• Title/Summary/Keyword: Defocus

Search Result 72, Processing Time 0.018 seconds

Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Intraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®)

  • Hwang, Ho Sik;Shin, Hye Young;Joo, Choun-Ki
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.110-117
    • /
    • 2014
  • In this study, we objectively determined whether the ReSTOR as a multifocal IOL (intraocular lens) has a multifocal function compared to the IQ as a monofocal IOL in vivo by OQAS (Optical Quality Analysis System). Eighteen patients who had cataract surgery with implantation of ReSTOR (27 eyes) and 15 patients with IQ (21 eyes), were included inthis study. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UCNVA)and distance corrected near visual acuity (DCNVA) were measured. After setting the artificial pupil size to 3 mm, we performed 'Optical quality'. We inputted defocus diopters of (objective spherical refraction)(far), (objective spherical refraction-1.25 D)(intermediate),(objective spherical refraction-2.5 D)(near), and (objective spherical refraction-3.5 D)(very near) into 'selected spherical refraction' simulating the optical quality at far, intermediate, and near distance. We changed the pupil size to 5 mm and repeated the same measurements. The UCDVA and CDVA did not show significant differences between the 2 groups. But, the UCNVA and DCNVA of the ReSTOR group were better than those of the IQ group (p=0.000, p=0.000). For 3 mm pupil, at far distance, modulation transfer function (MTF) cut off and point spread function (PSF) width at 50% of ReSTOR were worse than those of IQ (p=0.039, p=0.020). At intermediate distance, MTF cut off, Strehl ratio and PSF width at 50% of ReSTOR were worse than those of IQ (p=0.001, p=0.001, p=0.000). At near distance, MTF cut off of ReSTOR was worse than that of IQ (p=0.033). At very near distance, MTF cut off and Strehl ratio of ReSTOR were worse than those of IQ (p=0.002, p=0.002), but PSF width at 50% of ReSTOR was better than that of IQ. For 5 mm pupil, most parameters at each distance, there was no significant difference between the 2 groups. Only PSF width at 50% of ReSTOR were worse than those of IQ at intermediate distance (p=0.013). It was impossible to show the multifocal function of ReSTOR compared to the IQ byOQAS.

Modeling of Visual Attention Probability for Stereoscopic Videos and 3D Effect Estimation Based on Visual Attention (3차원 동영상의 시각 주의 확률 모델 도출 및 시각 주의 기반 입체감 추정)

  • Kim, Boeun;Song, Wonseok;Kim, Taejeong
    • Journal of KIISE
    • /
    • v.42 no.5
    • /
    • pp.609-620
    • /
    • 2015
  • Viewers of videos are likely to absorb more information from the part of the screen that attracts visual attention. This fact has led to the visual attention models that are being used in producing and evaluating videos. In this paper, we investigate the factors that are significant to visual attention and the mathematical form of the visual attention model. We then estimated the visual attention probability using the statistical design of experiments. The analysis of variance (ANOVA) verifies that the motion velocity, distance from the screen, and amount of defocus blur affect human visual attention significantly. Using the response surface modeling (RSM), we created a visual attention score model that concerns the three factors, from which we calculate the visual attention probabilities (VAPs) of image pixels. The VAPs are directly applied to existing gradient based 3D effect perception measurement. By giving weights according to our VAPs, our algorithm achieves more accurate measurement than the existing method. The performance of the proposed measurement is assessed by comparing them with subjective evaluation as well as with existing methods. The comparison verifies that the proposed measurement outperforms the existing ones.