• 제목/요약/키워드: Demand Capacity Ratio (DCR)

검색결과 4건 처리시간 0.021초

Progressive collapse analysis of buildings with concentric and eccentric braced frames

  • Larijan, Reza Jalali;Nasserabadi, Heydar Dashti;Aghayan, Iman
    • Structural Engineering and Mechanics
    • /
    • 제61권6호
    • /
    • pp.755-763
    • /
    • 2017
  • In this study, the susceptibility of different symmetric steel buildings with dual frame system to Progressive Collapse (PC) was assessed. Some ten-story dual frame systems with different type of braced frames (concentrically and eccentrically braced frames) were considered. In addition, numbers and locations of braced bays were investigated (two and three braced bays in exterior frames) to quantitatively find out its effect on PC resistance. An Alternate Path Method (APM) with a linear static analysis was carried out based on General Services Administration (GSA 2003) guidelines. Maximum Demand Capacity Ratio (DCR) for the elements (beams and columns) with highest DCRs ($DCR_{moment}$ and $DCR_{shear}$) is given in tables. The results showed that the three braced bays with concentric braced frames especially X-braced and inverted V-braced frame systems had a lower susceptibility and greater resistance to PC. Also, the results represented that the beams were more critical than columns against PC after the removal of column.

Progressive collapse analysis of two existing steel buildings using a linear static procedure

  • JalaliLarijani, Reza;Celikag, Murude;Aghayan, Iman;Kazemi, Mahdi
    • Structural Engineering and Mechanics
    • /
    • 제48권2호
    • /
    • pp.207-220
    • /
    • 2013
  • In this study, the vulnerability of two existing asymmetric steel building frames to Progressive Collapse (PC) is assessed. The buildings have different frame systems, steel sections and number of stories (nine and six). An alternate path method (APM) with a linear static analysis (LS) is carried out according to General Services Administration (GSA) 2003 guidelines. The Demand Capacity Ratio (DCR) of each primary element (beams and columns) is given with its specific details for all frames. The results show that the nine-story building with a dual frame system (moment frame with bracing system) has a lower susceptibility and greater resistance to PC than the six-story building with a simple building frame system (gravity system with bracing system). Implementing built-up box-shaped sections for columns is a better choice than using built-up I-shaped sections because there is no weak axis for the box section.

트러스 형태에 따른 스태거드트러스 골조시스템의 내진성능 평가 (Seismic Performance Evaluation of Staggered Truss System by the Shape of Truss)

  • 홍윤수;유은종;나창순
    • 한국전산구조공학회논문집
    • /
    • 제30권5호
    • /
    • pp.397-404
    • /
    • 2017
  • 본 연구의 목적은 트러스의 형태를 바꿔가며 엇갈린 트러스(STF) 시스템의 내진성능을 평가하는 것이다. 예제 구조물은 10층의 철골조 사무실 건물이며, 시스템별로 각각 프랫트러스, 하우트러스, 와렌트러스, 케이트러스와 비렌딜트러스를 적용하였다. 중력하중, 풍하중, 지진하중을 고려한 구조해석을 실시하여 부재에 높은 DCR을 만족하는 단면을 산정한 후 고유주기, 밑면전단력과 층간변위를 산출하였다. 그 후, 역량스펙트럼법을 통해 1.2배의 설계지진(DE)과 최대고려지진(MCE)에 대한 성능점을 산정하고, STF 시스템의 항복여부 및 소성힌지의 분포를 파악하여 구조기준에서 제시한 목표성능수준을 만족하는지 살펴보았다. 평가 결과, 모든 시스템이 해당 목표성능수준을 만족하였으며, 시스템의 경제성 및 효율성을 따져보았을 때, PR10이나 VR10이 가장 적합한 것으로 나타났다.

정적 및 동적 해석을 통한 철근콘크리트 무량판 구조의 연쇄 붕괴 저항 성능 평가 (Evaluation for Progressive Collapse Resistance of a RC Flat Plate System Using the Static and Dynamic Analysis)

  • 이선웅;신성우
    • 콘크리트학회논문집
    • /
    • 제23권2호
    • /
    • pp.245-252
    • /
    • 2011
  • 현재 한국에서는 연쇄 붕괴에 대한 설계지침이 적용되고 있지 않으며, 특히 무량판 구조의 연쇄 붕괴 저항 성능에 대한 연구는 초기단계라고 할 수 있다. 따라서 이 연구에서는 철근콘크리트 무량판 구조의 연쇄 붕괴 저항 성능을 평가하기위하여 3가지 해석법을 수행하였다. 선형 정적 해석을 통하여 GSA의 대체경로법에 의한 DCR 값의 차이를 비교하였고, 선형 동적 해석을 통하여 기둥 제거 이후의 수직 변위를 비교하였으며, 비선형 정적 해석을 통하여 최대 하중 계수를 판단하였다. 유효 보폭 모델과 판 유한 요소 해석 모델의 차이점을 분석하기 위하여 여러 변수들에 따라 유한 요소 해석이 수행되었다. 무량판 구조에서 실무에서 많이 사용되고 있는 유효 보폭으로 모델링하는 방법은 슬래브의 강성 기여도를 반영하고 있지 못해 연쇄 붕괴 성능 평가는 상세 유한 요소 해석이 적절할 것으로 판단된다. 여러 변수들을 종합 모서리 기둥(CC)을 제거할 경우가 가장 불리한 조건이고, 내부 기둥(IC)이 제거될 경우가 가장 유리한 조건으로 나타났다. 이 연구에서 제시된 무량판 구조의 연쇄 붕괴 저항 성능 결과로부터 향후 무량판 구조의 성능을 합리적으로 평가하는데 유용하게 활용될 수 있을 것으로 사료된다.