• 제목/요약/키워드: Defrost performance

검색결과 32건 처리시간 0.018초

하이브리드 제상 방식을 적용한 냉장고용 핀-관 열교환기의 제상 성능 평가 (Performance Evaluation of the Hybrid Defrost Process in the Fin-Tube Evaporators of Refrigerators)

  • 이수원;박용주;권래언;정영만;이재근
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.38-46
    • /
    • 2011
  • The hybrid defrost process combined with hot-gas bypass defrost and electric heater defrost was experimentally evaluated about its defrost performance in the fin-tube evaporators of household refrigerators. Also the hybrid defrost process was compared with only electric heater defrost process. The defrost efficiency of the hybrid defrost process was shown two times higher than electric heater defrost process. The defrost time of the hybrid defrost process was shorten about 10%~50% than electric heater defrost process. Thermal shock after defrost process was decreased about 50% for the case of the hybrid defrost. It was found that energy consumption ratio of defrost process was reduced up to 7.4% compared with 22.4% of electric heater defrost at the condition of $25^{\circ}C$ ambient temperature.

Modelling of a High Efficiency Refrigeration System with Heat Storage for Reverse Cycle Hot Gas Defrost

  • Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.175-181
    • /
    • 2007
  • A computer model of a high efficiency refrigeration system equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system) is presented. The model was developed based on both theoretical and empirical equations for the compressor, evaporator, condenser and the heat storage equipment. Simulations of the prototype system were carried out to investigate refrigeration system performance under various operating conditions during refrigeration cycles. The simulations of the evaporator during defrost cycles at 30 and $40^{\circ}C$ hot gas refrigerant temperature were also performed which resulted on shorter defrost time but only slight increase in defrost efficiency. These information on energy efficiency and the defrost time required are important in order to avoid excessive parasitic load and temperature rise of the refrigerated room.

전기자동차 전면유리 제상성능 개선을 위한 전산수치 해석 (Numerical Analysis for Improvement of Windshield Defrost Performance of Electric Vehicle)

  • 김현일;김재성;김명일;이재열
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.477-484
    • /
    • 2019
  • 차량에 거주하는 시간이 증가하면서 탑승자는 차량의 높은 주행성능과 더불어 쾌적하고 안정성 높은 승차 환경을 원하고 있다. 자동차 전면유리 제상성능은 운전자의 안전운전을 위해 필수적으로 요구되는 성능 중 하나이다. 자동차의 전면유리의 성에 제거 성능을 향상시키기 위해서는 제상 노즐의 형상과 같은 관련 요소들을 적절하게 설계하여야 한다. 본 논문에서는 소형 전기자동차의 제상성능 개선을 위하여 CFD 기반의 전산수치해석을 수행하였다. 자동차 전면유리에 뜨거운 공기를 분사하는 제상 노즐과 가이드 베인의 각도를 변경하면서 제상 성능해석을 수행하였다. 전산수치해석 결과, 제상노즐 각도 $70^{\circ}$ 및 가이드 베인 설치 각도 $60^{\circ}$인 경우가 가장 우수한 제상성능을 보이는 것으로 분석되었다. 해석결과를 바탕으로 제상노즐과 가이드 베인을 제작하여 제상실험을 수행하였으며, 해석결과와 실험결과가 매우 유사함을 확인할 수 있었다. 또한 실험결과, 자동차 전면유리의 성에가 20분 이내 80% 제거됨을 확인 할 수 있어, FVMSS 103 규정을 만족하는 제상성능을 확보한 것으로 판단된다.

저 착상 휜과 두 대 압축기 사이클을 이용한 히트펌프 난방성능 개선에 관한 연구 (The Experimental Study on Performance Improvement under frost conditions of the Heat Pump with Corrugate Shaped Fin and Two Compressors)

  • 황윤제;조은준;정백영;이감규
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.201-208
    • /
    • 2005
  • This study presents the experimental study on improvement of frost/defrost performance in an heat pump system with newly developed fin and multiple compressors. As multiple compressors system, the variable and single speed compressor combinations has been introduced and compared with single speed 1-compressor system in a view point of improvement of frost/defrost performance. Also, newly developed corrugate shaped fin has been compared with conventional louver shaped fin. The frost/defrost performance is defined and some parameters are compared to discuss the effect of each combination. From this experimental study, it is known that if the variable and single speed compressor combination system equipped with corrugate shaped fin, the system performance has greatly improved not only for heating capacity, but also for frost performance.

광센서를 이용한 제상제어 방법에 대한 연구 (A Study of the Defrosting Control in the Application of Photoelectric Sensors)

  • 전창덕
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.167-174
    • /
    • 2017
  • This study attempted to investigate the value of photoelectric sensors in terms of a defrost-control method. Tests were conducted in a calorimeter room under the heating with the defrost-performance test conditions described in KS C 9306. Accordingly, the photoelectric technology is a competitive defrost-control method that can precisely control the operational defrost cycle using the output voltages that are proportional to the frost height. The heating period is gradually reduced because the complex defrost-control method, for which the sensors initiate the defrosting process and the defrosting process is terminated by the time parameter, could not adjust the net defrosting time by itself. Therefore, a complex defrost-control method, for which the photoelectric sensors start the defrosting process and it is terminated by the temperature parameter, is preferred because of the adjustment of the net defrosting time. Regardless of the defrost-control method, the first defrosting cycle is activated earlier than the times that are determined in the second and third cycles and so on, because the first operation cycle can decide the characteristics of the subsequent cycle.

고효율 냉동 컨테이너의 냉각 및 제상 실험 (Experimental Study of a High Efficiency Transport Refrigeration Container under Cooling and Defrosting Conditions)

  • 문제철;;최광일;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.277-281
    • /
    • 2008
  • This paper presents the development of a high efficiency transport refrigeration system for sliced-raw fish transportation. The refrigeration system is equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system). System performance and container operating conditions are analyzed during experimental investigation on a $3,225{\times}1,740{\times}1,640\;mm$ full-scale refrigerated container under cooling and defrosting conditions. The prototype system indicates better performance in terms of shorter cooling-down time, shorter defrost time and smaller fluctuations of refrigerated container's temperature.

  • PDF

과부하 및 착.제상 조건에서 히트펌프 칠러의 난방성능에 관한 실험 연구 (Experimental Study on Heating Performance of Heat Pump Chiller under Overload, Frost and Defrost Conditions)

  • 김정석;권영철;전종균;박삼진;한화택
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.477-482
    • /
    • 2011
  • In the present study, the performance characteristics of the heat pump chiller under heating conditions were experimentally investigated. Capacity, input power and COP under overload, frost and defrost conditions were obtained. The experimental data for the heat pump chiller were measured using the air-enthalpy calorimeter and the constant temperature water bath. At overload condition, the heating capacity and COP increase about 25.7% and 19.1%, respectively. The variations of the evaporator, the compressor outlet and the condenser temperature were obtained under frost and defrost conditions. The frost and defrost period of the heat exchanger decreases about 36.0~56.1%.

제상모드에 대한 실차 내부 환기유동의 정량적 가시화 연구 (Quantitative Visualization of Ventilation Flow for Defrost Mode in a Real Passenger Car)

  • 이진평;이상준
    • 한국가시화정보학회지
    • /
    • 제8권2호
    • /
    • pp.40-44
    • /
    • 2010
  • Thermal comfort inside a passenger car has been receiving large attention in automobile industries. Especially, the performance of windshield defroster is important in the design of a car to ensure passenger comport and safety. Thereby, better understanding on the ventilation flow along the vehicle windshield is essential to evaluate the performance of windshield defroster. However, most previous studies dealt with the defrost flow using CFD (computational fluid dynamics) calculations or scale-down model experiments. In this study, a real commercial automobile was used to investigate the flow discharged from the vehicle defroster and the ventilation flow along the windshield using a PIV velocity field measurement technique. The experimental data would be useful to understand the flow characteristics in detail and also can be used to validate numerical predictions.

온도차 감지 제상법과의 비교를 통한 광센서 제상법의 타당성 검증을 위한 연구 (Feasibility of the Defrost Control by Photoelectric Technology via Comparison with the Temperature Differential Defrosting Method)

  • 전창덕;김동선
    • 설비공학논문집
    • /
    • 제26권9호
    • /
    • pp.434-440
    • /
    • 2014
  • Experiments were performed to verify if performance and characteristic curves obtained from the temperature differential defrosting method, where surface temperature is measured to judge defrosting condition, can be reproduced by the photoelectric technology where defrosting condition is judged by photoelectric sensors. The output voltage of a phototransistor and heating capacity, power consumption, and surface temperature of the outdoor heat exchanger are compared. The results showed that the photoelectric sensors can be used as a defrost control device. On-off control timings in temperature differential defrosting method are in good agreement with those predicted by the high and low threshold output voltages of the photoelectric sensor.

착상과 제상이 냉동장치의 운전특성에 미치는 영향 (Effect of Frost and Defrost on the Operating Characteristics of Refrigeration System)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제14권4호
    • /
    • pp.5-10
    • /
    • 2010
  • This study was investigated the effect on operating characteristics of apparatus according to frosting and defrosting to develop of new defrosting equipment. The results showed as following. Frost was almost removed using the defrosting equipment with roll brush type that defrosting is possible under operating condition. Also, the temperature of compressor inlet, evaporator inlet and outlet showed higher value because of heat transfer resistance of cooling pipe frost comparing with defrosting condition. And the compressor work showed 10% lower and COP was presented 24% higher values than defrosting condition. Therefore, defrosting for cooling coil of refrigeration and low temperature storage was effected on operation and performance characteristics of equipment. This highly effects on real refrigeration apparatus which is operated in year-around.