• 제목/요약/키워드: Dental implant system

검색결과 332건 처리시간 0.027초

Orthodontic treatment of gummy smile by maxillary total intrusion with a midpalatal absolute anchorage system

  • Hong, Ryoon-Ki;Lim, Seung-Min;Heo, Jung-Min;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제43권3호
    • /
    • pp.147-158
    • /
    • 2013
  • This article describes the orthodontic treatment of a 31-year-old Korean female patient with gummy smile and crowding. The patient showed excessive gingival display in both the anterior and posterior areas and a large difference in gingival heights between the anterior and posterior teeth in the maxilla. To correct the gummy smile, we elected to intrude the entire maxillary dentition instead of focusing only on the maxillary anterior teeth. Alignment and leveling were performed, and a midpalatal absolute anchorage system as well as a modified lingual arch was designed to achieve posterosuperior movement of the entire upper dentition. The active treatment period was 18 months. The gummy smile and crowding were corrected, and the results were stable at 21 months post-treatment.

임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구 (A Study on the Retentive Force of Stud Attachments for Implant Overdenture)

  • 송은주;배은빈;최재원;배지현;김지영;이소현
    • 치위생과학회지
    • /
    • 제16권1호
    • /
    • pp.93-100
    • /
    • 2016
  • 이번 연구에서는 두 종류의 어태치먼트 시스템인 Kerator와 O-ring의 다양한 유지력을 가지는 matrix를 사용한 반복적인 착탈 후 평가를 통해 다음과 같은 결론을 얻었다. 초기 유지력은 KP군($62.09{\pm}6.00N$)에서 높았으며, 이어서 KR군($32.83{\pm}4.40N$), KB군($12.69{\pm}3.32N$), OO군($9.55{\pm}1.33N$), 그리고 OR군($9.35{\pm}0.71N$) 순으로 나타났다. 유지력 소실량은 KP군($22.26{\pm}8.02N$)에서 가장 높았으며, KR군($6.23{\pm}3.04N$), OO군($6.03{\pm}1.24N$), OR군($5.81{\pm}0.73N$), 그리고 KB군($0.87{\pm}1.46N$) 순으로 나타났다. 각 군 내의 초기 유지력과 2,500회의 착탈 후의 최종 유지력을 비교하였을 때, KB군을 제외한 모든 군에서 유의한 차이를 보였다(p<0.05). 어태치먼트 표면 마모양상은 Kerator와 O-ring의 matrix에서 눈에 띄는 변형과 손상이 관찰되었다. 각 patrix에서는 유지력 소실에 기여할 만한 변화는 관찰되지 않았다. 결론적으로 어태치먼트의 종류, 재료 그리고 초기 유지력 차이에 따라 마모양상이나 유지력 소실에 차이가 있음을 확 인하였고, 유지력이 보존되는 것처럼 보여도 SEM으로 관찰하였을 때 어태치먼트의 내부가 상당히 변형된 경우가 많았다. 따라서 적절한 유지력을 가진 어태치먼트를 선택하고 각 어태치먼트 시스템 별 적절한 교체시기를 숙지하여 그에따른 사용기간의 준수가 필요할 것으로 생각된다.

20년전 악교정수술을 받았던 환자의 심한 전치부 반대교합의 해결을 위한 임플란트 치료 증례 (Implant treatment on anterior cross-bite of a patient who had orthognathic surgery 20 years ago)

  • 박광만;이성복;이석원
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.245-253
    • /
    • 2019
  • 골격성 3급 부정교합의 악교정 수술로 구강기능과 안모를 개선할 수 있다. 악골부조화가 클수록 술전 교정치료에 의한 치아 이동량이 더욱 커지기 때문에 치주조직에도 큰 변화를 줄 수 있는데, 특히 하악 전치부 치주조직의 파괴가 주로 발생된다. 이 보고는 20년전 골격성 3급 부정교합과 하악전돌로 악교정수술을 받은 후 하악 전치부의 심한 동요 및 반대교합의 해결을 위해 내원한 49세 여성환자의 증례로, Face Hunter, Plane System 및 ARCUS digma II를 이용하여 Top-Down concept의 개인 맞춤형 분석으로 치료계획을 수립하였다. 하악 전치부 발치를 동반한 순측 치조골 성형술과 임플란트 식립 후 즉시임시치관에 의한 즉시부하를 시행하였다. 최종 보철물은 CAD/CAM에 의한 Zirconia 수복물로 제작 후 구강 내에서 나사유지형으로 장착하였다. 6개월이 경과한 현재까지 보철물의 파절과 동요 등은 관찰되지 않았으며, 기능 및 심미적으로 만족스러운 결과를 얻었기에 보고하고자 한다.

Foreign body aspiration and ingestion in dental clinic: a seven-year retrospective study

  • Huh, Jisun;Lee, Namkwon;Kim, Ki-Yeol;Jung, Seoyeon;Cha, Jungyul;Kim, Kee-Deog;Park, Wonse
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권3호
    • /
    • pp.187-195
    • /
    • 2022
  • Background: This retrospective study investigated the incidence rate of accidental foreign body aspiration and ingestion according to patient sex, age, and dental department. This study aimed to verify whether the incidence rate is higher in geriatric than in younger patients and whether it is different among dental departments. Methods: Accidental foreign body aspiration and ingestion cases were collected from electronic health records and the safety report system of Yonsei University Dental Hospital from January 2011 to December 2017. The collected data included patients' age, sex, medical conditions, treatment procedures, and foreign objects that were accidentally aspirated or ingested. The incidence rate was calculated as the number of accidental foreign body aspirations and ingestions relative to the total number of patient visits. Differences depending on the patients' sex, age, and dental department were statistically identified. Results: There were 2 aspiration and 37 ingestion cases during the 7-year analysis period. The male to female incidence ratio was 2.8:1. The incidence rate increased with age and increased rapidly among those aged 80 years or older. Seven of the 37 patients with accidental foreign body ingestion had intellectual disability, Lou Gehrig's disease, dystonia, or oral and maxillofacial cancer. The incidence rate was highest in the Predoctoral Student Clinic and the Department of Prosthodontics. The most frequently swallowed objects were fixed dental prostheses and dental implant components. Conclusion: The incidence rate of accidental foreign body aspiration and ingestion differed according to patient sex, age, and dental department. Dental practitioners must identify high-risk patients and apply various methods to prevent accidental foreign body aspiration and ingestion in dental clinics. Inexperienced practitioners should be particularly careful.

Decontamination methods to restore the biocompatibility of contaminated titanium surfaces

  • Jin, Seong-Ho;Lee, Eun-Mi;Park, Jun-Beom;Kim, Kack-Kyun;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • 제49권3호
    • /
    • pp.193-204
    • /
    • 2019
  • Purpose: The reaction of cells to a titanium implant depends on the surface characteristics of the implant which are affected by decontamination. The aim of this study was to evaluate the cytocompatibility of titanium disks treated with various decontamination methods, using salivary bacterial contamination with dental pellicle formation as an in vitro model. Methods: Sand-blasted and acid-etched (SA) titanium disks were used. Three control groups (pristine SA disks [SA group]; salivary pellicle-coated SA disks [pellicle group]; and biofilm-coated, untreated SA disks [NT group]) were not subjected to any decontamination treatments. Decontamination of the biofilm-coated disks was performed by 14 methods, including ultrasonic instruments, rotating instruments, an air-powder abrasive system, a laser, and chemical agents. MG63 cells were cultured in the presence of the treated disks. Cell proliferation assays were performed on days 2 and 5 of cell culture, and cell morphology was analyzed by immunofluorescence and scanning electron microscopy (SEM). A vascular endothelial growth factor (VEGF) assay was performed on day 5 of culture. Results: The cell proliferation assay revealed that all decontaminated disks, except for the 2 groups treated using a plastic tip, showed significantly less cell proliferation than the SA group. The immunofluorescence and SEM analyses revealed that most groups showed comparable cell density, with the exception of the NT group, in which the cell density was lower and bacterial residue was observed. Furthermore, the cells grown with tetracycline-treated titanium disks showed significantly lower VEGF production than those in the SA group. Conclusions: None of the decontamination methods resulted in cytocompatibility similar to that of pristine SA titanium. However, many methods caused improvement in the biocompatibility of the titanium disks in comparison with the biofilm-coated, untreated titanium disks. This suggests that decontamination is indispensable for the treatment of peri-implantitis, even if the original biocompatibility cannot be restored.

Computer-Assisted Mandibular Reconstruction with Monocortical DCIA Flap; A Case Report

  • Moon, Seong-Yong
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권2호
    • /
    • pp.83-86
    • /
    • 2015
  • Recently, computer-assisted surgery is popular for performing well-planned operations. Computer-aided navigation system is helpful in maxillofacial surgery with real time instrument positioning and clear anatomic identification. Generally, segmental mandibulectomy and reconstruction flap surgery have done by extra-oral approach such as, submandibular approach. This case report describes performing intra-oral segmental mandibulectomy and reconstruction with monocortical deep circumflex iliac artery (DCIA) flap and CT guided implant surgery by using computer-aided surgical guide and navigation for managing ameloblastoma in a 31 years old female patient.

Diagnosis and prediction of periodontally compromised teeth using a deep learning-based convolutional neural network algorithm

  • Lee, Jae-Hong;Kim, Do-hyung;Jeong, Seong-Nyum;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.114-123
    • /
    • 2018
  • Purpose: The aim of the current study was to develop a computer-assisted detection system based on a deep convolutional neural network (CNN) algorithm and to evaluate the potential usefulness and accuracy of this system for the diagnosis and prediction of periodontally compromised teeth (PCT). Methods: Combining pretrained deep CNN architecture and a self-trained network, periapical radiographic images were used to determine the optimal CNN algorithm and weights. The diagnostic and predictive accuracy, sensitivity, specificity, positive predictive value, negative predictive value, receiver operating characteristic (ROC) curve, area under the ROC curve, confusion matrix, and 95% confidence intervals (CIs) were calculated using our deep CNN algorithm, based on a Keras framework in Python. Results: The periapical radiographic dataset was split into training (n=1,044), validation (n=348), and test (n=348) datasets. With the deep learning algorithm, the diagnostic accuracy for PCT was 81.0% for premolars and 76.7% for molars. Using 64 premolars and 64 molars that were clinically diagnosed as severe PCT, the accuracy of predicting extraction was 82.8% (95% CI, 70.1%-91.2%) for premolars and 73.4% (95% CI, 59.9%-84.0%) for molars. Conclusions: We demonstrated that the deep CNN algorithm was useful for assessing the diagnosis and predictability of PCT. Therefore, with further optimization of the PCT dataset and improvements in the algorithm, a computer-aided detection system can be expected to become an effective and efficient method of diagnosing and predicting PCT.

치과용 주조 합금의 방전가공에 따른 표면 성분 변화 (Elemental alteration of the surface of dental casting alloys induced by electro discharge machining)

  • 장용철;이명곤
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

치과 의료의 질 향상(Quality improvement) 경진대회 경향 분석 (Analysis of trends in the dental care quality improvement contests)

  • 황수정;신호성;김진;김명희;안은숙
    • 대한치과의료관리학회지
    • /
    • 제9권1호
    • /
    • pp.38-43
    • /
    • 2021
  • Based on data from the Korean Academy for Dental Administration, which has been conducting the Dental Quality Improvement (QI) Contest since 2010, we aimed to provide basic data for the development of dental quality improvement indicators by analyzing the trends of dental quality improvement activities. A total of 54 articles in the dental QI contest from 2015 to 2021 were used to search for frequently used words and to classify the quality of dental care. The criteria for the quality dimension of dental care were first classified into structure, process, and outcome, and secondary classification was performed into patient safety, timeliness, patient-centeredness, equity, efficiency, effectiveness, and accessibility. The frequently used key terms were satisfaction (five times), efficiency (four times), system (three times), and implant (three times). The activities for process evaluation were high at 62.26%, structural evaluation activities at 35.85%, and outcome evaluation activities at 1.89%. According to the components of dental care quality improvement, the activity performed under efficiency was the highest (33.96%), followed by patient-centeredness (18.87%), effectiveness (16.98%), patient safety (15.09%), accessibility (5.66%), timeliness (1.89%), and the equity (1.89%). QI activities in dental hospitals were mainly activities on improvement in structure and process, as well as activities on efficiency, patient-centeredness, effectiveness, and patient safety.

임플란트 보철의 생역학과 교합 (Biomechanics and Occlusion for Implant-Supported Prosthesis)

  • 구철인;곽종하;정재헌
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.127-144
    • /
    • 2002
  • There is an increasing appreciation of the vital role that biomechanics play in the performance of oral implant. The aim of this article is to provide some basic principles that will allow a clinician to formulate a biomechanically valid treatment plan. However, at this point in the history of oral implantology, the clinician should realize that we do not know enough to provide absolute biomechanical rules that will guarantee success of all implants in all situations. To examine the biomechanical questions, one must begin with an analysis of the distribution of biting forcess to implants. Related topics, such as stress transfer to surrounding tissues and interrelationships between bone biology and mechanical loading are major subjects, deserving a separate discussion. Once rigid fixation, angulation, crestal bone level, contour, and gingival health are achieved, stress beyond physiologic limits is the primary cause of initial bone loss around implants. The restoring dentist has specific responsibilities to reduce overload to the bone-implant interface. These include proper diagnosis, leading to a treatment plan designed with adequate retention and form, and progressive loading to improve the amount and density of bone and further reduce the risk of stress beyond physiologic limits. The major remaining factor is the development of occlusal concept in harmony with the rest of the stomagnetic system.