• 제목/요약/키워드: Defect Model

Search Result 791, Processing Time 0.028 seconds

An Effective Application of AE Technique for the Detection of Defects in Steel Girder Bridges (강판형교에서의 효율적인 결함검출을 위한 AE기법의 적용)

  • Kim, Sang Hyo;Yoon, Dong Jin;Lee, Sang Ho;Kim, Hyung Suk;Park, Young Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.287-300
    • /
    • 1997
  • In this study, an effective application method of AE technique for the detection of fatigue crack in multi-girder steel bridges has been proposed. The applicability has been examined through the laboratory works with bridge model. The proposed analytical method which evaluates the remaining fatigue lives of structural members may improve the rational determination of the priority of inspection for structural members assuming to have fatigue cracks. Laboratory tests for the application of AE technique to steel girder bridges show that the frequency bands of traffic noise are in the range between 10 show that the frequency bands of traffic noise are in the range between 100~200 kHz and the AE signal raised from fatigue cracks is concentrated around 400~500 kHz. Therefore. R30 sensor is proved to be the most suitable for the detection of cracks in steel girder bridges. A linear proportionality between the crack propagation and the frequency of AE signals has been obtained. In addition, an economic and effective source location method for steel girder bridges was studied through experiments.

  • PDF

Growth and Electrical Properties of ZnAl2Se4 Single Crystal Thin Film by Hot Wall Epitaxy (Hot Wall Epitaxy(HWE)법에 의한 ZnAl2Se4 단결정 박막 성장과 가전자대 갈라짐에 대한 광전류 연구)

  • Park, Hyangsook;Bang, Jinju;Lee, Kijung;Kang, Jongwuk;Hong, Kwangjoon
    • Korean Journal of Materials Research
    • /
    • v.23 no.12
    • /
    • pp.714-721
    • /
    • 2013
  • A stoichiometric mixture of evaporating materials for $ZnAl_2Se_4$ single-crystal thin films was prepared in a horizontal electric furnace. These $ZnAl_2Se_4$ polycrystals had a defect chalcopyrite structure, and its lattice constants were $a_0=5.5563{\AA}$ and $c_0=10.8897{\AA}$.To obtain a single-crystal thin film, mixed $ZnAl_2Se_4$ crystal was deposited on the thoroughly etched semi-insulating GaAs(100) substrate by a hot wall epitaxy (HWE) system. The source and the substrate temperatures were $620^{\circ}C$ and $400^{\circ}C$, respectively. The crystalline structure of the single-crystal thin film was investigated by using a double crystal X-ray rocking curve and X-ray diffraction ${\omega}-2{\theta}$ scans. The carrier density and mobility of the $ZnAl_2Se_4$ single-crystal thin film were $8.23{\times}10^{16}cm^{-3}$ and $287m^2/vs$ at 293 K, respectively. To identify the band gap energy, the optical absorption spectra of the $ZnAl_2Se_4$ single-crystal thin film was investigated in the temperature region of 10-293 K. The temperature dependence of the direct optical energy gap is well presented by Varshni's relation: $E_g(T)=E_g(0)-({\alpha}T^2/T+{\beta})$. The constants of Varshni's equation had the values of $E_g(0)=3.5269eV$, ${\alpha}=2.03{\times}10^{-3}eV/K$ and ${\beta}=501.9K$ for the $ZnAl_2Se_4$ single-crystal thin film. The crystal field and the spin-orbit splitting energies for the valence band of the $ZnAl_2Se_4$ were estimated to be 109.5 meV and 124.6 meV, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that splitting of the ${\Delta}so$ definitely exists in the ${\Gamma}_5$ states of the valence band of the $ZnAl_2Se_4/GaAs$ epilayer. The three photocurrent peaks observed at 10 K are ascribed to the $A_1$-, $B_1$-exciton for n = 1 and $C_{21}$-exciton peaks for n = 21.

Fabrication and pH response characteristics of LAPS(Light addressable potentiometric sensor) with electrolyte/$Si_3N_4/SiO_2$/Si structure (Electrolyte/$Si_3N_4/SiO_2/Si$ 구조의 LAPS 제작 및 pH 응답특성)

  • Chang Su-Won;Koh Kwang-Nak;Kang Shin-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.40-44
    • /
    • 1998
  • The LAPS device of fast response and high sensitivity, based on electrochemical potential difference, and its system were fabricated for the precise measurement of pH changes and its characteristic were investigated. The electrostatic variation characteristics of LAPS according to the pH changes and parameters in the device were verified through a simulation using LAPS equivalent circuit model. The LAPS device and its system were fabricated on the basis of the result of simulation. The fabricated LAPS system showed linear sensitivity (about 56 mV/pH within the range of pH 2 to pH 11. In order to overcome the defect of general urea sensor (especially slow response time), urease immobilized nitrocellulose membrane was attached on the LAPS and resulted in the very fast response time, 0.29 mV/sec, 0.86 mV/sec at urea concentration of $50{\mu}g/ml,\; 500{\mu}g/ml$, respectively. And also in order to measure the uranyl ion, the uranyl ion selective sensing membrane with calix[6]arene derivative was used and its sensitivity was 25mV/concentration decade in the wide uranyl ion concentration range of $10^{-11}M\;to\;10^{-4}M$.

EFFECTS OF LOCAL IRRIGATION AND/OR INTRAVENOUS ADMINISTRATION OF ARGATROBAN ON THROMBOSIS IN MICROVASCULAR ANASTOMOSES OF FEMORAL VEIN OF RABBIT (가토대퇴정맥에서 미세혈관문합시 Argatroban의 국소세척 및 전신투여가 혈전형성에 미치는 영향)

  • Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.4
    • /
    • pp.300-305
    • /
    • 2005
  • Purpose: For the reconstruction of maxillofacial defect created by trauma, infection, or tumor etc, the role of microvascular anastomosis or vessel graft has been increased. Many methods has been tried to increase the success rate of microvascular anastomosis. Various anticoagulants and thrombolytic agents have been used to reduce the failure rate of microvascular anastomosis and avoid re-operation. Many drugs, however, have been used in the limited cases because most of these drugs may cause complications, such as allergy, fever or systemic bleeding. This study was performed to evaluate the influence of the Argatroban on patency and thrombosis in microvascular anastomosis when it is used for local irrigation or general administration. Materials & methods: Eight mature rabbits, weighing 2kg, were used. After exposing both femoral veins, the artificial thrombotic model was made by crushing injury using a smooth needle holder, and the transverse incision were made on femoral vein. The animals were divided into 4 groups according to Argatroban administration methods; control group (n=4), topical irrigation of lumen with saline solution; experimental group 1 (n=4), topical irrigation of lumen with Argatroban saline solution; experimental group 2 (n=4), topical irrigation of lumen with heparin followed by intravenous injection of Argatroban; experimental group 3 (n=4), topical irrigation of lumen with Argatroban followed by IV of Argatroban. Microvascular anastomosis was done with 10-0 Ethilon. The patency was evaluated by empty-and-refill test 30 minutes and 3 days after microanastomosis. The thrombus formation was examined 3 days after microanastomosis by surgical microscope. The histologic findings were also examined. Results: 1. Thirty minutes after microvascular anastomosis, the patency of all experimental groups was better than that of control group, but there was no significant difference among groups. 2. Three days after microvascular anastomosis, the patency of all experimental groups was more improved than that of control group (p<0.05). There was no significant difference among experimental groups. 3. Three days after microvascular anastomosis, the amount of thrombus in all experimental groups was less than that of control group (p<0.05). There was no significant difference among experimental groups. 4. Histologically, a lot of luminal thrombus was observed around sutured area in control group. Few luminal thrombus was observed in all experimental groups. The necrotic changes were observed on the sutured vein wall in all specimens. Conclusion: These results indicate that topical irrigation and/or intravenous administration of Argatroban is effective in improving patency and preventing thrombus formation after microvascular anastomosis.

A Prediction Method of the Gas Pipeline Failure Using In-line Inspection and Corrosion Defect Clustering (In-line Inspection과 부식결함 클러스터링을 이용한 가스배관의 고장예측)

  • Kim, Seong-Jun;Choe, Byung Hak;Kim, Woosik
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.6
    • /
    • pp.651-656
    • /
    • 2014
  • Corrosion has a significant influence upon the reliability assessment and the maintenance planning of gas pipeline. Corrosion defects occurred on the underground pipeline can be obtained by conducting periodic in-line inspection (ILI). However, little study has been done for practical use of ILI data. This paper deals with remaining lifetime prediction of the gas pipeline in the presence of corrosion defects. Because a pipeline parameter includes uncertainty in its operation, a probabilistic approach is adopted in this paper. A pipeline fails when its operating pressure is larger than the pipe failure pressure. In order to estimate the failure probability, this paper uses First Order Reliability Method (FORM) which is popular in the field of structural engineering. A well-known Battelle code is chosen as the computational model for the pipe failure pressure. This paper develops a Matlab GUI for illustrating failure probability predictions Our result indicates that clustering of corrosion defects is helpful for improving a prediction accuracy and preventing an unnecessary maintenance.

Powdered Wound Dressing Materials Made from wild Silkworm Antheraea pernyi Silk Fibroin on Full-skin Thickness Burn Wounds on Rats

  • Kim, Min-Keun;Yoo, Ki-Yeon;Kwon, Kwang-Jun;Kim, Seong-Gon;Park, Young-Wook;Lee, Kwang-Gill;Jo, You-Young;Kweon, Hae-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.3
    • /
    • pp.111-115
    • /
    • 2014
  • Purpose: This study evaluated powdered burn wound dressing materials from wild silkworm fibroin in an animal model. Methods: Fifteen rats were used in this experiment. Full-thickness $2{\times}2cm$ burn wounds were created on the back of rats under anesthesia. In the two experimental groups, the wounds were treated with two different dressing materials made from silkworm fibroin. In the Control Group, natural healing without any dressing material was set as control. The wound surface area was measured at five days, seven days and 14 days. Wound healing was evaluated by histologic analysis. Results: By gross observation, there were no infections or severe inflammations through 14 days post-injury. The differences among groups were statistically significant at seven days and 14 days, postoperatively (P<0.037 and 0.001, respectively). By post hoc test, the defect size was significantly smaller in experimental Group 1 compared with the Control Group and experimental Group 2 at seven days postoperatively (P=0.022 and 0.029, respectively). The difference between Group 1 and Group 2 was statistically significant at 14 days postoperatively (P<0.001). Group 1 and control also differed significantly (P=0.002). Group 1 showed a smaller residual scar than the Control Group and Group 2 at 14 days post-injury. Histologic analysis showed more re-epithelization in Groups 1 and 2 than in the Control Groups. Conclusion: Burn wound healing was accelerated with silk fibroin spun by wild silkworm Antheraea pernyi. There was no atypical inflammation with silk dressing materials. In conclusion, silk dressing materials can be used for treatment of burn wound.

EXPERIMENTAL STUDY OF PERIPHERAL NERVE REGENERATION BY USING NON-TUBULAR NATURAL CELLULOSE MEMBRANE NERVE CONDUIT (비관형 천연 셀룰로오스막 도관을 이용한 말초신경 재생에 대한 실험적 연구)

  • Kim, Soung-Min;Lee, Jong-Ho;Lee, Suk-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.295-307
    • /
    • 2006
  • Styela clava, called non-native tunicate or sea squirt, is habitat which include bays and harbors in Korea and several sites in the sea faced world. We fabricate cellulose membrane nerve conduit (CMNC) from this native sea squirt skin, and evaluate the capacity of promoting peripheral nerve regeneration in the rat sciatic nerve defect model. After processing the pure cellulose membrane from the sea squirt skin as we already published before, CMNC was designed as a non-tubular sheet with 14 mm length and 4 mm width. Total eleven male Spraque-Dawley rats (12 weeks, weighing 250 to 300g) were divided into sham group (n=2), silicone tube grafted control group (n=3) and experimental group (n=6). Each CMNC grafted nerve was evaluated after 4, 8 and 12 weeks in the experimental group, and after 12 weeks, sciatic function was evaluated with sciatic function index (SFI) and gait analysis, and histomorphology of nerve conduit and the innervated tissues of sciatic nerve were all examined using image analyzer and electromicroscopic methods in the all groups. The regenerated axon and nerve sheath were found only in the inner surface of the CMNC after 4 weeks and became more thicker after 8 and 12 weeks. In the TEM study, CMNC grafted group showed more abundant organized myelinated nerve fibers with thickened extracellular matrix than silicone conduit grafted group after 12 weeks. The sciatic function index (SFI) and ankle stance angle (ASA) in the functional evaluation were $-47.2{\pm}3.9$, $35.5^{\circ}{\pm}4.9^{\circ}$ in CMNC grafted group (n=2) and $-80.4{\pm}7.4$, $29.2^{\circ}{\pm}5.3^{\circ}$ in silicone conduit grafted group (n=3), respectively. And the myelinated axon was 41.59% in CMNC group and 9.51% in silicone conduit group to the sham group. The development of a bioactive CMNC to replace autogenous nerve grafts offers a potential and available approach to improved peripheral nerve regeneration. As we already published before, small peptide fragment derived from the basement membrane matrix proteins of squirt skin, which is a kind of anchoring protein composed of glycocalyx, induced the effective axonal regeneration with rapid growth of Schwann cells beneath the inner surface of CMNC. So the possibilities of clinical application as a peripheral nerve regeneration will be able to be suggested.

Anti-Ionizing Radiation Effect of Selenium on Osteoporosis Model during Bone Repair Process (골다공증 모델의 뼈 재생기에 있어 셀레늄(Selenium)의 방사선 보호작용)

  • Kim, Hyun;Cho, Sang-Rae;Choe, Changyong;Seong, Hwan-Hoo
    • Journal of Embryo Transfer
    • /
    • v.30 no.3
    • /
    • pp.201-206
    • /
    • 2015
  • Selenium (Se) is an essential trace element for humans and animals, and several findings suggest that dietary Se intake may be necessary for bone health. Accumulating evidence indicates that Se compounds possess anticancer properties. Se is specifically incorporated into proteins in the form of selenocysteine and non-specifically incorporated as selenomethionine in place of methionine. This study evaluated protection by Se in the bone repair process in ovariectomized rats after irradiation. For such purpose, 80 ovariectomized female Sprague-Dawley rats were randomly divided into 4 experimental groups: ovariectomized (Ov), Ov/Se, Ov/irradiated (Irr) and Ov/ Se/Irr. A bone defect was created on the tibia of all animals 40 days after ovariectomy. Two days after surgery, only the Ov/Se and Ov/Se/Irr rats received 0.8 mg Se/kg. Three days after surgery, only the Ov/Irr and Ov/Se/Irr rats received 10 Gy of X-rays on the lower limb region. The animals were euthanized at 7, 15, 22 and 29 days after surgery to assess the repair process, which was evaluated by analysis of trabecular bone number (Masson Trichrome) and birefringence analysis (Picrosirius). It was possible to observe a delay in the bone repair process in the ovariectomized/irradiated group and similarity between the ovariectomized, Ov/ Se and Ov/Se/Irr groups. Our findings suggest that sodium selenite may influence a radioprotective effect in the bone repair of tibia of ovariectomized rats without toxicity.

Ophthalmic Findings in 547 Korean Sapsaree Dogs

  • Chae, Je-Min;Kim, Won-Tae;Jeong, Man-Bok;Yi, Na-Young;Park, Shin-Ae;Kim, Se-Eun;Park, Young-Woo;Ha, Ji-Hong;Han, Koog-Il;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.482-487
    • /
    • 2008
  • This study was performed to investigate the ophthalmic findings of the Korean traditional 'Sapsaree' dogs, and to provide ophthalmic references. Five hundred forty-seven Sapsaree dogs were randomly chosen without any criteria preference. Ophthalmic examination was performed bilaterally using ocular equipments, including slit-lamp biomicroscope, tonometer, direct and indirect ophthalmoscope. The obtained data for ophthalmic findings were analysis by the multivariate linear regression model to identify effects of sex, age and hair coat type. For congenital conditions, the incidence of persistent pupillary membrane (PPM) was the most common defect and there was present 8.8 % whereas for acquired ophthalmic diseases, cataract was the most commonly observed (3.7 %) in Sapsaree dog. Other frequent ocular finding included persistent hyaloid vessel remnant (PHVR, 6.2 %) in congenital conditions, and postinflammatory retinal degeneration (PIRD, 3.1 %) and corneal dystrophy (2.4 %) in acquired ophthalmic diseases. Only one significant effect was age of the Sapsaree for PIRD (P=0.040). There are no any significant effect for sex and hair coat types. This study will provide useful guidelines to clinicians and breeders for the basic ophthalmic information on this breed.

A Development of Defeat Prediction Model Using Machine Learning in Polyurethane Foaming Process for Automotive Seat (머신러닝을 활용한 자동차 시트용 폴리우레탄 발포공정의 불량 예측 모델 개발)

  • Choi, Nak-Hun;Oh, Jong-Seok;Ahn, Jong-Rok;Kim, Key-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.36-42
    • /
    • 2021
  • With recent developments in the Fourth Industrial Revolution, the manufacturing industry has changed rapidly. Through key aspects of Fourth Industrial Revolution super-connections and super-intelligence, machine learning will be able to make fault predictions during the foam-making process. Polyol and isocyanate are components in polyurethane foam. There has been a lot of research that could affect the characteristics of the products, depending on the specific mixture ratio and temperature. Based on these characteristics, this study collects data from each factor during the foam-making process and applies them to machine learning in order to predict faults. The algorithms used in machine learning are the decision tree, kNN, and an ensemble algorithm, and these algorithms learn from 5,147 cases. Based on 1,000 pieces of data for validation, the learning results show up to 98.5% accuracy using the ensemble algorithm. Therefore, the results confirm the faults of currently produced parts by collecting real-time data from each factor during the foam-making process. Furthermore, control of each of the factors may improve the fault rate.