• Title/Summary/Keyword: Delivery loading

Search Result 207, Processing Time 0.083 seconds

A Study on the Delivery of Goods and Conditions of Contract of Carriage under Incoterms 2010 (Incoterms 2010상 물품인도 및 운송계약조건에 관한 연구)

  • PARK, Sung-Cheul
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.66
    • /
    • pp.75-94
    • /
    • 2015
  • The aim of this study is to examine the obligations of delivery of the goods focusing on the methods of delivery under the Incoterms 2010, comparing with CISG. The Incoterms 2010 provides various methods of delivery of the goods under the each rule(11 rules). And it is a little confusing for the parties of the contract of sales. This study reviewed specific methods of delivery of the goods with the view of practitioner. The purpose of Incoterms is to avoid misunderstanding of the contract of sales and to promote the international transactions. The uncertainties of the Incoterms 2010 shall cause disputes between the parties. Especially, when vehicles are used to pick up and deliver the goods, which party is responsible for the loading and unloading the goods. Under the D-term, which party is responsible for unloading the goods from the vehicle reached at the named place of destination is a little confusing. This study suggest some ideas on the specific methods of delivery to mitigate uncertainties and accept current practices at the field. Firstly, under the EXW rule, the seller must deliver the goods on the arriving means of transport at the seller's premises. Secondly, under the FCA rule, the seller must deliver the goods unloaded at the other place except seller's premises. Thirdly, under the CPT, CIP rules, the seller must deliver the goods unloaded irrespective of the mode of transport at the place of destination. Fourthly, the FOB, CFR, CIF rules must adapt the container transport practice.

  • PDF

A Study on the Pre-printed Clause of the Bill of Lading (선하증권 인쇄약관에 관한 연구)

  • Park, Sae-Woon
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.49
    • /
    • pp.359-378
    • /
    • 2011
  • UCP600 Article 20 (a) (v) states that contents of terms and conditions of carriage will not be examined and Article 34 states that a bank assumes no liability or responsibility for the general or particular conditions stipulated in a document. From this perspective, banks may seem to have no obligation to examine the pre-printed clause of B/L. However, ICC decided that no opinion could be given in relation to the issues surrounding B/Ls that contain delivery clauses. Accordingly, it is agreed by previous cases and some scholars that banks may refuse the B/Ls that contain delivery clauses which are not present in other B/Ls of the same goods and transport routes. Also, ICC published ICC Decision in July 2010 regarding on board notation. In this decision, if a B/L indicates a place of receipt that is different from the port of loading and there is an indication of a means of pre-carriage, then a dated on board notation will be required indicating the name of the vessel and the port of loading. Therefore, banks may,, in some cases, need to scrutinize the pre-printed clauses especially appearing in the front page of B/Ls.

  • PDF

Temperature-Induced Release of All-trans-Retinoic Acid Loaded in Solid Lipid Nanoparticles for Topical Delivery

  • Lee, Chang-Moon;Jeong, Hwan-Jeong;Park, Ji-Won;Kim, Jin;Lee, Ki-Young
    • Macromolecular Research
    • /
    • v.16 no.8
    • /
    • pp.682-685
    • /
    • 2008
  • The aim of this work was to develop and evaluate solid lipid nanoparticles (SLN) containing all-trans-retinoic acid (ATRA) for topical delivery. SLN composed of coconut oil and curdlan improved the suspension instability of ATRA in aqueous solution. The photodegradation of ATRA by light was reduced by incorporation in SLN. The loading efficiency of ATRA in SLN was higher than 95% (w/w). The amounts of ATRA released from SLN at $4^{\circ}C$ and at $37^{\circ}C$ were less than 15% and more than 60% (w/w) for 96 h, respectively. The ATRA-loaded SLN can be used as a potential carrier for topical delivery.

Enhanced Controlled Transdermal Delivery of Hydrochlorothiazide from an Ethylene-vinyl Acetate Matrix

  • Kim, Dal-Keun;Park, Jung-Chan;Chang, Ik-Hyun;Kang, Chung;Ryu, Sang-Rok;Shin, Sang-Chul
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.3
    • /
    • pp.167-173
    • /
    • 2010
  • Repeated oral administration of hydrochlorothiazide, a loop diuretic, due to transient high blood levels, may cause adverse effects such as gastric disturbance, nausea, high blood sugar, and hyper lipidemia. Transdermal administration could avoid some of these systemic side effects and gastric disorders. We have developed a matrix using ethylene-vinyl acetate (EVA), a heat-processible and flexible material, for transdermal delivery of hydrochlorothiazide. Drug solubility was highest at 40% PEG-400 volume fraction. Drug release increased as concentration increased with a linear relationship between the release rate and the square root of loading dose. Increasing temperature increased drug release from the EVA matrix. The activation energy, measured from the slope of log P versus 1000/T, was 11.9 kcal/mol for a 2.5% loading dose from EVA matrix. Diethyl phthalate had the highest plasticizing effects on the release of hydrochlorothiazide. To increase the skin permeation of hydrochlorothiazide from the EVA matrix, enhancers such as the saturated fatty acids, the unsaturated fatty acids, and the non-ionic surfactants were added to the EVA matrix, and skin permeation was evaluated using a modified Keshary-Chien diffusion cell fitted with intact excised rat skin. Polyoxyethylene 23-lauryl ether showed the highest enhancing effects. In conclusion, transdermal delivery of hydrochlorothiazide could be improved from an EVA matrix containing plasticizer and permeation enhancer.

Least Squares Method-Based System Identification for a 2-Axes Gimbal Structure Loading Device (2축 짐벌 구조 적재 장치를 위한 최소제곱법 기반 시스템 식별)

  • Sim, Yeri;Jin, Sangrok
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.3
    • /
    • pp.288-295
    • /
    • 2022
  • This study shows a system identification method of a balancing loading device for a stair climbing delivery robot. The balancing loading device is designed as a 2-axes gimbal structure and is interpreted as two independent pendulum structures for simplifying. The loading device's properties such as mass, moment of inertia, and position of the center of gravity are changeable for luggage. The system identification process of the loading device is required, and the controller should be optimized for the system in real-time. In this study, the system identification method is based on least squares method to estimate the unknown parameters of the loading device's dynamic equation. It estimates the unknown parameters by calculating them that minimize the error function between the real system's motion and the estimated system's motion. This study improves the accuracy of parameter estimation using a null space solution. The null space solution can produce the correct parameters by adjusting the parameter's relative sizes. The proposed system identification method is verified by the simulation to determine how close the estimated unknown parameters are to the real parameters.

Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study

  • Mu, Teh-Jing;Lee, Dong-Won;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.5
    • /
    • pp.209-214
    • /
    • 2013
  • Purpose: To assess bony trabecular changes potentially caused by loading stress around dental implants using fractal dimension analysis. Methods: Fractal dimensions were measured in 48 subjects by comparing radiographs taken immediately after prosthesis delivery with those taken 1 year after functional loading. Regions of interest were isolated, and fractal analysis was performed using the box-counting method with Image J 1.42 software. Wilcoxon signed-rank test was used to analyze the difference in fractal dimension before and after implant loading. Results: The mean fractal dimension before loading ($1.4213{\pm}0.0525$) increased significantly to $1.4329{\pm}0.0479$ at 12 months after loading (P<0.05). Conclusions: Fractal dimension analysis might be helpful in detecting changes in peri-implant alveolar trabecular bone patterns in clinical situations.

Active components delivery rate from acrylic resin maxillary surgical obturator: Part I

  • Al-Kaabi, Arshad;Hamid, Mohammed A.
    • Advances in materials Research
    • /
    • v.9 no.2
    • /
    • pp.109-114
    • /
    • 2020
  • The purpose of this study was to observe the trend of compounds release from acrylic resin oral prosthesis when used for drug delivery as well as a restoration. In this study, 10 specimens of heat-cured polymethylmethacrylate material were prepared and loaded with methylene blue biological stain. The specimens were then submerged in vials with 5 ml distilled water for 24 hours. The extraction procedure continued for 4 days, each day the specimens were immersed in another 5 ml distilled water vial. All extracted solutions were analyzed by visible light spectroscopy for absorbance comparison. The statistical results showed that the absorbance values were significantly different in the first day of extraction than the following days. However, there was no statistical difference among the 2nd, 3rd and 4th days of extraction. Biological stain loading to acrylic resin at the mixing stage, and then after extraction in distilled water, showed a burst release during the first day followed by a constant release during the following few days.

Ergonomic Approach through Process Analysis of Delivery Work (택배 배송 작업의 공정분석을 통한 인간공학적 접근 방안)

  • Sejung Lee;Sangeun Jin;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.55-61
    • /
    • 2024
  • In response to the COVID-19 pandemic, the logistics industry in Korea has rapidly been expanding, with offline demand concentrating on online platforms owing to the development of digital infrastructure. This has increased the workload of courier drivers considerably, along with labor intensity. A delivery driver died recently from overwork due to the continuous increase in delivery volume, which raises social concerns. Delivery drivers work long hours, (over 12 hours) and are greatly affected by weather conditions, such as snow, rain, heat waves, and cold waves. In addition, they lack a fixed workplace; perform atypical work handling workpieces of various sizes, weights, and shapes; and spend a large amount of time driving as part of their work. This work involves a high level of tension and requires attention and concentration. Despite the frequency of industrial accidents in the courier industry, studies on safety and health to quantitatively analyze and systematize the work of courier workers are very scarce. Therefore, to define the work process necessary for investigating the harmful factors in delivery service and the work analysis, this study conducted interviews and on-site surveys to analyze the unit work of the delivery service by targeting delivery workers. In other words, a framework of unit work for work analysis was presented to enable research and analysis by considering the aforementioned characteristics of the courier industry. The process was broadly divided into work, transport, storage, delay, and inspection. Work was divided into loading, sorting, unloading, and door subcategories, and transportation was divided into vehicle, cart, and walking subcategories as well as 10 small processes. Moreover, 22 unit works were again drawn by conducting field surveys and interviews. The risk of unit work derived from this study was ergonomically evaluated, and the ergonomic analysis revealed that uploading and transportation were the most dangerous. The results of this study could be used as basic data for preventing industrial accidents among courier workers, whose work has increased with the logistics volume and the development of the logistics industry.

Formulation and In vitro Evaluation of Transdermal Drug Delivery System for Galantamine

  • Hossain, Md. Kamal;Subedi, Robhash Kusam;Chun, Myung-Kwan;Kim, Eun-Jung;Moon, Hwan-Shik;Choi, Hoo-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • The effects of different formulation variables including pressure sensitive adhesive (PSA), permeation enhancer, thickness of the matrix and loading amount of drug on the transdermal absorption of galantamine were investigated across the hairless mouse skin. The permeation profile of galantamine was different depending on the types of PSA, loading amount of drug, thickness of the matrix and type of enhancer used. Highest flux of galantamine was obtained from acrylic PSA but crystals were formed in the patch within 72 h. Among the PSAs screened, crystal formation was not observed only in the patches formulated in Styrene Butadiene Styrene (SBS) matrix. Permeation rate increased linearly as the concentration of galantamine in SBS matrix increased from 2.5 to 15% w/w. Among the enhancers screened, Brij$^{(R)}$ 30 provided highest flux of galantamine. Matrix thickness of 80 ${\mu}m$ was optimum for maintaining adhesiveness as well as consistently delivering galantamine for longer period of time.

Curcumin-Loaded PLGA Nanoparticles Coating onto Metal Stent by Electrophoretic Deposition Techniques

  • Nam, So-Hee;Nam, Hye-Yeong;Joo, Jae-Ryang;Baek, In-Su;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.397-402
    • /
    • 2007
  • Restenosis after percutaneous coronary intervention (PCI) continues to be a serious problem in clinical cardiology. To solve this problem, drug eluting stents (DES) with antiproliferative agents have been developed. Variable local drug delivery systems in the context of stenting require the development of stent manufacture, drug pharmacology and coating technology. We have worked on a system that integrates electrophoretic deposition (EPD) technology with the polymeric nanoparticles in DES for local drug delivery and a controlled release system. The surface morphology and drug loading amount of DES by EPD have been investigated under different operational conditions, such as operation time, voltage and the composition of media. We prepared poly-D,L-lactide-co-glycolic acid (PLGA) nanoparticles embedded with curcumin, which was done by a modified spontaneous emulsification method and used polyacrylic acid (PAA) as a surfactant because its carboxylic group contribute negative charge to the surface of CPNPs (?53.5 ± 5.8 mV). In the process of ‘trial and error' endeavors, we found that it is easy to control the drug loading amount deposited onto the stent while keeping uniform surface morphology. Accordingly, stent coating by EPD has a wide application to the modification of DES using various kinds of nanoparticles and drugs.