• 제목/요약/키워드: Dental Anesthesia device

검색결과 30건 처리시간 0.019초

Effect of vibration during local anesthesia administration on pain, anxiety, and behavior of pediatric patients aged 6-11 years: A crossover split-mouth study

  • Hegde, Kuthpady Manasa;Neeraja, R;Srinivasan, Ila;Murali Krishna, DR;Melwani, Anjana;Radhakrishna, Sreeraksha
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제19권3호
    • /
    • pp.143-149
    • /
    • 2019
  • Background: Uncooperative behavior of children due to dental anxiety may interfere with the effective delivery of dental care and compromise the quality of treatment provided. Injection of local anesthesia is one of the most anxiety-inducing stimuli in pediatric dentistry. This study aimed to compare the efficacy of a child-friendly device, having a combined effect of vibration and distraction, with the conventional method of injection on pain, anxiety, and behavior of pediatric patients aged 6-11 years. Methods: This randomized, crossover, split-mouth study included 30 children requiring a bilateral inferior alveolar nerve block. The children were equally divided into two groups: group 1, aged 6-8 and group 2, aged 9-11 years. All children were injected with anesthesia using the conventional and device method in two separate sessions. They were assessed for anxiety by measuring the pulse rate before and during the administration of local anesthesia. Behavior was assessed using Faces, Legs, Activity, Cry, Consolability (FLACC) scale, and the child's experience while receiving anesthesia was assessed using the Wong Bakers Pain Rating Scale. Results: Results showed that the children who received local anesthesia using the device method had a lower mean pulse rate, FLACC scores, and pain rating scores than those who received local anesthesia using the conventional method. Conclusion: The device method was more effective than the conventional method in managing pain, anxiety, and behavior of patients aged 6-11 years. The device is a cost effective, simple, and child-friendly product for administrating local anesthesia in pediatric patients.

Computer-controlled local anesthetic delivery for painless anesthesia: a literature review

  • Kwak, Eun-Jung;Pang, Nan-Sim;Cho, Jin-Hyung;Jung, Bock-Young;Kim, Kee-Deog;Park, Wonse
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제16권2호
    • /
    • pp.81-88
    • /
    • 2016
  • Local anesthesia is administered to reduce pain during dental treatments, but may itself cause pain and contribute to increased dental fear. Computer-controlled local anesthetic delivery (CCLAD) is one the method to reduce patient pain during local anesthesia; it is a device that slowly administers anesthetics by using a computerized device to control the injection speed. This literature review aims to provide an objective assessment of the usefulness of CCLAD for controlling pain by reviewing papers published to date that have used CCLAD.

Computerized intraligamental anesthesia in children: A review of clinical considerations

  • Baghlaf, Khlood;Elashiry, Eman;Alamoudi, Najlaa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제18권4호
    • /
    • pp.197-204
    • /
    • 2018
  • Pain control by means of local anesthesia is an intrinsic part of clinical practice in dentistry. Several studies evaluated intraligamental anesthesia using a computer-controlled anesthetic device in children. There is a need to provide a clinical guide for the use of computerized intraligamental anesthesia in children. Intraligamental anesthesia using a computer-controlled anesthetic device was found to cause significantly lower pain perception scores and lower pain-related behavior than traditional techniques. This device proven to be effective in restorative and pulp treatment in children; however, its effectiveness in primary teeth extraction is controversial. It is important to withdraw recommendations necessity of future studies concerning the side effects of computerized intraligamental anesthesia in children. The present study aims to review different clinical aspects of computerized intraligamental anesthesia in children along with the side-effects, type of local anesthesia and postoperative pain of this technique. This study provides dentists with a clinical guide for the use of computerized intraligamental anesthesia.

Efficacy of computer-controlled local anesthesia delivery system on pain in dental anesthesia: a systematic review of randomized clinical trials

  • Maryam Altuhafy;Gurinder Singh Sodhi;Junad Khan
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제24권4호
    • /
    • pp.245-264
    • /
    • 2024
  • Computer-controlled local anesthesia delivery (CCLAD) is an innovative electronic injection device that represents a cutting-edge approach to dental anesthesia. This system is promising for painless anesthesia using controlled anesthetic injections. This review aimed to compare the discomfort experienced by patients during local anesthesia using a traditional syringe and the CCLAD system and evaluate the potential of the CCLAD system as a painless dental anesthesia solution. The inclusion criteria for this study were based on the recommendations of the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The study population, including children and adults, underwent dental anesthesia using the CCLAD system, ensuring a comprehensive and representative sample that instills confidence in the validity of the results. Fourteen clinical trials were included in the analysis after they fulfilled the eligibility criteria. We found that using computer-assisted anesthetic equipment not only led to a significantly lower pain perception score, but also had a profound positive impact on patient behavior. Patients using the CCLAD device exhibited more cooperative and helpful conduct, indicating the system's effectiveness in improving patient comfort and experience and reassuring the audience about its positive impact. In conclusion, using a computer-assisted anesthetic device such as the CCLAD system significantly reduced pain perception scores and improved patient behavior, making them more cooperative and helpful. These findings offer hope for pediatric dentistry and apprehensive adult patients, suggesting a more comfortable and less daunting dental experience with the CCLAD system.

국소마취시 통증을 줄이기 위한 기기들 (Devices for reducing Pain during local anesthesia)

  • 박원서
    • 대한치과의사협회지
    • /
    • 제56권1호
    • /
    • pp.58-65
    • /
    • 2018
  • Dental local anesthesia is important procedure for the elimination of pain during dental treatment. However, the pain during local anesthesia is one of the main source of fear to the patients. The cause of pain during dental local anesthesia includes soft tissue damage during penetration of the oral mucosa, pressure from the spread of the anesthetic solution, temperature of anesthetic solution, low pH of anesthetic solution, and the characteristics of the drug. Several concepts and devices introduced to date to reduce the pain during local anesthesia for dental treatment. In this report, devices that can reduce the pain during local anesthesia will be discussed.

  • PDF

Novel dental anesthetic and associated devices: a scoping review

  • Kyung Hyuk Min;Zac Morse
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제24권3호
    • /
    • pp.161-171
    • /
    • 2024
  • The efficient management of pain and discomfort is essential for successful dental treatment and patient compliance. Dental professionals are commonly evaluated for their ability to perform treatment with minimal patient discomfort. Despite advancements in traditional local dental anesthesia techniques, the pain and discomfort associated with injections remain a concern. This scoping review aims to provide a comprehensive overview of the literature on novel dental anesthetics and associated devices designed to alleviate pain and discomfort during dental procedures. The Joanna Briggs Institute and the Preferred Reporting Items for Systematic reviews and Meta-Analyses Extension for Scoping Reviews guidelines were used to prepare the review. Six databases and two sources of gray literature were searched. This review analyzed 107 sources from 1994 to 2023. Local anesthesia devices were grouped into computer-controlled local anesthetic delivery (CCLAD) systems, intraosseous anesthesia (IOA), vibratory stimulation devices, and electronic dental anesthesia (EDA). CCLAD systems, particularly the Wand and Single-Tooth Anesthesia, have been the most researched, with mixed results regarding their effectiveness in reducing pain during needle insertion compared to traditional syringes. However, CCLAD systems often demonstrated efficacy in reducing pain during anesthetic deposition, especially during palatal injections. Limited studies on IOA devices have reported effective pain alleviation. Vibrating devices have shown inconsistent results in terms of pain reduction, with some studies suggesting their primary benefit is during needle insertion rather than during the administration phase. EDA devices are effective in reducing discomfort but have found limited applicability. These findings suggest that the CCLAD systems reduce injection pain and discomfort. However, the evidence for other devices is limited and inconsistent. The development and research of innovative technologies for reducing dental pain and anxiety provides opportunities for interdisciplinary collaboration and improved patient care in dental practice.

Comparative evaluation of efficacy of external vibrating device and counterstimulation on child's dental anxiety and pain perception during local anesthetic administration: a clinical trial

  • Sahithi, Varada;Saikiran, Kanamarlapudi Venkata;Nunna, Mahesh;Elicherla, Sainath Reddy;Challa, Ramasubba Reddy;Nuvvula, Sivakumar
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권4호
    • /
    • pp.345-355
    • /
    • 2021
  • Background: This study aimed to evaluate the efficacy of external vibrating devices and counterstimulation on a child's dental anxiety, apprehension, and pain perception during local anesthetic administration. Methods: This was a prospective, randomized, parallel-arm, single-blinded interventional, clinical trial. One hundred children aged 4-11 years, requiring pulp therapy or extraction under local anesthesia (LA), were recruited and allocated equally into two groups (1:1) based on the interventions used: Group BD (n = 50) received vibration using a Buzzy® device {MMJ Labs, Atlanta, GE, USA} as a behavior guidance technique; Group CS (n = 50) received counterstimulation for the same technique. Anxiety levels [Venham's Clinical Anxiety Rating Scale (VCARS), Venham Picture Test (VPT), Pulse oximeter {Gibson, Fingertip Pulse Oximeter}, Beijing, China)] were assessed before, during, and after LA administration, while pain perception [Wong-Baker Faces Pain Rating Scale (WBFPS), Visual Analogue Scale (VAS)] was evaluated immediately after injection. Statistical analysis was performed using the Student's t-test to assess the mean difference between the two groups and the repeated measures ANOVA for testing the mean difference in the pulse rates. Statistical significance was set at P < 0.05. Results: Significant differences in mean pulse rate values were observed in both groups. In contrast, the children in the BD group had higher diminution (P < 0.05), whereas the mean VCARS and VPT scores were conspicuous (P < 0.05). Based on the mean WBFPS and VAS scores, delayed pain perception after LA injection was more prominent in the BD group than in the CS group. Conclusion: External vibration using a Buzzy® device is comparatively better than counterstimulation in alleviating needle-associated anxiety in children requiring extraction and pulpectomy.

Evaluation of dental status using a questionnaire before administration of general anesthesia for the prevention of dental injuries

  • Kyungjin Lee;Seo-Yul Kim;Kyeong-Mee Park;Sujin Yang;Kee-Deog Kim;Wonse Park
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권1호
    • /
    • pp.9-17
    • /
    • 2023
  • Background: Dental evaluation and protection are important for preventing traumatic dental injuries when patients are under general anesthesia. The objective of the present study was to develop a questionnaire based on dentition-related risk factors that could serve as a valuable tool for dental evaluation and documentation. Methods: We developed a questionnaire for dental evaluation before administration of general anesthesia, investigated the association between patient-and-dentist responses and mouthguard fabrication, and assessed response agreement between 100 patients. Results: Protective mouthguards were fabricated for 27 patients who were identified as having a high risk of dental injury. There was a strong association between dentists' responses and mouthguard fabrication, depending on the general oral health status, use of ceramic prosthesis, presence of masticatory pain related to periodontal diseases, gingival edema, and implants (P < 0.05). Response agreement between patients and dentists for items related to dental pain, loss of dental pulp vitality, root canal therapy, dental trauma, aesthetic prosthesis, tooth mobility, and implant prosthesis was high (Cohen's kappa coefficient κ ≥ 0.6). Conclusions: A high agreement was observed between patient-dentist responses and a strong association with mouthguard fabrication for items pertaining to ceramic prosthesis, masticatory pain, and dental implants. Patients with a "yes" response to these items are recommended to undergo a dental evaluation and use a dental protective device while under general anesthesia.

Effect of audio distraction with thermomechanical stimulation on pain perception for inferior alveolar nerve block in children: a randomized clinical trial

  • Devendra Nagpal;Dharanshi Viral Amlani;Pooja Rathi;Kavita Hotwani;Prabhat Singh;Gagandeep Lamba
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권6호
    • /
    • pp.327-335
    • /
    • 2023
  • Background: Pain control is a crucial aspect of pediatric dentistry for patient management. Thermo-mechanical devices (BuzzyTM Pain Care Labs, USA) work on the concept of vibration and cooling and have shown promising results in pain control during local anesthesia in pediatric dentistry. On the other hand, audio distraction has also been used for pain management. The amount of pain endured is determined by the patient's perception and attentiveness. Thus, if audio function is added to the thermomechanical device it might increase its efficiency. Hence, the present study aimed to compare pain on injection using a thermo-mechanical device with and without audio during inferior alveolar nerve block (IANB) injection in children aged 5-10 years old. Methods: Twenty-eight children aged between 5 and 10 indicated for IANB were included in this randomized study. Children who were undergoing the dental procedure were divided into 2 groups, with 14 children in each group. The study group was the thermo-mechanical device with audio distraction; the control group was the thermo-mechanical device without audio distraction. IANB was administered. Subjective pain evaluation was performed using the Wong-Baker Faces Pain Rating Scale (WBFPR) and objective pain evaluation was done using the Faces, Leg, Activity, Consolability, Cry (FLACC) scale. Results: The outcome depicted a significant reduction in pain on injection for both objective and subjective evaluations in the thermo-mechanical device with an audio distraction group. Conclusions: Less pain on injection was observed, when a thermo-mechanical device was used with audio distraction for IANB procedures.

소아에서의 치과전기마취 : 증례보고 (DENTAL ELECTRONIC ANESTHESIA IN CHILDREN : A CASE REPORT)

  • 이은영;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제21권2호
    • /
    • pp.525-532
    • /
    • 1994
  • The purpose of this report was to evaluate the effect of Dental Electronic Anesthesia on pain inhibition for clinical use. The subject for this study were 30 children whose Frankl behavioral rate is positive. The subjects was divided into two groups, the first group described by control group and the second group described by experimental group anesthetized with Dental Electronic Anesthetic device. And then three kind of treatments were done : extraction of deciduous teeth, application of rubber dam, cavity preparation for preventive resin restoration. 3M Dental Electronic Anesthesia System was used for this study : its electric impulse stimulate the skin surface by external electrode pads. The results were as follows. 1. Degree of the pain & the apprehension decreased in experimental group. 2. Degree of the pain & the apprehension showed statistical differences among three treatments procedures in the control group but, not showed statistical differences in the experimental group.

  • PDF