A TWO-YEAR STUDY OF IMPLANT RETAINED OVERDENTURES IN THE TREATMENT OF TOTALLY EDENTULOUS JAWS

  • Kwon, Ho-Beom;Kim, Eun-Ha;Lee, Seok-Hyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.760-768
    • /
    • 2007
  • Statement of problem. Conventional denture treatment for totally edentulous patients is associated with a variety of functional and psychosocial problems. The placement of implants in the anterior region of the maxilla and mandible and the fabrication of an implant-retained overdenture might solve these problems. Purpose. This study compared the marginal bone loss around the implant and evaluated the implant survival rate and complications in patients treated with overdentures retained by implants for 2 years. Material and methods. Patients who had received implant-retained overdentures using a Dolder bar at Samsung Medical Center from January 1999 to June 2005 and had participated in the annual recall programs for two years were selected for this study. A total of 18 patients and 56 $Br{\aa}ne-mark\;system^{(R)}$ implants were used, and their data were reviewed. Evaluations of the survival rate, bone quality, marginal bone loss, and complications were performed. The data on the Dolder bar length and clip length were measured. The change in marginal bone loss and the correlation between the marginal bone loss and bar length, clip length, or bone quality were investigated. Results. Implants placed in this study showed a 100% survival rate. The average annual bone loss was 1.12mm in the first year and 0.27mm in the second year in the maxilla, and 0.58mm in the first year and 0.22mm in the second year in the mandible. The marginal bone loss in the maxilla showed no significant association with those in the mandible. (P>.05). There was no significant difference in marginal bone loss around implants between the first and second year. (P>.05) There was no statistically significant relationship (P>.05) between the marginal bone loss and bone quality, clip length, or Dolder bar length. The Dolder bar length showed a high correlation with the clip length. (P<.05) Various complications were noted. Conclusion. These results confirmed the favorable outcome for patients treated with implant-retained overdentures.

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

  • Kim, Hak-Kyun;Lee, Eun-Young;Kim, Jae-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.317-321
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. Materials and Methods: The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements were performed. Radiographs were taken before the first surgery, immediately after the first and second surgeries, immediately and six months after the final prosthesis installation, and every year after that. Bone loss was evaluated by the method suggested by Romanos and Nentwig. Results: A total of 176 implant placements were performed - 122 in men and 54 in women. These patients have been followed-up for an average of 4.9 years. In terms of prosthetic appliances, there were 156 bridges and 20 single prostheses. Nine implants installed in the maxillary molar area, three in the mandibular molar area and two in the maxillary premolar area were included in group M, with bone loss less than 2 mm at the crestal aspect of the implant. Of these, eight implants were single prostheses. In all, six implants failed - four in the mandible and two in the maxilla. All of these failures occurred in single-implant cases. The implant survival rate was 98.1% on the maxilla and 94.3% on the mandible, with an overall survival of 96.6%. Conclusion: Within the limitations of this study, implants with the SLA surface have a very superior survival rate in relatively poor bone environments such as the maxilla.

Influence of the implant-abutment connection design and diameter on the screw joint stability

  • Shin, Hyon-Mo;Huh, Jung-Bo;Yun, Mi-Jeong;Jeon, Young-Chan;Chang, Brian Myung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.126-132
    • /
    • 2014
  • PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (${\alpha}$=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

A case report of a surgical guide fabricated via intraoral scanning-based implant planning and wax-based rapid prototyping (구강스캐너를 이용한 임플란트 수술 계획 및 왁스 기반 쾌속조형법으로 제작한 수술용 가이드 증례)

  • Shin, Jong-Hoon;Park, Eun-Jin;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.244-249
    • /
    • 2015
  • With the recent progress of digital technology, the computer guided surgery utilizing a guide template in the placement of implant has been actively performed, and the method employing the intraoral scanner at the implant prosthesis introduced. Fabrication method of the guide template can be largely classified into design-related rapid prototyping (RP) system and vector milling system, and each of the method has its own weakness in the clinical application despite of excellent accuracy. Thus, in this case study, a working model was fabricated by the wax RP technology using images acquired by CBCT and an intraoral scanner, and the metal bushing was picked up with orthodontic resin cast upon the wax model. Using this method, a surgical guide template was fabricated and used in surgery. From this, we could obtain a satisfactory outcome clinically in the implant placement and the fabrication of the final prostheses and thus report this case herein.

Oral rehabilitation using implant supported fixed dental prostheses in a growing patient who underwent mandibulectomy and fibular free flap (하악골 절제술 및 비골유리피판을 시행한 성장기 환자에서 임플란트를 이용한 고정성 보철 수복 증례)

  • Lee, Hag-Young;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.268-274
    • /
    • 2020
  • Functional and esthetic recovery through reconstruction of the oral and maxillofacial system is important for patients who underwent mandibulectomy due to lesions such as oral cancer. The fibula free flap, which is frequently used in the reconstruction of the mandible, is easy to prosthetic restoration with implant placement. However, patients with growing periods have difficulty in treatment with implants when the size of the fibula is small and residual growth remains. This case is an 11-year-old female patient who underwent mandibulectomy due to osteosarcoma and reconstruction of the mandible using a fibular free flap. Functional and esthetic recovery were obtained through prosthetic restoration using implant-supported fixed prostheses. Implantation site, number of implants, and type of prostheses were considered. Implant-supported fixed prostheses were delivered at 13 years old, and after an additional 1 year observation, stable results were obtained. However, observing changes in the maxillofacial system through further examinations is necessary.

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient (상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례)

  • Hong, Mun Gi;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Treatment options for edentulous patients are complete denture and implant prosthesis. A two implant-retained overdenture can be considered the first treatment in the edentulous mandible, but there is no clear consensus of treatment for edentulous maxilla. Implant-retention/support overdenture shows better retention and stability than complete denture and is less expensive and more esthetic than implant-supported fixed prosthesis. CM $LOC^{(R)}$ $Pekkton^{(R)}$ attachment is a solitary type attachment and evaluated to have excellent abrasion resistance and retention with a female part made of poly-ether-ketone-ketone. Meanwhile, SR Ivocap system is injection molding method and discussed to show few changes in the vertical dimension of denture and have excellent fracture resistance. In this case, we restored maxillary arch with a four implant-retained overdenture using CM $LOC^{(R)}$ $Pekkton^{(R)}$ and SR Ivocap system, and mandibular arch with a removable partial denture. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Oral rehabilitation with magnetic overdentures for an old patient with complex systemic diseases (복합적인 전신질환이 있는 안면마비 환자의 양악 자성 피개의치 수복 증례)

  • Ko, Eunjin;Ahn, Sujin;Lee, Sukwon;Park, Sujung;Lee, Richard Sungbok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.150-156
    • /
    • 2015
  • As dental implant treatment becomes popular for both partial and complete edentulous patients, old people with complex systemic diseases also tend to prefer implant-assisted-overdenture or implant-supported-fixed prostheses to conventional complete denture. In this case, 77-year-old female who was on medication for hypertension and osteoporosis and paralyzed on right side due to stroke visited for implant-assisted-overdenture on lower jaw. After oral and radiographic examination, root-assisted magnet overdenture on upper jaw and implant-assisted magnet overdenture on lower jaw are planned. Consequently, overdentures using self-adjusting magnetic attachment(SA) system on both jaws resulted in recovering satisfying function and retention, which is enable to insert and remove with only one hand.

A STUDY ON THE BONE FORMATION OF GRAFT MATERIAL CONTAINING DEMINERALIZED BONE MATRIX WITH A SIMULTANEOUS INSTALLATION OF IMPLANT (임프란트 식립시 이식된 탈회골기질을 함유한 이식재의 골형성에 대한 연구)

  • Kim, Yeo-Gab;Yoon, Byung-Wook;Ryu, Dong-Mok;Lee, Baek-Soo;Oh, Jung-Hwan;Kwon, Yong-Dae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.6
    • /
    • pp.481-491
    • /
    • 2005
  • Purpose: The aim of the present study is to evaluate the effect of autogenous bone and allograft material coverd with a bioresorbable membrane on bone regeneration after a simultaneous installation of implant. Materials and methods: Twelve healthy rabbits, weighing about $3{\sim}4$ kg, were used in this experiment. Following impalnt(with 3.25 mm diameter and 8 mm length) site preparation by surgical protocol of $Oraltronics^{(R)}$, artificial bony defect, 5mm sized in height and depth, was created on femoral condyle using trephine drill(with 5 mm diameter and 5 mm length). Then implant was inserted. In the experimental group A, the bony defect was filled with autogenous particulated bone and coverd with $Lyoplant^{(R)}$ resorbable membrane. In the experimental group B, the bony defect was filled with allograft material(Orthoblast $II^{(R)}$) containing demineralized bone matrix and covered with $Lyoplant^{(R)}$. In the control group, without any graft materials, the bony defect was covered with $Lyoplant^{(R)}$. The experimental group A and B were divided into each 9 cases and control group into 3 cases. The experimental animals were sacrificed at 3, 6 and 8 weeks after surgery and block specimens were obtained. With histologic and histomorphometric analysis, we observed the histologic changes of the cells and bone formation after H-E staining and then, measured BIC and bone density with KAPPA Image $Base^{(R)}$ system. Results: As a result of this experiment, bone formation and active remodeling process were examined in all experimental groups and the control. But, the ability of bone formation of the experimental group A was somewhat better than any other groups. Especially bone to-implant contact fraction ranged from 12.7% to 43.45% in the autogenous bone group and from 9.02% to 29.83% in DBM group, at 3 and 8 weeks. But, bone density ranged from 15.67% to 23.17% in the autogenous bone group and from 25.95% to 46.06% in DBM group at 3 and 6 weeks, respectively. Although the bone density of DBM group was better than that of autogenous bone group at 3 and 6weeks, the latter was better than the former at 8 weeks, 54.3% and 45.1%, respectively. Therefore these results showed that DBM enhanced the density of newly formed bone at least initially.

Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants (임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향)

  • Yun, Bo-Hyeok;Shin, Hyon-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.