• 제목/요약/키워드: Dental abrasion

검색결과 114건 처리시간 0.022초

Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion

  • Korkmaz, Fatih Mehmet;Bagis, Bora;Ozcan, Mutlu;Durkan, Rukiye;Turgut, Sedanur;Ates, Sabit Melih
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.287-295
    • /
    • 2013
  • PURPOSE. This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS. Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) ($75mm{\times}25mm{\times}3mm$). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion ($50{\mu}m$), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (${\alpha}$=.05). RESULTS. Denture liner tested showed increased peel strength after laser treatment with different parameters ($3.9{\pm}0.4-5.58{\pm}0.6$ MPa) compared to the control ($3.64{\pm}0.5-4.58{\pm}0.5$ MPa) and air-abraded groups ($3.1{\pm}0.6-4.46{\pm}0.3$ MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups ($3.1{\pm}0.6$ MPa). CONCLUSION. Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.

미세입자 분사마모 표면처리가 Fiber-Reinforced Composite 포스트의 굴곡 강도에 미치는 영향 (Influence of airborne-particle abrasion on flexural strength of fiber-reinforced composite post)

  • 심은주;김진우;조경모;박세희
    • 구강회복응용과학지
    • /
    • 제32권1호
    • /
    • pp.24-31
    • /
    • 2016
  • 목적: 미세입자 분사마모 표면처리가 Fiber-Reinforced Composite (FRC) 포스트의 굴곡강도에 미치는 영향을 평가하는 것이다. 연구 재료 및 방법: 두 종류의 FRC 포스트 (DT Light Post, Size 2, Bisco Inc. / RelyX Fiber Post, Size 3, 3M ESPE)를 사용하여 표면처리에 따라 6개의 그룹으로 무작위 분류하였다. 표면처리를 위해 $30{\mu}m$ Rocatec Soft와 $50{\mu}m$ aluminum oxide를 사용하였다. 표면처리 후 편평한 5 mm 부분을 만능시험기로 3점 굽힘시험을 시행하여 FRC 포스트의 굴곡강도와 굴곡계수를 측정하고 통계분석하였다. 결과: FRC포스트의 미세입자 분사마모 표면처리가 FRC포스트의 굴곡강도와 굴곡계수에는 영향을 미치지 않음을 알 수 있었다. 결론: 임상가들이 FRC포스트에 대하여 미세입자 분사마모 표면처리를 하여도 포스트의 굴곡강도와 굴곡계수에는 영향을 미치지 않으면서 접착강도를 높일 수 있을 근거 중의 하나가 될 수 있을 것이다.

치아수복용 고분자 나노복합체의 물성 (Properties of Polymer Nanocomposites Useful for Dental Restoration)

  • 김오영;한상혁;서기택;공명선;김창근;임범순;조병훈
    • 공업화학
    • /
    • 제16권3호
    • /
    • pp.422-426
    • /
    • 2005
  • 가시광선에 의해 활성화되는 치아수복용 고분자 나노복합체를 제조하고 이들의 주요 물성을 고찰하였다. 복합체 제조에 사용한 충진재는 barium silicate와 나노 크기의 fumed silica가 혼합된 하이브리드 충진재를 사용하였으며 bisphenol A glycerolate methacrylate와 triethyleneglycol dimethacrylate로 구성되는 resin matrix와의 계면력 향상을 위해 실란 결합제로 표면을 소수성으로 처리하였다. 제조된 고분자 나노복합체의 기계적 물성을 평가한 결과, 나노 충진재가 첨가됨에 따라 내마모성이 향상되었다. 그러나 중합수축률 값은 나노 충진재 함량에 관계없이 3 vol% 이하로 거의 일정하였으며 광조사가 끝난 후에도 중합수축은 지속적으로 일어남을 알 수 있었다. 또한 복합체의 색차는 나노 충진재 함량이 늘어남에 따라 근소한 차이로 증가되었다.

칫솔질에 의한 레진 표면 강화재의 마모 (THE ABRASION OF SURFACE PENETRATING SEALANT BY TOOTH-BRUSHING)

  • 송주현;한세현;장기택;이상훈
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.633-642
    • /
    • 2006
  • 본 연구는 레진 표면을 연마한 후 레진 표면 강화재를 도포한 것이 표면 처리하지 않은 군에 비해 칫솔질 마모시 표면 특성 즉, 표면 조도, 표면 자유 에너지, 마모율 등의 변화가 있는지 알아 보기 위해 시행하여 다음과 같은 결과를 얻었다(p=0.05). 1. 평균 조도는 Biscover < Forify < Polishing군 순이었다. 마모 전과 6개월에서는 모든 군에서 유의한 차이를 보였고, 1개월, 2개월, 3개월에서는 Polishing군과 Fortify군, Polishing군과 Biscover군에서 유의한 차이를 보였다. 2. 표면 자유 에너지는 마모 전은 Polishing군과 Biscover군, Fortify군과 Biscover군에서 유의한 차이를 보였고(Biscover < Fortify < Polishing), 1개월에서는 Polishing군과 Fortify군에서 유의한 차이를 보였으며, 2개월에서는 각 군간 유의한 차이를 보이지 않았다. 3개월에서는 Fortify군과 Biscover군에서 유의차를 보였고, 6개월에서는 Polishing군과 Fortify군, Fortify군과 Biscover군에서 유의한 차이를 보였다 (Fortify < Polishing < Biscover). 3. 마모율은 1개월에서 모든 군에서 유의차를 보였으며, 2개월에서는 군 간 유의차가 없었고, 3개월과 $4{\sim}6$개월 평균 마모율은 Polishing군과 Biscover군, Fortify군과 Biscover군에서 유의한 차이를 보였다. Fortify와 Biscover의 두께를 고려했을 때, Fortify는 2개월 내에, Biscover는 6개월 정도에 거의 소실되었다.

  • PDF

치은 퇴축과 치경부 마모의 임상적 변수에 관한 연구 (The Effects of Clinical Parameters on Gingival Recession and Cervical Abrasion)

  • 김은정;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제31권1호
    • /
    • pp.243-258
    • /
    • 2001
  • Gingival recession is exposure of the root surface with apical shift in the position of gingiva. The incidence of gingival recession is 8% in children and 100% after the age of 50. Recession tends to be found in patients with healthy gingiva, but more frequentely found in patients with periodontal disease, and it often causes mucogingival defects. Buccal surface of premolar is the area not only for severe gingival recession and cervical abrasion, but also the area of numbers of buccal frenum and less keratinized gingiva. Threrfore, the goal of this study was to observe the patients with periodontitis and examine whether there are clinical relations between gingival recession and cervical abrasion of premolar and other factors related with the condition of periodontal health. Generally healthy 218 patients who had periodontitis, aged between 18 and 78, were examined for depth of periodontal poket, width of attached gingival, gingival recession, cervical abrasion, and frenum of mid-buccal surface of premolar at the Department of Periodontics in Dankook University Dental Hospital and following is the result. 1. The average gingival recession and cervical abrasion of premolar with periodontal disease was 0.76mm and 0.29mm and each has 43% and 14% of incidence. Also the width of attached gingiva of mid-buccal surface was 1.77mm. the average periodontal pocket depth is 2.0mm and 47% of frequently seen was narrow single shaped frenum, and the interdistance of the frenum was mostly over 4mm. 2. With statistical significance(P<0.05), the incidence of gingival recession increased with age and was related much more with female than male, the first premolar than the second premolar, and with narrow attached gingiva and frenum. 3. With statistical significance(p<0.05), the incidence of cervical abrasion increased with age and was related with the area of the first premolar and narrow attached gingiva, but the sexual and frenum differences were not statistically significant (p>0.05). 4. The severity of gingival recession increased with age and was more related with female than male, the first premolar than the second premolar. And the area of narrow attached gingiva and frenum showed more gingival recession and the distance of frenum was more highly related than shape, and they were statistically significant (p<0.05). 5. With statistical significance(p<0.05), the severity of cervical abrasion increase with age and was observed at the first premolar and narrow attached gingiva. But the sexual and frenum differences were not statistically significant (p>0.05).

  • PDF

의치용 레진치와 수복용 복합레진 간의 결합강도에 관한 연구 (SHEAR BOND STRENGTHS BETWEEN ABRASION-RESISTANT DENTURE TEETH AND COMPOSITE RESINS)

  • 김미리;정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제40권2호
    • /
    • pp.201-212
    • /
    • 2002
  • This study investigated the shear bond strengths between abrasion-resistant denture teeth and composite resins according to surface treatments. Denture teeth for this study were Trubyte IPN teeth(Dentsply Inc., USA) with interpenetrating polymer network and Endura Posterio (Shofu Inc. Japan) of composite resin teeth, and restorative composite resins were Clearfil FII (Kuraray, Japan) of the self-cured composite resin and Z100(3M Dental Product, USA) of the light-cured composite resin. Five different surface treatments were evaluated: (1) $50{\mu}m\;A1_2O_3$ sandblasting: (2) #100 carbide paper; (3) chloroform; (4) retentive holes; and (5) no treatment. After surface treatments, denture teeth were examined by scanning electron microscopy(SEM), and the maximum shear bond strengths between abrasion-resistant denture teeth and composite resins were measured using Instron. The results were as follows; 1. IPN teeth treated with sandblasting had the highest shear bond strength, and Endura treated with sandblasting and carbide paper had significantly greater shear bond strength than with any other surface treatment. 2. Regardless or composite resins, the shear bond strength on Endura was greater than on IPN teeth. 3. Regardless of denture teeth, the shear bond strength of Clearfil FII was greater han of Z100. 4. In appearance of SEM, IPN teeth treated with sandblasting showed generalized roughness on the all of surface, however, carbide paper treatment resulted in partly rough. Endura treated with sandblasting and carbide paper showed similar surface characteristics. Wetting denture teeth surface with chloroform removed the debris and created a particle-free and smooth surface.

Efficacy of various cleaning solutions on saliva-contaminated zirconia for improved resin bonding

  • Kim, Da-Hye;Son, Jun-Sik;Jeong, Seong-Hwa;Kim, Young-Kyung;Kim, Kyo-Han;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.85-92
    • /
    • 2015
  • PURPOSE. This study aimed to investigate the efficacy of cleaning solutions on saliva-contaminated zirconia in comparison to air-abrasion in terms of resin bonding. MATERIALS AND METHODS. For saliva-contaminated air-abraded zirconia, seven cleaning methods)-no contamination (NC), water-spray rinsing (WS), additional air-abrasion (AA), and cleaning with four solutions (Ivoclean [IC]; 1.0 wt% sodium dodecyl sulfate [SDS], 1.0 wt% hydrogen peroxide [HP], and 1.0 wt% sodium hypochlorite [SHC])-were tested. The zirconia surfaces for each group were characterized using various analytical techniques. Three bonded resin (Panavia F 2.0) cylinders (bonding area: $4.5mm^2$) were made on one zirconia disk specimen using the Ultradent jig method [four disks (12 cylinders)/group; a total of 28 disks]. After 5,000 thermocycling, all specimens were subjected to a shear bond strength test with a crosshead speed of 1.0 mm/minute. The fractured surfaces were observed using an optical and scanning electron microscope (SEM). RESULTS. Contact angle measurements showed that groups NC, AA, IC, and SHC had hydrophilic surfaces. The X-ray photoelectron spectroscopy (XPS) analysis showed similar elemental distributions between group AA and groups IC and SHC. Groups IC and SHC showed statistically similar bond strengths to groups NC and AA (P>.05), but not groups SDS and HP (P<.05). For groups WS, SDS, and HP, blister-like bubble formations were observed on the surfaces under SEM. CONCLUSION. Within the limitations of this in vitro study, some of the cleaning solutions (IC or SHC) were effective in removing saliva contamination and enhancing the resin bond strength.

구강보건교육 프로그램이 성인집단의 구강보건지식 및 구강건강행위에 미치는 영향 (The effect of dental health education on dental health knowledge, dental health behavior of adult group)

  • 이향님
    • 한국치위생학회지
    • /
    • 제4권1호
    • /
    • pp.93-103
    • /
    • 2004
  • This study was conducted to evaluated the effects of improvement on dental health behavior and dental health knowledge of adult group through dental health education program, the study subjects were 75, education group being 37(male 19, female 18) and non-education group being 38(male 19, female 19). who being in 2 office. The results of this study were as follow: 1. In the primary survey, the education group and non-education group showed no differences in sex, age, job year, income, smoking, self-rated dental health statues, DMFT index, a number of cervical abrasion tooth, dental health behavior, dental health knowledge. 2. before education program the use of tooth brushing method of horizontal+vertical was 40.6%, after education program the use of tooth brushing method of rolling was 89.2% in education group. 3. after education program the tooth brushing times was increased after-meal brushing, especially increased from 40.5% to 93.8% at after midday meal brushing. 4. the difference of mean change of dental health knowledge score after oral health education program had been studied. dental health knowledge score increased in 9.8 in the education group and non-education group in 1.6(pE0.001). 5. the difference of mean change of oral health promotion behavior after oral health education program had been studied, the frequence of tooth brushing(pE0.05), flossing(pE0.001), tongue brushing(pE0.001) was significantly increased in education group compare to non-education group. Above findings suggest that dental health education program was effective in improving the dental health behavior, dental health knowledge of the adult group.

  • PDF

Analysis of the Difference in the Importance of Instructors and Clinical Dental Hygienists for Oral Pathology Learning Objectives

  • Lee, Sun-Mi;Lee, Jung–Hwa;Cho, Eunae Sandra
    • 치위생과학회지
    • /
    • 제22권1호
    • /
    • pp.9-19
    • /
    • 2022
  • Background: The purpose of this study was to identify the differences in the importance of oral pathology learning objectives for instructors and clinical dental hygienists and provide basic data that can guide learning objectives for acquiring practically necessary basic knowledge in the clinical field. Methods: Through the first-stage expert meeting, 27 items with less than four points out of 129 learning objectives in 15 detailed areas were deleted, 12 additional opinions were reflected, 114 learning objectives were set, and a survey was conducted with 253 people. Results: There were statistically significant differences in 92 items after examining the difference between professors and clinical dental hygienists. Among the areas of inflammation and repair, "Can explain the five symptoms of inflammation" had the highest with a score at 4.76 in the case of the professors. Among the areas of tooth damage, "Can explain abrasion" had the highest with a score at 4.61 in the case of the clinical dental hygienists. Conclusion: I would like to propose the existing 15 detail areas and 129 learning objectives as 14 detail areas and 98 learning objectives and strengthen the job competency of dental hygienists in the future. First, you need to develop competencies that are highly relevant to your work. Second, it is necessary to develop related textbooks and educational materials based on revised learning objectives and competencies. Third, based on revised learning objectives, the dental hygienist national examination should be improved. Through these changes in education, the education of oral and maxillofacial disease subjects should strengthen job competencies among dental hygienists with learning objectives that can be applied to actual clinical practice based on basic knowledge rather than knowledge orientation. In addition, it is possible to improve the quality of dental hygiene studies.

생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성 (Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant)

  • 장갑성;김흥중;박주철;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF