;Demirci, Kadir;Dikmen, Ferhan;Aglarci, Ali Vasfi
    • 대한치과교정학회지
    • /
    • 제46권4호
    • /
    • pp.220-227
    • /
    • 2016
  • Objective: The aim of this study was to translate the Psychosocial Impact of Dental Aesthetics Questionnaire (PIDAQ) into Turkish, validate the questionnaire, and provide a cross-cultural adaptation. Methods: The translation process included the following steps, which were performed by a translation committee: (1) translation into Turkish, (2) back translation into English, (3) pretesting, and (4) cross-cultural adaptation. The Turkish version of the PIDAQ was produced subsequent to the translation process. Validity and reliability were measured using the Perception of Occlusion Scale and the aesthetic component of the Index of Orthodontic Treatment Need. The questionnaire was administered to 260 individuals (age range, 18-30 years; mean age, $20.50{\pm}1.9$ years). Structural validity was assessed via factor analysis, and internal consistency was measured using Cronbach's alpha coefficient. Results: Factor analysis revealed a four-factor structure, with factor loadings for included items ranging from 0.380 to 0.868. Few questions were shuffled among domains various factor loadings. Cronbach's alphas for the Turkish version of the PIDAQ ranged from 0.534 to 0.904. Mean scores for the PIDAQ subscale and total scores differed significantly according to Index of Orthodontic Treatment Need and Perception of Occlusion Scale scores. Conclusions: This study provided a Turkish version of the PIDAQ, which could be a useful tool in the evaluation of the psychosocial impact of malocclusion in young Turkish adults.

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교 (Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns)

  • 고인석;김정미;조혜원
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.226-233
    • /
    • 2016
  • 목적: 본 연구는 수복물의 적합도를 계측하는 두 가지 측정방법을 평가하기 위해 CAD-CAM (computer aided design-computer aided manufacturing)과 열가압 소성법으로 전부 도재관을 제작하고 micro CT와 cross-section technique으로 전부 도재관의 적합도를 비교하고자 하였다. 재료 및 방법: 하악 제 1대구치 레진 치아를 전부 도재관을 위한 지대치를 형성하고 PMMA (polymethylmethacrylate) 레진 블록을 가공하여 10개의 시편을 복제하였다. 복제한 레진 다이의 인상을 채득하고 모형을 제작하여 5개는 열가압 소성법으로 IPS e.max Press (Ivoclar Vivadent, Schaan, Liechtenstein) 도재관을 제작하였다. 다른 5개의 시편은 CAD-CAM 가공법(Ceramil motion 2, Amann Girrbach, Koblach, Austria)을 이용하여 IPS e.max CAD 도재관을 제작하였다. 각 레진 다이에 전부 도재관을 인산아연 시멘트(Fleck's zinc cement, Keystone industries, Gibbstown, NJ, USA)로 손가락 압력에 의해 합착하였다. 변연 및 내면 적합도를 측정하기 위해서 합착된 시편 10개를 먼저 micro CT로 촬영하여 협-설 시상면의 영상정보를 획득하였다. 그 후 절단 시편을 만들어 주사전자현미경으로 micro CT와 동일한 지점의 간극을 측정하였다. SPSS 22.0 프로그램을 이용하여 각 측정 지점에서 제작 방식별, 측정 방식별로 Mann-Whitney 검정 방법을 통해 유의차 검증을 시행하였다. 결과: Micro CT와 주사전자현미경으로 측정한 변연 및 내면 적합도는 유사하였으며, 통계적으로 유의한 차이를 보이지 않았다. 두 가지 제작법의 도재관은 변연 및 내면 적합도에 유의한 차이가 없었다. 결론: CAD-CAM과 열가압소성으로 제작한 전부 도재관은 적합도에 차이를 보이고 있지 않으며, Micro CT와 주사전자현미경을 이용한 측정 방식 모두 임상적으로 이용 가능할 것으로 사료된다.

일부 치위생과 학생의 자기인식 및 타인인식이 대학생활 적응에 미치는 영향 (The Effect of Self-Awareness and Other-Awareness on College Life adjustment in Dental Hygiene Students)

  • 이지영
    • 대한치위생과학회지
    • /
    • 제6권2호
    • /
    • pp.161-172
    • /
    • 2023
  • 연구배경: 치위생과 학생들의 자아인식과 타인인식, 대학생활 적응 정도를 알아보고 대학생활 적응에 미치는 요인을 파악하고자 한다. 연구방법: 치위생과 재학생 191명을 대상으로 설문조사에 동의를 구하고 G*power 3.1.9.4 program으로 효과 크기를 산출하였다. 일반적 특성에 따른 자기인식, 타인인식, 대학생활적응의 차이와 상관관계 및 대학생활 적응에 영향요인을 알아보기 위해 독립 표본 t-test 및 일원 배치 분산분석, 사후분석 scheffe, 상관분석과 다중회귀분석을 실시하였다. 연구결과: 대학생활 적응은 자기인식(r=.301)에서 유의한 정(+)의 상관관계가 나타났고, 하위 요인과의 관련성은 사회적 적응과 사적 자기인식(r=.340), 공적 자기인식(r=.331)에서 가장 높은 정(+)의 상관관계가 나타났다(p<0.01). 타인인식(r=-.051)은 대학생활 적응과 부(-)의 관련성을 보였으나 통계적으로 유의한 차이는 나타나지 않았다. 대학생활 적응 요인으로는 사적 자기인식(β=.232)과 공적 자기인식(β=.254)이 정(+)의 영향을 주었고, 내적 타인인식(β=-.205)이 부(-)의 영향을 주는 것으로 나타났다(p<0.01) 결론: 치위생과 학생들의 자기인식과 타인인식은 원만한 대학생활 적응에 영향요인으로 대학 생활의 적응력과 전공 직무와 연계한 핵심 역량 배양을 위해 향상 방안이 고려되어야 할 것이다.

마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향 (The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core)

  • 김근배;김지환;이근우
    • 구강회복응용과학지
    • /
    • 제25권2호
    • /
    • pp.95-107
    • /
    • 2009
  • 본 연구의 목적은 전통적인 소결 방법과 마이크로 웨이브 소결 방법에 의해 제작된 지르코니아 코아의 내부 및 변연 적합도를 알아보는 것이다. 본 실험은 기존의 소결로를 이용하는 $3M^{(R)}$의 Lava(LAV), $Kavo^{(R)}$사의 Everest(EVE), $Cerasys^{(R)}$ CAD/CAM 시스템(CER)과 마이크로웨이브 소결로를 이용하는 Dent. $solution^{(R)}$사의 CAD/CAM 시스템(DEN)에서 시스템별로 12개씩의 코아를 제작하고 실리콘 접착제를 이용하여 금속 다이에 부착시켰다. $Skyscan^{(R)}$ 1076 미세 단층 촬영기를 이용해 각각의 시편을 촬영한 후 재구성하였다. 각 시편에 대해 B-L상, M-D상 절단면 및 치아 장축에 대한 횡단면을 구해내고 각각의 단면에 대해 변연 간격, 축면 간격, 교합면 간격을 측정하였다. 실험에 대한 결과는 다음과 같다. 1. 변연 간격은 EVE가 $36.20{\mu}m$로 가장 작았고, LAV는 $47.67{\mu}m$, DEN는 $52.47{\mu}m$, CER은 $54.63{\mu}m$를 나타내었다. 2. 축면 간격은 EVE가 $63.49{\mu}m$로 가장 큰 값을 나타내었으나 네군간에는 유의차는 없었다. 3. 교합면 간격은 DEN이 $77.06{\mu}m$으로 가장 작은 값을 나타내었으며, EVE와 CER은 $100{\mu}m$를 넘는 값으로 다른 두군과 유의차를 보였다. 본 연구에서 마이크로웨이브 소결을 통해 제작된 CAD/CAM 지르코니아 코아는 임상적으로 허용할 만한 변연 간격 및 축면 간격, 교합면 간격을 보여 주었다.