• Title/Summary/Keyword: Defrosting

Search Result 86, Processing Time 0.036 seconds

Effects of Coal Fly Ashes on Growth and Yields of Malting Barley in Soils of Paddy-Upland Rotation Culture (석탄회(石炭灰) 시용(施用)이 논 맥주보리의 생육(生育)과 수량(收量)에 미치는 영향)

  • Ha, Ho-Sung;Min, Gee-Sik;Jo, In-Sang;Shin, Jae-Sung;Kang, Ui-Gum
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.2
    • /
    • pp.151-157
    • /
    • 1998
  • Fly ash application with a rate of 0, 50, 100, $150Mg\;ha^{-1}$ in clay loam paddy, which had properties of pH 5.3 and low contents of silicate and boron, gave a strongly positive effects on the growth and yields of malting barley showing better responses in bituminous coal fly ash(BCFA) than anthracite fly ash(AFA). Especially, soil chemical characteristics improved greatly by fly ash were pH, available phosphate, exchangeable calcium, available silicate, and boron. Shoot length and the number of tiller till defrosting season appeared the most positive responses by application of BCFA $50Mg\;ha^{-1}$ and AFA $100Mg\;ha^{-1}$. However, the number of spikelet per panicle at heading stage was proportionally increased to the rates of each fly ash. As a result, the grain yields of malting barley were increased to $13.8(4.221Mg\;ha^{-1}){\sim}37.7%(5.106Mg\;ha^{-1})$ by application of BCFA and to $1.1(3.75Mg\;ha^{-1})-20.6%(4.473Mg\;ha^{-1})$ by application of AFA. Protein contents in the grain was the highest in $150Mg\;ha^{-1}$ plot, showing 10.5 and 10.8% by BCFA and AFA application, which were suitable for malting. At harvesting, plants showed 49 and 58% of lodging indices by application of BCFA 100 and $150Mg\;ha^{-1}$, respectively, which were equivalent to two fold values of those by AFA.

  • PDF

The Comparison and Distribution of Temperatures Established in Display Stands and Food Surfaces for Cold and Frozen Foods in large Discount Stores in Korea (대형할인매장에서의 냉장.냉동식품 판매대의 설정온도와 판매식품 표면온도 비교 및 온도분포 분석)

  • Choi, Moon-Sil;Choi, Jeong-Ae;Kim, Mee-Hye;Bahk, Gyung-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.308-314
    • /
    • 2011
  • This study surveyed and compared the temperatures established in display stands and food surfaces for cold and frozen foods in large discount stores in Korea. The temperatures established in display stands for cold food ranged with $3.5{\pm}1.8^{\circ}C$ as mean, minimum and maximum were $0^{\circ}C$ and $7^{\circ}C$. However, the surface temperatures of cold food on sale ranged with $10.7{\pm}2.9^{\circ}C$ as a mean, minimum $4.6^{\circ}C$ and maximum $18.4^{\circ}C$. Totally, the surface temperature of cold food on sale was $7.2^{\circ}C$, as a mean, higher than established in display stands for cold food in large discount stores in Korea. 53% of the surveyed cold foods were more than $10^{\circ}C$ in surface temperature and only 47% was less than $10^{\circ}C$. The differences between temperatures were lowest in fruits, salads and vegetables, but highest in milk products. On the other hand, the temperatures established in display stands for frozen food showed a range with $-20.7{\pm}1^{\circ}C$ as a mean. However, the surface temperatures of frozen food on sale showed a range with $-15.4{\pm}5^{\circ}C$ as a mean, minimum $-28^{\circ}C$ and maximum $-4.6^{\circ}C$ (included defrosting). The surface temperatures of frozen food, frozen meats, frozen processed foods and ice creams were $-13.8^{\circ}C$, $-15.9^{\circ}C$, and $-16.8^{\circ}C$, respectively. Only 32.3% of surveyed frozen foods showed less than $-18^{\circ}C$ in surface temperature. In conclusion, the temperatures established on cold and frozen food display stands were less than those of cold and frozen food surfaces on sale. There was also much variation in food surface temperatures during cold and frozen food storage and sales. Therefore, a temperature management system technology use at the distribution level for cold and frozen foods will be developed.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

A Study on the Effect of Sample Storage Condition on the RIA Results of Plasma renin activity Test (Plasma renin activity 검사의 검체 보관 방법이 방사면역 측정법 결과에 미치는 영향에 대한 고찰)

  • Choe, Jin-joo;Back, Song-ran;Yoo, Seon-hee;Lee, Sun-ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.29-33
    • /
    • 2021
  • Purpose Plasma renin activity (PRA) test is important for the diagnosis of primary aldosteronism. PRA is an easily deformed substance in vitro and affected by temperature changes. Laboratory of ASAN medical center has consistently found that there was a difference between the initial and re-experimental results. We compared and analyzed the differences in PRA test results according to the sample storage status. Materials and Methods The measurement of PRA was performed by using the radioimmunoassay. From August to September 2020, 43 PRA re-test samples were tested with different sample storage condition. The first group was re-examined by freezing the plasma-separated samples at -18℃, and the second group was re-examined with refrigerated EDTA sample. Also, additional tests were conducted on 13 PRA samples to verify the effect on thawing temperature differences in plasma-separated samples. The same samples were divided into two parts and stored frozen at -18℃, respectively, and thawing samples in room temperature and those in refrigerator were were conducted. Each result was compared and analyzed based on the initial experimental results. Results The results of re-examination after frozen storing plasma separation samples showed a lower correlation than the results of re-examination with EDTA plasma samples in refrigerator. When calculating the percentage based on the initial test results, the average percentage of each was 404.9% and 133.8%. The correlation coefficient was also R=0.8501 and R=0.9966, respectively, showing a higher correlation between plasma in the refrigerated sample EDTA tube. In comparison experiments with differences in thawing temperature, average percentage of the results of initial test and room temperature thawing was 94.3% and the average percentage of the results of refrigerated thawing was 88.0%. After again freezing the sample, the average percentage of the second room temperature thawing result is 107.5%, and the second refrigerated thawing group is 112.7%. Both groups showed an increase from first thawing. Conclusion A comparative analysis of retesting according to differences in sample storage methods in PRA tests showed a higher correlation between the results of retesting of the refrigerated EDTA plasma. And repeated freezing and melting of plasma separation samples, regardless of temperature during defrosting, has been shown to affect results. Therefore, retest of PRA should re-collect plasma from original EDTA plasma to increase reproducibility.

Investigation of Food Safety Knowledge, Attitudes, and Behavior for Analyzing Food Safety Risk Factors in the Elderly (노인들의 식품안전 위험요인 규명을 위한 식품위생 지식, 태도, 행동 조사)

  • Choi, Jung-Hwa;Lee, Yoon-Jin;Lee, Eun-Sil;Lee, Hye-Sang;Chang, Hye-Ja;Lee, Kyung-Eun;Yi, Na-Young;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.5
    • /
    • pp.746-756
    • /
    • 2016
  • The purpose of this study was to investigate food safety knowledge, food safety attitudes, and handling behavior in the elderly. The survey was conducted on 358 individuals over 65 years old in urban and rural areas. Data were analyzed with descriptive analysis and ${\chi}^2$ test analysis of variance using SPSS. From the results on elderly's food safety knowledge, the item 'tangerines should be washed before eating' was correctly answered by urban subjects (75.4%) than rural subjects (49.7%). 'Is it okay to cook meat left on the sink since afternoon in the evening' showed the lowest correct answer rate in both urban (23.1%) and rural (31.9%) subjects. For the item related to food keeping, 'Bacterial cells do not multiply in Samgyetang when it is kept in a refrigerator right after boiling thoroughly', 58.5% of urban and 54.6% of rural elderly answered correctly. Most elderly people showed a tendency to think that boiled foods might be safe to eat. Secondly, for food safety attitudes, urban elderly had more proper attitude regarding the item, 'Namul is very tasty only when mixed with bare hands' (disagree rate 34.9%) than rural elderly (P<0.05)'. On the other hand, rural elderly had more positive attitudes regarding the store principle "first in, first out" compared to urban elderly (P<0.001). Thirdly, regarding food safety behaviors, only 67.9% of urban and 58.7% of rural elderly responded that they washed their hands right after answering the telephone while cooking. Exactly 33.8% of urban and 39.6% of rural older people replied 'defrost meat on top of sink or table' as the defrost method for frozen foods, showing that elderly did not recognize the risk of foodborne illness during improper defrosting at room temperature.