• Title/Summary/Keyword: Degradation rate

Search Result 2,405, Processing Time 0.031 seconds

Thermal Degradation Behavior and Reliability Analysis of Plastic Materials for Household Electric Appliances (가전제품용 플라스틱 재료의 열분해 거동 및 신뢰성 평가)

  • Im, Chang-Gyu;Kim, Jun-Young;Kim, Seong-Hun
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.508-517
    • /
    • 2005
  • The thermal degradation behavior and reliability analysis were investigated using dynamic thermogravimetric analysis (TGA) and accelerated degradation test (ADT) to characterize the dynamic parameters related to thermal degradation of plastic meterials for household electric appliances. In addition, the weathering of the plastic were performed by ADT using Xenon uc, and the color difference of the samples after ADT were measured with Color Eye 3010 specoophotometer. he activation energy for thermal degradation of the samples increased with increasing the rate of weight loss. The Kim-Park method was found to be more effective analysis in describing thermal degradation of plastic meterials. Plastic materials were very sensitive to ultra-violet rays in faster degradation.

An experimental study on the characteristic times of viscoelastic fluids by falling ball viscometer (낙구식 점도계를 이용한 점탄성 유체의 특성시간에 관한 실험적 연구)

  • 전찬열;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.241-250
    • /
    • 1990
  • Characteristic relaxation time and characteristic diffusion time of viscoelastic fluids are determined experimentally by measuring the zero-shear-rate viscosity by falling ball viscometer and the infinite-shear-rate viscosity by capillary tube viscometer. Fluids used in experiments are aqueous solutions of polyacrylamide Separan AP-273 and the polymer concentrations range from 300 to 2000 wppm. A newly designed laser beam and timer system is employed to overcome the difficulty in measuring terminal velocities of the low concentration solutions. Ball removal device is prepared to remove the dropped ball from the bottom of cylinder without disturbing the testing fluid. In order to measure the zero-shear-rate viscosity, densities of hollow aluminium balls are adjusted very close to the densities of testing fluids. Characteristic diffusion time, which is ball viscometer. However, terminal velocity of a needle by falling ball viscometer is not affected by the time interval of dropping needles and characteristic diffusion time is not measured with a dropping needle. Powell-Eyring model predicts the highest values of the characteristic relaxation times among models used for heat transfer experimental works for a given polymer solution. As degradation of a polymer solution continues, the zero-shear-rate viscosity decreases more seriously than the infinite-shear-rate viscosity. Characteristic relaxation times of polymer solutions decreases as degradation continues.

The Influence of Coexisting Material on the Photocatalytic Removal of Humic Acid (광촉매를 이용한 Humic Acid 광부해시 공존물질이 광분해에 미치는 영향)

  • Ryu, Seong Pil;Hyeon, Gyeong Ja;O, Yun Geun
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.279-288
    • /
    • 2004
  • This study aimed at improving the $TiO_2$ photocatalytic degradation of HA. A set of tests was first conducted in the dark to study the adsorption of HA at different coexisting material concentration. Adsorption rate increased with adding cation ion but decreased with adding bicarbonate ion. The photodegradation of HA in the presence of UV irradiation was investigated as a function of different experimental condition: initial concentration of HA, $TiO_2$ weight, pH, air flow rate and coexisting material. It was increased either at low pH or by adding cation ion. The increase of cation strength in aqueous solution could provide a favorable condition for adsorption of HA on the $TiO_2$ surface and therefore enhance the photodegradation rate. It was found that bicarbonate ions slowed down the degradation rate by scavening the hydroxyl radicals.

Effect of pH on the Degradation of 2, 4-Dinitrophenol in Sequencing Batch Reactor Process (연속회분식(連續回分式) 처리공정(處理工程)에 의한 2, 4-Dinitrophenol분해시(分解時) pH의 영향(影響))

  • Jo, Kwan-Hyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.96-101
    • /
    • 1998
  • Substrate inhibition of 2,4-dinitrophenol (DNP) degradation was investigated using activated sludge which had been adapted to mineralize DNP. DNP is a metabolic uncoupler, preventing cells from making energy for growth and it has been suggested that pH may be important in mitigating effects of uncouplers. After acclimation of the activated sludge, the effect of pH on toxicity of DNP at high concentration (75 mg/L) was investigated, over a pH range of 5 to 9. DNP inhibition was found to be strongly dependent on mixed liquor pH. The DNP degradation rate was highest in the pH range of 6.95 to 7.84; at pH 5.94 degradation of 75 mg/L DNP was significantly inhibited; at pH < 5.77, DNP degradation was completely inhibited after approximately 30% of the DNP was degraded. By comparison, no significant effect of pH variation in the same range was seen on glucose uptake by the activated sludge culture.

  • PDF

Classification of Degradation Process with XLPE Cable Specimen (XLPE 전력용 케이블 시편의 열화에 따른 분류)

  • Park, Sung-Hee;Park, Jae-Yeol;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.195-197
    • /
    • 2003
  • In this paper, Neural Networks is studied for estimation of XLPE cable specimen according to degradation. And these data making use of a computer-aided discharge analyser, a combination of statistical and discharge parameter was calculated to discrimination processing stage of degradation. NN has not bad recognition rate result of discrimination for degradation stage because discharge characteristics are very similar to between degradation stage. So, there is some improvement for applied NN.

  • PDF

A Study on the Improvement of the Electrical Stability Versus MgO Addictive for ZnO Ceramic Varistors (MgO 첨가에 따른 ZnO 세라믹 바리스터의 신뢰성 향상에 관한 연구)

  • 소순진;김영진;송민종;박복기;박춘배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.427-430
    • /
    • 2001
  • The degradation characteristics versus MgO Additive for the ZnO ceramic devices fabricated by the standard ceramic techniques is investigated in this study. It were made these devices be basic Matsuoka's composition. Especially, MgO were added to analyze the degradation characteristics and sintered in air at 1300$^{\circ}C$. The conditions of DC degradation test were 115${\pm}$2$^{\circ}C$ for 12h. Using XRD and SEM, the phase and microstructure of samples were analyzed respectively. The elemental analysis in the microstructures was used by EDS, E-J analysis was used to determine ${\alpha}$ . Frequency analysis was accomplished to understand the relationship between R$\sub$g/ and $R_{b}$ with the electric stress at the equivalent circuit.

  • PDF

Hot-Carrier-Induced Degradation in Submicron MOS Transistors (Submicron MOS 트랜지스터의 뜨거운 운반자에 의한 노쇠현상)

  • 최병진;강광남
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.7
    • /
    • pp.780-790
    • /
    • 1988
  • We have studied the hot-carrier-induced degradation caused by the high channel electric field due to the decrease of the gate length of MOSFET used in VLSI. Under DC stress, the condition in which maximum substrate current occures gave the worst degradation. Under AC dynamic stress, other conditions, the pulse shape and the falling rate, gave enormous effects on the degradation phenomena, especially at 77K. Threshold voltage, transconductance, channel conductance and gate current were measured and compared under various stress conditions. The threshold voltage was almost completely recovered by hot-injection stress as a reverse-stress. But, the transconductance was rapidly degraded under hot-hole injection and recovered by sequential hot-electron stress. The Si-SiO2 interface state density was analyzed by a charge pumping technique and the charge pumping current showed the same trend as the threshold voltage shift in degradation process.

  • PDF

Electrochemical Degradation of Benzoquinone in a Flow through Cell with Carbon Fibers

  • Yoon, Jang-Hee;Yang, Jee-Eun;Shim, Yoon-Bo;Won, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.403-407
    • /
    • 2007
  • The anodic degradation of benzoquinone(BQ), a model compound for wastewater treatment was carried out using a home-made flow-through electrochemical cell with carbon fibers. To optimize the controlled current electrolysis condition of an aqueous BQ solution, the experimental variables affecting the degradation of BQ, such as the applying current, pH, reaction time, and flow rate of the BQ solution were examined. The degradation products of the oxidation reaction were identified by High Performance Liquid Chromatography and Inductively Coupled Plasma Atomic Emission Spectrometer. Low molecular weight aliphatic acids, and CO2 were the major products in this experiment. The removal efficiency of BQ from the solution increased with the applying current and time. 99.23% of 1.0 × 10-2 M BQ was degraded to aliphatic acids and CO2 when the applying current is 175 mA in a 12 hr electrolysis.

Photocatalytic Degradation of 3-Nitrophenol with ZnO Nanoparticles under UV Irradiation

  • Li, Jiulong;Ko, Weon Bae
    • Elastomers and Composites
    • /
    • v.52 no.2
    • /
    • pp.131-135
    • /
    • 2017
  • Zinc nitrate hexahydrate [$Zn(NO_3){\cdot}6H_2O$] and sodium hydroxide [NaOH] were used as source reagents in the preparation of ZnO nanoparticles in an aqueous solution containing deionized water and ethanol in a ratio of 2:5 (v/v). ZnO nanoparticles were heated in an electric furnace at $700^{\circ}C$ for 2 h under an atmosphere of inert argon gas. The morphological and structural properties of the nanoparticles were characterized by scanning electron microscopy (SEM) and powder X-ray diffractometry (XRD). UV-vis spectrophotometry was used to analyze the photocatalytic degradation of 3-nitrophenol with ZnO nanoparticles as photocatalyst under ultraviolet irradiation at 254 nm. Evaluation of the kinetic of the photo-catalytic degradation of 3-nitrophenol indicated that the degradation of 3-nitrophenol with ZnO nanoparticles obeyed the pseudo-first order reaction rate model.

Control of Enzymatic Degradability of Microbial Polyester by Surface Modification (표면 개질을 통한 미생물합성 폴리에스테르의 효소분해속도 조절)

  • 이원기
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1315-1320
    • /
    • 2002
  • Since the enzymatic degradation of microbial poly[(R)-3-hydroxybutyrate-co-3-hydroxyvalerate] (P(3HB-co-3HV)) initially occurs by a surface erosion process, a degradation behavior could be controlled by the change of surface property. In order to control the rate of enzymatic degradation, plasma gas discharge and blending techniques were used to modify the surface of microbial P(3HB-co-3HV). The surface hydrophobic property of P(3HB-co-3HV) film was introduced by CF$_3$H plasma exposure. Also, the addition of small amount of polystyrene as a non-degradable polymer with lower surface energy to P(3HB-co-3HV) has been studied. The enzymatic degradation was carried out at 37 $^{\circ}C$ in 0.1 M potassium phosphate buffer (pH 7.4) in the presence of an extracellular PHB depolymerase purified from Alcaligenes facalis T1. Both results showed the significant retardation of enzymatic erosion due to the hydrophobicity and the enzyme inactivity of the fluorinated- and PS-enriched surface layers.