• Title/Summary/Keyword: Dental Image

Search Result 692, Processing Time 0.026 seconds

ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS (치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구)

  • Jung Young-Chul;Han Chong-Hyun;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

Application of MRI in dentistry: Radiation free image (치과 임상에서 MRI의 활용)

  • Jeon, Kug Jin
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.700-707
    • /
    • 2019
  • On account of the dentistry mainly deals with hard tissues such as teeth and bones, CBCT and CT are common imaging modality in clinics. Recently, insurance coverage of MRI has been extended to head and neck region. In addition, unlike CBCT or CT, ionizing radiation is not used, the demand for MRI is gradually increasing in dentistry. Even though, many dentists still think that MRI is a difficult diagnostic tool and they are not confident when to use it. Therefore, the objective of this manuscript is to help the dental clinicians to access easily on MRI by introducing the overview, application and precautions of this imaging tool.

  • PDF

The Effects of Service Level Provided by The Staffs in the Dental Clinic on The Purchasing Behavior of Customers in South Gyeongnam Province (경남지역 치과병.의원 직원들의 서비스제공수준이 고객의 구매행동에 미치는 영향)

  • Choi, Yu-Jin
    • The Korean Journal of Health Service Management
    • /
    • v.5 no.4
    • /
    • pp.149-159
    • /
    • 2011
  • The purpose of this research is to provide an available basis for marketing strategy by defining the cause-effect relation between the service level of staff members in dental clinic and purchasing behavior of the customers. This study was done in 10 days from November 2, 2009 to November 11, 2009 and the total 172 copies were used for the analysis. As a result of the correlation analysis, a significant positive correlation among all the measured variables was found. As a result of the structural model analysis, I found that the fair service among the variables of the service level significantly affects the building of relationship and the hospital image. The building of relationship and the hospital image significantly affect the positive oral spread. The building of relationship significantly affects the repurchase intentions but the hospital image does not affects the repurchase intentions. To sum up the result of this study, I found that the fair service and the building of relationship with patients are important variables in order to attract new patients and maintain existing customers. I recommend that the hospital continues to motivate staffs through internal marketing and conduct regular trainings. It is necessary to have patients satisfied with broadening responsibility and authority and set marketing strategy for the relationship with patients.

Clinical Usefulness of Ultrasonography in Oral and Maxillofacial Regions (구강악안면영역에서 초음파영상 진단)

  • Oh, Song Hee;Choi, Yong-Suk
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.690-699
    • /
    • 2019
  • Ultrasound sonography(US) is used to evaluate various diseases of maxillofacial region including salivary glands, soft tissue and jaw lesions because of easy accessibility and no hazard of ionizing radiation. Also, US can offer dynamic study showing real-time images during diagnostic or surgical procedure. US images provide accurate information about the internal features of lesions on the jaw prior to surgical treatment. Doppler images are used to visualize the vascular distribution of the lesions and to provide additional information to enhance diagnostic value. Nevertheless, the clinical application of US imaging is limited in the dental field. This is due to the lack of knowledge about the US image and the image characteristics of the anatomical structures. It is necessary to evaluate the diagnostic value of US and evaluate its usefulness by looking at clinical cases using US images. Therefore, US imaging may be recommended as an assistant image in evaluating jaw lesions. US images provided accurate information about the internal structure of lesions on the jaw prior to surgical treatment, and diagnostic value was enhanced by visualizing the vascular distribution of the lesion using doppler imaging.

  • PDF

Recognition of Health Care Workers for Dental Hygienists (치과위생사에 관한 일부 의료종사자의 인지도 조사)

  • Park, So-Young;Won, Young-Soon
    • The Korean Journal of Health Service Management
    • /
    • v.6 no.3
    • /
    • pp.127-140
    • /
    • 2012
  • This study involved an investigation of perception of dental hygienists based on a self-reported survey of a sample of 230health care personnel working at long-term care hospitals located in Gyeonggi Province, Korea. The primary objective was to provide basic data for establishing various policies related to building up a positive image of dental hygienists as a profession. The results were as follows. 79.1% of the respondents recognized dental hygienists as a profession. Among the titles for a dental hygienist, "teacher" was the most common with 47.4% of all. Female respondents and respondents who were able to discern between dental hygienists and nursing assistants were more likely to perceive dental hygienists positively than male respondents and ones who were not, respectively. Among social perceptions of dental hygienists was there a negative finding, that is, there was no appropriate title to address dental hygienists. This negative finding indicates that there is a vital need to enhance the perception of who are dental hygienists as a professionals level at the individual as well as institutional level.

A Study on Ultrasonic Image Diagnosis Methods of Tooth Defect with Phased-Array Techniques (위상배열기법을 이용한 치아결함 초음파이미지 진단기술개발)

  • Oh, Yun-Jung;Hwang, In-Nam;Park, Su-Jung;Im, Kwang-Hee;Cho, Hyun-Joon;Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.604-613
    • /
    • 2009
  • Recently, researches to develop phased array ultrasonic examination techniques are proceeded to diagnose dental caries and the status of surgical operation of dental implant. Sound field analysis of phased array ultrasonic transducers were carried out in order to characterizing the ultrasonic phased array beams. The sound field of ultrasonic radiation was calculated for the sample called "gypsum-improved stone" with the similar characteristics of dental materials. Industrial phased array ultrasonic devices were utilized for the insptriion of the artificial flaws machined in the gypsum-improved stone. Dental implants were made at the pig jaw bone and defect images were confirmed for the dental implants.

  • PDF

New evolution of cone-beam computed tomography in dentistry: Combining digital technologies

  • Jain, Supreet;Choudhary, Kartik;Nagi, Ravleen;Shukla, Stuti;Kaur, Navneet;Grover, Deepak
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.179-190
    • /
    • 2019
  • Panoramic radiographs and computed tomography (CT) play a paramount role in the accurate diagnosis, treatment planning, and prognostic evaluation of various complex dental pathologies. The advent of cone-beam computed tomography (CBCT) has revolutionized the practice of dentistry, and this technique is now considered the gold standard for imaging the oral and maxillofacial area due to its numerous advantages, including reductions in exposure time, radiation dose, and cost in comparison to other imaging modalities. This review highlights the broad use of CBCT in the dentomaxillofacial region, and also focuses on future software advancements that can further optimize CBCT imaging.

Comparison of Image reformation Using Personal Computer with Dentascan Program (CT scan의 다평면 재구성을 하는 Dentascan 프로그램과 개인용 컴퓨터를 이용한 영상재형성과의 비교에 관한 연구)

  • KIM Eun Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.7-16
    • /
    • 1997
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 5 mandibles of 5 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. Personal computer used for image reformation was PowerWave 6041120 (Power Computing Co, U.S.A.) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and Import ACCESS V1.H Designed Access Co., U.S.A.) for importing CT images and NIH Image 1.58 (NIH, U.S.A.) for image processing. Seven images were selected among the serial reconstructed cross-sectional images produced by Dentascan(DS group). Seven resliced cross-sectional images at the same position were obtained at the personal computer(PC group). Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformed cross-sectional images using Mac-compatible computer were highly correlated with those using workstation with Dentascan software(height : r²=0.999, p<0.001, width : r²=0.991, p<0.001). So, it is considered that we can use a personal computer with inexpensive softwares for the dental implant planning, instead of the expensive software and workstation.

  • PDF

3차원 두부방사선 규격사진 구현시 컴퓨터를 이용한 두부위치의 보정방법에 관한 연구

  • Choy, Kwang-Chul;Kim, Kyung-Ho;Kim, In-Dal
    • The Journal of the Korean dental association
    • /
    • v.36 no.2 s.345
    • /
    • pp.135-143
    • /
    • 1998
  • Cephalogram is one of the most important tool in researching growth and development of craniofacial area, orthodontic diagnosis and treatment planning. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. three dimensional high quality images can be obtained using computerized tomogram and have reported in literatures. Considering its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. construction of three dimensional image using principle of orientator can be obtained by biplanar stereoradiography. Theoretically two images, lateral and P-A can be used to construct three dimensional image provided that those are taken at same time by two different focal spots. As two images(lateral and P-A) obtained by conventional cephalogram have different head posture, those need compensation to construct three dimensional images. This study introduced principle of computerized head posture compensation and showed that conventional cephalogram could be used to construct three dimensional image and could be applied to routine orthodontic practice.

  • PDF