• Title/Summary/Keyword: Dental CT

Search Result 513, Processing Time 0.025 seconds

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering. Inc., Troy, USA) and ANSYS (Swanson Analysis Systems. Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Viva dent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition. Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

  • PDF

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering, Inc., Troy, USA) and ANSYS (Swanson Analysis Systems, Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Vivadent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition, Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

Alveolar ridge preservation using granulation tissue for esthetic implant restoration on maxillary anterior tooth (상악 전치부의 심미적 임플란트 수복을 위한 육아 조직(Granulation tissue)을 이용한 치조제 보존술)

  • Lee Chang Kyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.16-22
    • /
    • 2023
  • Esthetic factors are very important in the success of maxillary anterior implant restoration. However, achieving esthetic results is difficult, especially in cases where periodontitis has resulted in severe alveolar bone loss. In the case of maxillary anterior teeth, the alveolar ridge resorption that begins immediately after tooth extraction interferes with the esthetic implant restoration. Therefore immediate implant placement can be performed to minimize the alveolar ridge resorption. However, in severe bone loss cases, immediate implant placement could result in esthetic failure, and this result might cause irreparable problems. We can also perform alveolar ridge preservation and then place implants later. On JCP published in 2019, there is the consensus of European academy of periodontology on the extraction socket management and the timing of implant placement. This consensus states that alveolar ridge preservation should be considered when there is severe labial bone loss in an esthetically important area such as maxillary anterior region. On performing the alveolar ridge preservation, we cannot obtain the primary wound closure, so secondary wound healing is induced with open membrane technique or soft tissue grafting should be performed for primary wound closure. However, the secondary wound healing can have a negative impact on bone regeneration, and soft tissue grafting such as FGG or CT graft can be burdensome for both patients and dentists. On the other hand, by using the granulation tissue in the extraction socket, primary closure can be achieved without soft tissue grafting. Also some studies have shown that granulation tissue in periodontal defects contains stem cells that may help in tissue regeneration. Based on this, implant restorations were performed on maxillary anterior teeth with severe alveolar bone loss by alveolar ridge preservation using granulation tissue. In spite of the severe bone defect of the extraction socket, relatively esthetic results could be obtained in implant restorations.

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

Three Dimensional Study of Miniscrew about Installation Area and Angle (미니스크류 식립 각도 및 부위에 대한 3차원적 연구)

  • Jo, Hee-Sang;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Minimizing damage to anatomical structure is a prerequisite for skeletal anchorage system to install a miniscrew. This research has focused on evaluating the stability and safety of installation in the maxillary molar buccal area, in which most miniscrews are installed clinically and initial fixation is weak. CT (computerized tomography)images were taken for surveying the possibility of damaging to adjucent teeth in accordance with installation angle. If we install a mini-screw($1.2{\times}6.0mm$) in the maxillary molar buccal area, it would be located generally in the 5~8mm upper of CEJ and 3~5mm inner of the cortical bone surface. We has measured the space between roots And comparison has been made for gender and the space between roots in accordance with the 3 different angles of installation(30 degree, 40 degree, 60 degree) in 3 categories. Category 1 : between 1st molar and 2nd molar Category 2 : between 1st molar and 2nd premolar Category 3 : between 1st premolar and 2nd premolar The result are as follow; 1. The space for category 1 was significantly small. 2. For the installation angle, it was safer to install with steeper angle in category 1 and category 2, but not in category 3. According to these results, the installation a miniscrew in category 2, 3 is safer than in category 1. And it is safer to install with steeper angle in category 1 and category 2.

The Effects of calcium sulfate on healing of 1-wall intrabony defects in dogs (성견의 1면 골내낭에 calcium sulfate 이식이 치주조직 치유에 미치는 영향)

  • Suh, Hye-Yuhn;Choi, Seong-Ho;Moon, Ik-Sang;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.2
    • /
    • pp.363-377
    • /
    • 1997
  • The main goal of periodontal therapy is the regeneration of periodontal tissue which has been lost due to destructive periodontal diseases. Although conventional forms of periodontal therapy show sound clinical results, the healing results in long junctional epithelium. There have been numerous materials and surgical techniques developed for new attachment and bone regeneration. Bone grafts can be catagorized into: autografts, allografts, xenografts and bone substitutes. Synthetic bone substitute materials include hydroxyapatite, tricalcium phosphate, calcium carbonate, and Plaster of Paris. Calcium sulfate has found its use in dental practice for the last 30 years. Recent animal studies suggest that periodontal regeneration in 3 wall intrabony defect may be enhanced by the presence of calcium sulfate. And it is well known that 2 wall & 1 wall defect have less osteogenic potential, So we need to study the effect of calcium sulfate in 1 wall intrabony defect in dogs. The present study evaluates the effects of calcium sulfate on the epithelial migration, alveolar bone regeneration and cementum formation in intrabony defects of dogs. Four millimeter-deep one-wall intrabony defects were surgically created in the mesial aspect of anterior teeth and mesial & distal aspects of premolars. The test group received calcium sulfate grafts with a flap procedure. The control underwent flap procedure only. Histologic analysis following 8 weeks of healing revealed the following results: 1. The lengths of junctional epithelium were: 2.52mm in the control, and 1.89mm in the test group. There was no statistical significance between the two groups. 2. Alveolar bone formation were: 0.61mm in the control, and 1.88mm in the test group. There was a statistically significant difference between the two groups (p<0.05). 3. Cementum formations were: l.lmm in the control, and 2.46mm in the test group. There was a statistically significant difference between the two groups (p<0.05). 4. The length of CT adhesion were: O.97mm in the control, and 0.17mm in the test group. There was no statistically significant differences between the two groups These results suggest that the use of calcium sulfate in intrabony defects has little effect on junctional epithelium migration, but has significant effects on new bone and new cementum formations.

  • PDF

Randomized clinical trial on the efficacy of Escherichia coli-derived rhBMP-2 with ${\beta}$-TCP/HA in extraction socket

  • Huh, Jung-Bo;Lee, Hyo-Jung;Jang, Ji-Woong;Kim, Myung-Jin;Yun, Pil-Young;Kim, Su-Hong;Choi, Kyung-Hee;Kim, Young-Kyun;Cho, Kyoo-Sung;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.161-165
    • /
    • 2011
  • PURPOSE. This randomized clinical trial was conducted to assess the safety and effectiveness of the ErhBMP-2 in alveolar bone regeneration as well as preservation of the ${\beta}$-TCP bone graft material that contains ErhBMP-2. MATERIALS AND METHODS. This study involved 72 patients at the 3 study centers. The patients, who were divided into 2 groups: the experiment group who had ErhBMP-2 coated TCP/HA and the control group who had TCP/HA graft material alone transplanted immediately after tooth extraction. CT was taken before and 3 months after the transplantation and healing status was compared between the two groups. The efficacy endpoints that were used to measure the degree of bone induction included alveolar bone height and 3 measurements of bone width. The paired t test was used to determine the significance of the changes (P<.05). RESULTS. Changes in alveolar bone height were $-1.087{\pm}1.413$ mm in the control group and $-.059{\pm}0.960$ mm in the experimental group (P<.01). At 25% extraction socket length [ESL], the changes were $0.006{\pm}1.149$ mm in the control group and $1.279{\pm}1.387$ mm in the experimental group. At 50% ESL, the changes were $0.542{\pm}1.157$ mm and $1.239{\pm}1.249$ mm, respectively (P<.01 for 25% ESL, and P<.05 for 50% ESL). During the experiment, no adverse reactions to the graft material were observed. CONCLUSION. ErhBMP-2 coated ${\beta}$-TCP/HA were found to be more effective in preserving alveolar bone than conventional ${\beta}$-TCP/HA alloplastic bone graft materials.