• 제목/요약/키워드: Dental brackets

검색결과 75건 처리시간 0.027초

ORIGINAL ARTICLE - Adhesion of Streptococcus mutans and Streptococcus sobrinus to different types of self-ligating brackets

  • Yang, Pil-Seung;Yu, Yoon-Jeong;Cha, Jung-Yul;Hwang, Chung-Ju
    • 대한치과의사협회지
    • /
    • 제50권7호
    • /
    • pp.394-406
    • /
    • 2012
  • Objective: The adhesion capabilities of different types of self-ligating brackets were measured with respect to Streptococcus mutans and Streptococcus sobrinus. Methods: Five types of self-ligating brackets (Clippy-C; Mini Clippy; Clarity-SL; Speed; Damon 3) were used for the experiment group and composite resin brackets (Spirit-MB), metal brackets (Victory) and polycrystalline alumina brackets (Clarity) were used for the control group. In order to assess adhesion of bacteria to the brackets, the brackets were cultured for 3, 6 and 24 hours in media containing bacteria and 20% sucrose. Results: There was no statistic difference in adhesion amount of Streptococcus mutans and Streptococcus sobrinus according to the types of brackets. A total adhesion amount according to bracket type was different. An extended incubation time increased adhesion amount. Observation under scanning electron microscope showed that Streptococcus sobrinus adhered more to Clippy-C and Victory rather than to Clarity-SL. Conclusions: Clarity-SL, a self-ligating esthetic bracket was confirmed to show lower bacterial adhesion to cariogenic bacteria, Streptococcus mutans and Streptococcus sobrinus group than other self-ligating brackets or conventional brackets, which suggests that proper use of self-ligating esthetic brackets might even be better in preventing tooth surface decalcification.

교정용 메탈 브라켓에서 자가중합효소연쇄반응을 통한 치아우식증 원인균의 탈출 (Direct detection of cariogenic streptococci in metal brackets in vivo using polymerase chain reaction)

  • 안석준;이신재;백승학;김태후;장영일;남동석;임범순
    • 대한치과교정학회지
    • /
    • 제35권4호
    • /
    • pp.312-319
    • /
    • 2005
  • Streptococcus mutans와 Streptococcus sobrinus는 교정장치 주위의 법랑질 탈회를 유발하는 중요한 원인균들이다. 본 연구는 중합효소연쇄반응법을 이용하여 생체 브라켓에 존재하는 이들 균주의 이환율을 평가하기 위해 고안되었다. 상악과 하악치열의 절치 브라켓 각각 4개를 교정치료 종료 시점에서 채취하였다. 브라켓에 부착된 세균들의 DNA를 추출하고 각각의 세균에 해당하는 프라이머를 이용하여 덱스트란 분해효소를 증폭시켰다. 본 연구의 결과는 S. mutans와 S. sobrinus가 하악절치 브라켓에 비해 상악절치 브라켓에 더 많이 존재함을 보여주었으며, 이들 브라켓에 존재하는 세균의 빈도는 이전의 연구에서 구강내에 존재하는 빈도에 비해 더 적음을 보여주었다. S. mutans의 상악절치 브라켓 이환율은 $50.0\%$, 하악절치 브라켓 이환율은 $33.8\%$였고, S. sobrinus는 각각 $17.5,\;15.0\%$였다. 상악절치 브라켓에 두 종류의 세균이 모두 이환된 환자는 7명 $(8.8\%)$였으며, 하악절치 브라켓에 두 종류의 세균이 모두 이환된 환자는 5명 $(6.3\%)$였다. 본 연구의 결과는 법랑질 탈회를 유발하는 치아우식증 원인균이 절치 브라켓에 부착하는 상주균일 가능성을 제시한다.

In vitro physical, chemical, and biological evaluation of commercially available metal orthodontic brackets

  • Kim, Joo Hyoung;Cha, Jung Yul;Hwang, Chung Ju
    • 대한치과교정학회지
    • /
    • 제42권6호
    • /
    • pp.297-306
    • /
    • 2012
  • Objective: This in vitro study was undertaken to evaluate the physical, chemical, and biological properties of commercially available metal orthodontic brackets in South Korea, because national standards for these products are lacking. Methods: Four bracket brands were tested for dimensional accuracy, (manufacturing errors in angulation and torque), cytotoxicity, composition, elution, and corrosion: Archist (Daeseung Medical), Victory (3M Unitek), Kosaka (Tomy), and Confidence (Shinye Odontology Materials). Results: The tested rackets showed no significant differences in manufacturing errors in angulation, but Confidence brackets showed a significant difference in manufacturing errors in torque. None of the brackets were cytotoxic to mouse fibroblasts. The metal ion components did not show a regular increasing or decreasing trend of elution over time, but the volume of the total eluted metal ions increased: Archist brackets had the maximal Cr elution and Confidence brackets appeared to have the largest volume of total eluted metal ions because of excessive Ni elution. Confidence brackets showed the lowest corrosion resistance during potentiodynamic polarization. Conclusions: The results of this study could potentially be applied in establishing national standards for metal orthodontic brackets and in evaluating commercially available products.

TiN 및 ZrN 코팅된 교정용 브라켓의 부식특성 (Corrosion Characteristics of TiN and ZrN Coated Orthodontic Brackets)

  • 김원기;김도영;최한철
    • 한국표면공학회지
    • /
    • 제41권4호
    • /
    • pp.163-168
    • /
    • 2008
  • The dental orthodontic bracket requires good mechanical properties, such as elastic strength and frictional resistance, combined with a high resistance to corrosion. The objective of this study was to investigate the effects of TiN and ZrN coating on corrosion resistance of orthodontic brackets using various electrochemical methods. Brackets manufactured by Ormco Co. were used, respectively, for experiment. Ion plating was carried out for coatings of bracket using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen was observed with field emission scanning electron microscopy(FE-SEM), energy dispersive Xray spectroscopy(EDS) and electrochemical tester. The corrosion potential of the TiN and ZrN coated bracket was comparatively high. The current density of TiN and ZrN coated bracket was smaller than that of non-coated bracket in 0.9% NaCl solution. Pit nucleated at angle of bracket slot.

Effects of silanation time on shear bond strength between a gold alloy surface and metal bracket

  • Jung, Min-Ho;Shon, Won-Jun;Park, Young-Seok;Chung, Shin-Hye
    • 대한치과교정학회지
    • /
    • 제43권3호
    • /
    • pp.127-133
    • /
    • 2013
  • Objective: We aimed to investigate the effects of silanation time on the shear bond strength (SBS) of metal brackets on gold alloy in a silicoating procedure and compare the SBS of metal brackets on gold alloy and enamel. Methods: Type III gold alloy plates were sandblasted with 30-${\mu}m$ silicon dioxide. Excess particles were removed with gentle air after silica coating, and silane was applied. Maxillary central-incisor metal brackets were bonded to each conditioned alloy surface with a light curing resin adhesive for 1 s, 30 s, 60 s, or 120 s after applying silane. The brackets were also bonded to 36 upper central incisors with the same adhesive. All samples were cured for 40 s with a light emitting diode curing light. The SBS was tested after 1 h and after 24 h. The adhesive remnant index (ARI) of the samples was also compared. Results: The 60-s and 120-s silanation time groups showed a higher SBS than the other groups (p < 0.05). Samples tested after 24 h showed a significantly higher SBS than did the samples tested after 1 h (p < 0.05). The 1-s group showed higher ARI scores. The one-way analysis of variance and Student-Newman-Keuls test showed that the SBS values of the 60-s and 120-s silanation time groups were not significantly different from the SBS values of enamel. Conclusions: Adequate silanation time is required to produce sufficient bond strength during silicoating.

개인 맞춤형 장치를 이용한 디지털 교정치료 (Digital Orthodontics using Customized Appliance System)

  • 김윤지;하혜정;이성종;이언화;류재준
    • 대한치과의사협회지
    • /
    • 제54권2호
    • /
    • pp.134-141
    • /
    • 2016
  • Use of ready-made orthodontic appliance can lead to inefficiencies in the final stages of the orthodontic treatment. Because patients' teeth have anatomic variations, brackets that have been designed to fit on average tooth surface may result in positional discrepancies when leveling and alignment is completed. As a result, additional steps such as rebonding, wire bending and use of auxiliaries may be needed. Even in patients who have normal tooth anatomy and proper tooth size relationships, precise bracket placement is crucial in order to efficiently control the tooth positions. Digital models can provide advantages in clinical orthodontics as virtual tooth setup could be performed, and clinicians can easily visualize the predicted final occlusion. Through this setup model, customized brackets with individualized prescription and archwires that optimally fit with the patients' dental arches can be produced using CAD/CAM technology. Also, the brackets can be accurately placed with an aid of 3D-printed jigs. The purpose of this article is to introduce the commonly used labial and lingual customized orthodontic appliance systems using digital technology.

  • PDF

Comparative evaluation of shear bond strength of orthodontic brackets bonded to three-dimensionally-printed and milled materials after surface treatment and artificial aging

  • Ameer Biadsee;Ofir Rosner;Carol Khalil;Vanina Atanasova;Joel Blushtein;Shifra Levartovsky
    • 대한치과교정학회지
    • /
    • 제53권1호
    • /
    • pp.45-53
    • /
    • 2023
  • Objective: This study aimed to evaluate the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensionally (3D)-printed materials after various surface treatments and artificial aging compared with that bonded to computer-aided design/computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA)-milled materials. Methods: Eighty cylindrical specimens were 3D printed and divided into the following four subgroups (n = 20 each) according to the surface treatment and artificial aging procedure. Group A, sandblasted with 50 ㎛ aluminum oxide particles (SA) and aging; group B, sandblasted with 30 ㎛ silica-coated alumina particles (CO) and aging; group C, SA without aging; and group D, CO without aging. For the control group, 20 CAD-CAM PMMA-milled cylindrical specimens were sandblasted with SA and aged. The SBS was measured using a universal testing machine (0.25 mm/min), examined at ×2.5 magnification for failure mode classification, and statistically analyzed (p = 0.05). Results: The retention obtained with the 3D-printed materials (groups A-D) was higher than that obtained with the PMMA-milled materials (control group). However, no significant difference was found between the study and control groups, except for group C (SA without aging), which showed significantly higher retention than the control group (PMMA-SA and thermocycling) (p = 0.037). Study groups A-D predominantly exhibited a cohesive specimen mode, indicating specimen fracture. Conclusions: Orthodontic brackets bonded to 3D-printed materials exhibit acceptable bonding strengths. However, 3D-printed materials are prone to cohesive failure, which may result in crown fractures.

The effect of occlusogingival placement of clinical bracket points on the adaptation of a straight wire to the lingual arch form

  • Abdi, Amir Hossein;Motamedian, Saeed Reza;Balaghi, Ehsan;Nouri, Mahtab
    • 대한치과교정학회지
    • /
    • 제48권4호
    • /
    • pp.236-244
    • /
    • 2018
  • Objective: The aim of this study is to compare the adaptation of a straight wire between brackets positioned at the mid-lingual surface and those placed gingivally by using a three-dimensional simulation software. Methods: This cross-sectional study was performed using OrthoAid, an in-house software. The subjects were 36 adolescents with normal Class I occlusion. For each dental cast, two bracket positioning approaches, namely the middle and gingival, were examined. In the middle group, the reference points were placed on the mid-lingual surface of each tooth, while in the gingival group, the reference points were positioned lingually on the anterior teeth. A 4th degree polynomial was adopted, and the in-plane and off-plane root mean squares (RMSs) of the distances between the reference points and the fitted polynomial curve were calculated using the software. Statistical analysis was performed using the paired-samples t-test (${\alpha}=0.05$). Results: The mean in-plane RMS of the polynomial curve to the bracket distance in the gingival group was significantly lower than that in the middle group (p < 0.001). The off-plane RMS was higher in the gingivally positioned brackets in the maxilla than in the middle group (p < 0.001). However, the off-plane RMS in mandible was not statistically significantly different between the two groups (p = 0.274). Conclusions: The results demonstrated that the gingival placement of lingual brackets on the anterior teeth could decrease the distance between a tooth and the straight wire.

수종 교정용 접착제의 전단 접착강도 비교 (A COMPARISON OF SHEAR BOND STRENGTH OF VARIOUS ORTHODONTIC ADHESIVES)

  • 유미희;황충주
    • 대한치과교정학회지
    • /
    • 제24권2호
    • /
    • pp.433-445
    • /
    • 1994
  • Bonding of brackets is one of the essential factors for successful orthodontic treatment' so bond strength of orthodontic adhesives are very important. The purposes of this research were to compare shear bond strength of various orthodontic adhesives and to evaluate failure sites. One-hundred twenty extracted human first premolars were prepared for bonding and premolar brackets were bonded to prepared enamel surfaces with Super C Ortho, Mono-$Lok^2$, Transbond, and Super C Ortho after applying Fluorobond. After bonding of brackets, teeth specimens were divided into 3 groups. In group 1 specimens were stored at humidor $37^{\circ}C$ in 1 hour, in group 2 specimens were stored at humidor $37^{\circ}C$ in 24 hours, thermocycled 10 times and in group 3 specimens were stored at humidor $37^{\circ}C$ in 24 hours, thermocycled 1800 times. Then the universal testing machine Instron 6022, Instron Co., U.S.A. was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites The results were as follows : 1. Shear bond strength was significantly highest of using Super C Ortho after applying Fluorobond and Super C Ortho In group 1, was highest of using Super C Ortho in group 2, and was highest of using Mono-$Lok^2$ in group 3. 2. According to time and temperature change, in using Super C Ortho the group 2 had significantly highest strength and group 3 had lowest strength, in using Mono-$Lok^2$ the group 2 and had higher strength than group 1 and in using Super C Ortho after applying Fluorobond shear bond strength decreased constantly, 3. The failure sites were tooth-resin interface in Super C Ortho after applying Fluorobond, Mono $Lok^2$ and Transbond and were at almost same ratio bracket base-resin interface and tooth-resin interface in Super C Orth.

  • PDF

Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives

  • Goracci, Cecilia;Ozcan, Mutlu;Franchi, Lorenzo;Di Bello, Giuseppe;Louca, Chris;Vichi, Alessandro
    • 대한치과교정학회지
    • /
    • 제49권6호
    • /
    • pp.404-412
    • /
    • 2019
  • Objective: To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following substrate chemical or mechanical treatment. Methods: Two types of PMMA blocks were tested: $CAD-Temp^{(R)}$ (VITA) and $Telio^{(R)}$ CAD (Ivoclar-Vivadent). The substrate was roughened with 320-grit sandpaper, simulating a fine-grit diamond bur. Two universal adhesives, Scotchbond Universal Adhesive (SU) and Assure Plus (AP), and a conventional adhesive, Transbond XT Primer (XTP; control), were used in combination with Transbond XT Paste to bond the brackets. Six experimental groups were formed: (1) $CAD-Temp^{(R)}/SU$; (2) $CAD-Temp^{(R)}/AP$; (3) $CAD-Temp^{(R)}/XTP$; (4) $Telio^{(R)}$ CAD/SU; (5) $Telio^{(R)}$ CAD/AP; (6) $Telio^{(R)}$ CAD/XTP. Shear bond strength and ARI were assessed. On 1 extra block for each PMMA-based material surfaces were roughened with 180-grit sandpaper, simulating a normal/medium-grit ($100{\mu}m$) diamond bur, and brackets were bonded. Shear bond strengths and ARI scores were compared with those of groups 3, 6. Results: On $CAD-Temp^{(R)}$ significantly higher bracket bond strengths than on $Telio^{(R)}$ CAD were recorded. With XTP significantly lower levels of adhesion were reached than using SU or AP. Roughening with a coarser bur resulted in a significant increase in adhesion. Conclusions: Bracket bonding to CAD/CAM PMMA can be promoted by grinding the substrate with a normal/medium-grit bur or by coating the intact surface with universal adhesives. With appropriate pretreatments, bracket adhesion to CAD/CAM PMMA temporary restorations can be enhanced to clinically satisfactory levels.