• Title/Summary/Keyword: Deep Drilling

Search Result 137, Processing Time 0.027 seconds

Characterization of a groundwater system by subsurface hydrogeological investigation data (지하공동굴착 시 수리지질조사 자료를 이용한 저장공동 심도의 지하수체계 특성 연구)

  • 조성일;김천수;김경수;송무영;전한석
    • The Journal of Engineering Geology
    • /
    • v.14 no.1
    • /
    • pp.93-104
    • /
    • 2004
  • This paper intended to assess the hydro-structure characteristics of volcanic rocks based on the hydrogeological data obtained from the underground storage cavern during construction. The variation of groundwater levels was periodically measured from the 28 surface monitoring holes(NX size) and the hydraulic pressures and injection rates were daily monitored from the water curtain holes(95 horizontal holes and 63 vertical holes). The hydraulic interference tests were performed in whole water curtain holes. The distribution patterns of hydraulic pressure are closely related to the dip angles of fracture intersected to the water curtain holes. Three domains can be grouped by the distribution of hydraulic pressures in the horizontal water curtain holes. The initial hydraulic pressures measured immediately after drilling of water crutain holes are high in ascending order of the cavern C-2, C-1, and C-3. The priliminary hydrochemical data also indicate that the portions of the deep groundwater composition is relatively great in the cavern C-3 area. Some of the horizontal water curtain holes in the cavern C-3 show a steady higher groundwater pressure with the composition of shallow groundwater indicating the outer boundary as constant hydraulic boundary. The water curtain holes in the cavern C-2 is characterized as low initial hydraulic pressure and less injection rates, suggesting poor hydraulic connectivity to a shallow groundwater system. The results of the study can help to understand a hydraulic compartment concept in a fracture hydro-geology and be utilized during the surface investigation for a groundwater system.

A Review of In-Situ Characterization and Quality Control of EDZ During Construction of Final Disposal Facility for Spent Nuclear Fuel (사용후핵연료 최종처분장 건설과정에서의 굴착손상영역(EDZ)의 현장평가 방법 및 시공품질관리 체계에 관한 사례검토)

  • Kim, Hyung-Mok;Nam, Myung Jin;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.32 no.2
    • /
    • pp.107-119
    • /
    • 2022
  • Excavation-Disturbed Zone (EDZ) is an important design factor in constructing final disposal facilities for spent nuclear fuel, since EDZ affects mechanical stability including a spacing between disposal holes, and the hydraulic properties within EDZ plays a significant role in estimating in-flow rate of groundwater as well as a subsequent corrosion rate of a canister. Thus, it is highly required to characterize in-situ EDZ with precision and control the EDZ occurrence while excavating disposal facilities and constructing relevant underground research facilities. In this report, we not only reviewed EDZ-related researches carried out in the ONKALO facility of Finland but also examined appropriate methods for field inspection and quality control of EDZ occurrence. From the review, GPR can be the most efficient method for in-situ characterization of EDZ since it does not demand drilling a borehole that may disturb a surrounding environment of caverns. And the EDZ occurrence was dominant at a cavern floor and it ranged from 0 to 70 cm. These can provide useful information in developing necessary EDZ-related regulations for domestic disposal facilities.

Growth and Grain Yield under Different Direct Seeding Cultures in Rice (벼 직파재배 유형에 따른 생육 및 수량)

  • Choi, Weon-Young;Kim, Sang-Su;Sin, Hyun-Tak;Cho, Soo-Yeon;Choi, Sun-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.1
    • /
    • pp.14-21
    • /
    • 1997
  • This experiment was conducted to identify the growth and yield differences in rice cultural types: Broadcasting on flooded paddy surface(BF), drilling on flooded paddy surface(DF), puddled-soil drill seeding(PD), drill seeding on dried paddy flat(DD), and machine transplanting of lO-day old seedling(MT) at National Honam Agricultural Experiment Station in 1995. Among the cultural types of direct seeding, the number of seedling stand showed high in order of DD>BF>DF>PD. Tillering at early growth stage was faster in MT and effective tiller showed higher in MT than in direct seeding. Growth duration from seeding to heading was longer in direct seeding than in MT for 2-13 days of Dongjinbyeo and 10-18 days of Nonganbyeo. Root distribution ratio at the surface soil revealed high in order of BF>DF>PD>DD and MT. Culm wall thickness of 4th internode was thicker in machine transplanting of 10-day old seedling than in direct seeding, and the depth of buried culm showed deep by turns of MT> DD>PD>DF and BF. The height of center gravity and moment related to lodging revealed higher in direct seeding than machine transplanting that resulted high lodging index by turns of BF>DF>DD> PD among the direct seeding cultural type. Lodging was occured seriously in the order of BF>DF>PD>DD =MT in Dongjinbyeo but wasn't significantly different in Nonganbyeo among the cultural type. The yield components and grain yield showed varietal differences but was not significantly different between in MT and in direct seeding, and among cultural types of direct seeding.

  • PDF

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Evaluation of Hydrogeologic Seal Capacity of Mudstone in the Yeongil Group, Pohang Basin, Korea: Focusing on Mercury Intrusion Capillary Pressure Analysis (포항분지 영일층군 이암층의 수리지질학적 차폐능 평가: 수은 모세관 압입 시험의 결과 분석을 중심으로)

  • Kim, Seon-Ok;Wang, Sookyun;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • Geological CO2 sequestration is a global warming response technology to limit atmospheric emissions by injecting CO2 captured on a large scale into deep geological formations. The presented results concern mineralogical and hydrogeological investigations (FE-SEM, XRD, XRF, and MICP) of mudstone samples from drilling cores of the Pohang basin, which is the research area for the first demonstration-scale CO2 storage project in Korea. They aim to identify the mineral properties of the mudstone constituting the caprock and to quantitatively evaluate the hydrogeologic sealing capacity that directly affects the stability and reliability of geological CO2 storage. Mineralogical analysis showed that the mudstone samples are mainly composed of quartz, K-feldspar, plagioclase and a small amount of pyrite, calcite, clay minerals, etc. Mercury intrusion capillary pressure analysis also showed that the samples generally had uniform particle configurations and pore distribution and there was no distinct correlation between the estimated porosity and air permeability. The allowable CO2 column heights based on the estimated pore-entry pressures and breakthrough pressures were found to be significantly higher than the thickness of the targeting CO2 injection layer. These results showed that the mudstone layers in the Yeongil group, Pohang basin, Korea have sufficient sealing capacity to suppress the leakage of CO2 injected during the demonstration-scale CO2 storage project. It should be noticed, however, that the applicability of results and analyses in this study is limited by the lack of available samples. For rigorous assessment of the sealing efficiency for geological CO2 storage operations, significant efforts on collection and multi-aspect evaluation for core samples over entire caprock formations should be accompanied.

Characteristics of the Land and River Aggregates Distribution in Goyang City, Korea (경기도 고양지역 육상 및 하천골재의 부존 특성)

  • Lee, Hoil;Byun, Uk Hwan;Ko, Kyoungtae;Youm, Seung-Jun;Ji, Sangwoo;Jo, Hwanju;Shin, Seungwon;Lee, Jin-Young
    • Economic and Environmental Geology
    • /
    • v.54 no.5
    • /
    • pp.535-547
    • /
    • 2021
  • Aggregate is an essential construction material, and the demand is increasing every year. Aggregate has different properties in each region, and it is difficult to supply it over long distances due to its quantity and weight. For the stabilization of aggregate supply and demand, regional aggregate resource surveys have been conducted since 1993 in Korea. In this study, an aggregate resource survey was conducted in Goyang City to understand the characteristics of aggregate distribution as part of the annual regional aggregate resource survey in 2020. Goyang City has a high mountainous area to the east, and the southwestern part shows a topography where a wide flatland develops. It has 18 small streams originated from the eastern mountainuos area and 1 large stream Han River. The drilling data shows that thickness of the Quaternary deposits tend to deepen toward the south. The aggregate reserves are relatively abundant, the depth of the aggregates are relatively deep. Changes in the depth of the Quaternary deposits and the amount of aggregate in Goyang are seems to be closely related to the activities of the Han River rather than the sedimentation characteristics from the upstream to the downstream of the small streams. This characteristics show a similar tendency to the distribution of aggregates in adjacent regions to the west coast in Korea. Therefore, the regions that close to west coast have a high probability of aggregate reserves around relatively large-scale streams flowing into the west coast.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF