• Title/Summary/Keyword: Deep well pump

Search Result 25, Processing Time 0.026 seconds

Design and performance research of a mixed-flow submersible deep well pump

  • Zhang, Qihua;Xu, Yuanhui;Cao, Li;Shi, Weidong;Lu, Weigang
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.3
    • /
    • pp.256-264
    • /
    • 2016
  • To meet the demand of higher handling capacity, a mixed-flow submersible deep well pump was designed and tested. The main hydraulic components are made of plastics, which is free of erosion, light-weight, and environment-friendly. To simplify plastic molding process, and to improve productivity, an axial-radial guide vane was proposed. To clarify its effect on the performance, a radial guide vane and a space guide vane are developed as well. By comparison, the efficiency of the pump equipped with the axial-radial guide vane is higher than the radial guide vane and is lower than the space guide vane, and its high efficiency range is wide. The static pressure recovery of the axial guide vane is a bit lower than the space guide vane, but it is much larger than the radial guide vane. Taking the cost and molding complexity into consideration, the axial-radial guide vane is much economic, promoting its popularity for the moderate and high specific speed submersible deep well pumps.

TECHNICAL INNOVATION OF FARM WELL PUMP

  • Zhang, Shaokang;Dang, Yongliang
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.217-226
    • /
    • 1993
  • As results of not selecting and using farm well pump properly , it's running regime is far away from high efficient zone and running efficiency of farm well pump is lower. The paper analyses unhealthy tendencies of technical state of diving-electric pump, deep well and centrifugal pump which are commonly used in our country. The paper also summarizes several technical innovation plans to raise efficiency : stage change plan, diameter change plan, speed change plan and synthetic technical innovation . Each plan gives a detailed introduction of designing and construction manners, through practical measuring , the synthetic efficiency of innovated well pumps raise above 30 percent. Economic benefit is evident.

  • PDF

Heating Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Development of a Sensorless Deep Well Pump Multi-function Controller using Current Detection Method (전류검출 방식의 심정 펌프 센서리스형 다기능 컨트롤러 개발)

  • Lee, In-Jae;Basnet, Barun;Chun, Hyun-Jun;Bang, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1149-1154
    • /
    • 2017
  • In this paper, we propose a sensorless multi-function controller applicable for deep well water pumps using current detection method. The proposed system overcomes various drawbacks of existing sensored system and additional features like Over current protection function due to overload, Under current protection function for idling at low water level and Relay function for starting single phase motors and acts as a level indicator to detect water lever in real time by the current detection method. A prototype of the multi-function controller system is designed and all of its functions are tested in the laboratory. The application of the proposed controller ensures reduction in the power consumption and maintenance cost in the facilities like water and septic tanks, drainage and waste water system, oil and chemical tanks where deep well pumps are used.

Rotordynamic Transient Analysis of Vertical Sea Water Lift Pump for FPSO Deep Well (FPSO 심정용 수직 해수펌프의 로터다이나믹 과도해석)

  • Kim, Byung-Ok;Yang, Sung-Jin;Lee, Myung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.69-74
    • /
    • 2011
  • This paper deals with the detail rotordynamic analysis for the vertical rotor system as development of vertical sea water lift pump for FPSO deep well. In a vertical rotor system, since linearized stiffness and damping coefficients of fluid film bearing are no longer be valid, hence the transient response analysis considering a fluid film force for every journal position in the bearing needs to be required. In this study, the transient response analysis of the proposed vertical pump rotor system was carried out in dry-run and wet-run conditions, respectively. The results show that orbital vibration responses of the rotor system remain stable at rated speed and thereby operating reliability of the vertical rotor system is confirmed. To overcome complexity of calculation pr ocedure and time consuming calculation of transient analysis, the calculating technique of steady-state response analysis is also proposed. The results of steady-state response obtained by applying the proposed technique to the rotor system are good agreement with the reference results, that is, transient responses.

A Study on Performance Evaluation of a Vertically Closed Deep Geothermal Circulation Simulator (수직 밀폐형 심부지열 순환 시뮬레이터의 성능 평가에 관한 연구)

  • Bae, Jung-Hyeong;Lee, Dong-Woon;Yoon, Chung-Man;Ryoo, Yeon-Su;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.8-17
    • /
    • 2016
  • While greenhouses have been utilized as a sustainable alternative to traditional soil farming, they are often powered by diesel boilers that necessitate vast amounts of non-renewable energy and emit toxic fumes. Thus, geothermal heat pumps have been proposed as a more energy-efficient substitution for diesel boilers. Currently, most horticultural facilities in the United States use shallow geothermal systems, and are often equipped with horizontal underground heat exchangers as well as heat pump equipment. These shallow geothermal systems require a large drilling site and heat pump to function, which results in high maintenance costs. The heat pump itself consumes a large amount of power, which degrades system performance. Conversely, high temperatures can be attained within a single borehole in deep geothermal vertical closing systems without using a heat pump. This setup can dramatically reduce the power consumption and improve system performance. In this study, we have modeled a circulation simulator after the circulation systems in deep geothermal facilities to analyze a 2000-meter borehole in Naju-Sanpo-myeon. The simulator is operated by manipulating various putative parameters affecting system performance to analyze the system's coefficient of performance.

Visualizing test on the pass-through and collision characteristics of coarse particles in a double blade pump

  • Tan, Minggao;Lian, Yichao;Liu, Houlin;Wu, Xianfang;Ding, Rong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • As the key equipment in deep ocean mining, the slurry pump suffers from wear and blocking problems. In this paper, high-speed photography technique is applied to track the movement rule of single particle of the coarse particle solid-liquid two-phase flow in a double blade slurry pump. The influences of particle diameter and particle density on the pass-through and collision characteristics of particles are analyzed as well. The results show that the average of the passing pump time first decreases and then increases when the particle diameter increases. The average of the passing pump time decreases by 22.7%, when the particle density increases from $1.09g/cm^3$ to $1.75g/cm^3$. Besides, the particle density has great influence on the location where the particle hits the tongue. Most particles of $1.09g/cm^3$ hit the tongue on the left side, while collision location of particles of $1.75g/cm^3$ is mainly on the top and at the right side of the tongue. The research can provide a basis for the optimization design of slurry pump in deep ocean mining system.

Demonstration of system to combat desertification using renewable energy (신재생에너지를 이용한 사막화 방지 시스템 실증 (몽골))

  • Kim, Man-Il;Lee, Seung-Hun;Whang, Jung-Hun;Cho, Woon-Sic;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.73-76
    • /
    • 2009
  • Generally, wind or solar power system is operated as a stand-alone power system, the efficiency of which could be higher by designing wind-solar combined system considering average wind speed and solar radiation of the desert region, Mongolia. This system is designed to generate electricity for power users and pumps the ground water for irrigation using deep well pump. The ground water can be used for farming or forestation where there is no or little irrigation system. In connection with this study, a renewable energy park, Green Eco Energy Park, was developed at about 50km east of Ulaanbaatar. 3 sets of 10kW wind power generator and 70 kW of solar power module were installed there. The electricity generated from the system is used to on-site office building and deep well pump for ground water pumping. A 10kW stand-alone solar pumping system, which has no rechargeable battery system, is installed to pump the ground water with the amount of generated power. The ground water is stored in 3 artificial ponds and then it is used for raising nursery tree and farming. The purpose of this study is to provide a possible energy solution to desert regions where there is no or little power system. The system also supply power to ground water pump, and the water can be used for farming and forestation, which will also be a solution of preventing desertification or spreading of desert area.

  • PDF

Analytical evaluation of water injection pump dynamic characteristic (물 분사 펌프 동특성의 해석적 평가)

  • Lee, JongMyeong;Lee, JeongHoon;Ha, JeongMin;Ahn, ByungHyun;Gu, DongSik;Choi, ByeongKeun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.60-64
    • /
    • 2013
  • Water injection pump produced the 1st oil well through the high pressure after the Deep water oil well drilling. After finish the work it is hard to produce only using itself pressure due to low pressure. Therefore it can be increased recovery factor through the injection seawater of high pressure. Is the key equipment used in the marine plant and it is developing at many industries. In this paper, Analyze changes in the natural frequency due to the stiffness of the bearing. Analyze the critical speed of the natural frequency due to the change of operation speed. And evaluate the Stability. And then analyze the displacement and clearance through the unbalance response this way has contributed to the reliability of the developing product. Through a mathematical analysis.

  • PDF