• Title/Summary/Keyword: Degradation factor

Search Result 972, Processing Time 0.027 seconds

A comprehensive study of the effects of long-term thermal aging on the fracture resistance of cast austenitic stainless steels

  • Collins, David A.;Carter, Emily L.;Lach, Timothy G.;Byun, Thak Sang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.709-731
    • /
    • 2022
  • Loss of fracture resistance due to thermal aging degradation is a potential limiting factor affecting the long-term (80+ year) viability of nuclear reactors. To evaluate the effects of decades of aging in a practical time frame, accelerated aging must be employed prior to mechanical characterization. In this study, a variety of chemically and microstructurally diverse austenitic stainless steels were aged between 0 and 30,000 h at 290-400 ℃ to simulate 0-80+ years of operation. Over 600 static fracture tests were carried out between room temperature and 400 ℃. The results presented include selected J-R curves of each material as well as K0.2mm fracture toughness values mapped against aging condition and ferrite content in order to display any trends related to those variables. Results regarding differences in processing, optimal ferrite content under light aging, and the relationship between test temperature and Mo content were observed. Overall, it was found that both the ferrite volume fraction and molybdenum content had significant effects on thermal degradation susceptibility. It was determined that materials with >25 vol% ferrite are unlikely to be viable for 80 years, particularly if they have high Mo contents (>2 wt%), while materials less than 15 vol% ferrite are viable regardless of Mo content.

Recommendation of Navigation Performance for K-UAM Considering Multipath Error in Urban Environment Operation

  • Sangdo Park;Dongwon Jung;Hyang Sig Jun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.4
    • /
    • pp.379-389
    • /
    • 2023
  • According to the Korea Urban Air Mobility (K-UAM) Concept of Operation (ConOps), the Global Navigation Satellite System (GNSS) is recommended as the primary navigation system and the performance specification will be implemented considering the standard of Performance Based Navigation (PBN). However, by taking into account the characteristics of an urban environment and the concurrent operations of multiple UAM aircraft, the current PBN standards for civil aviation seem difficult to be directly applied to an UAM aircraft. Therefore, by referring to technical documents published in the literature, this paper examines the feasibility of applying the proposed performance requirements to K-UAM, which follows the recommendation of navigation performance requirements for K-UAM. In accordance with the UAM ConOps, the UAM aircraft is anticipated to maintain low altitude during approach and landing phases. Subsequently, the navigation performance degradation could occur in the urban environment, and the primary degradation factor is identified as multipath error. For this reason, to ensure the safety and reliability of the K-UAM aircraft, it is necessary to analyze the degree of performance degradation related to the urban environment and then propose an alternative aid to enhance the navigation performance. To this end, the aim of this paper is to model the multipath effects of the GNSS in an urban environment and to carry out the simulation studies using the real GNSS datasets. Finally, the initial navigation performance requirement is proposed based on the results of the numerical simulation for the K-UAM.

The Influence of Pulse Frequency and Duty Factor on Surface Characteristics during Low Temperature Plasma Nitrocarburizing Treatment of Duplex Stainless Steel (Duplex Stainless Steel의 저온 플라즈마 침질탄화시 Pulse Frequency 및 Duty Factor에 따른 표면 특성평가)

  • Cheon, Chang-Seok;Lee, Insup
    • Journal of Surface Science and Engineering
    • /
    • v.47 no.5
    • /
    • pp.221-226
    • /
    • 2014
  • A low temperature plasma nitrocarburizng was implemented on the duplex stainless steel to achieve the enhancement of surface hardness without degradation of its corrosion resistance. Attempts were made to investigate the influence of Pulse frequency and Duty factor of pulsed power in a high Pulse frequency regime on the surface characteristics of the hardened layer. The hardened layer (S-phase) was formed on all of the treated surfaces. Surface hardness reached up to 1300 $HV_{0.1}$ which is about 4.6 times higher than that of the untreated material (280 $HV_{0.1}$). The thickness of the hardened layer tends to increase lightly with the higher Pulse frequency and the higher Duty factor. The corrosion resistance of nitrocarburized duplex stainless steel was almost similar to that of the untreated material. Both the Pulse frequency and the Duty factor do not have a significant influence on the corrosion property of plasma treated duplex stainless steel.

Public Building Value Evaluation Using Contingent Valuation Method Based on Market Value Estimation

  • PARK, Jieun;YU, Jungho
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.367-370
    • /
    • 2015
  • Building deterioration reflects the degradation of basic building performance including structural performance, energy performance, durability, and safety, and it also includes perceived deterioration, which considers a user-based perspective. More than 50% of the existing buildings in Korea are over 15 years old and public buildings compose 2.5% of all buildings domestically. Therefore, there are several different problems, such as poor energy efficiency, structural performance, and safety. To address the challenges of increasing stock in deteriorated buildings, it is necessary to make decisions about reconstruction or renovation. In this study, we propose a new method to evaluate public building value with a contingent valuation method (CVM). By estimating willing-to-pay (WTP) from users of private buildings in similar situation with the public building, it is possible to compare market prices and calculate a correction factor to adjust the WTP data. Finally, we apply the correction factor to the WTP of a public building and estimate market price, willingness to pay (WTP). Finally, we apply the correction factor to willing to pay (WTP) of public building and estimate market price.

  • PDF

Advanced Cathodic Protection Modeling Associated with Coating Degradation Conditions

  • Im, Gwan-Jin;Kim, Ki-Joon;Lee, Myung-Hoon
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.177-183
    • /
    • 2009
  • There are two effective methods in use to protect ship ballast tank against corrosion. One is paint coating and the other cathodic protection(CP). The conventional cathodic protection design has mainly relied on the expert's experience. During the last two decades computer modeling has been significantly developed as an advanced design technology for cathoidic protection systems not only for ships, but also for offshore structures. However the present computer modeling of cathodic protection systems have some limitations simulating corrosion in the ballast tank with a deteriorated coating. In this study, "coating breakdown factor" considering coating degradation states with time has been attempted to improve the cathodic protection modeling using the data from literatures.

Treatability Study on Oil-Contaminated Soils for Bioremediation Application (유류오염토양의 생물적용기술 적용타당성 검토)

  • Lee, Yeon-Hui;Seol, Mi-Jin;O, Yeong-Suk
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.578-581
    • /
    • 2001
  • A treatability study was conducted using a hydrocarbon-contaminated soil for the oPtimization of bioremediation strategy best fit to a given set of contamination. The applicability of nutrients, biosurfactant, and oil-degrading microorganisms were examined by monitoring $CO_2$ evolution and oil degradation The addition of inorganic nutrients in the form of slow released fertilizer accelerated the initial rate of $CO_2$ evolution by a factor of 3. The application of oil-degrading microorganisms did not significantly increased $CO_2$ evolution or biodegradation efficiency. Application of a commercial biosurfactant was most effect in terms of the total $CO_2$ evolution and the oil degradation rate. The results indicate that $CO_2$ evolution measurement was found to be a simple and reliable countermeasure of crude oil hydrocarbon mineralization for the rapid determination of the best-fit bioremediation strategy.

  • PDF

Corrosion of Alumina-Chromia Refractory by Alkali Vapors: 1. Thermodynamic Approach

  • Lee, Kyoung-Ho;Jesse J. Brown Jr
    • The Korean Journal of Ceramics
    • /
    • v.1 no.1
    • /
    • pp.29-34
    • /
    • 1995
  • Theoretical predictions were made for thermodynamically stable phases which formed when alkali(sodium and Potassium) vapors reacted with the 90% $Al_2O_3$-10% $Cr_2O_3$ refractory under coal gasifying atmosphere using the computer program of SOLGASMIX-PV. The calculation results showed that the stable compounds that formed were $X_2O$.$Al_2O_3$ and $X_2O$.$llAl_2O_3$(X=$Na^+$ or $K^+$), depending upon the alkali concentration. The presence of sulfur in gasifying atmospheres did not appear to affect the species of alkali reaction products. Alkali attack at high temperatures is likely to cause serious degradation at the hot face of the refractory, indicating that the alkali concentration is an important factor to affect the degradation of the refroctory.

  • PDF

Change of the Characteristics of ZnO Arrester Blocks by Lightning Impulse Current (산화아연형 피뢰기 소자의 뇌충격전류에 의한 특성 변화)

  • Han, Joo-Sup;Song, Jae-Yong;Kil, Gyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.907-909
    • /
    • 1998
  • This paper describes the effect of impulse current on degradation of ZnO blocks. In this study, an impulse current generator which can produce 8/20 [${\mu}s$], 3 [kA] and 4/10 [${\mu}s$], 5 [kA] waveform is designed and fabricated to simulate the lightning impulse current. The residual voltage, reference voltage, and leakage current flowing to the ZnO blocks are observed. The experimental results show that the leakage current increases continuously with the number of applied impulse current, but no significant changes in residual voltage and in operating voltage are observed until the ZnO block is destroyed. Also, it is confirmed that the main factor on degradation of ZnO blocks is rather the total energy applied to ZnO blocks than the peak value of the impulse current.

  • PDF

Cell-Interactive Polymers for Tissue Engineering

  • Lee, Kuen Yong;Mooney, David J.
    • Fibers and Polymers
    • /
    • v.2 no.2
    • /
    • pp.51-57
    • /
    • 2001
  • Tissue engineering is one exciting approach to treat patients who need a new organ or tissue. A critical element in this approach is the polymer scaffold, as it provides a space for new tissue formation and mimics many roles of natural extra-cellular matrices. In this review, we describe several design parameters of polymer matrices that can significantly affect cellular behavior, as well as various polymers which are frequently used to date or potentially useful in many tissue engineering applications. Interactions between cells and polymer scaffolds, including specific receptor-ligand interactions, physical and degradation feature of the scaffolds, and delivery of soluble factors, should be considered in the design and tailoring of appropriate polymer matrices to be used in tissue engineering applications, as these interactions control the function and structure of engineered tissues.

  • PDF

Reductive Dechlorination of Chlorinated Oraganic Compounds Using Zero-Valent Iron (0가 철분을 이용한 유기염소화합물의 환원적 탈염소화)

  • Lee, Chang-soo;Bae, Woo-keun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.4
    • /
    • pp.427-432
    • /
    • 2001
  • The purpose of study is to examine the sensitivity of the rate of degradation to initial TCE concentration and iron concentration in the solution. The batch tests were executed to assess the degradation rate at varying initial conditions. First order rate constants($k_a$) were more rapid with the lower initial TCE concentration, Howere the correleation was not always linear between $k_a$ and initial TCE concentration. $k_a$ was proportionally increased as the increasing surface area. It implied that the effective reactive surface area acted as the limiting factor on the reductive dechlorination of TCE by iron.

  • PDF