• Title/Summary/Keyword: Dental X-ray image

Search Result 93, Processing Time 0.03 seconds

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF

Investigation of the Super-resolution Algorithm for the Prediction of Periodontal Disease in Dental X-ray Radiography (치주질환 예측을 위한 치과 X-선 영상에서의 초해상화 알고리즘 적용 가능성 연구)

  • Kim, Han-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 2021
  • X-ray image analysis is a very important field to improve the early diagnosis rate and prediction accuracy of periodontal disease. Research on the development and application of artificial intelligence-based algorithms to improve the quality of such dental X-ray images is being widely conducted worldwide. Thus, the aim of this study was to design a super-resolution algorithm for predicting periodontal disease and to evaluate its applicability in dental X-ray images. The super-resolution algorithm was constructed based on the convolution layer and ReLU, and an image obtained by up-sampling a low-resolution image by 2 times was used as an input data. Also, 1,500 dental X-ray data used for deep learning training were used. Quantitative evaluation of images used root mean square error and structural similarity, which are factors that can measure similarity through comparison of two images. In addition, the recently developed no-reference based natural image quality evaluator and blind/referenceless image spatial quality evaluator were additionally analyzed. According to the results, we confirmed that the average similarity and no-reference-based evaluation values were improved by 1.86 and 2.14 times, respectively, compared to the existing bicubic-based upsampling method when the proposed method was used. In conclusion, the super-resolution algorithm for predicting periodontal disease proved useful in dental X-ray images, and it is expected to be highly applicable in various fields in the future.

An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

  • Kim, Hyun Jin;Kim, Hyun Nam;Raza, Hamid Saeed;Park, Han Beom;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.799-804
    • /
    • 2016
  • A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator (구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성)

  • Lee, Kyung Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.465-471
    • /
    • 2012
  • In this study, three dimensional X-ray dose distribution from dental X-ray generator system was measured by ALOKA PDM-117 dosimeter. The X-ray dose distribution will be change with XCP-DS FIT in oral shot, because the distance between X-ray generator and the dosimeter. The X-ray dose change affects on patient exposure and radiograph image quality. Therefore, it is important to obtain relation between the X-ray dose and the distance. The X-ray dose at the central position was decreased with increasing the distance. Furthermore, the dose at the edge of the X-ray flux was increased with increasing the distance. The increased dose affects on the patient radiation exposure. The present results will provide for good dental radiograph image and reducing radiation over-exposure on patient.

Feasibility study of insertable miniature x-ray source for dental imaging (치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구)

  • Cho, Sung-Ho;Kim, So-Yeong;An, So-Hyun;Lim, Soo-Mee;Lee, Re-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Conventional periphery radiography system has a various problem such as patient dose and the pain of X-ray examination. In this paper, to solve these problems, we suggested insertional miniature x-ray system and we verified the feasibility of this system. First, we performed the Geant4 x-ray simulation to design x-ray collimator and filter to use miniature x-ray tube and we decided optimized thickness of filter and collimator. Also, we measured x-ray spectrum using CdTe detector and PX4 module to verify simulation results. Also, we acquired teeth image of fabricated phantom using conventional dental x-ray and prosed miniature x-ray system. As a results, our system has good image quality as compared to those of conventional systems. Our evaluation of the proposed system indicates that it can be potentially very useful for dental imaging.

Digital X-ray Imaging in Dentistry (치과에서 디지털 x-선 영상의 이용)

  • Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.387-396
    • /
    • 1999
  • In dentistry. RadioVisioGraphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter. many types of direct digital radiographic system have been produced in the last decade. They are based either on charge-coupled device(CCD) or on storage phosphor technology. In addition. new types of digital radiographic system using amorphous selenium. image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose. image processing, computer storage. electronic transfer of images and so on. Image processing includes image enhancement. image reconstruction. digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system(IMACS) for dentomaxillofacial radiology was reported in 1992. IMACS in dental hospital has been increasing. Meanwhile. researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible. feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis. have been performed actively in the last decade. Further developments in digital radiographic imaging modalities. image transmission system. imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  • PDF

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

Multispectral X-ray imaging to distinguish among dental materials

  • Peter, Ann-Christin;Schnaubelt, Matthias;Gente, Michael
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.247-254
    • /
    • 2017
  • Purpose: Dual-energy X-ray imaging is widely used today in various areas of medicine and in other applications. However, no similar technique exists for dental applications. In this study, we propose a dual-energy technique for dental diagnoses based on voltage-switching. Materials and Methods: The method presented in this study allowed different groups of materials to be classified based on atomic number, thereby enabling two-dimensional images to be colorized. Computer simulations showed the feasibility of this approach. Using a number of different samples with typical biologic and synthetic dental materials, the technique was applied to radiographs acquired with a commercially available dental X-ray unit. Results: This technique provided a novel visual representation of the intraoral environment in three colors, and is of diagnostic value when compared to state-of-the-art grayscale images, since the oral cavity often contains multiple permanent foreign materials. Conclusion: This work developed a technique for two-dimensional dual-energy imaging in the context of dental applications and showed its feasibility with a commercial dental X-ray unit in simulation and experimental studies.

DEVELOPMENT OF A STORAGE SYSTEM FOR THE TREATMENT DATA AND IMAGE DATA IN DENTISTRY USING THE OPTICAL LASER CARD (광 카드를 이용한 치과 진료자료 및 영상자료 저장 system 개발)

  • Shin, Yong-Pil;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.110-140
    • /
    • 1998
  • One of the problems facing in all modern dental hospitals is the much efforts, manpower and space are needed to effectively sort and stack patients' charts of the various dental departments. In addition, the storage and prompt arrangement of x-ray films is also a problem. Therefore, if dental charts as well as films could be computerized, it would be easier to store and keep them; by data basing, many space, manpower and cost would be saved: data could also be effectively managed for the purpose of academic researches. This would be an epoch -making event in the development of dental hospital management. The purpose of this study is to develop a dental information processing program, that will be used to store dental treatment records and digital image data using a new record media, the optical card. The patients' charts from the dental hospital were selected. The treatment records of the chart were put into the treatment data -recording area of the program, and the digital images of various dental x-ray films were made with a scanner. These data were stored in the optical card and analyzed to get the following results: 1. In this program it is possible to put treatment records and image data into and out from the optical card, and it is impossible to correct and delete all data recorded on the optical card. 2. All data in the optical card system can be searched and analyzed on database. 3. The resolution of image data stored in optical card is above 5.9 lp/mm. 4, All data of dental charts used as samples, stored to optical cards, occupies average 14%, In conclusion, with the development of the storage system using the optical card, a dental patient's life-time treatment record can be stored in one optical card and used as a substitute for the dental chart.

  • PDF

3-Dimensional Dental Surgery System based on PC using anatomical landmarks (해부학적 계측점을 이용한 PC-기반3차원 치과수술 시스템)

  • 이경상;유선국;김형돈;배현수;김남현
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.139-148
    • /
    • 1999
  • In this paper, we designed the dental surgery system based on PC. This system predict post operated 3-dimensional image, So the patient has no need to take CT after surgery and expose his body to radiological damage. We predict the post operated skull from the patient's CT with pre and post cephalometry X-ray. Our novel procedures, to register X-ray and CT, are based on anatomical landmarks, singular value decomposition. And we display the predicted image 3-dimensionally by surface rendering. We verified this system by dry skull experiment and clinical experiment. When significance level is 0.05, there is on significance.

  • PDF