• 제목/요약/키워드: Dental bone plate

검색결과 70건 처리시간 0.021초

치과용 Ti-6Al-4V 합금 골 고정판 표면에 형성된 나노튜브의 부식거동 (Corrosion Behavior of Nanotube Formed on the Bone Plate of Ti-6Al-4V Alloy for Dental Use)

  • 김원기;이충환;정재헌;최한철
    • 한국표면공학회지
    • /
    • 제43권1호
    • /
    • pp.25-30
    • /
    • 2010
  • Titanium and titanium alloys are widely used for orthopedic and dental implants for their superior mechanical properties, low modulus, excellent corrosion resistance and good biocompatibility. In this study, corrosion behaviors of nanotube formed on the bone plate of Ti-6Al-4V alloy for dental use have been investigated. $TiO_2$ nanotubes were formed on the dental bone plates by anodization in $H_3PO_4$ containing 0.6 wt % NaF solution at $25^{\circ}C$. Electrochemical experiments were performed using a conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. Anodization was carried out using a scanning potentiostat (EG&G Co, Model 263A USA), and all experiments were conducted at room temperature. The surface morphology was observed using field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The corrosion behavior of the dental bone plates was examined using potentiodynamic test(potential range of -1500~2000 mV) in a 0.9% NaCl solution by potentiostat (EG&G Co, PARSTAT 2273. USA). The inner diameter of nanotube was about 150~180 nm with wall thickness of about 20 nm. The interspace of nanotube to nanotube was 50 nm. The passive region of the nanotube formed bone plates showed the broad range compared to non-nanotube formed bone plates. The corrosion surface of sample was covered with corrosion products.

Isolated tympanic plate fracture detected by cone-beam computed tomography: report of four cases with review of literature

  • Kalaskar, Ashita Ritesh;Kalaskar, Ritesh
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권5호
    • /
    • pp.356-360
    • /
    • 2017
  • The tympanic plate is a small part of the temporal bone that separates the mandibular condyle from the external auditory canal. Fracture of this small plate is rare and usually associated with other bony fractures, mainly temporal and mandibular bone. There is a limited amount of literature on this subject, which increases the chance of cases being overlooked by physicians and radiologists. This is further supported by purely isolated cases of tympanic plate fracture without evidence of other bony fractures. Cone-beam computed tomography is an investigative three-dimensional imaging modality that can be used to detect fine structures and fractures in maxillofacial trauma. This article presents four cases of isolated tympanic plate fracture diagnosed by cone-beam computed tomography with no evidence of fracture involving other bones and review of the literature.

Maxillary reconstruction using tunneling flap technique with 3D custom-made titanium mesh plate and particulate cancellous bone and marrow graft: a case report

  • Takano, Masayuki;Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Homma, Shinya;Abe, Shinichi;Katakura, Akira;Shibahara, Takahiko
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.43.1-43.5
    • /
    • 2019
  • Background: Reconstructive surgery is often required for tumors of the oral and maxillofacial region, irrespective of whether they are benign or malignant, the area involved, and the tumor size. Recently, three-dimensional (3D) models are increasingly used in reconstructive surgery. However, these models have rarely been adapted for the fabrication of custom-made reconstruction materials. In this report, we present a case of maxillary reconstruction using a laboratory-engineered, custom-made mesh plate from a 3D model. Case presentation: The patient was a 56-year-old female, who had undergone maxillary resection in 2011 for intraoral squamous cell carcinoma that presented as a swelling of the anterior maxillary gingiva. Five years later, there was no recurrence of the malignant tumor and a maxillary reconstruction was planned. Computed tomography (CT) revealed a large bony defect in the dental-alveolar area of the anterior maxilla. Using the CT data, a 3D model of the maxilla was prepared, and the site of reconstruction determined. A custom-made mesh plate was fabricated using the 3D model (Okada Medical Supply, Tokyo, Japan). We performed the reconstruction using the custom-made titanium mesh plate and the particulate cancellous bone and marrow graft from her iliac bone. We employed the tunneling flap technique without alveolar crest incision, to prevent surgical wound dehiscence, mesh exposure, and alveolar bone loss. Ten months later, three dental implants were inserted in the graft. Before the final crown setting, we performed a gingivoplasty with palate mucosal graft. The patient has expressed total satisfaction with both the functional and esthetic outcomes of the procedure. Conclusion: We have successfully performed a maxillary and dental reconstruction using a custom-made, pre-bent titanium mesh plate.

총상으로 인한 하악골 결손 부위의 Tantalum plate 대치를 위한 장골이식에 관한 증례 (ILIAC BONE GRAFT REPLACING TANTALUM PLATE FOR GUNSHOT WOUND OF MANDIBLE)

  • 김수남;이봉재;한보균
    • 대한치과의사협회지
    • /
    • 제15권5호
    • /
    • pp.359-364
    • /
    • 1977
  • Orthognathic surgery, ie, the surgical correction of congenital and acquaired anormalities of the jaws, is currently a field of vigorous activity among oral surgeons. Surgical correction of maxillofacial deformities benefits the patient both psychologically and functionally. Facial mutilation may precipitate adverse psychologic effects. Function is frequently impaired by malrelation of the jaws. In addition, speech, specifically articulation, is often handicapped in patient with severe jaw deformities. Therefore, in dealing with these patient, above mentioned problem should be considered deliberately. In this regard, the authors have treated 2 cases of mandible defect caused by gunshot and explosives with iliac bone graft. In both cases, the patient had Tantalum plate on defect area. But it became lose and gave functional disturbances. So, the authors have removed Tantalum plate and performed bone transplantation with autogenous soild iliac bone graft on that area with good results.

  • PDF

발치즉시 임플란트 식립시 골이식 (Bone Graft in Immediate Implantation after Anterior Tooth Extraction)

  • 김영균
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.725-732
    • /
    • 2017
  • Thin labial plate will be resorbed after extraction. Immediate implantation cannot prevent soft and hard tissue loss. Bone graft can be necessary in the immediate implantation after anterior tooth extraction. Slowly-resorbed or non-resorbable bone graft material have many advantages in esthetic area because of maintenance of volume. The clinicians should select the adequate cases of immediate implantation according to the indication and contraindication.

  • PDF

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • 제4권1호
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.

Apicoectomy of maxillary anterior teeth through a piezoelectric bony-window osteotomy: two case reports introducing a new technique to preserve cortical bone

  • Hirsch, Viola;Kohli, Meetu R.;Kim, Syngcuk
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.310-315
    • /
    • 2016
  • Two case reports describing a new technique of creating a repositionable piezoelectric bony window osteotomy during apicoectomy in order to preserve bone and act as an autologous graft for the surgical site are described. Endodontic microsurgery of anterior teeth with an intact cortical plate and large periapical lesion generally involves removal of a significant amount of healthy bone in order to enucleate the diseased tissue and manage root ends. In the reported cases, apicoectomy was performed on the lateral incisors of two patients. A piezoelectric device was used to create and elevate a bony window at the surgical site, instead of drilling and destroying bone while making an osteotomy with conventional burs. Routine microsurgical procedures - lesion enucleation, root-end resection, and filling - were carried out through this window preparation. The bony window was repositioned to the original site and the soft tissue sutured. The cases were re-evaluated clinically and radiographically after a period of 12 - 24 months. At follow-up, radiographic healing was observed. No additional grafting material was needed despite the extent of the lesions. The indication for this procedure is when teeth present with an intact or near-intact buccal cortical plate and a large apical lesion to preserve the bone and use it as an autologous graft.

Removal of miniplates following facial trauma and orthognathic surgery: a 3-year study

  • Shin, Na-Ra;Oh, Ji-Su;Shin, Sang-Hun;Kim, Su-Gwan
    • 구강생물연구
    • /
    • 제42권4호
    • /
    • pp.222-227
    • /
    • 2018
  • The purpose of this study was to determine the cause and risk factors of removing bone plateby investigating and analyzing 359 patients who underwent reduction of fracture or orthognathic surgery with bone plate insertion over the past 3 years. Patients were evaluated with respect to age, smoking status, reason for insertion of plates, the numbers of inserted plates, sites of insertion, time between insertion and removal, reasons for removal of plates. The removal rate of bone plates was 33.1%. Of these, 17.0% of patients had clinical symptoms which led to remove plates. The removal rate of men was 29.9% and the rate of women was 39.2%. There were high removal rates from less than 20s (45.8%) and 20s (34.4%) those who are relatively young age group. On the other hand people in their 50s had a removal rate of 27.8% which was higher than those in their 60s with a rate of 20.7%. The removal rate of bone plate inserted into the mandible was 33.5%, and the removal rate of bone plate inserted into the maxilla was 34.7%. The mean period between the insertion and removal of bone plate was 10.9 months. The main reason for the removal of bone plate was the patient's requirement (44.5%). The most common cause of clinical symptoms was infection (22.7%). Infection was manifested within about a year and led to the plate being removed. Therefore, lowering the possibility of infection after surgery could decrease the removal rate of bone plate.

임프란트를 이용한 고정성 계속가공의치의 FRAMEWORK 형태에 관한 연구 (A SUTDY ABOUT THE SHAPE OF THE FRAMEWORK OF THE FIXED BONE ANCHORED BRIDGE USING DENIAL IMPLANTS)

  • 김태균;이영수;유광희
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.104-119
    • /
    • 1998
  • The purpose of this study was pertinent design of the framework of the fixed bone anchored bridge using implants in the edentulous mandible through analysis of stress distribution by the three dimensional finite element analysis method. The results were as follows: 1. The L-shaped framework was favorable in restoring the edentulous mandible by implants and fixed bone anchored bridge. 2. The structure of the framework should be designed to endure the occlusal load because of stress concentration at the most distal abutment of the framework. 3. The stress at the distal implant where cantilever starts was twice as much as that of other portions. 4. Compressive stress was generated on the framework of the mesial side of the distal implant and extrusive force was induced to the mesially positioned implants. 5. The height of vertical plate was high as possible as can be to distribute stresses concentrating bucco-lingually and labio-lingually in the framework between abutments, 6. Reinforcement of the horizontal plate thickness was needed because stress was loaded more on the horizontal plate than on the vertical plate of the framework. 7. Lengthening of the vertical plate can compensate for any limitations in horizontal plate width.

  • PDF