• 제목/요약/키워드: Dental cast analysis

검색결과 80건 처리시간 0.026초

치과 보철물 제작시 사용되는 Sprue의 재료 및 형태가 비귀금속 합금의 주조성에 미치는 영향에 관한 연구 (A Study on the Castability of Base Metal Alloys Which Sprue Shape and materials used in the Production of Dantal Prosdontics)

  • 최운재;신무학;김연수
    • 대한치과기공학회지
    • /
    • 제21권1호
    • /
    • pp.87-96
    • /
    • 1999
  • In order to examine the influence of sprue(used to make crown supplements) on casting, 3 kinds of sprue materials(wax, wood, plastic) and 3 types of sprue(round, square, triangle) were made and buried and cast, then the comparison and analysis of casting characters among sprue materials and among sprue type show the following results : 1. The comparison of casting characters in accordance with sprue materials shows wax sprue of 83.3%, wood sprue 81.3%, and plastic sprue of 80.7%, Wax sprue was the bast materials for casting, However there was no statistically significant difference of casting characters among was, plastic and wood. 2. The comparison of casting in accordance with sprue types shows square sprue of 94.0%, round sprue of 86.9% and triangle sprue of 84.2%. square sprue had a best casting character. 3. When a ring cast using wood sprue was classified from burying materials. its cutting of casting body and sprue indicated much more than any other sprue material. It seems to be caused by the influence of wood residuals and carbon occurrence.

  • PDF

건치아동의 경석고모형 분석에 관한 통계학적 연구 II (A STATISTICAL STUDY ON THE PLASTER CAST ANALYSIS OF THE CHILDREN AMONG HEALTHY DENTITION CONTESTANTS II)

  • 이상훈
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.365-374
    • /
    • 1996
  • The prupose of this study was to obtain standard measurements of the tooth size, Bolton ratio, width and length of dental arch and basal arch, overbite and overjet of the children who have normal dentition. The plaster cast of 97 children(47 boys and 50 girls) among the contestants in 1992, 1994, 1995 Healthy Dentition contest in Seoul were measured and following results were obtained. 1. Means and standard deviations of the mesio-distal maximum width of the permanent teeth, Bolton ratio, width and length of the dental arch and basal arch of the upper and lower dentition and overbite and overjet of the children were obtained. 2. Mesio-distal width of the teeth, width and length of the dental arch and basal arch of the upper and lower dentition of the boys were larger than those of the girls. 3. Bolton Overall ratio, Anterior ratio and overjet of the boys were larger than those of the girls and overbite of the boys were smaller than those of the girls, but no significant differences were noted between the boys and the girls(p>0.05). 4. In the comparision of the Healthy Dentition Contestants with Korean adults of Shur, all teeth of the Contestants were larger than those of Korean adults, especially upper and lower bicuspids(p<0.01). In the comparision of the Healthy Dentition Contestants with Caucasians, all teeth except upper and lower central incisor and upper first molar of the contestants were larger than those of Caucasians(p<0.05).

  • PDF

교정치료후의 변화에 관한 상악치열궁의 모형분석에 의한 연구 (MODEL ANALYSIS IN ORTHODONTIC TREATMENT CHANCES OF THE MAXILLARY DENTAL ARCH)

  • 이원철
    • 대한치과교정학회지
    • /
    • 제4권1호
    • /
    • pp.41-48
    • /
    • 1974
  • The author has selected 70 non-extraction and extraction cases. The linear measurements were made in the maxillary dental cast at pre-and post-treatment. The purpose of this study was to detect out the changes occured during orthodontic treatment. On the basis of findings of this study, the following results are made: 1. In extraction cases: 1) The maxillary intercanine width increased. 2) The maxillary dental arch width decreased. 3) The maxillary inter first molar width decreased. 4) The maxillary dental arch length decreased. 5) The maxillary dental arch length (I-3) increased. 2. In non-extraction cases, the maxillary intercanine width decreased in Angle's class III.

  • PDF

3D 프린팅 기술로 출력된 치과 보철물의 임상적 적합도 평가 (Evaluation of clinical adaptation of dental prostheses printed by 3-dimensional printing technology)

  • 김기백
    • 대한치과기공학회지
    • /
    • 제41권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Purpose: The objectives of this study was to evaluate clinical adaptation of dental prostheses printed by 3 dimensional(3D) printing technology. Methods: Ten study models were prepared. Ten specimens of experimental group were printed by 3D printing(3DP group). As a control group, 10 specimens were fabricated by casting method on the same models. Marginal gaps of all specimens were measured to evaluate clinical adaptation. Marginal adaptations were measured using silicone replica technique and measured at 8 sites per specimen. Wilcoxon's signed-ranks test was used for statistical analysis(${\alpha}=0.05$). Results: Means of marginal adaptations were $95.1{\mu}m$ for 3DP group and $75.9{\mu}m$ for CAST group(p < 0.000). Conclusion : However, the mean of the 3DP group was within the clinical tolerance suggested by the previous researchers. Based on this, dental prosthesis fabricated by 3D printing technology is considered to be clinically acceptable.

주입성형한 지르코니아 소결체의 기계적 성질에 미치는 알루미나 첨가의 영향 (Effects of the Addition of Alumina on the Mechanical Properties of Cast Zirconia Sintered Body)

  • 이동윤;조준호;서정일;배원태
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.113-119
    • /
    • 2012
  • Purpose: Zirconia blocks for all ceramic dentures are divided into two groups. One is pre-heated block and the other is binder added block. In this study, the possibility of recycling the remained parts of binder added block after CAD/CAM machining with slip casting process was investigated. Methods: Owing to the binder added block contain large amount of organic matter, Binder burn-out was must be carried out before ball milling for preparing the casting slip. Binder burn-out was accomplished at $600^{\circ}C$ for 10 hours. Ball milling was performed with 5mm zirconia ball and 60mm polyethylene bottle. From 0% to 5% at 1% intervals of alumina was added to zirconia powder for preparing slip. Solid casting was achieved with plaster mold. Cast bodies were dried and sintered at $1,500^{\circ}C$ for 1 hour. Linear shrinkage, apparent porosity, water absorption, bulk density, and flexural strength were tested. Microstructures were observed by SEM, EDS and XRD analysis were executed. Results: Optimum slips for casting was prepared with 300g ball, 100g powder, and 180g distilled water. Cast body without alumina showed 26% of linear shrinkage, 6.07 of apparent density, and 470MPa of three point bend strength. On the other hand, as received zirconia block, which was sintered at the same conditions, showed 23% of linear shrinkage, 6.10 of apparent density, and 680MPa of three point bend strength. When 3% of alumina was added to zirconia, sintered body showed 23% of linear shrinkage, 6.10 of apparent density, and 780MPa of three point bend strength. SEM photomicrographs and EDS analysis showed alumina particles uniformly dispersed in zirconia matrix, and XRD analysis showed no phase transformation of tetragonal zirconia particles was occurred when alumina was added. Conclusion: According to the all of this experimental results, 3% of alumina added cast zirconia body showed excellent mechanical properties more than as received binder containing zirconia block.

Development of implant loading device for animal study about various loading protocol: a pilot study

  • Yoon, Joon-Ho;Park, Young-Bum;Cho, Yuna;Kim, Chang-Sung;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Keun-Woo;Shim, June-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.227-234
    • /
    • 2012
  • PURPOSE. The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS. Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method, simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (${\mu}{\varepsilon}$) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS. The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION. Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.

A comparative evaluation of fracture resistance of endodontically treated teeth restored with different post core systems - an in-vitro study

  • Makade, Chetana S.;Meshram, Ganesh K.;Warhadpande, Manjusha;Patil, Pravinkumar G.
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.90-95
    • /
    • 2011
  • PURPOSE. To compare the fracture resistance and the mode of failure of endodontically treated teeth restored with different post-core systems. MATERIALS AND METHODS. Root canal treatment was performed on 40 maxillary incisors and the samples were divided into four groups of 10 each. For three experimental groups post space preparation was done and teeth were restored with cast post-core (Group B), stainless steel post with composite core (Group C) and glass fiber post with composite core using adhesive resin cement (Group D). Control group (A) samples were selected with intact coronal structure. All the samples were prepared for ideal abutment preparation. All the samples were subjected to a load of 0.5 mm/min at $130^{circ}$.until fracture occurred using the universal testing machine. The fracture resistance was measured and the data were analyzed statistically. The fracture above the embedded resin was considered to be favorable and the fracture below the level was considered as unfavorable. The statistical analysis of fracture resistance between different groups was carried out with t-test. For the mode of failure the statistical analysis was carried out by Kruskal-Wallis test and Chi-Square test. RESULTS. For experimental group Vs control group the fracture resistance values showed significant differences (P<.05). For the mode of failure the chi-square value is 16.1610, which means highly significant (P=.0009) statistically. CONCLUSION. Endodontically treated teeth without post core system showed the least fracture resistance demonstrating the need to reinforce the tooth. Stainless steel post with composite core showed the highest fracture resistance among all the experimental groups. Teeth restored with the Glass fiber post showed the most favorable fractures making them more amenable to the re-treatment.

가철성 국소의치의 진단 및 치료계획: 진단모형 분석과 지대치 선정 (Diagnosis and treatment planning for removable partial denture: diagnostic cast analysis and abutment teeth selection)

  • 손미경
    • 구강회복응용과학지
    • /
    • 제30권1호
    • /
    • pp.45-52
    • /
    • 2014
  • 진단과 치료계획의 수립은 건강한 구강조직을 유지하고 구강 내에서 잘 기능하는 국소의치 제작을 위한 치료의 시작이며 치료예후를 좌우하는 매우 중요한 요소이다. 국소의치 환자들은 잔존치아의 수나 결손부의 위치, 교합상태, 구강조직의 건강 상태 등 여러 요소에 의해 환자마다 다양한 구강 조건을 가지고 있으므로, 각각의 환자에 맞는 국소의치 제작을 위해서는 진단과 치료계획을 수립하는 단계에서 충분한 정보를 취득하는 과정이 필요하다. 특히, 방사선 사진이나 진단모형의 분석을 통해 국소의치의 지대치를 선정하고 모형의 써베잉을 시행하여 구강형성여부와 보철물의 생역학적 설계를 결정하는 것은 성공적인 국소의치 치료를 위한 필수요건이므로 이러한 과정을 이해하고 임상적으로 적용할 수 있어야 한다.

섬유강화 포스트와 금속주조 포스트의 파절강도 밋 파절양상의 비교 (COMPARISON OF FRACTURE STRENGTH AND PATTERN OF ENDODONTICALLY TREATED TEETH RESTORED WITH FIBER POSTS AND METAL CAST POST)

  • 김미경;김석규
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.535-543
    • /
    • 2004
  • Purpose: The purpose of this study is to compare the effect of two fiber post systems and one metal cast post system on the fracture strength and fracture pattern of crowned, endodontically treated teeth with 2 mm-height of the reamining tooth structure. Materials and methods: A total of 36 recently extracted sound human mandibular premolars were selected Each tooth structure of the crown portion except 2mm-height of the one above the cementoenamel junction was removed. After being endodontically treated, they were randomly distributed into 3 groups: group 1, restored with quarts fiber post(D.T. Light-Post), group 2, with glass fiber post(FRC Postec), and group 3, metal cast post and core. All teeth were fully covered with nonprecious metal crowns. Each specimen was embedded in an acrylic resin block and then secured in a universal load-testing machine. A compressive load was applied at a 130 degree angle to the long axis of the tooth until fractured, at a crosshead speed 20mm/min. The highest fracture loads were measured and recorded as the fracture strength of each specimen. Fracture areas were measured on the mid-buccal and mid-lingual point from the crown margins. One-way analysis of variance and Turkey test were used to determine the statistic significance of the different fracture loads and areas among the groups (p<0.05). Results: The mean fracture loads were $1391{\pm}$425N(group 1), $1458{\pm}476N$(group 2) and $1301{\pm}319N$(group 3). The fracture loads among the three groups had no statistically signifiant difference (p>.05). The mean fracture area of the fiber post was closer to the crown margin than that of the metal cast post and core(p<.05). The metal cast post showed unrestorable and catastrophic fracture patterns. Conclusion: Within the limitations of this study, fracture loads with any statistically significant difference were not recorded for endodontically treated teeth restored with two fiber posts and the metal cast post. But teeth restored with the fiber posts typically showed the fracture pattern close to the crown margin, which was almost restorable.

치과기공사국가시험 문항개발기준안연구 (Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician)

  • 이덕혜;정인성;한창식
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF