• Title/Summary/Keyword: Density Profile Measurement

Search Result 62, Processing Time 0.018 seconds

Ultrashort Pulse Reflectometry for the Measurement of Electron Density Profiles (전자 밀도 분포 측정을 위한 극단 펄스 레플렉토메터리)

  • 노영수
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.8-14
    • /
    • 2004
  • An O-mode Ultrashort Pulse Reflectometry (USPR) system has been designed and developed for the measurement of electron density profiles on the Sustained Spheromak Physics Experiment (SSPX) spheromak. In the original design of SSPX, peak densities were envisioned to be in the range of 0.5-3${\times}$10$^{14}$ cm$^{-3}$ . The total duration of formation and sustained discharges is typically ∼2 msec. Moreover, diagnostic access on SSPX is severely restricted. Such high density and short duration plasmas coupled with stringent diagnostic access are quite challenging for conventional reflectometer systems. In USPR, the SSPX diagnostic requirements have been successfully satisfied by employing up-converting mixers and monostatic horn/waveguide configuration. As a result, the USPR system has proven its applicability for the density measurement of a future fusion device. In the density profile measurements, the USPR system is capable of routinely generating density profiles with a temporal resolution of 57 $\mu$s. This paper presents details regarding the USPR fundamental principles, associated subsystems and laboratory tests as well as the experimental results obtained on SSPX

Development of Profilometer for Profile Measurement and Severity Analysis of Unpaved Test Courses (비포장 시험로의 노면 굴곡 측정 및 가혹도 분석을 위한 노면굴곡측정장비 개발)

  • Yang, Jin-Saeng;Goo, Sang-Hwa;Bae, Cheol-Hoon;Lee, Sang-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.37-46
    • /
    • 2007
  • The vibration environment essentially companied by vehicle operation on the ground is determined by the shape of road surface, which is called profile. This paper focuses on development of a profile and severity measurement system for unpaved test courses. In general, the profile and severity of unpaved road is an important issue in the reliability of endurance test. In order to measure unpaved road profile and severity, it is necessary to develop a profilometer system. The developed profilometer system is composed of data processing computer, power unit, air compressor and sensors(encoder, vertical gyro and laser displacement) This paper presents the measuring system configuration, measurement principle of road profile and analysis method of road characteristics used at CPG(Changwon Proving Ground) for this purpose.

Feasibility Study of Gamma Ray Transmission Technique in Distillation Column Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 감마선 투과계측 증류탑 진단기술의 타당성 연구)

  • Moon, Jinho;Kim, Jongbum;Park, Jang Guen;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.115-119
    • /
    • 2013
  • The density profile measurement technology by gamma transmission has been widely used to diagnose processes in the field of refinery and petrochemical industry. This technology can reveal a clue and position of abnormal phenomenon of industrial processes during their operation. In this paper, the feasibility of the gamma transmission technology for detecting changes in the amount of fluid in a distillation column was evaluated by using Monte Carlo simulations. The simulations assumed that $^{60}Co$ (1.17, 1.33 MeV) sources and NaI (Tl) detectors (${\Phi}5{\times}5cm$) are located in opposite sides of a column and it concurrently moves in vertical direction. To determine the dependency of a spatial resolution on aperture size of a collimator, the simulation model for a tray in a column were simulated with the aperture sizes of 1 and 2 cm. The thickness of the high density area including a tray and fluid was 7.6 cm in the simulation. The spatial resolution of the tray was 8.2 and 8.5 cm, respectively. As a result, it was revealed that the conventional density profile measurement technique is not able to show the deviation of liquid level on a tray in a column.

DEVELOPMENT OF IONOSPHERIC TOMOGRAPHY MODEL USING GPS (GPS를 이용한 전리층 토모그래피 모델 개발)

  • Choi Byung-Kyu;Park Jong-Uk;Lee Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.3
    • /
    • pp.237-244
    • /
    • 2006
  • We produced the electron density distribution in the ionosphere over South Korea using the data from nine permanent GPS (Global Positioning System) stations which have been operated by KASI (Korea Astronomy and Space Science Institute). The dual-frequency GPS receiver data was used to precisely estimate the electron density in the ionosphere and we obtained the precise electron density profile based on two-dimensional TEC (Total Electron Contents). We applied ART (Algebraic Reconstruction Technique), which is one of the most commonly used algorithms to develop the tomography model. This paper presented the electron density distribution over South Korea with time. We compared with the electron density profiles derived from the GPS tomography reconstruction, Ionosonde measurement data obtained by observations, and the IRI-2001 values. As a result, the electron density profile by GPS reconstruction was in excellent agreement with the electron density profile obtained by Ionosonde measurement data.

Measurement of Dispersion Relation of Plasma Wave (플라즈마 파동의 분산관계 측정에 관한 연구)

  • Jeong, Jung-Hyeon;Lee, Jong-Gyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.248-258
    • /
    • 1997
  • The analytical solutions of the Fraunhofer Diffraction(FD) theory and the principle for measurement of the dispersion relation of plasma wave is presented. Especially, the method for measurement of low-frequency wave is discussed. The wavenumbers of the density fluctuations are obtained from the curve fitting between the expremental FD profile and theoretical one for each frequency component. In measurement of the wavenumber of the low -frequency region, the information of the wavenumber is easily obtained from the ratio of the intensity at = 0 to the intensity at =0.5. The millimeter wave FD apparatus was designed to measure low-frequency density fluctuations. The determined wavenumbers are in the range of =0.1~ 1.0cm. Thus, the millimeter wave FD method was shown to be useful for the measurement of low-frequency density fluctuations, which are impossible to be measured by using a convention. Thomson scattering. The obtained dispersion relations will be useful information for plasma waves.

  • PDF

Finite Element Simulation and Experimental Study on the Electrochemical Etching Process for Fabrication of Micro Metal Mold (미세금형 가공을 위한 전기화학식각 공정의 유한요소 해석 및 실험결과 비교)

  • Ryu, Heon-Yul;Im, Hyeon-Seung;Cho, Si-Hyeong;Hwang, Byeong-Jun;Lee, Sung-Ho;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.22 no.9
    • /
    • pp.482-488
    • /
    • 2012
  • To fabricate a precise micro metal mold, the electrochemical etching process has been researched. We investigated the electrochemical etching process numerically and experimentally to determine the etching tendency of the process, focusing on the current density, which is a major parameter of the process. The finite element method, a kind of numerical analysis, was used to determine the current density distribution on the workpiece. Stainless steel(SS304) substrate with various sized square and circular array patterns as an anode and copper(Cu) plate as a cathode were used for the electrochemical experiments. A mixture of $H_2SO_4$, $H_3PO_4$, and DIW was used as an electrolyte. In this paper, comparison of the results from the experiment and the numerical simulation is presented, including the current density distribution and line profile from the simulation, and the etching profile and surface morphology from the experiment. Etching profile and surface morphology were characterized using a 3D-profiler and FE-SEM measurement. From a comparison of the data, it was confirmed that the current density distribution and the line profile of the simulation were similar to the surface morphology and the etching profile of the experiment, respectively. The current density is more concentrated at the vertex of the square pattern and circumference of the circular pattern. And, the depth of the etched area is proportional to the current density.

Development of Extraction Method of Slab Curling Shape of jointed Concrete Pavement Using Profile Data (줄눈 콘크리트포장의 프로파일 데이터를 이용한 슬래브의 컬링형상 추출기법 개발)

  • Chon, Beom-Jun;Lee, Seung-Woo;Mun, Sung-Ho
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.9-18
    • /
    • 2008
  • Curling is caused by the difference in the temperature and humidity by the depth of the slab in Jointed Plain Concrete Pavement. Slab curvature shape and size change due to curling exert a profound influence on the internal stress and roughness of the pavement, affecting structural and functional performance of the pavement. Direct measurement of the slab curvature entails many problems. Many measuring instruments have to be installed at the early-stage of the pavement construction, and the behavior of the slab curvature needs to be measured accurately from the early-stage. Moreover, the cost and technical difficulty are very formidable to measure the slab curvature. This study develops a measurement method for slab curvature in jointed concrete pavement at any given time by applying Power Spectrum Density Analysis and Inverse Fast Fourier Transformation to the profile data, that can be easily obtained at the construction field site. The effectiveness of this developed method is verified by measuring the profile data of the test road of jointed concrete pavement at an inland central expressway by the hour and by examining the result of extracting the slab curvature shape from this profile data. Additionally, the profile data of CRCP(Continuously Reinforced Concrete Pavement) sections on the same expressway were obtained and analyzed at the same time. The validity of the method developed for the slab curvature shape extraction is verified by comparing the result from the analysis of the profile data of CRCP sections with that from the analysis of the prof1Ie data of jointed concrete pavement sections.

  • PDF

ROCKET MEASUREMENT OF MIDDLE ATMOSPHERIC OZONE CONCENTRATION PROFILE BY KSR-II

  • KimJhoon
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.391-400
    • /
    • 1998
  • KSR-II, a two-stage sounding rocket of KARI was launched successfully at the west coast of the Korean Peninsula at 1000LST, June 11, 1998. For the ozone measurement mission, 8-channel UV and visible radiometers were onboard the rocket. The rocket measured the first in situ stratospheric and mesospheric ozone density profile over Korea during its ascending phase using the radiometer. Comparisons with Dobson spectrophotometer, ozonesonde, and HALOE onboard the UARS are shown together. Our results are in reasonable agreements with others.

  • PDF

Study on the Reconstruction of KSTAR Plasma Density Profiles Using Microwave Reflectometry (마이크로파 레플렉토메터리를 이용한 KSIAR 플라즈마 밀도분포 재구성에 관한 연구)

  • Roh Young-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.365-370
    • /
    • 2005
  • Microwave diagnostics have been widely utilized to measure the important parameters of high temperature and high density plasmas. Reflectometry is known as a promising microwave diagnostic which has a number of merits to measure electron density profiles. In the KSTAR device, X-mode FM reflectometry is planned to measure the plasma density profiles. FM reflectometry is required to extract phase information on raw mixer IF signals, thereby obtaining time-of-flight of reflectometry signals. It is known that the data analysis method is crucial to determine the performance of FM reflectometry In fact, there are several analysis programs which have been utilized in various FM systems. Since each program was developed for a specific device, however, it is difficult to directly apply it to a different reactor like the KSTAR device. It is necessary, therefore, to develop a data analysis program for the KSTAR FM reflectometry. In this paper, complex digital demodulation (CDM) and wavelet transformation are examined in terms of the performance of density profile reconstruction. For the comparison of both methods, FM reflectometry signals are generated on the basis of assumed profiles and the interaction of the X-mode wave and the plasma. In order to see how well both methods work under various conditions, three types of profiles are assumed and noise effects are included. As a result, both methods work well under the condition of gentle density gradient and small noise level. As density gradient becomes steeper and noise level gets higher. the reconstruction performance of wavelet is better than that of CDM.