• Title/Summary/Keyword: Dedicated Channel

Search Result 100, Processing Time 0.022 seconds

Study on an Electrode Attachment Method Suitable for Underwater Electromyography Measurements

  • Han, Seul-ki;Park, Jung-seo;Nam, Taek-gil
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.95-98
    • /
    • 2015
  • PURPOSE: This study was conducted to devise a method of preventing water infiltration into the surface electrodes during EMG measurements underwater and on the ground and to check the reliability of Electromyography (EMG) measurements when underwater. METHODS: Six healthy adults were selected as subjects in this study. The measurements in this study were conducted in pool dedicated to underwater exercise and physical therapy room in the hospital building. An MP150 (Biopac Systems, US, 2010) and a BioNomadix 2-channel wireless EMG transmitter (Biopac Systems, US, 2012) was used to examine the muscle activity of rectus femoris, biceps femoris, tibialis anterior, gastrocnemius of dominant side. The subjects repeated circulation tasks on the ground for more than 10 min for enough surface electrode attachment movement. After a 15-min break, subjects performed the circulation task underwater(water depth 1.1m, water temperature $33.5^{\circ}C$, air temperature $27^{\circ}C$), as on the ground, for more than 10 min, and the MVIC of each muscle was measured again. SPSS v20.0 was used for all statistical computations. RESULTS: The maximum voluntary isometric contraction (MVIC) values between the underwater and on the ground measurements showed no significant differences in all four muscles and showed a high intraclass correlation coefficient (ICC) of >0.80. CONCLUSION: We determined that EMG measurements obtained underwater could be used with high reliability, comparable to ground measurements.

Performance Analysis of a Novel Distributed C-ARQ Scheme for IEEE 802.11 Wireless Networks

  • Wang, Fan;Li, Suoping;Dou, Zufang;Hai, Shexiang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.7
    • /
    • pp.3447-3469
    • /
    • 2019
  • It is well-known that the cooperative communication and error control technology can improve the network performance, but most existing cooperative MAC protocols have not focused on how to cope with the contention process caused by cooperation and how to reduce the bad influence of channel packet error rate on the system performance. Inspired by this, this paper first modifies and improves the basic rules of the IEEE 802.11 Medium Access Control (MAC) protocol to optimize the contention among the multi-relay in a cooperative ARQ scheme. Secondly, a hybrid ARQ protocol with soft combining is adopted to make full use of the effective information in the error data packet and hence improve the ability of the receiver to decode the data packet correctly. The closed expressions of network performance including throughput and average packet transmission delay in a saturated network are then analyzed and derived by establishing a dedicated two-dimensional Markov model and solving its steady-state distribution. Finally, the performance evaluation and superiority of the proposed protocol are validated in different representative study cases through MATLAB simulations.

Approach to diagnosing multiple abnormal events with single-event training data

  • Ji Hyeon Shin;Seung Gyu Cho;Seo Ryong Koo;Seung Jun Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.558-567
    • /
    • 2024
  • Diagnostic support systems are being researched to assist operators in identifying and responding to abnormal events in a nuclear power plant. Most studies to date have considered single abnormal events only, for which it is relatively straightforward to obtain data to train the deep learning model of the diagnostic support system. However, cases in which multiple abnormal events occur must also be considered, for which obtaining training data becomes difficult due to the large number of combinations of possible abnormal events. This study proposes an approach to maintain diagnostic performance for multiple abnormal events by training a deep learning model with data on single abnormal events only. The proposed approach is applied to an existing algorithm that can perform feature selection and multi-label classification. We choose an extremely randomized trees classifier to select dedicated monitoring parameters for target abnormal events. In diagnosing each event occurrence independently, two-channel convolutional neural networks are employed as sub-models. The algorithm was tested in a case study with various scenarios, including single and multiple abnormal events. Results demonstrated that the proposed approach maintained diagnostic performance for 15 single abnormal events and significantly improved performance for 105 multiple abnormal events compared to the base model.

Development of a Real-time OS Based Control System for Laparoscopic Surgery Robot (복강경 수술로봇을 위한 실시간 운영체제 기반 제어 시스템의 개발)

  • Song, Seung-Joon;Park, Jun-Woo;Shin, Jung-Wook;Kim, Yun-Ho;Lee, Duk-Hee;Jo, Yung-Ho;Choi, Jae-Seoon;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.32-39
    • /
    • 2008
  • This paper reports on a realtime OS based master-slave configuration robot control system for laparoscopic surgery robot which enables telesurgery and overcomes shortcomings with conventional laparoscopic surgery. Surgery robot system requires control system that can process large volume information such as medical image data and video signal from endoscope in real-time manner, as well as precisely control the robot with high reliability. To meet the complex requirements, the use of high-level real-time OS (Operating System) in surgery robot controller is a must, which is as common as in many of modem robot controllers that adopt real-time OS as a base system software on which specific functional modules are implemened for more reliable and stable system. The control system consists of joint controllers, host controllers, and user interface units. The robot features a compact slave robot with 5 DOF (Degree-Of-Freedom) expanding the workspace of each tool and increasing the number of tools operating simultaneously. Each master, slave and Gill (Graphical User Interface) host runs a dedicated RTOS (Real-time OS), RTLinux-Pro (FSMLabs Inc., U.S.A.) on which functional modules such as motion control, communication, video signal integration and etc, are implemented, and all the hosts are in a gigabit Ethernet network for inter-host communication. Each master and slave controller set has a dedicated CAN (Controller Area Network) channel for control and monitoring signal communication with the joint controllers. Total 4 pairs of the master/slave manipulators as current are controlled by one host controller. The system showed satisfactory performance in both position control precision and master-slave motion synchronization in both bench test and animal experiment, and is now under further development for better safety and control fidelity for clinically applicable prototype.

Feasibility of On-chip Detection of Endotoxin by LAL Test

  • Lee, Eun-Kyu;Suh, Chang-Woo;Hwang, Sang-Youn;Park, Hyo-Jin;Seong, Gi-Hoon;Ahn, Yoo-Min;Kim, Yang-Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2004
  • The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (lab-on-a-chip) prototype, 62mm (L) ${\times}$ 18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2mm (W) ${\times}$ 44.3mm (L) ${\times}$ 100 $\mu\textrm{m}$ (D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip thickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 to ca. 4.4 ${\mu}$L. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.

An Efficient Mobile Multicast Mechanism based on Media Independent Handover (MIH 기반의 효율적인 모바일 멀티캐스트 핸드오버 기법)

  • Kim, Won-Tae;Kang, Eun-Hyun;Park, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.6
    • /
    • pp.37-47
    • /
    • 2009
  • In this paper fast mobile multicast handover mechanism based on IEEE 802.21 MIH (Media Independent Handover) is proposed. We solve long multicast handover delay time caused by L3 movement detection mechanism of the existing mobile multicast methods. The proposed architecture adopts multicast manager concept to MIH framework in order to efficiently perform mobile multicast handover, and adds the new MIH messages dedicated for mobile multicast. Since multicast channel zapping operations of mobile users effectively make a mobile terminal handover, the architecture should consider the situations. Multicast network selection algorithm is designed by means of terminal speed and fair selection algorithm named AHP/GRA. Finally the performance of the proposed architecture against the legacy mobile multicast mechanisms is evaluated in terms of signaling cost and multicast handover delay time.

A 12b 100 MS/s Three-Step Hybrid Pipeline ADC Based on Time-Interleaved SAR ADCs

  • Park, Jun-Sang;An, Tai-Ji;Cho, Suk-Hee;Kim, Yong-Min;Ahn, Gil-Cho;Roh, Ji-Hyun;Lee, Mun-Kyo;Nah, Sun-Phil;Lee, Seung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.189-197
    • /
    • 2014
  • This work proposes a 12b 100 MS/s $0.11{\mu}m$ CMOS three-step hybrid pipeline ADC for high-speed communication and mobile display systems requiring high resolution, low power, and small size. The first stage based on time-interleaved dual-channel SAR ADCs properly handles the Nyquist-rate input without a dedicated SHA. An input sampling clock for each SAR ADC is synchronized to a reference clock to minimize a sampling-time mismatch between the channels. Only one residue amplifier is employed and shared in the proposed ADC for the first-stage SAR ADCs as well as the MDAC of back-end pipeline stages. The shared amplifier, in particular, reduces performance degradation caused by offset and gain mismatches between two channels of the SAR ADCs. Two separate reference voltages relieve a reference disturbance due to the different operating frequencies of the front-end SAR ADCs and the back-end pipeline stages. The prototype ADC in a $0.11{\mu}m$ CMOS shows the measured DNL and INL within 0.38 LSB and 1.21 LSB, respectively. The ADC occupies an active die area of $1.34mm^2$ and consumes 25.3 mW with a maximum SNDR and SFDR of 60.2 dB and 69.5 dB, respectively, at 1.1 V and 100 MS/s.

A study on the Medicines Effected on the Liver in the 'Bowel-Viscus Classification' of An Introduction to Medical Science ($\ll$의학입문(醫學入門).장부조분(臟腑條分)$\gg$간장(肝臟)에 작용하는 약물(藥物)에 관한 연구(硏究))

  • Keum, Kyung-Soo;Lim, Yang-Sun
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.11 no.1
    • /
    • pp.26-47
    • /
    • 2005
  • In this dissertation, I will focus on the channel entry, the effect, and the treatment throughout books of oriental medicine from ancient to modern in order to classify the medicines of the liver as main or supplementary organ. The results are as follows: 1. The kinds of the medicines of working of the liver(本臟) were 29, which were Amydae carapax(鱉甲), Chrysanthemi Flos(菊花), Cassiae Torae Semen(草決明), Plantaginis Semen(車前子), Scirpi Seu Sparganii(三稜), Ulmi Pasta Semen(蕪荑), Cinnamomi Cortex(肉桂), Fraxini Cortex(秦皮), Chaenomelis Fructus(木果), Corii Asini Colla(阿膠), Chuanxiong Rhizoma(川芎), Adenophorae Radix(沙蔘), Coicis Semen(薏苡仁), Acanthopanacis Cortex(五加皮), Zizyphi Spinosae Semen(酸棗仁), Picrorrhizae Rhizoma(胡黃連), Gentianae Radix(草龍膽), Citri Reticulatae Virdie Pericarpium(靑皮), Paeoniae Alba Radix(白芍藥), Paeoniae Rubra Radix(赤芍藥), Bupleuri Radix(柴胡), Peucedani Radix(前胡), Naturalis Indigo(靑黛), Citrus unshiu(橘葉), Rhinocerotis Cornu(犀角), Aucklandiae Radix(木香), Polygonati Odorati Rhizoma, Farfarae Flos(款冬花), Evodiae Fructus(吳茱萸), Citri Reticulatae Pericarpium(陳皮) . 2. The kinds of the medicines of working of other viscera(他臟) were 7, which were Astragaliadix(黃耆), Ginseng Radix(人蔘), pinelliae Rhizoma(半夏), Myristicae Semen, Euryales Semen, Arecae Semen, Piperis Longi Fructus. 3. Medicines, effected on the heart functioned through any other viscera are as follows: Arecae Semen works to treat Spleen Gi Entering the Liver(脾氣入肝), Piperis Longi Fructus, pinelliae Rhizoma(半夏), Euryales Semen and Myristicae Semen operate to treat Spleen Cold Entering the Liver(脾冷入肝), Astragali Radix(黃耆) and Ginseng Radix(人蔘) work to treat Spleen Vacuity Entering the Liver(脾虛入肝). In the study of concerning the medicines effected on the liver, It is considered that it dedicated to development of the medicines related to the disease of the liver and making efficient use of the medicines.

  • PDF

Spectrum Reuse Schemes with Power Control for Device-to-Device Communication in LTE-Advanced Cellular Network

  • Chhorn, Sok;Yoon, Seok-Ho;Seo, Si-O;Kim, Seung-Yeon;Cho, Choong-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.12
    • /
    • pp.4819-4834
    • /
    • 2015
  • The spectral efficiency of cellular networks can be improved when proximate users engage in device-to-device (D2D) communications to communicate directly without going through a base station. However, D2D communications that are not properly designed may generate interference with existing cellular networks. In this paper, we study resource allocation and power control to minimize the probability of an outage and maximize the overall network throughput. We investigate three power control-based schemes: the Partial Co-channel based Overlap Resource Power Control (PC.OVER), Fractional Frequency Reuse based Overlap Resource Power Control (FFR.OVER) and Fractional Frequency Reuse based Adaptive Power Control (FFR.APC) and also compare their performance. In PC.OVER, a certain portion of the total bandwidth is dedicated to the D2D. The FFR.OVER and FFR.APC schemes combine the FFR techniques and the power control mechanism. In FFR, the entire frequency band is partitioned into two parts, including a central and edge sub-bands. Macrocell users (mUEs) transmit using uniform power in the inner and outer regions of the cell, and in all three schemes, the D2D receivers (D2DRs) transmit with low power when more than one D2DRs share a resource block (RB) with the macrocells. For PC.OVER and FFR.OVER, the power of the D2DRs is reduced to its minimum, and for the FFR.APC scheme, the transmission power of the D2DRs is iteratively adjusted to satisfy the signal to interference ratio (SIR) threshold. The three schemes exhibit a significant improvement in the overall system capacity as well as in the probability of a user outage when compared to a conventional scheme.

Multibeam-based Subspace Approach for Code Acquisition in Antenna Array DS-CDMA Systems (안테나 어레이 DS-CDMA 통신 시스템에서 코드 동기 획득을 위한 다중 빔 기반의 부분공간 접근 방법)

  • Kim, Sang-Choon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.6
    • /
    • pp.1167-1173
    • /
    • 2005
  • In this paper, the use of an antenna array is considered for code timing acquisition of DS-CDMA signals. The probabilities of acquisition are evaluated by applying multiple narrow fixed-beams to the conventional MUSIC acquisition approach in the multiuser environment on the time-varying Rayleigh fading channel. Each fixed-beam for spatial filtering is dedicated to an individual angular sector that is formed by dividing the entire angular domain by the number of antenna elements. The fixed-beams with a capability of interference suppression provide the additional degrees of freedom,. Hence, the multibeam-based MUSIC estimator can be used to synchronize to more users than the conventional MUSIC algorithm for one antenna. The multibeam-based subspace method is evaluated to significantly improve the performance of a single antenna based MUSIC technique in multiuser scenarios.