• Title/Summary/Keyword: Dental implant fixture

검색결과 235건 처리시간 0.027초

Influence of the connection design and titanium grades of the implant complex on resistance under static loading

  • Park, Su-Jung;Lee, Suk-Won;Leesungbok, Richard;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.388-395
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the resistance to deformation under static overloading by measuring yield and fracture strength, and to analyze the failure characteristics of implant assemblies made of different titanium grades and connections. MATERIALS AND METHODS. Six groups of implant assemblies were fabricated according to ISO 14801 (n=10). These consisted of the combinations of 3 platform connections (external, internal, and morse tapered) and 2 materials (titanium grade 2 and titanium grade 4). Yield strength and fracture strength were evaluated with a computer-controlled Universal Testing Machine, and failed implant assemblies were classified and analyzed by optical microscopy. The data were analyzed using the One-way analysis of variance (ANOVA) and Student's t-test with the level of significance at P=.05. RESULTS. The group $IT4_S$ had the significantly highest values and group IT2 the lowest, for both yield strength and fracture strength. Groups $IT4_N$ and ET4 had similar yield and fracture strengths despite having different connection designs. Group MT2 and group IT2 had significant differences in yield and fracture strength although they were made by the same material as titanium grade 2. The implant system of the similar fixture-abutment interfaces and the same materials showed the similar characteristics of deformation. CONCLUSION. A longer internal connection and titanium grade 4 of the implant system is advantageous for static overloading condition. However, it is not only the connection design that affects the stability. The strength of the titanium grade as material is also important since it affects the implant stability. When using the implant system made of titanium grade 2, a larger diameter fixture should be selected in order to provide enough strength to withstand overloading.

임플랜트의 체결방식에 따른 초기조임력에 의한 응력분포 및 전하중에 관한 연구 (THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND PRELOAD OF DIFFERENT CONNECTION TYPES IMPLANT WITH INITIAL CLAMPING)

  • 이범현;전흥재;이수홍;한종현
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.197-206
    • /
    • 2006
  • Statement of problem: One of common problems associated with single teeth dental implant prosthetic is the loosening of screws that retain the implants. Purpose: The maintenance of screw joint stability is considered a function of the preload achieved in the screw when the suggested initial tightening torque is applied. The purpose of this study was to investigate acquired preload after initial clamping torque for estimating screw joint stability. Material and methods: A comparative study on the effect of initial clamping of two types of implant systems with different connections was conducted Three dimensional non-linear finite element analysis is adopted to compare the characteristics of screw preloads and stress distributions between two different types of implant systems composed with abutment, screw, and fixture under the same loading and boundary conditions. Results: 1. When the initial clamping torque of 32Ncm was applied to the implant systems, all types of implants generated the maximum effective stress at the first helix region of screw. 2. Morse taper connection types of implants generate lower stress distributions compared to those by butt joint connection types or implants due to large contact surface between abutment and fixture. 3. The internal types of implant systems with friction grip type implant systems have higher resistance to screw loosening than that of the external types of implant systems since the internal types of implant systems generated larger preload than that generated by the external types for the same tightening moments.

Comparison of implant component fractures in external and internal type: A 12-year retrospective study

  • Yi, Yuseung;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Shin-Jae;Heo, Seong-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.155-162
    • /
    • 2018
  • PURPOSE. The aim of this study was to compare the fracture of implant component behavior of external and internal type of implants to suggest directions for successful implant treatment. MATERIALS AND METHODS. Data were collected from the clinical records of all patients who received WARANTEC implants at Seoul National University Dental Hospital from February 2002 to January 2014 for 12 years. Total number of implants was 1,289 and an average of 3.2 implants was installed per patient. Information about abutment connection type, implant locations, platform sizes was collected with presence of implant component fractures and their managements. SPSS statistics software (version 24.0, IBM) was used for the statistical analysis. RESULTS. Overall fracture was significantly more frequent in internal type. The most frequently fractured component was abutment in internal type implants, and screw fracture occurred most frequently in external type. Analyzing by fractured components, screw fracture was the most frequent in the maxillary anterior region and the most abutment fracture occurred in the maxillary posterior region and screw fractures occurred more frequently in NP (narrow platform) and abutment fractures occurred more frequently in RP (regular platform). CONCLUSION. In external type, screw fracture occurred most frequently, especially in the maxillary anterior region, and in internal type, abutment fracture occurred frequently in the posterior region. placement of an external type implant rather than an internal type is recommended for the posterior region where abutment fractures frequently occur.

Steri-Oss 임플랜트의 임상 결과에 관한 연구 (A STUDY OF CLINICAL RESULTS ON STERI-OSS ENDOSSEOUS IMPLANTS)

  • 민영규;권혁신;정재헌
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.258-272
    • /
    • 1998
  • This investigation evaluated patients who received Steri-Oss implants from the Dental Hospital of Chosun University during the period from March 1989 to August 1997. 346 fixtures of 127 patients were included in this study. The results were as follows ; 1.The follow-up period was defined as the period between the surgical placement of the implants and the last follow-up examination. The mean follow-up period was $2.17{\pm}1.21$ years. 2.The period between fixture installation and second surgery was $0.71{\pm}0.44$ years in the maxilla and $0.46{\pm}0.21$ years in the mandible. 3.The number of fixtures which were installed in the upper jaw(112) was less than that in the lower jaw(234) and in the posterior region(260) was more than in the anterior region(86). 4.The length of fixture which was most frequently used was 12 mm and least was 8mm. Screw implants were installed more than cylindrical implants. 3.8mm implant was the most common implans, followed by 4.5mm and 3.25mm. 5.The number of augmentation cases was more than that of non-augmentation cases and the rate of augmentation cases in the maxilla was more than that in the mandible. 6.Implant restorations for partial edentulos patients(94cases) were more than single- tooth implant restorations(33cases) or implant restorations for complete edentulos patients(10cases). 7.Free-standing prostheses for partially edentulous patients were more commom than any other type of connection between implants and natural teeth. 8.Plaque Index($0.95{\pm}0.74$) and Gingival Index($0.31{\pm}0.52$) were very similar around the natural teeth and reflected an acceptable level of plaque and gingivitis control. Mean value for keratinized mucosa index($1.93{\pm}1.20$) remained fairly constant around level 2(1-2 mm keratinized epithelium). 9.Patients were generally satisfied with implant in terms of comfort, function, speech and esthetics. 10.There was not a statistically significant differences in overall survial rate between implants placed in the maxilla (91.5%) and those placed in the mandible (93.8%). Fourteen implants lost before the prosthetic rehabilitation and eleven implants lost following variable periods in function after the prosthetic phase of the treatment. 11.Cause of implant failures was exfoliation or removal of fixture due to non-osseointegration before the prosthetic rehabilitation or due to fracture of fixture, masticatory pain after the prosthetic rehabilitation. 12.The survival rate of Steri-Oss implants using the Kaplan-Meier statistical analysis was 93.8% at 2 year and 86.6% at 5 year, In all cases, implant losses occured predominantly in the healing period. There was a steep decline in the rate of implant loss after the first year. 13.The survival rate of Steri-Oss implants in the anterior region was 94.8% at 2 year and 94.8% at 5 year and that in the posterior region was 92.8% at 2 year and 75.9% at 5 year. In conclusion, this study revealed a number of parameters and guidelines for achieving an optimal success rate in osseointegration.

  • PDF

임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향 (INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY)

  • 오갑용;박성화;김석규
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

임플란트 구성요소의 파절면에 관한 주사전자현미경적 연구 - Part I: 임플란트 고정체 (Fracture Analysis of Implant Components using Scanning Electron Microscope - Part I : Implant Fixture)

  • 임광길;김대곤;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.297-309
    • /
    • 2010
  • 보철물의 실패는 파절로 인해 다수 발생하게 되지만 파절 발생시 그 원인을 파악하는 것은 어렵다. 보철물의 실패를 예방하고 예후를 예측하기 위해 보철물의 원인을 분석하는 것이 중요하며, 원인을 밝히기 위해 파절면 분석을 시행하게 된다. 파절면 분석은 파절면 뿐 아니라 주위 환경(응력 상황)에 대한 분석이 동반되며, 이를 이용하여 균열 진행, 파절 양상, 파절 원인 등을 파악하게 된다. 이 연구의 목적은 임상적으로 기능 후 파절된 임플란트 고정체의 파절면 분석을 시행하여 파절 기전 및 파절 원인(하중 양상)을 밝히는 것이다. 파절된 임플란트 고정체는 3년간 강릉-원주 대학교에 임플란트 고정체의 파절을 주소로 내원한 환자를 대상으로 수집하였다. 먼저 임상 및 방사선 사진 분석을 하였으며, 시편 세척 과정을 거쳐 주사 전자 현미경을 이용한 파절면 분석을 시행하였다. 임플란트 파절면 분석 시 피로 줄무늬, 벽개 파절 등의 파절 지표를 통해 피로 파절로 인해 파절이 발생되었음을 확인할 수 있었다.

외측연결형 임플란트 고정체의 경부 디자인이 임플란트 주위조직에 미치는 영향에 대한 전향적 예비 임상연구 (Effect of neck design on peri-implant tissue responses in external connection type implant : a prospective pilot clinical study)

  • 배은빈;이소현;전영찬;강은숙;박상례;이진주;허중보
    • 대한치과의사협회지
    • /
    • 제55권11호
    • /
    • pp.766-776
    • /
    • 2017
  • This clinical study was conducted to evaluate the clinical effects of a concave neck of external connection type implant fixture designed for platform switching on the peri-implant tissue responses. Two types of implants with different neck designs were implanted in 20 patients. For the experimental group, the bioseal(BS) implant fixtures with 's' shaped concave profile on the neck were used, and non-bioseal(NBS) implant fixtures with a straight profile on the neck were used as control(Total of 40 implants, NBS: n = 19, BS: n=21). During the one-year period after implant placement, implant survival rate, marginal bone resorption, bleeding, plaque, and complications were evaluated. The survival rate of NBS and BS group was 94.74% and 90.48%, respectively. There was no significant difference on marginal bone resorption, bleeding and plaque between the two groups (P>.05). Within the limits of the present study, implants with a concave neck design showed similar clinical results to implants with a straight neck design on the peri-implant tissue responses. Longitudinal clinical studies are necessary to confirm more effective clinical results.

  • PDF

COMPARATIVE ACCURACY OF THE SPLINTED AND UNSPLINTED IMPRESSION METHODS FOR INTERNAL CONNECTION

  • Choi, Jung-Han;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jin
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.352-362
    • /
    • 2005
  • Statement of problem. Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems. Purpose. The purpose of this study was to compare the accuracy of two fixture-level impression techniques in two conditions (parallel and divergent) and to assess the effect of tightening sequences and forces on stresses generated on superstructures in internal connection implant system (Astra Tech). Material and methods. Two metal master frameworks made from two abutments (Cast-to Abutment ST) each and a corresponding, passively fitting, dental stone master cast with four fixture replicas (Fixture Replica ST) were fabricated. Ten dental stone casts for each impression techniques (direct unsplinted & splinted technique) were made with vinyl polysiloxane impressions from the master cast. Strain gauges for each framework were fixed midway between abutments to measure the degree of framework deformation on each stone cast. Pairs of strain gauges placed opposite each other constituted one channel (half Wheatstone bridge) to read deformation in four directions (superior, inferior, anterior, and posterior). Deformation data were analyzed using one-way ANOVA and the Tukey test at the .01 level of significance. And the effect of tightening sequences (right-to-left and left-to-right) and forces (10 Ncm and 20 Ncm) were assessed with ten stone casts made from parallel condition by the splinted technique. Deformation data were analyzed using paired t-test at the .01 level of significance. Conclusions. Within the limitations of this study, the following conclusions could be drawn. 1. Frameworks bent toward the inferior side on all casts made by both direct unsplinted and splinted impression techniques in both parallel and divergent conditions. 2. There was no statistically significant difference of accuracy between the direct unsplinted and splinted impression techniques in both parallel and divergent conditions (P>.01). 3. There was no statistically significant difference of stress according to screw tightening sequences in casts made by the splinted impression technique in parallel condition (P>.01). 4. Greater tightening force resulted in greater stress in casts made by the splinted impression technique in parallel condition (P<.01).

임플란트주위염의 삭제형 골수술 후 골재생 증례보고: 6년 추적관찰 (Unusual bone regeneration following resective surgery and decontamination of peri-implantitis: a 6-year follow-up)

  • 김현주;이주연
    • 구강회복응용과학지
    • /
    • 제38권3호
    • /
    • pp.171-177
    • /
    • 2022
  • 임플란트주위염은 임플란트의 주변 치조골의 상실을 동반한 치주조직의 염증성 병소이다. 임플란트주위염의 치료 목표는 자연치에서 발생되는 치주염의 치료와 유사하게, 염증을 해결하여 임플란트 주위 치주조직의 건강을 회복시키는 것이다. 치료 방법으로는 염증의 진행 정도에 따라 구강위생교육과 국소적 또는 전신적 방부제(antiseptics)와 항생제 처치를 동반한 지대주(fixture)의 mechanical cleansing, 삭제형 또는 재생형 골수술 등이 제안되고 있다. 본 연구에서, 임플란트 주위염의 표면처리(decontamination)와 삭제형골수술 이후, 특이한 골재생 증례의 6년 추적관찰 결과를 보고하고자 한다.

Vertical Augmentation of Maxillary Posterior Alveolar Ridge Using Allogenic Block Bone Graft and Simultaneous Maxillary Sinus Graft

  • Lee, Eun-Young;Kim, Eun-Suk;Kim, Kyoung-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권5호
    • /
    • pp.224-229
    • /
    • 2014
  • The maxillary posterior area is the most challenging site for the dental implant. Although the sinus graft is a predictable and successful technique for rehabilitation of atrophic and pneumatized posterior maxilla, when there is severe destruction of alveolar bone, a very long crown length remains challenging after successful dental implants installation with sinus graft. We performed vertical augmentation of the maxillary posterior alveolar ridge using the allogenic block bone graft with a simultaneous sinus graft using allogenic and heterogenic bone chips. After about six months, we installed the dental implant. After this procedure, we achieved a more favorable crown-implant fixture ratio and better results clinically and biomechanically. This is a preliminary report of vertical augmentation of maxillary posterior alveolar ridge using allogenic block bone graft and simultaneous maxillary sinus graft. Further research requires longer observation and more patients.