• Title/Summary/Keyword: Dental Base Metal Alloys

Search Result 20, Processing Time 0.02 seconds

Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature

  • Al Jabbari, Youssef S.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2014
  • Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.

The Comparative Study on the Castability to the Frequency of Reuse with Precious Metal Alloys and Base Metal Alloys widely used in the Production of Partial Denture (국부의치(局部義齒) 제작(製作)에 사용(使用)되는 귀금속합금(貴金屬合金)과 비귀금속합금(非貴金屬合金)의 재(再) 사용(使用) 횟수에 따른 주조성(鑄造性) 비교(比較) 연구(硏究))

  • Chung, Kyung-Pung;Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.10-25
    • /
    • 1995
  • The purpose of this study is to get the difference of the castability in the production of partial denture between Precious Metal Alloys and Base Metal Alloys accompanied with the frequency of reuse. As materials for an experiment, we selected Baker-444 and Soo-444 and Soo-sung as Precious Metal Alloys, New Crown and Chrome Cobalt as Base Metal Alloys. And we tired to case all of them seven times. The experimental results were as follows : 1) In the probability of segments, Baker-444 showed 100$\pm$0.00%, Soo-sung 97.24$\pm$1.58%, New Crown 95.63$\pm$4.28%, and Chrome Cobalt 91.03$\pm$7.76%. Consequently, Precious Metal Alloys were decidely superior to Base Metal Alloys in the castability. 2) In the view of the acheived result, burn-out temperature and smocking time had greatly affected the castability. 3) After casting, Precious Metal Alloys were much less than Base Metal Alloys in the quantity of consumption. It made much difference from the the compiled stastics(p<0.01)

  • PDF

CYTOTOXICITY OF DENIAL CAST BASE METAL ALLOYS ON HUMAN ORAL KERATINOCYTES (구강점막 상피세포에 대한 치과 주조용 비귀금속 합금의 세포독성)

  • Choi, Young-Jin;Yook, Jong-In;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.717-729
    • /
    • 1999
  • Although many studies on the cytotoxicity of the dental cast base metal alloys and their components have been carried out, the results are rather conflicting because of the different type of cells used and the various experimental procedures taken. Recently a number of scientists have claimed that it would be preferable to focus on the use of cells from relevant specific location of the human bodies. Consequently, the primary cultured oral keratinocyte derived from oral mucous along with nickel chloride and several of widely used dental cast base metal alloys(two Ni-Cr alloys and one Co-Cr alloy)in domestic were selected for this study, from which 1) The amounts of released metal ions were determined using atomic absorption spectrometry, 2) The cytotoxicity of nickel chloride and dental cast base metal alloys was evaluated via MTT assay, and finally, 3) The amounts of released metal ions and the cytotoxicity of nickel chloride were correlated with the cytotoxicity of dental cast base metal alloys And, the results were summarized as follows; 1. Nickel ion from Ni-Cr alloys and Cobalt ion from Co-Cr alloys resulted in maximum releasing rate during first 2h hours, followed by a decrease in releasing rate with time. Chromium ion were found to be minimal in all alloys. 2. In cytotoxic test. with $40{\mu}M,\;80{\mu}M$ of nickel chloride, there were observed an increase in the relative cell number compared to control samples after 24 hours. With $160{\mu}M$, there was found to be no difference in the relative cell number with control, except that 48 hour showed a increase in relative cell number. With $320{\mu}M$, the relative cell number remained constant and decreased after 48 hours, and with $640{\mu}M$, a continuing decrease in relative cell number was observed throughout test period. 3 The sensitivity of primary cultured oral epithelium to nickel was lower compared to the cells used in other studies. 4. CB-80 Soft and Regalloy showed no cytotoxicity to primary cultured oral epithelium and New crown resulted in a slight cytotoxicity. In conclusion, it was shown that the primary cultured oral keratinocytes could be applied successfully as testing cells in cytotoxicity test. Futhermore, the dental cast base metal alloys used in this study were found to be biocompatible.

  • PDF

An Experimental Study on The Cytotoxicity of Dental Base Metal Alleys by Extraction Method (용출법을 이용한 치과용 base metal alloy의 세포독성에 관한 실험적 연구)

  • Yoon, Min-Eui;Jin, Tai-Ho;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.123-130
    • /
    • 1989
  • In order to investigate the biocompatibility of base metal alloys in dental prosthesis, the 3 types of Ni-Cr alloys and the 3 types of Co-Cr alloys were collected and each alloy was extracted in the culture medium. L-cells derived from the subcutaneous tissue of mouse and extracted medium were cultivated. The relative growth rate of L-cells in the tissue culture was calculated with N-R assay. The obtained results were as follows: 1. In the case of the Co-Cr alloys tested, its cytotoxicity proved weak. 2. In the case of the Ni-Cr alloys tested, there was no significant degree of cytotoxicity, especially 25% Victory was proved noncytotoxicity.

  • PDF

Corrosion of the non-beryllium dental casting Ni-Cr alloys for the denture base framework metal and the porcelain-fused-to-metal crown (베릴륨 불포함 치과 주조용 니켈-크롬 합금 중 금속의치상용 합금과 금속소부도재관용 합금의 부식에 관한연구)

  • Kim, Hong-Sik;Song, Jae-Sang;Park, Soo-Chul
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.337-344
    • /
    • 2012
  • Purpose: This study examined the corrosion level by alloy type and pH, and used the corrosion levels as the dental health data. The study utilized one Ni-Cr alloy for the full and removable partial denture metal frameworks and two Ni-Cr alloys for porcelain-fused-to-metal crown, among the non-beryllium dental casting non-precious Ni-Cr alloys. Methods: The alloy specimens were manufactured in $10cm^2$ and stored in the corrosive solution(pH 2.2-4.4) in the electrical water bath($37^{\circ}C$) for seven days. Afterwards, the metal ions were quantitatively analyzed using the ICP. Results: Of the three metal alloys, Bellabond-Plus$^{(R)}$alloy and SOLIBOND N$^{(R)}$alloy, with 22% or higher chrome chemical contents, had higher corrosion resistance than Jdium-100$^{(R)}$alloy with 20% chrome chemical content. In all three alloys, the corrosion of Ni was highest, and metal ion corrosion was higher in the pH 2.2 corrosive solution. Conclusion: Although Ni-Cr alloy was not very corrosive, a Ni-allergic patient should not have Ni-Cr alloy prosthesis. The Ni-Cr alloy for porcelain-fused-to-metal crown should be designed for the dental porcelain to cover the whole crown.

A STUDY ON THE CASTABILITY OF BASE METAL ALLOYS WHICH ARE SPRUE LENGTH AN CASTING PRESSURE (Sprue의 길이와 주조압이 비귀금속 합금의 주조성에 미치는 영향에 관한 연구)

  • Choi, Seog-Soon
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.89-93
    • /
    • 1989
  • The purpose of this study was to evaluate the effect of sprue length and casting pressure on the relative castability of the base metal alloys, commonly used to make porcelain metal restoration. Samples of total 30 were constucted and devided into 6 groups according to three variables (low, medium, high). The total number of complety cast squares were counted, verified and recorded. The results of this 1. main effect of casting pressure was statistically significant.(P<0.05). 2. main effect of sprue length was not statistically significant.

  • PDF

Scanning Electron Micrographic Study on the Etched Surface of Base Metal Alloys for Dental Restorations (치과용 비귀금속합금의 식각표면에 대한 주사전자현미경적 연구)

  • Chung, Hun-Young;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.83-95
    • /
    • 1985
  • The purpose of this study was to evaluate microstructures on the etched surface of 11 base metal alloys for dental restorations and to observe the relationship between the etching pattern and beryllium. For this purpose, the following experiments were done; 11 base metal alloys were etched in (1) 10% $H_2SO_4$, (2) 10% $H_2SO_4$, 9 parts+methanol 1 part (3) Conc. $HNO_3$ 25%+glacial acetic acid 25%+$H_2O$ 50% (4) Conc. $HNO_3$ 5% (5) 2% glacial acetic acid added to Conc. $HNO_3$ 1% solution, with their etching conditions varied. Etched surface of alloys were examined under the scanning electron microscope. Results were as follows; 1. Almost all of Ni-Cr-Be alloys showed gooed etchd surface in $H_2SO_4$, solution, while some of those alloys which contains no beryllium showed good etched surface in $HNO_3$ solution. 2. Main components of etching solution can vary etching pattern of alloys. 3. Gamma prime phase relief, which can be found in all Ni-Cr-Be alloys, can't be found in any alloy that contains no beryllium.

  • PDF

Microstructure and Mechanical Properties of Ni-Cr-Mo Based Dental Cast Iron for Porcelain-Fused-to-Metal Firing (도재소부용 Ni-Cr-Mo계 치과용 합금의 미세조직 및 기계적성질)

  • Choi, D.C.
    • Journal of Korea Foundry Society
    • /
    • v.27 no.3
    • /
    • pp.120-125
    • /
    • 2007
  • The microstructure, mechanical properties and melting range of Ni-Cr-Mo based alloys were investigated to develop Be-free Ni-Cr-Mo base dental alloys for Porcelain-Fused-to-Metal Firing(PFM). All as-cast alloys showed dendritic structure. Rockwell hardness of 20Cr7Mo was increased with addition of Si and Ti. On the contrary, it was decreased with addition of Co. The duplex alloying elemental addition such as 3Co + xTi, 2Si + xCo and 2Si + xTi to 20Cr7Mo resulted in much increase of hardness. Rockwell hardness and compressive strength for 20Cr3CoSiTi or 17Cr6CoSiTi alloy that add Si-Ti had similar values compared to the commercial alloys. Melting range for 20Cr3CoSiTi and 17Cr6CoSiTi alloy that add Si-Ti showed similar or lower than commercial alloys. In conclusion, 20Cr3CoSiTi and 17Cr6CoSiTi alloys can be applied for commercial use.

The Etched Surface of the Repeatedly Cast Dental Base Metal Alloy (반복 사용된 치과용 비귀금속에 의한 주조체의 식각표면에 대한 연구)

  • Lee, Sun-Hyung
    • The Journal of the Korean dental association
    • /
    • v.23 no.7 s.194
    • /
    • pp.577-583
    • /
    • 1985
  • The purpose of this investigation was to evaluate scanning electron micrographs of repeatedly cast base metal alloy. For this study two Ni-Cr-Be alloys were used; Rexillium III and Verabond. They were repeatedly cast without addition o new alloy melting with an electric resistant furnace (Castron 8, Yoshida dental equipment Mfg.Co.). They were etched with 10% H₂SO₄ Sol. at 300mA/㎠ for 3 minutes with the use of metal etching unit Oxyetch (OXY dental product Inc.), and ultrasonic cleaning in 18% HC1 Sol. was done. Etched surfaces were examined under a SEM at x 200 and x 750. The surfaces are shown in legends.

  • PDF