• 제목/요약/키워드: Dental handpiece

검색결과 57건 처리시간 0.019초

치과용 고속 에어터빈 핸드피스의 공급관로 분석 및 성능평가 (Supply Route Analysis and Performance Evaluation of Dental High-Speed Air Turbine Handpiece)

  • 한명철;김정관;최명욱
    • 한국정밀공학회지
    • /
    • 제28권1호
    • /
    • pp.80-88
    • /
    • 2011
  • The dental high-speed air turbine handpiece is one of the most popular devices that have been widely used as the main means of cutting tooth structure and restorative material in dentistry. In consideration of usage and marketability of the dental handpiece, it is obviously worthy of investigating it. The goal of this paper is to establish the relationship between the air turbine speed and the supply route inside the handpiece. To do this, the Computational Fluid Dynamics(CFD) tool, Fine$^{TM}$/Turbo is used and the optimal supply route position is suggested from the simulation results. In addition, as an attempt for domestic product, the reverse engineering process of a high speed dental handpiece by 3D X-Ray CT equipment and wire cutting is presented for the Mark II model in NSK. In doing so, the 3D modeling of the handpiece parts is carried out with CATIA V5, and the interference between parts is examined. Finally, the result of performance test for the prototype produced in this research is presented.

Effect of repeated use of an implant handpiece on an output torque: An in-vitro study

  • Son, KeunBaDa;Son, Young-Tak;Kim, Ji-Young;Lee, Jae-Mok;Yu, Won-Jae;Kim, Jin-Wook;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.136-143
    • /
    • 2021
  • Purpose. This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque. Materials and Methods. Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150). For statistical analysis, the difference between the groups was analyzed using the Mann-Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05). Results. NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (P<.001). The type of implant handpiece and repeated use influenced the output torque (P<.001). Conclusion. There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.

치과 핸드피스용 감염방지구의 임상적 효용성 (Clinical Efficacy of Latex Cover for Dental Handpiece)

  • 이기호;백동헌
    • Journal of Oral Medicine and Pain
    • /
    • 제34권3호
    • /
    • pp.237-245
    • /
    • 2009
  • 본 연구의 목적은 치과 치료 시 라텍스 감염방지구가 핸드피스의 오염을 방지하고 고압 멸 균 소독과 같은 전통적 소독을 대신하는 방법이 될 수 있는 지 조사하는 것이다. 구강 내 상주균 대신 사용한 균주는 E. fecaelis (ATCC 29212) 이며 구강을 대신하는 2cm 의 정방형 cavity 가 형성된 실험용 bowl 을 제작하였다. 라텍스 재질의 덮개는 $Orokeeper^{(R)}$ (Orobiotech Co., Korea)를 사용하였으며 모든 실험 핸드피스는 고압멸균소독기에서 멸균 후 사용하였다. 4가지 실험으로 이루어 졌다 : 핸드 피스의 다양한 부위에 대한 세균 오염 평가, 알코올 소독솜으로 핸드피스의 전면 및 헤드부 에 소독 후 소독시간에 따른 세균오염 평가, 핸드피스 사용 후 air-water spray 시간에 따른 핸드 피스의 전면 및 헤드부에 대한 세균오염 평가, 라텍스 덮개의 반복 사용에 따른 핸드피스의 오염도에 대한 평가 등이다. 실험결과 라텍스 감염방지구로 덮여진 부분과 비교할 때 덮여져 있지 않은 부위의 오염 도가 매우 심하였다. 그러나 핸드피스 사용 후 15초간 알코올 솜으로 닦아내거나, 15초간 기수분사를 한 후에는 소독 수준 까지 균이 감소하였다. 결론적으로 오로 키퍼 같은 라텍스 감염방지구는 15초간의 알코올 세척 또는 사용 후 15초 기수분사와 함께 사용하면 멸균 소독을 할 수 없는 어려운 상황에서 교차감염 방지를 목적으로 사용이 가능하리라 사료된다.

Air-jet기능을 장착한 멀티형 복합유닛 핸드피스의 사용 만족도 조사 (A study on the usage satisfaction of multi-type handpieces with equipped air-jet function)

  • 김임선;최병환
    • 대한치과기공학회지
    • /
    • 제37권3호
    • /
    • pp.169-178
    • /
    • 2015
  • Purpose: This study was to investigate usage satisfaction of multi type handpiece with equipped air-jet function Methods: The subjects of this study through the survey was conducted for fifty-nine dental technicians in Daegu and Gyeongsangbukdo from the May 7 to 19, after the June 23 to July 4 2014. The survey was about the function and quality through user testing environment by cutting zirconia specimens using appliance for zirconia. The collected date was analyzed by the statistical program SPSS Win Ver 19.0 for the satisfaction of handpiece and control system. To test for significance on each item, p<0.05 had been decided a standard. General characteristics and relationship between the handpiece and control system was performed correlation analysis. Results: The results of this study is as follows. 35 dental technicians had 1~2 years career in zirconia part as the highest 59.3%, 95% of subjects expected that the prospects for the zirconia material have bright prospects. The satisfaction of multi type handpiece and control system design and function showed a significant difference. Subjects satisfied with the design and function of the multi type showed negative correlation with those of Standard. The satisfaction of multi type handpiece showed 3.37 points of air jet, 3.05 points of noise level, 2.69 points of water flow rate, and 1.98 points of cruise function. Sample differences in all parameters showed a statistically higher difference. Conclusion: High-speed cutting mechanism of multi-type is recommended working with zirconia materials and the multi-type unit combined handpiece motor, air-turbine and air-gun will be expected the increase of user due to the high satisfaction of air jet.

터빈 로터 반사각에 따른 의료용 에어터빈 핸드피스의 성능에 관한 수치 해석 (Numerical Analysis on Performance of Dental Air Turbine Handpiece for Various Reflection Angles of Turbine Rotor)

  • 이정호;이상도;김귀순
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.29-32
    • /
    • 2008
  • Dental high-speed air turbine handpieces have been used as a dental cutting tool in clinical dentistry for over 50 years, yet little study has been reported on their flow and performance analysis. Therefore it is necessary to investigate turbine for the performance improvements of an air turbine handpiece. This paper presents pressure on turbine rotor and flow analysis in air turbine handpiece using CFD (computational fluid dynamics). Characteristics on each flow and pressure for four various reflection angles of turbine rotor are presented, and then performance change is analyzed about air turbine handpieces by CFD results.

  • PDF

Design of Air Turbine and Air Bearing for Dental Handpiece

  • Hwang, Pyung;Park, Sang-Shin;Sohn, Jeong-L.;Kwon, Seong-In;Kim, Do-Hyung;Kim, Woo-Seok
    • Tribology and Lubricants
    • /
    • 제23권5호
    • /
    • pp.240-247
    • /
    • 2007
  • The design process of the dental handpiece is described. The parameters of the high speed air turbine are estimated. The effect of supply hole on the stiffuess and damping of the air bearing for handpiece is studied numerically. The Reynolds equation is solved by using the divergence formulation and the perturbation method. The test rig is built and the test procedure is developed for the turbine rotational speed measurement by using Fourier transform of noise generated by the turbine during steady operation.

대구지역 치과 의료기관 종사자의 B형간염 예방접종 및 감염관리 실태 (Investigation about the Actual Prevention of Infection and Vaccination against B-type Hepatitis among Dental Workers in Daegu)

  • 은정화;배지영
    • 한국치위생학회지
    • /
    • 제5권2호
    • /
    • pp.219-233
    • /
    • 2005
  • This study was conducted on 185 workers at 73 dental clinics and university hospitals in Daegu to investigate the actual prevention of infection and vaccination against B-type hepatitis among dental workers. 1. According to the result of medical examination, only 35 out of 144 (24%) dental clinic workers had periodic health examination while 7 out of 9 (78%) university hospital workers did. 2. In a survey on vaccination against B-type hepatitis, 52 workers aged 29 or younger (96.3%), 38 dental hygienists (51.9%) and 44 dental workers at dental clinics (81.5%) have not had any vaccination against B-type hepatitis. The rest appeared to have had vaccination or be aware that they had antibody against B-type hepatitis without having to have any vaccination. 3. According to the result of a survey on the existence of antibody by job, 42 (56%) of dental hygienists, 15 (20%) of assistant nurses, 12 (16%) of medical assistants and 6 (8%) of dental technicians did not know whether or not they had antibody. This suggests that all types of dental workers except dental hygienists have low awareness of whether or not they have antibody. 4. In a survey on the relation between general characteristics of subjects and the sterilization of dental equipment, alcohol disinfection of high speed handpiece and low speed handpiece was most common among dental workers aged 29 or younger, and all of those aged over 40 used autoclave. By position, alcohol disinfection was used most commonly for high-speed handpiece. antiseptic solution deposition for disposable suction lips, and autoclaving for impression. By workplace, dental workers at university hospitals used autoc1aving most frequently for high/low speed handpiece while those at dental hospitals and dental clinics used alcohol disinfection most frequently and even some respondents replied that they did not disinfect. For metal cups, workers at dental clinics and dental hospitals did not use any sterilizing method while those at university hospitals used autoclaving. For disposable suction tips, workers at dental clinics used antiseptic solution deposition and those at dental hospitals used alcohol disinfection but some respondents replied that they did not disinfect. For metal suctions and impression trays, autoclaving was most common in all workplaces but some dental clinics replied that they did not disinfect impression trays. According to work experience, alcohol disinfection was most common for high/low speed handpiece. For disposable suction tips, dental workers with 3 years' or shorter work experience, those with 3~6 years' experience and those with 9~12 years' experience used antiseptic solution deposition most commonly, and many of those with 6~9 years replied that they did not disinfect. The results of this study stated above suggest that systematic education is necessary for all dental workers for enhancing th eir awareness of B-type hepatitis and the prevention of infection. Moreover, dental workers are required to make efforts to prevent infection with B-type hepatitis voluntarily and actively.

  • PDF

Extensive Bilateral Subcutaneous Emphysema after Dental Treatment: Two Case Reports

  • Gyu-Beom Kwon;Chul-Hwan Kim ;Hae-Seo Park
    • Journal of Korean Dental Science
    • /
    • 제16권1호
    • /
    • pp.80-86
    • /
    • 2023
  • We report two rare cases of extensive bilateral subcutaneous emphysema that occurred during ordinary dental procedures. An air-driven high-speed handpiece, routinely used in dental procedures may cause subcutaneous emphysema when high pressure air is introduced into the loose connective tissues below the dermal layer. The first case occurred with surgical extraction of the lower third molar. The air introduced into the fascial spaces near the surgical field spread to the contralateral spaces, as well as the neck and chest areas. The second case also showed extensive bilateral subcutaneous emphysema caused by the introduction of compressed air from the handpiece during crown preparation without any invasive procedure. Cases where the emphysema extends beyond the treatment site to involve the contralateral cervicofacial areas have been rarely reported. Predicting the occurrence of subcutaneous emphysema is difficult, so it is important to exercise caution during routine dental treatment. If significant bilateral cervicofacial swelling is suspected to be due to subcutaneous emphysema, prompt diagnosis with securing the patient's airway will be necessary.

터빈 블레이드 형상에 따른 의료용 에어터빈 핸드피스의 성능 특성에 관한 수치적 연구 (Numerical Study on the Effect of Turbine Blade Shape on Performance Characteristics of a Dental Air Turbine Handpiece)

  • 이정호;김귀순
    • 한국추진공학회지
    • /
    • 제13권1호
    • /
    • pp.34-42
    • /
    • 2009
  • 의료용 고속 에어터빈 핸드피스는 치아 절삭 도구로써 지난 50년 동안 치의학분야에서 사용되어왔으나, 그것에 대한 성능 연구가 많이 없었다. 그래서 수치해석을 이용하여 핸드피스 터빈 형상의 성능 특성을 본 논문에서 연구하였다. 정상상태 방법 중 하나인 프로즌 로터 방식을 이용하여 터빈 블레이드의 위치에 따라 5가지의 경우에서 계산하였다. 형상과 반사각에 따른 터빈 블레이드의 특성을 분석하였다. 계산 결과에 따르면, 터빈 블레이드의 반사각이 증가할 때 토크가 증가하였다.

터빈 형상에 따른 의료용 에어터빈 핸드피스의 유동분석 및 성능에 관한 수치적 연구 (Numerical Study on the Effect of Turbine Shape on the Flow Characteristics and Performance of Dental Air Turbine Handpiece)

  • 이정호;이상도;김귀순
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.5-8
    • /
    • 2008
  • 본 연구는 지난 연구에 이어서 핸드피스 터빈 형상에 따른 유동특성 및 성능을 수치해석을 이용하여 연구하였다. 정상상태 방법 중 하나인 프로즌 로터 방식을 이용하여 노즐 중심선과 터빈 로터사이의 여러 각도에 따라 계산하였다. 평평한 모양, 오목한 형상, 갈매기 모양 등 3가지 터빈 로터 형상의 특성을 분석하였다. 추가적으로, 가장 성능이 좋은 로터 모양에 있어서 다른 반사각으로 계산을 하였다.

  • PDF