• 제목/요약/키워드: Degradation product

검색결과 454건 처리시간 0.023초

Biodegradation of Trichloroethylene by Phenol-degrading Pseudomonas putida

  • Shin, Hyun-Jae;Lee, Moo-Yeal;Yang, Ji-Won
    • Journal of Microbiology and Biotechnology
    • /
    • 제8권2호
    • /
    • pp.185-187
    • /
    • 1998
  • Pseudomonas putida KCTC 2401 degrades 1,1, 2-trichloroethylene (TCE) using phenol as a cosubstrate. The initial TCE degradation rate decreased with the initial TCE concentration up to 20mg/l of TCE at $30^{\circ}C$ and pH 6.5. The initial degradation rate and total removal efficiency increased with inoculum size. The strain also degraded dichloroacetic acid, which was supposed to be a degradation by-product. Phenol monooxygenase apparently participates in the TCE degradation mechanism.

  • PDF

부탄 이용 미생물에 의한 MTBE(Methyl tert-Butyl Ether) 분해 특성

  • 장순용;백승식;이시진
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.136-139
    • /
    • 2001
  • In this study, we have examined potential degradation of MTBE (methy1 tert-butyl ether) by pure culture ENV425 and mixed culture isolated from gasoline contaminated soil using n-butane as the sources of carbon and energy. The results described in this study suggest that MTBE is degraded cometabolically by ENV425 and mixed culture grown n-butane, and the disappearance of TBA after complete degradation of MTBE suggest the further degradation of TBA. Butane and MTBE degradation was completely inhibited by acetylene, which indicated that both substrates were degraded by butane-utilizing bacteria. MTBE was degraded ENV425 and mixed culture grown n-butane, and TBA (tert-butyl alcohol) was produced as product of MTBE oxidation. TBA production was accounted 54.7% and 58.6% for MTBE oxidation by ENV425 and mixed culture, respectively. The observed maximal transformation yield (T$_{y}$) were 44.7 and 34.0 (nmol MTRE degraded/$\mu$mol n-butane Utilized) by ENV425 and mixed culture, respectively.y.

  • PDF

전기화학적 합성 Ferrate(VI)를 이용한 수중 Trichloroethylene 분해특성 연구 (Degradation of Trichloroethylene in Aqueous Phase by Electrochemical Ferrate(VI))

  • 남주희;권병혁;김일규
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.453-461
    • /
    • 2012
  • The degradation characteristics of TCE by Ferrate(VI) oxidation have been studied. Ferrate(VI) were prepared by electrochemical method. The degradation efficiency of TCE in aqueous solution was investigated at various pH values, Ferrate(VI) doses and aqueous solution temperature values. GC-ECD was used to analyze TCE. TCE was degraded rapidly by ferrate(VI) in aqueous solution, Also, the experimental results showed that TCE removal efficiency increased with the increase of Ferrate(VI) doses. The effect of pH was investigated and the maximum degradation efficiency was obtained at pH 7. And intermediate products were identified by GC-MS techniques. Ethyl Chloride, Dichloroethylene, Chloroform, 1,1-dichloropropene, Trichloroacetic acid and Trichloroethane were identified as a reaction intermediate, and $Cl^-$ was identified as an end product.

Ferrate(VI)를 이용한 Trichloroethylene의 분해특성 연구 (Degradation of Trichloroethylene by Ferrate(VI))

  • 남주희;권재현;임수빈;김일규
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.37-46
    • /
    • 2012
  • The degradation characteristics of TCE by Ferrate(VI) oxidation have been studied. The degradation efficiency of TCE in aqueous solution was investigated at various pH values, Ferrate(VI) doses, initial concentrations of TCE and aqueous solution temperature values. GC-ECD was used to analyze TCE. The optimum conditions of TCE degradation were obtained pH 7.0 and $25^{\circ}C$ in aqueous solution. Also, the experimental results showed that TCE removal efficiency increased with the decrease of initial concentration of TCE. And intermediate products were identified by GC-MS techniques. Ethyl Chloride, Chloroform, Ethylene, 1,2-dichloroethane and 1,1,2-trichloroethane were identified as a reaction intermediate, and $Cl^-$ was identified as an end product.

확률계수 열화율 모형하에서 열화자료의 통계적 분석 (Statistical Analysis of Degradation Data under a Random Coefficient Rate Model)

  • 서순근;이수진;조유희
    • 품질경영학회지
    • /
    • 제34권3호
    • /
    • pp.19-30
    • /
    • 2006
  • For highly reliable products, it is difficult to assess the lifetime of the products with traditional life tests. Accordingly, a recent approach is to observe the performance degradation of product during the test rather than regular failure time. This study compares performances of three methods(i.e. the approximation, analytical and numerical methods) to estimate the parameters and quantiles of the lifetime when the time-to-failure distribution follows Weibull and lognormal distributions under a random coefficient degradation rate model. Numerical experiments are also conducted to investigate the effects of model error such as measurements in a random coefficient model.

Mechanism of Enzymatic Degradation of Poly(butylene succinate)

  • Lee, Chan-Woo;Kimura, Yoshiharu;Chung, Jin-Do
    • Macromolecular Research
    • /
    • 제16권7호
    • /
    • pp.651-658
    • /
    • 2008
  • Poly(butylene succiate) (PBS), poly(butylene succinate-co-L-lactate) (PBSL), and poly(butylene succinate-co-6-hydroxycaproate) (PBSCL) polymers were degraded by lipase $PS^{(R)}$, and the enzymatic degradation mechanism of PBS was analyzed in detail. The enzymatic degradation of PBS gave 4-hydroxybutyl succinate (4HBS) as the main product. An exo-type hydrolysis mechanism was proposed based on this observation. The terminal chain of PBS had conformational similarity to ordinary tri- and diglycerides and could be incorporated as a substrate in the active site of this lipase. The surface adsorption of the lipase was much larger on PBS and its copolymer films than on the other polyester films because the lipase adhered quite strongly to the polymer terminal through a specific adsorption mechanism. Kinetic analysis showed that the total number of surface adsorption points per unit area of PBSL and PBSCL copolymers was larger than that of the PBS homopolymer.

Characterization of Thermal Products of Alpha-Tocopherol

  • Chung, Hee-Young
    • Preventive Nutrition and Food Science
    • /
    • 제9권4호
    • /
    • pp.295-299
    • /
    • 2004
  • Alpha-tocopherol was thermally oxidized and degraded at high temperatures and the resulting products were chromatographically separated and identified by LC-MS. Alpha-tocopherol dissolved in glycerol was heated at 200^{\circ}C for 30 min. The thermal products were separated by hexane extraction and analyzed by HPLC using a reversed phase $\mu$-Bondapak $C_{18}-column$ with two kinds of elution solvents: a mixture of acetonitrile and methanol (3:2), and of acetonitrile, methanol, 2-propanol, chloroform and methylene chloride (3:2:5:0.5:0.5) in a gradient mode. The isolated thermal. products of alpha-tocopherol were more viscous than alpha-tocopherol, and dark brown in color. Major thermal degradation products of alpha-tocopherol were identified by LC-MS, and the structures of thermal products were proposed. Alpha-tocopherol and its thermal degradation products were degraded into fragments, mainly at the non-aromatic parts. The degradation products of alpha-tocopherol. were combined with oxidized product (tocopherylquinone) to make thermal. products through dimerization.

에너지 저장 시스템 (ESS)용 배터리의 운전조건에 따른 성능 저하 및 태양광 연계형 ESS 모니터링 연구 (Performance Degradation of a Battery in an Energy Storage System (ESS) under Various Operating Conditions and Monitoring Study of ESS Connected with Photovoltaic)

  • 정윤이;정한주;정연기;이재영;이홍기
    • 한국수소및신에너지학회논문집
    • /
    • 제25권3호
    • /
    • pp.311-318
    • /
    • 2014
  • Performance degradation of a battery in 20 kWh energy storage system (ESS) under various operating conditions was studied. And energy saving of the ESS was also monitored by connecting with 20 kW photovoltaic (PV). PV-connected ESS saved 5~7% of energy consumption in 2013 compared to that without such system in 2012. As charge-discharge cycle increased, capacity decreased and the performance degradation was glaringly obvious after 40 cycles. And as charge and discharge rate increased, the performance degradation was more serious. After 50 charge-discharge cycles, a lot of degraded product was deposited on the surface of anode and cathode electrodes, and the cathode side was more contaminated. Therefore, in order to maintain the cell performance, it was more important to protect the degradation of the cathode side.

Stability of Tetracycline Hydrochloride in Reverse Micelles

  • Kim, Hyun-Joo;Lee, Hwa-Jeong;Sah, Hong-Kee
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권5호
    • /
    • pp.333-336
    • /
    • 2005
  • The objective of this study was to investigate the stability of tetracycline HCl on encapsulation into and inside reverse micelles. To do so, tetracycline HCl was first mixed with cetyltrimethylammonium bromide, water and ethyl formate to make reverse micelles. The degradation kinetics of tetracycline HCl inside the reverse micelles was then assessed by scrutinizing its stability data. Under our experimental conditions, the reverse micelles formed spontaneously in absence of any mixing devices. During the preparation of the reverse micelles, however, considerable portions of tetracycline HCl underwent a chemical reaction (e.g., epimerization). For instance, $51.4{\pm}0.6%$ of an initial concentration of tetracycline HCl was transformed into a degradation product. Once dissolved inside the reverse micelles, the degradation of tetracycline HCl followed an exponential decay pattern. The plot of log{the degradation rate of tetracycline HCl} versus log{tetracycline HCl concentration} made it possible to determine the order of degradation reaction and rate constant. It was proven that the degradation of tetracycline HCl inside the reverse micelles followed a first order kinetics with a rate constant of 0.0027 $hour^{-1}$. Meriting further investigation might be formulation studies to stabilize tetracycline HCl on encapsulation into and inside the reverse micelles.

Optimum Design of Accelerated Degradation Tests for Lognormal Distribution

  • Lee, Nak-Young
    • 품질경영학회지
    • /
    • 제23권1호
    • /
    • pp.29-40
    • /
    • 1995
  • This paper considers the problem of optimally designing accelerated degradation tests in which the performance value of a specimen is measured only at one of three test conditions for a given exposure time. For the product having lognormally distributed performance, the optimum plan-low stress level and sample proportion allocated to each test condition - is obtained, which minimize the asymptotic variance of maximum likelihood estimator of a stated quantile at design stress. An illustrative example for the optimum plan is given.

  • PDF