• 제목/요약/키워드: Density Detector Measurement

검색결과 44건 처리시간 0.021초

Opto-Mechanical Detailed Design of the G-CLEF Flexure Control Camera

  • Jae Sok Oh;Chan Park;Kang-Min Kim;Heeyoung Oh;UeeJeong Jeong;Moo-Young Chun;Young Sam Yu;Sungho Lee;Jeong-Gyun Jang;Bi-Ho Jang;Sung-Joon Park;Jihun Kim;Yunjong Kim;Andrew Szentgyorgyi;Stuart McMuldroch;William Podgorski;Ian Evans;Mark Mueller;Alan Uomoto;Jeffrey Crane;Tyson Hare
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.169-185
    • /
    • 2023
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the first instrument for the Giant Magellan Telescope (GMT). G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. G-CLEF Flexure Control Camera (FCC) is included as a part in G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within GCFEA. FCC consists of an optical bench on which five optical components are installed. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimager and a detector (Andor iKon-L 936 CCD camera). The collimator consists of a triplet lens and receives the beam reflected by a fiber mirror. The neutral density filters make it possible a broad range star brightness as a target or a guide. The focus analyzer is used to measure a focus offset. The reimager focuses the beam from the collimator onto the CCD detector focal plane. The detector module includes a linear translator and a field de-rotator. We performed thermoelastic stress analysis for lenses and their mounts to confirm the physical safety of the lens materials. We also conducted the global structure analysis for various gravitational orientations to verify the image stability requirement during the operation of the telescope and the instrument. In this article, we present the opto-mechanical detailed design of G-CLEF FCC and describe the consequence of the numerical finite element analyses for the design.

CDMA 기지국에서 Pilot $E_c/I_o$ 보상기법을 이용한 수신감도 측정에 관한 연구 (A Study on Receiver Sensitivity Measurement using Pilot $E_c/I_o$ Compensation Method at CDMA Communication Network)

  • 정기혁;나극환
    • 대한전자공학회논문지TC
    • /
    • 제44권8호
    • /
    • pp.9-16
    • /
    • 2007
  • 운용중인 기지국에서 각종 RF 파라미터의 측정은 매우 제한적으로 이루어지고 있으며, 일부 수행되고 있는 측정에서 조차 비교적 측정이 용이한 순방향 항목에 집중되고 있다. 본 논문에서는 기지국에 설치된 순방향 모니터링 포트를 이용하여 기지국의 역방향의 무선 품질을 측정이 기능한 측정장치를 설계하여 실제 운용 중인 기지국에서 검증시험을 실시함으로써 연구의 완성도 향상을 꾀하였다. 수신감도의 측정은 내장된 CDMA 모뎀을 이용하여 기지국과 음성호가 연결된 상태에서 폐루프 전력제어에 의한 모뎀의 출력을 감시함으로써 이루어질 수 있도록 하였다. 보다 정확한 계측을 위하여 모뎀의 TxAdj 파라미터와 함께 디텍터에 의한 실측 데이터를 이용하였다. 정확한 수신감도의 측정을 위해서는 트래픽이 없는 상황에서 측정이 이루어져야 하지만, 운용중인 시스템에서는 상황재현이 어려우므로 통화량 증가에 의한 수신감도의 열화정도를 보상함으로써 시간에 구애받지 않고 정확한 측정값을 얻을 수 있도록 $E_c/I_o$에 의한 보상기법을 적용하였다.

Monte Carlo 모사기법을 이용한 해체 콘크리트의 방사능 분석법 연구 (A Study on the Radioactivity Analysis of Decommissioning Concrete Using Monte Carlo Simulation)

  • 서범경;김계홍;정운수;이근우;오원진;박진호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.43-51
    • /
    • 2004
  • 현재 해체가 진행 중인 연구로 1. 2호기의 원자로 차폐 콘크리트를 해체하기 위해서는 운전기간동안 중성자 조사에 의한 방사화 정도 및 범위를 정확하게 결정하여야 한다. 차폐 콘크리트의 방사화 정도 및 범위를 결정하기 위해서 코어 시료를 채취하여 분석하여야 하는데, 시료 전처리의 어려움과 표준선원의 준비 및 자체흡수효과에 의하여 정확한 측정효율을 결정하는데 어려움이 있다. 본 연구에서는 방사능 분석에 이용되는 HPGe 검출기의 전에너지 검출 효율을 표준선원을 이용한 측정값과 Monte Carlo 방법을 이용하여 계산 값을 비교하였다. 또한, Monte Carlo 모사 기법을 이용하여 콘크리트의 밀도 및 성훈 변화에 따른 자체흡수 효과를 계산하였으며, 향후 실제 콘크리트 코어 시료를 채취 시 방사능 분석에 이용할 계획이다.

  • PDF

공기중의 라돈 농도 측정을 위한 CR-39의 교정 (Calibration of CR-39 for Measurement of Radon in Air)

  • 박영웅;장시영;하정우;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.18-22
    • /
    • 1989
  • CR-39 고체비적검출기를 교정하기 위하여 밀봉 순환 방식의 고체비적검출기 교정 장치와 밀리포어필터가 부착된 라돈컵을 제작한 후 기지의 라돈농도에 대한 비적 수를 측정하였다. 그 결과 CR-39 고체비적검출기의 단위 면적당 생성된 비적 수에 대한 시간 적분 라돈 농도는 $0.24{\pm}0.09(pCi/l){\cdot}day/(Tr/cm^2)$ 였다.

  • PDF

Space Physics Sensor on KOMPSAT-1

  • Min, Kyoung-Wook;Choi, Young-Wan;Shin, Young-Hoon;Lee, Jae-Jin;Lee, Dae-Hee;Kim, Jhoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.355-360
    • /
    • 1998
  • A small package of plasma instruments, Space Physics Sensor, will monitor the space environment and its effects on microelectronics in the low altitude region as it operates on board the KOMPSAT-1 from 1999 over the maximum of the solar cycle 23. The Space Physics Sensor (SPS) consists of two parts: the Ionospheric Measurement Sensor (IMS) and the High Energy Particle Detector (HEPD). IMS will make in situ Measurements of the thermal electron density and temperature, and is expected to provide a global map of the thermal electron characteristics and the variability according to the solar and geomagnetic activity in the high altitude ionosphere of the KOMPSAT-t orbit. HEPD will measure the fluxes of high energy protons and electrons, monitor the single event upsets caused by these energetic charged particles, and give the information of the total radiation dose received by the spacecraft. The continuous operation of these sensors, along with the ground measurements such as incoherent scatter radars, digital ionosondes and other spacecraft measurements, will enhance our understanding of this important region of practical use for the low earth orbit satellites.

  • PDF

초소형 광 픽업용 하이브리드 렌즈의 능동 정렬 및 성능평가 (Active Alignment and Performance Evaluation of Micro Hybrid Lens for Small Form Factor Optical Pickup)

  • 강성묵;이진의;조은형;손진승;박노철;박영필
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.154-159
    • /
    • 2005
  • The next generation of optical storage systems requires higher numerical aperture (NA) objective lenses and shorter wavelength laser in order to improve the unit areal density. A blu-ray technology satisfies a miniaturization and a high capacity which are the requirements of the portable device. In this paper, we analyze the optical performance of hybrid micro lens and do active alignment. The hybrid micro lens is manufactured by using a wafer based fabrication technology. Optical components of hybrid micro lens are evaluated. The measurement of the optical power, the spot size and the wavefront error awe performed to evaluate the hybrid micro lens with NA 0.85. Using the measured data, we estimate if the performance of hybrid micro lens corresponds to the designed performance. After the performance of hybrid micro lens is evaluated, the integrated optical pickup and the hybrid micro lens are assembled by active alignment using UV curing and the optical performance of SFFOP is satisfied with BD specifications.

  • PDF

초소형 광 픽업용 하이브리드 렌즈의 능동 정렬 및 성능평가 (Active Alignment and Performance Evaluation of Micro Hybrid Lens for Small Form Factor Optical Pickup)

  • 강성묵;이진의;조은형;손진승;박노철;박영필
    • 정보저장시스템학회논문집
    • /
    • 제2권1호
    • /
    • pp.79-84
    • /
    • 2006
  • The next generation of optical storage systems requires higher numerical aperture(NA) objective lenses and shorter wavelength laser in order to improve the unit areal density. A blu-ray technology satisfies a miniaturization and a high capacity which are the requirements of the portable device. In this paper, we analyze the optical performance of hybrid micro lens and do active alignment. The hybrid micro lens is manufactured by using a wafer based fabrication technology. Optical components of hybrid micro lens are evaluated. The measurement of the optical power, the spot size and the wavefront error are performed to evaluate the hybrid micro lens with NA 0.85. Using the measured data, we estimate if the performance of hybrid micro lens corresponds to the designed performance. After the performance of hybrid micro lens is evaluated. the integrated optical pickup and the hybrid micro lens are assembled by active alignment using UV curing and the optical performance of SFFOP is satisfied with BD specifications.

  • PDF

THE EFFECT OF THE HIGH DENSITY PLASMA ON THE DIAMOND-LIKE CARBON FILMS

  • Kim, H.;D.H. Jung;Park, B.;K. C. Yoo;Lee, J. J.;J. H. Joo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 추계학술발표회초록집
    • /
    • pp.54-54
    • /
    • 2003
  • DLC films were deposited on Si(100) substrates by inductively coupled plasma (ICP) assisted chemical vapor deposition (CVD). A mixture of acetylene (C$_2$H$_2$) and argon (Ar) gases was used as the precursor and plasma source, respectively. The structure of the films was characterized by the Raman spectroscopy. Results from the Raman spectroscopy analysis indicated that the property change of the DLC films is due to the sp$^3$ and sp$^2$ ratio in the films under various conditions such as ICP power, working pressure and RF substrate bias. The hydrogen content in the DLC films was determined by an electron recoil detector (ERB). The roughness of the films was measured by atomic force microscope (Am). A microhardness tester was used for the hardness and elastic modulus measurement. The DLC film showed a maximum hardness of 37㎬. In this work, the relationship between deposition parameters and mechanical properties were discussed.

  • PDF

방사성폐기물드럼 핵종분석에서 감마선 감쇠보정 방법들의 비교 평가 (Comparison of the Correction Methods for Gamma Ray Attenuation in the Radioactive Waste Drum Assay)

  • 지영용;유영걸;곽경길;강덕원;김기홍
    • 방사성폐기물학회지
    • /
    • 제4권3호
    • /
    • pp.275-284
    • /
    • 2006
  • 실제 드럼 내에 존재하는 핵종으로부터 방출되는 감마선을 외부에서 측정하여 그로부터 드럼 내 핵종의 양을 정확하게 분석하기 위해서는 먼저 적절한 교정표준의 선택과 드럼 내 매질의 밀도와 핵종의 분포에 대한 감마선 감쇠보정이 반드시 필요하다. 본 연구에서는 드림 내 핵종의 분석을 위하여 밀도가 다른 두 개의 모델드럼을 이용하였으며 전송선원으로써는 $^{152}Eu$(10 mCi), 표준선원으로는 혼합선원($^{133}Ba,\;^{137}Cs,\;^{60}Co$)을 이용하였다. 그리고 드럼과 검출기 사이의 거리를 달리하면서 모델드럼 내의 표준선원으로부터 나오는 감마선을 계측하여, 감쇠보정이 되지 않은 이 측정값에 3 종류의 감마선 감쇠보정을 각각 수행하였다. 그 결과 밀도가 낮은 드럼에서의 오차는 10 % 이하이었고, 밀도가 높은 드럼에서의 오차는 25 % 이하이었다. 또한 드럼과 검출기사이의 거리가 근거리(70 cm, 드림구획 : 10 segments)일 때, 오차는 원거리(90 cm, 드럼구획 : 8 segments)에서의 오차보다는 낮았는데 이는 상대적으로 1 segment에 대한 부피차이에 기인한 밀도 측정오차가 낮고 감마선의 산란이 낮았기 때문이다.

  • PDF

건강검진에서 지방간 진단의 상복부초음파검사와 간 Hounsfield Units 측정값과의 정확성 분석 (Fatty Liver Diagnostics from Medical Examination to Analyze the Accuracy Between the Abdominal Ultrasonography and Liver Hounsfield Units)

  • 오왕균;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.229-235
    • /
    • 2017
  • 상복부초음파검사에서 간실질의 에코 음영증가와 불명확한 혈관경계 등으로 지방간을 진단하는데, 여러 연구들에 의하면 지방간 진단에 84~95%의 특이도와 60~90%의 민감도를 가지나 결과가 검사자에 의존적이어서 차이가 있을 수 있고 지방의 침윤 상태의 정량적인 측정이 불가능하다. 건강검진의 상복부초음파검사와 흉부 전산화단층촬영(computed tomography; CT) 검사를 같은 날에 시행한 수검자중 초음파검사에서 지방간을 진단 받은 환자의 흉부 전산화단층촬영 영상에서 간(Liver) Hounsfield Units(HU)를 측정하여 지방간 진단의 정확성을 연관분석 하고자 하였다. 연구대상 수검자 720명 중 가정의학과 전문의에게 검사를 받고 지방간 판정을 받은 자는 448명으로 62.2%였다. 지방간 판정자의 CT영상에서 간 HU를 측정한 결과 40 HU 이하의 측정값은 720명 중 175명으로 24.3%이며, 초음파에서 진단 받은 448명에 175명 중 173명이 포함되어 98.9%가 일치하였다. 이는 지방간을 초음파로 진단 시 검사자의 주관적 경험과 능력이 병변을 진단하는데 크게 영향을 미친 것으로 생각되며 검진 CT검사에서 간 HU를 측정하여 40 HU 이하는 영상저장을 통하여 지방간 진단 시 참고자료로 활용될 수 있을 것으로 사료된다.