• Title/Summary/Keyword: Degradation Time

Search Result 2,830, Processing Time 0.031 seconds

광촉매 반응에 의한 환경호르몬 분해특성

  • 박재홍;안상우;장순웅
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.358-361
    • /
    • 2004
  • The photocatalytic degradation of Endocrine Discruptors, dibuthyl phthalate(DBP) has been investigated over TiO$_2$ photocatalysts irradiated with a ultraviolet (UV) light. The effect of operational parameters, i.e., reaction time, light intensity, pH and additive on the degradation rate of aqueous solution of Endocrine Discruptors has been examined. Results show that the employment of efficient photocatalysts and the selection of optimal operational parameters may lead to degradation of Endocrine Discruptors solutions.

  • PDF

An Accelerated Degradation Test of a Electronics Appliance Compressor (전자제품용 컴프레서의 가속열화시험에 관한 연구)

  • Lee, Hoo-Jin;Yun, Won-Young
    • Journal of Applied Reliability
    • /
    • v.10 no.1
    • /
    • pp.25-38
    • /
    • 2010
  • In this paper, an accelerated degradation test procedure for an electronic appliance compressor is proposed. We investigate the amount of wear of the compressor and consider several factors as accelerating factors. Finally we select the operating pressure as a main accelerating factor. The test condition of accelerated degradation test is determined. The modified accelerating test reduces the test time in design phase by using the suggested accelerating factor.

On the Degradation of a UWB System Due to a Realistic TX-RX Antenna System

  • Jun, Min-Sik;Oh, Tae-Won
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.453-456
    • /
    • 2005
  • The ultra-wideband (UWB) signal radiation process in an antenna is different from that of a narrowband signal. In this paper, we study the degradation of the desired signal component according to the antenna structure and location of a receiver in a bipolar time-hopping UWB system. And we propose a receiver structure with an adaptive template waveform generator to compensate for the degradation caused by a realistic TX-RX antenna system.

  • PDF

Evaluation of Material Degradation Using Electrical Resistivity Method (전기비저항법을 이용한 재료열화 평가)

  • Kim, Jeong-Pyo;Bae, Bong-Kook;Kim, Dong-Joong;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.129-136
    • /
    • 2001
  • The remaining life estimation for the aged components in power plants as well as chemical plants are very important beacuse mechanical properties of the components are degraded with time of service exposure in high temperature. Since it is difficult to take specimens from the operating components to evaluate mechanical properties of components, nondestructive techniques are needed to estimate the degradation. In this study, test materials with 4 different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C$. And the DC potential drop method and destructive methods such as tensile, $K_{IC}$ and hardness tests were used in order to evaluate the degradation of 1Cr-1Mo-0.25V steels. The objective of this study is to investigate the possibility of the application of DCPD method to estimate the material degradation, and to analyse the relationship between the electrical resistivity and the degree of material degradation.

  • PDF

Hydrolytic Stability of Sulfonic Acid-Containing Polyimides for Fuel Cell Membranes

  • Kim Hyoung-Juhn;Litt Morton H.;Shin Eun-Mi;Nam Sang Yong
    • Macromolecular Research
    • /
    • v.12 no.6
    • /
    • pp.545-552
    • /
    • 2004
  • The long-term stability of sulfonic acid-containing polyimides has been investigated. The hydrolytic degradation of homopolyimide and the block copolyimide comprising $27\;mol\%$ of 2,2'-bis(trifluoromethyl)benzidine and $9\;mol\%$ of m-phenylenediamine (BTFMB27mPl0[7/(3+1)]), was quantified through viscosity measurements and FT-IR spectroscopic analyses. The viscosity decrease with respect to time and the degradation rate were similar. The degrees of degradation with respect to time under ambient conditions and at elevated temperature in water were monitored by FT-IR spectroscopy. A new absorption peak was observed at $1786\;cm^{-1},$ which we corresponds to the presence of anhydride end groups formed by hydrolytic scission of the imide rings.

Basic Study of Degradation Test for Magnetic Contactors and Reliability Centered Maintenance

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.441-444
    • /
    • 2007
  • The mechanical endurance is the critical characteristic of Magnetic contactors (MCs), which are widely used in such industrial equipments as elevators, cranes, and factory control rooms in order to close and open the control circuit. Testing time, however, is so long in most cases that some method of reducing the testing period is required. Therefore, the degradation test by the detected vibration of MCs is developed to reduce the testing time in this work. The degradation test data are analyzed and the prediction model is provided. Also, the possibility of this technology for Reliability Centered Maintenance (RCM) will be shown. This will reduce the period of the product development and raise the reliability of the equipment in power distribution.

Degradation Estimation Of Material by Barkhausen Noise Analysis (바크하우젠 노이즈 해석에 의한 재료의 열화도 평가)

  • Lee Myung Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.38-46
    • /
    • 2005
  • The destructive method is reliable and widely used for the estimation of material degradation but it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. In this study, various nondestructive evaluation(NDE) parameters of the Barkhausen noise method, such as MPA(Maximum Peak Amplitude), RMS, IABNS(Internal Area of Barkhausen Noise on Signal) and average amplitude of frequency spectrum are investigated and correlated with thermal damage level of 2.25cr-1.0Mo steel using wavelet analysis. Those parameters tend to increase while thermal degradation proceeds. It also turns out that the wavelet technique can help to reduce experimental false call in data analysis.

Statistical Analysis of Degradation Data under a Random Coefficient Rate Model (확률계수 열화율 모형하에서 열화자료의 통계적 분석)

  • Seo, Sun-Keun;Lee, Su-Jin;Cho, You-Hee
    • Journal of Korean Society for Quality Management
    • /
    • v.34 no.3
    • /
    • pp.19-30
    • /
    • 2006
  • For highly reliable products, it is difficult to assess the lifetime of the products with traditional life tests. Accordingly, a recent approach is to observe the performance degradation of product during the test rather than regular failure time. This study compares performances of three methods(i.e. the approximation, analytical and numerical methods) to estimate the parameters and quantiles of the lifetime when the time-to-failure distribution follows Weibull and lognormal distributions under a random coefficient degradation rate model. Numerical experiments are also conducted to investigate the effects of model error such as measurements in a random coefficient model.

NIIRS ESTIMATION USING THE GENERAL IMAGE-QUALITY EQUATION FOR MONITORING IMAGE DEGRADATION

  • Kim, Dong-Wook;Kim, Tae-Jung;Kim, Hee-Seob
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.53-56
    • /
    • 2008
  • Generally, the quality of satellite images is expressed by GSD (Ground Sample Distance), MTF (Modulation Transfer Function) and SNR (Signal to Noise Ratio). However, these factors are technology-oriented and do not explain interpretability of satellite images. We need a standardized index which shows standard of interpretability. In this study, we estimated NIIRS (National Imagery Interpretability Rating Scale) through the GIQE (General Image Quality Equation) which is able to judge image interpretability with the standardized index. Traditionally, NIIRS has been determined manually by specialized image analysts. We used the GIQE in order to reduce inefficiency and high costs cause by manual interpretation and to produce accurate NIIRS. For monitoring image degradation, we estimated GIQE physical parameters from image analysis and carried out time series analysis about the quality of the KOMPSAT-1 images. On all of the tests, we were able to identify the image degradation due to the changing time. This indicates that NIIRS derived from GIQE will be used for image degradation indicator.

  • PDF

Estimate of Insulated Degradation Propertied Of EPR cable (EPR 케이블의 절연열화 특성의 평가)

  • Lee, Sung-Il;Ryu, Sung-Lym;Kim, Gui-Yeul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.233-236
    • /
    • 2002
  • This paper describes the properties of between the residual voltage for ${\gamma}$-irradiated in electric power cable using in nuclear power generating station. As these properties related with ${\gamma}$-irradiation dose, it is suggested that these properties can be utilized as a index of irradiation degradation. From theory and experiment We found the residual voltage is not influenced by cable length. We found that residual voltage of basic composite and practical composite have not a difference an occasion be the same cable length. As the ratio of degradation increases, the residual voltage in the initial time range increases and the peak moves to the shorter time. Therefore, We can know the degree of radiation degradation from the position of the peak.

  • PDF