• Title/Summary/Keyword: Degradation Curve

Search Result 253, Processing Time 0.03 seconds

Corrosion-Fatigue Reliability-Based Life Cycle Cost Analysis of High-Speed Railway Steel Bridges (고속철도 강교량의 부식.피로신뢰성 기반 생애주기비용 분석)

  • Jeon, Hong-Min;Sun, Jong-Wan;Cho, Hyo-Nam
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1132-1140
    • /
    • 2007
  • As it recently appears that Life Cycle Cost Analysis may be considered as new methodology for economic valuation of infrastructure many researches have been made to assess LCC(Life Cycle Cost) of each facility based on a reasonable methods. In general, LCC is composed of construction cost and expected maintenance repair cost. And especially, maintenance repair cost must be estimated to enhance the reliability through systematic and reasonable methods. However in Korea, because high speed railway steel bridges are recently constructed no direct statistical data are available for the account of the maintenance cost and then their maintenance characteristics are not linear yet. Therefore, the approach proposed in the paper utilizes a theoretical determination and degradation of the corrosion and fatigue of the bridges based on Rahgozar et al.(2006)'s model on fatigue notch factor considering into the corrosion to incorporate the corrosion effect into the fatigue strength reduction model. And then, the corresponding probability of failure is calculated in terms of the reliability index using S-N curve to formulate the fatigue limit state. Therefore, this paper proposes the minimum Life Cycle Cost through optimum maintenance plan analysis of high-speed railway steel bridges under construction. Finally, this paper reviews the proposed model in oder to confirm the applicability and feasibility by appling it to high speed railway steel bridges under construction

  • PDF

Relationship Between Image Quality and Changes in Spation Resolution for the Gamma Camera (감마카메라의 공간분해능 변화와 화질과의 관계)

  • Lee, Man-Koo;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.77-81
    • /
    • 2002
  • The purpose of this study is to examine quantitatively the relationship between visual image quality and degradation In spatial resolution for a gamma camera by the increase in distance from collimator. The relationship between the portion(p) of images identified the difference of image quality and the difference(${\Delta}FWHM$) in FWHM between paired images was showed in a sigmoid curve. Using Dendy's method, minimum level to be correctly identified the difference of Image duality on three out of four occasion(p=0.75) was corresponded to 0.4 mm in ${\Delta}FWHM$. Using fuzzy theory, the level to be identified the difference of image quality was examined under various conditions. The truth-value of fuzzy sets-degraded or slightly degraded and not-degraded in image quality between palled Images-was gained the peak at 0.5 mm of ${\Delta}FWHM$. It was founded that changes of $0.4{\sim}0.5\;mm$ in FWHM-corresponding about 2 cm distance from collimator could be sufficiently identified in the difference of image quality.

  • PDF

미세조류의 Methane 발효특성

  • 강창민;최명락
    • Microbiology and Biotechnology Letters
    • /
    • v.24 no.5
    • /
    • pp.597-603
    • /
    • 1996
  • This study was carried out to examine degradation characteristics of microalgae Chlorella vulgaris in methane fermentation. We measured COD and VS reduction, gas and methane productivity, VFA (volatile fatty acid), respectively. Then we calculated material balance and hydrolysis rates in soluble and solid material. The substrate concentration was controlled from 14 gCOD$_{cr}$/l to 64 gCOD$_{cr}$/l in batch cultures, and HRT (hydraulic retention time) controlled from 2 days to 30 days in continuous experi- ments. The results were as follows. In batch culture, accumulated gas productivity increased with the increase of the substrate concentration. The SS and VSS was removed all about 30% increase of substrate concentration and the most of the degradable material removed during the first 10 days. The curve of gas and methane production rate straightly increased until substrate concentration is 26 gCOD$_{cr}$/l. In continuous culture experiments, the removal rates at HRT 10days were 20% for total COD and TOC, respectively. At longer HRT, there was no increase in the removal efficiency. At HRT 15 days, the removal rates were 30% for SS and VSS, respectively. Soluble organic materials were rapidly degraded, and so there was no accumulated. Soluble COD concentration was not increase regardless of HRT-increasing. That meaned the hydrolysis was one of the rate-limiting stage of methane fermentation. The first-order rate constants of hydrolysis were 0.23-0.28 day$^{-1}$ for VSS, and 0.07-0.08 day$^{-1}$ for COD.

  • PDF

An Experimental Analysis of the Ripple Current Applied Variable Frequency Characteristic in a Polymer Electrolyte Membrane Fuel Cell

  • Kim, Jong-Hoon;Jang, Min-Ho;Choe, Jun-Seok;Kim, Do-Young;Tak, Yong-Sug;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.82-89
    • /
    • 2011
  • Differences in the frequency characteristic applied to a ripple current may shorten fuel cell life span and worsen the fuel efficiency. Therefore, this paper presents an experimental analysis of the ripple current applied variable frequency characteristic in a polymer electrolyte membrane fuel cell (PEMFC). This paper provides the first attempt to examine the impact of ripple current through immediate measurements on a single cell test. After cycling for hours at three frequencies, each polarization and impedance curve is obtained and compared with those of a fuel cell. Through experimental results, it can be absolutely concluded that low frequency ripple current leads to long-term degradation of a fuel cell. Three different PEMFC failures such as membrane dehydration, flooding and carbon monoxide (CO) poisoning that lead to an increase in the impedance magnitude at low frequencies are simply introduced.

Hydrazine Doped Graphene and Its Stability

  • Song, MinHo;Shin, Somyeong;Kim, Taekwang;Du, Hyewon;Koo, Hyungjun;Kim, Nayoung;Lee, Eunkyu;Cho, Seungmin;Seo, Sunae
    • Applied Science and Convergence Technology
    • /
    • v.23 no.4
    • /
    • pp.192-199
    • /
    • 2014
  • The electronic property of graphene was investigated by hydrazine treatment. Hydrazine ($N_2H_4$) highly increases electron concentrations and up-shifts Fermi level of graphene based on significant shift of Dirac point to the negative gate voltage. We have observed contact resistance and channel length dependent mobility of graphene in the back-gated device after hydrazine monohydrate treatment and continuously monitored electrical characteristics under Nitrogen or air exposure. The contact resistance increases with hydrazine-treated and subsequent Nitrogen-exposed devices and reduces down in successive Air-exposed device to the similar level of pristine one. The channel conductance curve as a function of gate voltage in hole conduction regime keeps analogous value and shape even after Nitrogen/Air exposure specially whereas, in electron conduction regime change rate of conductance along with the level of conductance with gate voltage are decreased. Hydrazine could be utilized as the highly effective donor without degradation of mobility but the stability issue to be solved for future application.

Evaluation of Mechanical Properties and Microstructure of Thermally Aged 308 and 316L Stainless Steel Welds (가속 열시효에 따른 308 및 316L 스테인리스강 용접부의 기계적 물성 및 미세구조 평가)

  • Kong, Byeong Seo;Hong, Sunghoon;Jang, Changheui;Kim, Maan-Won
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.1
    • /
    • pp.92-100
    • /
    • 2017
  • Due to the presence of ferrite phase in the finished welds, austenitic stainless steel welds (ASSWs) are considered susceptible to the thermal aging embrittlement during long-term service in light water reactor environment. In this study, the thermal aging embrittlement of typical ASSWs, E308 and ER316L welds, were evaluated after the long-term exposure up to 20,000 h at $400^{\circ}C$, which is considered as an accelerated thermal aging condition. After thermal aging, the decrease of tensile ductility and fracture toughness was observed. The microstructure observation with high resolution transmission electron microscopy revealed that spinodal decomposition in ferrite phase of both E308 and ER316L welds would be the main cause of the degradation of mechanical properties. Also, it was shown that the difference of thermal ageing embrittlement between ER316L and E308 welds was significant, such that the reduction of fracture resistance for ER316L weld was much larger than that of E308 weld.

Analysis of Inner Temperature in High Strength Concrete under Standard Temperature-time Curve (표준화재곡선에 의한 고강도 콘크리트 부재의 내부온도 예측)

  • Song, Hun;Lee, Sea-Hyun;Mun, Kyung-Ju;Do, Jeong-Yun;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.469-472
    • /
    • 2005
  • With all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Normally, the degradation of concrete member exposed to fire is largely dependent on the fire scale and fire condition. There is therefore a need to precisely predict the deterioration and fire damage of the exposed member. Thus, this work estimated the temperature distribution inside a member taking into consideration of the thermal properties by means of finite element method(FEM). The estimation results in a little higher prediction value than the experimental value in surface layer and is almost coincident with the experiment as the heating depth increase. From this work it can be known that the simulation application of FEM using the thermal properties of concrete member in high temperature gives rise to the confident prediction in the prediction of temperature distribution.

  • PDF

Accelerated Tensile Creep Test Method of Geosynthetics for Soil Reinforcement (보강용 지오신세틱스의 가속 인장 크리프 시험방법)

  • Koo, Hyun-Jin;Cho, Hang-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.196-203
    • /
    • 2008
  • Durability of geosynthetics for soil reinforcement is accounted for creep and creep rupture, installation damage and weathering, chemical and biological degradation. Among these, the long-term creep properties have been considered as the most important factors which are directly related to the failure of geosynthetic-reinforced soil(GRS). However, the creep test methods and strain limits are too various to compare the test results with each other. The most widely used test methods are conventional creep test, time-temperature superposition and stepped isothermal method as accelerated creep tests. Recently developed design guidelines recommend that creep-rupture curve be used to determine the creep reduction factor($RF_{CR}$) which is a conservative approach. In this study, the different creep test methods were compared and the creep reduction factors were estimated at different creep strain limits of 10% of total creep strain and creep rupture. In order to minimize the impact of creep strain to the GRS structures, the various creep reduction factors using different creep test methods should be investigated and then the most appropriated one should be selected for incorporating into the design.

  • PDF

Electrical and Structural Properties of Ferroelectric $LiNbO_3$ Thin films for Nonvolatile Memory applications (비휘발 메모리소자응용을 위한 강유전체 $LiNbO_3$ 박막의 전기적 구조적 특성에 관한 연구)

  • 최유신;정세민;김도영;이준신
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.235-238
    • /
    • 1998
  • Ferroelectric $LiNbO_3$ thin films were grown directly on Si(100) substrates by 13.55MHz RF magnetron sputtering system using a ceramic target ($Nb_2O_5/Li_2C0_3$ = 51.4/48.6). Because high temperature process have to avoided to prevent degradation of the interface (insulator/Si), $LiNbO_3$ thin films were deposited below $300^{\circ}C$. After as-deposited films were performed RTA treatments in an oxygen ambient at $600^{\circ}C$ for 60s, electrical measurements performed films before and after anneal treatment. In high field region, the leakage current density of the films after annealing was deceased about 4order and the resistivity of these was increased to about 5\times 10^{11} \Omega \cdot cm$ at 500kV/cm. In accumulation region of C-V curve, we calculated dielectric constant of thin film $LiNbO_3$ as 27.9 which is close to that of bulk value.

  • PDF

Fluorimetric Determination of Dichloroacetamide by RPLC with Postcolumn Detection

  • Choi, Yong-Wook;Reckhow, David A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.900-906
    • /
    • 2004
  • An RPLC-postcolumn detection method has been developed for the fluorimetric determination of dichloroacetamide (DCAD) in water. After ammonia and DCAD were separated on a $C_{18}$ nonpolar stationary phase with 2.5% methanol-0.02 M phosphate buffer at pH 3, the column eluant was reacted with post column reagents, o-phthaldialdehyde (OPA) and sulfite ion at pH 11.5, to produce a highly fluorescent isoindole fluorophore, which was measured with a fluorescence detector ( ${\lambda}_{ex}$ = 363 nm, ${\lambda}_{em}$ = 425 nm). With the optimized conditions for RPLC and the postcolumn derivatization, the calibration curve was found to be linear in the concentration ranges of 0.5 and 20 ${\mu}$M for DCAD, and the detection limit for DCAD was 0.18 ${\mu}$M (23${\mu}$g/L). This corresponded to 18 pmol per 100 ${\mu}$L injection volume for a signal-to-noise ratio of 3, and the repeatability and reproducibility of this method were 1.0% and 2.5% for five replicate analyzes of 2 ${\mu}$M DCAD, respectively. The degradation yields DCAD to ammonia were 94 and 99%, and the percent recoveries of DCAD from 4 and 6 ${\mu}$M DCAD-spiked tap water were shown mean more than 97%.