• Title/Summary/Keyword: Deep groundwater pumping

Search Result 16, Processing Time 0.02 seconds

Comparative Analysis of Shallow and Deep Groundwater Pumping Effects on Stream Depletion (천부와 심부지하수 양수에 따른 하천수 감소 영향의 비교분석)

  • Lee, Jeongwoo;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.383-391
    • /
    • 2020
  • In this study, Hunt's analytical solution and Ward & Lough's analytical solution for two-layered leaky aquifer system were used to estimate stream depletions due to shallow and deep groundwater pumping, and their differences were compared. Depending on the combination of the separation distance between the stream and the well, the transmissivity and the storage coefficient of the aquifer, and the leakage coefficient between the upper and lower layers, the stream depletion, which is the amount of stream water reduction compared to the amount of groundwater pumping, for each of 45,000 cases was calculated for both shallow and deep groundwater pumping, and the differences were analyzed quantitatively. When the leakage coefficient was very small, with a value of 10-61/d, the difference in the average five-year stream depletion due to the pumping of shallow and deep groundwater showed a large deviation of up to 0.9 depending on the given hydraulic characteristics; this value exponentially decreased as the stream depletion factor (SDF) increased. This exponential relationship gradually weakened as the leakage coefficient increased due to interaction effects between layers, resulting in a small difference of up to 0.2 when the leakage coefficient reached 10-31/d. Under the condition of greater interlayer hydraulic connectivity, there was little influence of the depth of groundwater pumping on the stream water reduction.

심부지하수 수질 보호를 위한 천부포획정 공법

  • 김강주;박성민;염병우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.511-514
    • /
    • 2003
  • Nowadays, wells tapping the deep aquifers become general because water quality of the shallow groundwater has been gradually degraded over the last 30 years as a result of rapid industrialization and intensive agricultural activities. However, many of the deep wells also suffer problems of water-quality degradation in several years after the well installation, nevertheless those were properly completed and managed. It is believed that the heavy pumping from deep wells causes the doward movement of the contaminated, shallow groundwaters and introduces them into the deep aquifers. In this study, we introduces a shallow capture well system, which could effectively prevent the shallow groundwaters of poor water duality from moving into the deep aquifers by pumping of deep production wells. Even though additional costs are required to apply this system, we believe that this method could be appropriate for the deep wells that are important for the public health.

  • PDF

포항지역 지열수의 수리지구화학적 특성

  • 고동찬;염병우;하규철;송윤호
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.453-454
    • /
    • 2004
  • Hydrogeochemical and isotopic characteristics were investigated for groundwater of Tertiary basin in southeastern part of Korea where deep drilling is in progress for geothermal investigation. According to geology, aquifer was distinguished as alluvial, tertiary sedimentary bedrock (bedrock groundwater), and fractured volcanic rock (deep groundwater). Groundwater of each aquifer is distinctively separated in Eh-pH conditions and concentrations of Cl, F, B and HCO$_3$. Deep groundwater has very low level 3H and 14C whereas alluvial groundwater has those of recent precipitation level. However one of deep groundwater show mixed characteristics in terms of hydrochemistry which indicates effect of pumping. Deep groundwater have temperature of 38 to 43$^{\circ}C$ whereas bedrock and alluvial groundwater have temperature less than 2$0^{\circ}C$. Fractured basement rock aquifer has different hydrogeologicalsetting from bedrock and alluvial aquifer considering hydrogeochemical and isotopic characteristics, and temperature.

  • PDF

Assessment of Effects of Groundwater Pumping from Deep Aquifer on Streamflow Depletion (죽산천 주변 암반층 지하수 양수로 인한 하천수 감소 영향 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il Moon;Cha, Joon Ho
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.769-779
    • /
    • 2015
  • The streamflow depletion due to groundwater pumping from deep aquifer near the Juksan stream has been simulated, in this study, by using the surface water and groundwater integrated model, SWAT-ODFLOW in order to analyze the relationship between the stream depletion and hydraulic properties of aquifer and streambed, and to spatially assess the streamflow depletion. The simulated results showed that the streamflow depletion rate divided by the pumping rate for each well location ranges from 10% to 90% with reflecting the various well-stream distance, transmissivity, storativity, and streambed hydraulic conductance. In particular, the streamflow depletion exceeds about 50% of pumping rate for conditions with transmissivity higher than $10m^2/day$ or storage coefficient lower than 0.1. The simulated results in the form of spatial maps indicated that the spatially averaged percent depletion of streamflow is about 53.6% for five years of pumping which is lower than that for shallow aquifer pumping by 12.9%. From the spatially distributed stream depletion, it was found that higher and more rapid stream depletion to pumping occurs near middle-downstream reach.

A Study on Hydraulic Characteristics of Permeable Rock Fractures in Deep Rock Aquifer Using Geothermal Gradient and Pumping Test Data (지온경사와 양수시험 자료를 활용한 심부 암반대수층 투수성 암반균열의 수리특성 연구)

  • Hangbok Lee;Cholwoo Lee;Eui-Seob Park
    • Tunnel and Underground Space
    • /
    • v.34 no.4
    • /
    • pp.312-329
    • /
    • 2024
  • In various underground research projects such as energy storage and development and radioactive waste disposal targeting deep underground, the characteristics of permeable rock fractures that serve as major pathway of groundwater flow in deep rock aquifer are considered as an important evaluation factor in the design, construction, and operation of research facilities. In Korea, there is little research and database on the location and hydraulic characteristics of permeable rock fractures and the pattern of groundwater flow patterns that may occur between fractures in deep rock boreholes. In this paper, the hydraulic characteristics of permeable rock fractures in deep rock aquifer were evaluated through the analysis of geothermal gradient and pumping test data. First, the deep geothermal distribution was identified through temperature logging, and the geothermal gradient was obtained through linear regression analysis using temperature data by depth. In addition, the hydraulic characteristics of the fractured rock were analyzed using outflow temperature obtained from pumping tests. Ultimately, the potential location and hydraulic characteristics of permeable rock fractures, as well as groundwater flow within the boreholes, were evaluated by integrating and analyzing the geophysical logging and hydraulic testing data. The process and results of the evaluation of deep permeable rock fractures proposed in this study are expected to serve as foundational data for the successful implementation of underground research projects targeting deep rock aquifers.

Evaluation of Stream Depletion from Groundwater Pumping in Deep Aquifer Using An Analytical Model (해석적 모형을 이용한 심부대수층 지하수 양수로 인한 하천수 감소량 분석)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.769-777
    • /
    • 2016
  • The objective of this study was to evaluate the stream depletion from groundwater pumping in deep aquifer using the Ward and Lough's analytical solution (2011) which considers a two-layer leaky aquifer system. The calculated results for each pumping from the 110 wells beside streams showed a wide range of non-dimensional stream depletion, that is the streamflow depletion rate divided by the groundwater pumping rate, from lower than 0.1 to more than 0.9 on average for 5 years depending on the specific properties of well location. From the comparison with Hunt's solution (1999) of a single layer aquifer, the Ward and Lough's solution showed about 50% lower than the Hunt's solution due to the difference of hydraulic properties between the first and second layers as well as the lagged effect of vertical leakance. It was also found that the groundwater pumping has a minor effect on the stream depletion if the stream depletion factor (SDF) of the 1st layer is higher than about 1,000 or the SDF of the 2nd layer is higher than about 100, or the vertical leakance is smaller than $10^{-5}s^{-1}$. Furthermore, in the present study, the variations of the stream depletion were assessed according to the magnitude of unmeasured hydraulic properties such as transmissivity and storage coefficient of the 1st layer, vertical hydraulic conductivity of the 2nd layer, the streambed hydraulic conductance.

Research for a cases of overseas constructions and domestic tentative execution about high vacuum dewatering and consolidation/dehydration by Super Well point method (슈퍼웰포인트공법에 의한 고진공배수 압밀탈수에 대한 시공사례)

  • Shin, Chang-Beom;Kim, Dae-Hwal;Takahashi, Shigeyoshi;Lee, Kwang-Yeol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.581-590
    • /
    • 2008
  • A SWP method is a revolutionary dewatering method. The conventional dewatering method, deep-well method, had ever occurred a civil appeal caused by the well depletion in compliance with the reduction of the groundwater level over a wider area considerably by the deep-well pumping from homogeneous sand-layer ground for a dry-work, while pump groung excavation working in Sendai city, Japan 10 years ago. it'd developed with the problematic proposal to find the new method which can lower the groundwater level only within the sheet pile without any reduction of groundwater outside of the sheet pile and until currently steady improvement came. It's been confirmed with plenty of executional results that there was almost no decreasing of water-level from surroundings, over so many construction-sites including vertical shafts which completely does not enter into non-water permeable layer and pumping ground etc. The SWP method in this time has been introducing initially and carried into a the execution tentatively at a construction-site and made a various result get through the execution.

  • PDF

Evaluation of Hydrogeochemistry of Geothermal Water at Heunghae, Pohang Using Pumping Test Results (양수시험에 의한 포항 흥해지역 심부지열수의 수리지화학적 규명)

  • Cho Byong-Wook;Yun Uk;Song Yoon-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.3
    • /
    • pp.20-30
    • /
    • 2006
  • Hydrogeochemistry of deep geothermal water (temperature: $42.2-47.9^{\circ}C$) at Heunghae, Pohang was evaluated using core logging, temperature and electrical conductivity (EC) logging before and after pumping tests, chemical analysis of geothermal water with depth, and observation of water quality variations during pumping tests. The geology of the area is composed of highly fractured marine sedimentary rocks. The hydrogeochemistry of geothermal water varies with drilling depth, distance from the coast, and pumping duration. According to the temperature and EC variations during 4 times of pumping tests, main aquifer of the area is considered as the fractured zones (540 to 900 m) developed in rhyolitic rocks. The high content of Na and $HCO_3$ in geothermal water can be explained by the inflow of deep groundwater from inland regulated by dissolution of silicates and carbonates. High TDS, Na and Cl concentrations indicate that the geothermal water was also strongly affected by seawater. The molar ratios of Na:Cl ($0.88{\sim}2.14$) and Br:Cl ($21.0{\sim}24.9{\times}10^{-4}$) deviate from those of seawater (0.84 and $34.7{\times}10^{-4}$, respectively), suggesting that water-rock interaction also plays an important role in the formation of water quality.

Deep Hydrochemical Investigations Using a Borehole Drilled in Granite in Wonju, South Korea

  • Kim, Eungyeong;Cho, Su Bin;Kihm, You Hong;Hyun, Sung Pil
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.4
    • /
    • pp.517-532
    • /
    • 2021
  • Safe geological disposal of spent nuclear fuel (SNF) requires knowledge of the deep hydrochemical characteristics of the repository site. Here, we conducted a set of deep hydrochemical investigations using a 750-m borehole drilled in a model granite system in Wonju, South Korea. A closed investigation system consisting of a double-packer, Waterra pump, flow cell, and water-quality measurement unit was used for in situ water quality measurements and subsequent groundwater sampling. We managed the drilling water labeled with a fluorescein dye using a recycling system that reuses the water discharged from the borehole. We selected the test depths based on the dye concentrations, outflow water quality parameters, borehole logging, and visual inspection of the rock cores. The groundwater pumped up to the surface flowed into the flow cell, where the in situ water quality parameters were measured, and it was then collected for further laboratory measurements. Atmospheric contact was minimized during the entire process. Before hydrochemical measurements and sample collection, pumping was performed to purge the remnant drilling water. This study on a model borehole can serve as a reference for the future development of deep hydrochemical investigation procedures and techniques for siting processes of SNF repositories.

Improving Groundwater Recovery by Hydrofracturing (인공수압파쇄기법에 의한 지하수 양수량 증대)

  • 한정상;안종성;윤윤영;김형수;백건하
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.23-33
    • /
    • 2002
  • There are two case history. One is the case of 3 wells-group well system-drilled and artificially hydrofractured for dewatering to help to excavate and treat deep building foundation. The recoveries of groundwater of 3 wells are increased 29%, 42% and 110% respectively through hydrofracturing. Simultaneous pumping test reveals that 3 wells are geohydrologically interconnected considering lowered specific capacity comprising influence of additional drawdown effect by other 2 wells compared to single well test. Response time effect during single well test shows that dorminant lineaments are more expandable to other geological structures. The other one is the case of 28% increasing of groundwater productivity for domestic use by hydrofracturing.